Previous research has demonstrated increased early complication rates following total hip arthroplasty (THA) in obese patients, as defined by body mass index (BMI). Subcutaneous fat depth (FD) has been shown to be an independent risk factor for wound infection in cervical and lumbar spine surgery, as well as after abdominal laparotomy. The aim of this study was to investigate whether increased peritrochanteric FD was associated with an increased risk of complications in the first year following THA. We analyzed prospectively collected data on a consecutive series of 1,220 primary THAs from June 2013 until May 2018. The vertical soft tissue depth from the most prominent part of the greater trochanter to the skin was measured intraoperatively using a sterile ruler and recorded to the nearest millimetre. BMI was calculated at the patient’s preoperative assessment. All surgical complications occuring within the initial 12 months of follow-up were identified.Aims
Methods
The aim of this retrospective audit was to determine the route of referral or presentation of patients requiring revision following primary total hip arthroplasty (THA). A total of 4802 patients were implanted with an Orthopaedic Data Evaluation Panel (ODEP) 10A* cementless implant (Corail/Pinnacle) between 2005 and 2015; 80 patients with a mean age of 67.8 years (Aims
Patients and Methods
Our aim was to report survivorship data and lessons learned with
the Corail/Pinnacle cementless total hip arthroplasty (THA) system. Between August 2005 and March 2015, a total of 4802 primary cementless
Corail/Pinnacle THAs were performed in 4309 patients. In March 2016,
we reviewed these hips from a prospectively maintained database.Aims
Patients and Methods
Ideal placement of the acetabular component remains
elusive both in terms of defining and achieving a target. Our aim
is to help restore original anatomy by using the transverse acetabular
ligament (TAL) to control the height, depth and version of the component.
In the normal hip the TAL and labrum extend beyond the equator of
the femoral head and therefore, if the definitive acetabular component
is positioned such that it is cradled by and just deep to the plane
of the TAL and labrum and is no more than 4mm larger than the original
femoral head, the centre of the hip should be restored. If the face
of the component is positioned parallel to the TAL and psoas groove
the patient specific version should be restored. We still use the
TAL for controlling version in the dysplastic hip because we believe
that the TAL and labrum compensate for any underlying bony abnormality. The TAL should not be used as an aid to inclination. Worldwide,
>
75% of surgeons operate with the patient in the lateral decubitus
position and we have shown that errors in post-operative radiographic
inclination (RI) of >
50° are generally caused by errors in patient positioning.
Consequently, great care needs to be taken when positioning the
patient. We also recommend 35° of apparent operative inclination
(AOI) during surgery, as opposed to the traditional 45°. Cite this article:
Ceramic-on-metal (CoM) is a relatively new bearing
combination for total hip arthroplasty (THA) with few reported outcomes.
A total of 287 CoM THAs were carried out in 271 patients (mean age
55.6 years (20 to 77), 150 THAs in female patients, 137 in male)
under the care of a single surgeon between October 2007 and October
2009. With the issues surrounding metal-on-metal bearings the decision
was taken to review these patients between March and November 2011,
at a mean follow-up of 34 months (23 to 45) and to record pain,
outcome scores, radiological analysis and blood ion levels. The
mean Oxford Hip Score was 19.2 (12 to 53), 254 patients with 268
hips (95%) had mild/very mild/no pain, the mean angle of inclination
of the acetabular component was 44.8o (28o to
63o), 82 stems (29%) had evidence of radiolucent lines
of >
1 mm in at least one Gruen zone and the median levels of cobalt
and chromium ions in the blood were 0.83 μg/L (0.24 μg/L to 27.56 μg/L)
and 0.78 μg/L (0.21 μg/L to 8.84 μg/L), respectively. The five-year
survival rate is 96.9% (95% confidence interval 94.7% to 99%). Due to the presence of radiolucent lines and the higher than
expected levels of metal ions in the blood, we would not recommend
the use of CoM THA without further long-term follow-up. We plan
to monitor all these patients regularly. Cite this article:
In an initial randomised controlled trial (RCT)
we segregated 180 patients to one of two knee positions following total
knee replacement (TKR): six hours of knee flexion using either a
jig or knee extension. Outcome measures included post-operative
blood loss, fall in haemoglobin, blood transfusion requirements,
knee range of movement, limb swelling and functional scores. A second
