1 Dec 2013
Barnes L Parks C Bushmiaer M
Full Access

PURPOSE:

Wright Medical has a long history of modular neck hip implants but had fracture issues with the original titanium necks. They subsequently changed to chrome cobalt modular necks. Direct contact between these dissimilar metal parts in the modular femoral component brings into consideration the possibility of similar adverse reactions of metal-on-metal articulations that have been previously described in other designs.

METHODS:

A retrospective review of 10 patients with Wright Medical chrome cobalt modular necks who were evaluated with chromium and cobalt metal ion levels as well as Metal Artifact Reduction Sequence (MARS) MRI's was performed. Pseudotumors were classified by MRI based on wall thickness, T1/T2 signal, shape, and location and given a corresponding type of I, II, or III. For each patient, symptoms or lack thereof were recorded, and time since surgery noted.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 300 - 300
1 Dec 2013
Greber E Barnes CL Bushmiaer M Wilson R Edwards P Petrus C
Full Access

Periprosthetic joint infections (PJI) continue to be a diagnostic challenge for orthopedic surgeons. Chronic PJI are sometimes difficult to diagnose and occasionally present in a subclinical fashion with normal CRP/ESR and/or normal joint aspiration. Some institutions advocate for routine use of intraoperative culture swabs at the time of all revision surgeries to definitively rule out infection. The purpose of this study is to determine whether routine intraoperative cultures is an appropriate and cost effective method of diagnosing subclinical chronic PJI in revision joint replacement patients with a low clinical suspicion for infection.

We performed a retrospective chart review and identified 33 patients that underwent revision hip or knee replacement from a single surgeon over a five-month period. The AAOS guidelines for preoperative PJI workup were followed. 13 patients were diagnosed preoperatively with infection and excluded from the study. 20 patients underwent revision joint replacement and three separate cultures swabs were taken for each patient to help in determining true-positive cultures. Infectious Disease was consulted for all patients with any positive culture. Culture results were reviewed. At our hospital, the cost billed to insurance for a single culture is $1,458.58. We did not calculate the cost of the consultant fee.

Three (15%) of the 20 revision arthroplasty patients had a single positive culture. Infectious Disease consultants diagnosed all three of these positive cultures as contaminants. None of the patients had a true-positive intraoperative culture. The total cost billed by the hospital to obtain these cultures in all 20 patients was $87,514.80

In our study, obtaining a set of three intraoperative cultures for those patients with a negative preoperative infection workup was not only cost prohibitive but did not diagnose a single subclinical infection. Studies to find other more reliable, accurate, and cost effective alternatives to diagnose PJI are warranted.

In patients undergoing revision hip or knee arthroplasty with a low preoperative clinical suspicion for infection, it does not seem that routine intraoperative culture swabs are necessary or cost effective method for diagnosing subclinical periprosthetic joint infection.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 327 - 327
1 Dec 2013
Greber E Bushmiaer M Barnes L
Full Access

Background:

Until recently, there has been no consensus of the best approach to dIfferentiating aseptic from septic loosening in joint replacement patients. The recent AAOS Clinical Practice Guideline Summary that was published in 2010, tasks orthopedic surgeons with the strong recommendation of obtaining ESR and CRP for all patients needing hip and knee arthroplasty revision surgery and aspirating the joint based upon these results. The purpose of this study is to determine from our patients whether this guideline has been helpful and cost effective in determining periprosthetic joint infections.

Methods:

We retrospectively reviewed charts of 50 consecutive patients who underwent revision total hip or knee arthroplasty. Each patient received an ESR and CRP level prior to operation and patients with known periprosthetic joint infections were excluded from the study. As guidelines recommend, aspiration with cultures and cell count were obtained on all knees with either elevated ESR or CRP and all hips with both ESR and CRP elevated. We then determined how many patients needing revision arthroplasty of the hip or knee benefited from ESR, CRP, and aspiration by finding subclinical periprosthetic infection and changing the intraoperative treatment. Hospital charge data was used to report cost of this protocol.