RCT consisted of 420 TKR patients randomised to one of three post-operative
knee positions: flexion for three or six hours post-operatively,
or knee extension. Positioning of the knee in flexion for six hours immediately
after surgery significantly reduced blood loss (p = 0.002). There
were no significant differences in post-operative range of movement,
swelling, pain or outcome scores between the various knee positions
in either study. Post-operative knee flexion may offer a simple
and cost-effective way to reduce blood loss and transfusion requirements
following TKR. We also report a cautionary note regarding the potential risks
of prolonged knee flexion for more than six hours observed during
clinical practice in the intervening period between the two trials,
with 14 of 289 patients (4.7%) reporting lower limb sensory neuropathy
at their three-month review. Cite this article:
With greater numbers of younger patients undergoing
total hip replacement (THR), the effect of patient age on the diameter
of the femoral canal may become more relevant. This study aimed
to investigate the relationship between the diameter of the diaphysis
of the femoral canal with increasing age in a large number of patients
who underwent THR. A total of 1685 patients scheduled for THR had
their femoral dimensions recorded from calibrated radiographs. There
were 736 males and 949 females with mean ages of 67.1 years (34
to 92) and 70.2 years (29 to 92), respectively. The mean diameter
of the femoral canal was 13.3 mm (8.0 to 23.0) for males and 12.7
mm (6.0 to 26.0) for females. There was a poor correlation between
age and the diameter of the canal in males (r = 0.071, p = 0.05)
but a stronger correlation in females (r = 0.31, p <
0.001). The diameter of the femoral canal diameter of a female patient
undergoing THR could be predicted to increase by 3.2 mm between
the ages of 40 and 80 years, in contrast a male would be expected
to experience only a 0.6 mm increase during the same period. This
increase in the diameter of the canal with age might affect the
long-term survival of the femoral component in female patients. Cite this article:
The Cementless Oxford Unicompartmental Knee Replacement
(OUKR) was developed to address problems related to cementation,
and has been demonstrated in a randomised study to have similar
clinical outcomes with fewer radiolucencies than observed with the
cemented device. However, before its widespread use it is necessary
to clarify contraindications and assess the complications. This
requires a larger study than any previously published. We present a prospective multicentre series of 1000 cementless
OUKRs in 881 patients at a minimum follow-up of one year. All patients
had radiological assessment aligned to the bone–implant interfaces
and clinical scores. Analysis was performed at a mean of 38.2 months
(19 to 88) following surgery. A total of 17 patients died (comprising
19 knees (1.9%)), none as a result of surgery; there were no tibial
or femoral loosenings. A total of 19 knees (1.9%) had significant
implant-related complications or required revision. Implant survival
at six years was 97.2%, and there was a partial radiolucency at
the bone–implant interface in 72 knees (8.9%), with no complete radiolucencies.
There was no significant increase in complication rate compared
with cemented fixation (p = 0.87), and no specific contraindications
to cementless fixation were identified. Cementless OUKR appears to be safe and reproducible in patients
with end-stage anteromedial osteoarthritis of the knee, with radiological
evidence of improved fixation compared with previous reports using
cemented fixation. Cite this article:
Restoration of leg length and offset is an important
goal in total hip replacement. This paper reports a calliper-based technique
to help achieve these goals by restoring the location of the centre
of the femoral head. This was validated first by using a co-ordinate
measuring machine to see how closely the calliper technique could
record and restore the centre of the femoral head when simulating
hip replacement on Sawbone femur, and secondly by using CT in patients
undergoing hip replacement. Results from the co-ordinate measuring machine showed that the
centre of the femoral head was predicted by the calliper to within
4.3 mm for offset (mean 1.6 (95% confidence interval (CI) 0.4 to
2.8)) and 2.4 mm for vertical height (mean -0.6 (95% CI -1.4 to
0.2)).
The CT scans showed that offset and vertical height were restored
to within 8 mm
(mean -1 (95% CI -2.1 to 0.6)) and -14 mm (mean 4 (95% CI 1.8 to
4.3)), respectively. Accurate assessment and restoration of the centre of the femoral
head is feasible with a calliper. It is quick, inexpensive, simple
to use and can be applied to any design of femoral component.
The angle of inclination of the acetabular component in total hip replacement is a recognised contributing factor in dislocation and early wear. During non-navigated surgery, insertion of the acetabular component has traditionally been performed at an angle of 45° relative to the sagittal plane as judged by the surgeon’s eye, the operative inclination. Typically, the method used to assess inclination is the measurement made on the postoperative anteroposterior radiograph, the radiological inclination. The aim of this study was to measure the intra-operative angle of inclination of the acetabular component on 60 consecutive patients in the lateral decubitus position when using a posterior approach during total hip replacement. This was achieved by taking intra-operative photographs of the acetabular inserter, representing the acetabular axis, and a horizontal reference. The results were compared with the post-operative radiological inclination. The mean post-operative radiological inclination was 13° greater than the photographed operative inclination, which was unexpectedly high. It appears that in the lateral decubitus position with a posterior approach, the uppermost hemipelvis adducts, thus reducing the apparent operative inclination. Surgeons using the posterior approach in lateral decubitus need to aim for a lower operative inclination than when operating with the patient supine in order to achieve an acceptable radiological inclination.
We studied 4253 patients undergoing primary joint replacement between November 2002 and November 2007, of whom 4060 received aspirin only as chemical prophylaxis; 46 were mistakenly given low molecular weight heparin initially, which was stopped and changed to aspirin; 136 received no chemoprophylaxis and 11 patients received warfarin because of a previous history of pulmonary embolism. We identified the rate of clinical thromboembolism before and after discharge, and the mortality from pulmonary embolism at 90 days. The overall death rate was 0.31% (13 of 4253) and the rate of fatal pulmonary embolism was 0.07% (3 of 4253). Our data suggest that fatal pulmonary embolism is not common following elective primary joint replacement, and with modern surgical practice elective hip and knee replacement should no longer be considered high-risk procedures.
We have studied the concept of posterior condylar offset and the importance of its restoration on the maximum range of knee flexion after posterior-cruciate-ligament-retaining total knee replacement (TKR). We measured the difference in the posterior condylar offset before and one year after operation in 69 patients who had undergone a primary cruciate-sacrificing mobile bearing TKR by one surgeon using the same implant and a standardised operating technique. In all the patients true pre- and post-operative lateral radiographs had been taken. The mean pre- and post-operative posterior condylar offset was 25.9 mm (21 to 35) and 26.9 mm (21 to 34), respectively. The mean difference in posterior condylar offset was + 1 mm (−6 to +5). The mean pre-operative knee flexion was 111° (62° to 146°) and at one year postoperatively, it was 107° (51° to 137°). There was no statistical correlation between the change in knee flexion and the difference in the posterior condylar offset after TKR (Pearson correlation coefficient r = −0.06, p = 0.69).
We performed a randomised, controlled trial involving 150 patients with a pre-operative level of haemoglobin of 13.0 g/dl or less, to compare the effect of either topical fibrin spray or intravenous tranexamic acid on blood loss after total knee replacement. A total of 50 patients in the topical fibrin spray group had 10 ml of the reconstituted product applied intra-operatively to the operation site. The 50 patients in the tranexamic acid group received 500 mg of tranexamic acid intravenously five minutes before deflation of the tourniquet and a repeat dose three hours later, and a control group of 50 patients received no pharmacological intervention. There was a significant reduction in the total calculated blood loss for those in the topical fibrin spray group (p = 0.016) and tranexamic acid group (p = 0.041) compared with the control group, with mean losses of 1190 ml (708 to 2067), 1225 ml (580 to 2027), and 1415 ml (801 to 2319), respectively. The reduction in blood loss in the topical fibrin spray group was not significantly different from that achieved in the tranexamic acid group (p = 0.72).
Dislocation after primary total hip arthroplasty is a relatively common complication. The incidence is usually between 1% and 4%, although 0% to 10% has been reported in the literature. The posterior approach is by far the most popular by surgeons, but it reportedly has an increase risk of post-operative dislocation. The posterior approach causes disruption of the posterior capsule and the short external rotators. Studies have shown that repair of the posterior capsule and the short external rotators greatly reduce the dislocation rate.
There are no transfusion guidelines defined for Total knee arthroplasty (TKA), and each orthopaedic unit usually has its own protocol when it comes to transfusion. With the present climate of concern about non-autologous blood transfusions and transmission of infection, orthopaedic units are trying to keep their transfusion rates to a minimum and only transfuse when absolutely necessary.
Of the 150 patients reviewed after the change in transfusion trigger (Hct <
0.25), only 29% were transfused – 35% of females and 18% of males. 50% of patients with a pre-operative Hb of 12 g/dl or less were transfused.
Hb drop = Pre-op Hb – (Day 3 Hb + No. of units of blood received) (We assumed that one unit of blood equates to one gram increase in circulating haemoglobin).
Two hundred and eight consented patients (24.2%) were identified from 860 primary knee arthroplasties carried out over a 33-month period by a single surgeon. An LCS mobile bearing prosthesis was used in all cases. The mean valgus deformity measured 12.1 degrees (range 1–38). Fifty four percent of patients had a deformity of greater than 10 degrees. The patella was not resurfaced in any patient.
Of note 61 (29.3%) patients required a lateral patellar release for patellar maltracking. No patellar complications were noted. Mean patellar tilt was 1.1 degrees (sd=0.6 degrees) and mean patellar congruency 98% (sd=0.7%).
Recent studies, including the Swedish Hip Register, have confirmed that modern cementing techniques are important to achieve long-term implant survival. Their ultimate goal is to obtain an increased strength of cement and its interfaces with bone, thereby maintaining secure fixation and effective load transmission. The objective of this study was to measure the medullary pressures generated during bone cement injection, pressurisation and femoral prosthesis insertion for total hip arthroplasty. The measurements were recorded throughout the length of an in vitro femoral model while implanting a series of prosthetic hip stems using different pressurisation techniques. The prostheses used were the Charnley 40 flanged stem, an Exeter No. 3 stem, and a custom primary femoral component used in Belfast (Johnson &
Johnson, DePuy International Ltd.). The following parameters were derived from the pressure data recorded; peak pressure, decay pressure and duration above 76 kPa, the pressure regarded as the threshold to obtain adequate bone penetration. The range of peak distal stem pressures expected for all stems was 200–500kPa. The custom and Exeter stems generated proximal cement pressures in the range 100–300kPa. These pressures were attained through cement containment by stem design or auxiliary pressurising devices, respectively. It was observed that the Charnley femoral component did not perform as well with regard to proximal pressurisation, irrespective of which pressurisation technique was implemented. The durations of pressure maintenance above 76kPa are also important, 5 seconds being accepted as a minimum for an effective interface. These results reflect the pressure measurements, with adequate durations being maintained by those stems and pressurisers that were characterised by higher peak pressures. It is concluded that stem design and the complementary cement management techniques are essential to realise the pressure/time characteristics that are regarded as necessary to form an optimum bone/cement interface.
Total knee arthroplasty has evolved considerably over the last thirty years. Early implant design achieved the short-term goals of pain relief and mobility, however loosening and polyethylene wear associated with over constraint was problematic. The Low Contact Stress total knee arthroplasty was developed in an attempt to address the problems of loosening and polyethylene wear. The highly congruent interface between the femoral component and the mobile insert minimises stress within the polyethylene and reduces the potential of wear and damage. Furthermore, the mobile bearing phenomenon minimises both torsional and shear stresses at the component bone interface. In our unit the impact of choice is the LCS rotating platform prosthesis, which is inserted with cruciate-sacrifice. We reviewed 219 patients (272 knees) with an average follow-up of 6 years (5–8 years). In almost all cases the components were inserted with cement fixation. The patella was primarily resurfaced in 20 patients (21 knees). All operations were performed or supervised by the senior author. Female to male ratio was 2:1. Average age at surgery was 68 years (40–86) with osteoarthritis being the commonest primary diagnosis (89%). Postoperative range of motion ranges from 30–130° (average 103°). Average Oxford Knee, American Knee Society Score and Patellar Score was 19 (12–53), 160 (42–199) and 25 (4–30) respectively. Six patients (1.7%) required MUA at six weeks. Two patients (0.6%) required secondary patellar resurfacing. Three patients (0.8%) had revision of their components for persistent pain. At operation all components were noted to be well fixed. Spinout of the rotating platform occurred in one patient (0.3%). This was treated by exchange of the insert. In conclusion, our early results of the LCS rotating platform prosthesis are encouraging with no cases of component loosening to date. This supports the continued use of the implant.