Advertisement for orthosearch.org.uk
Results 1 - 17 of 17
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 49 - 49
19 Aug 2024
Beverland D Wong ML Robinson M Cassidy R Lamb J Diamond O
Full Access

A: - determine the incidence of intraoperative periprosthetic femoral fracture (PFF)

B: - determine the incidence of, and the reoperation rate for postoperative PFF

When using either CC or PTS femoral components.

Retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All PFFs were identified using regional radiograph archiving and electronic care systems.

Of the 11,018 THAs 4,952 were CC and 6,066 were PTS. Between groups, age, sex, and BMI did not differ.

A: - 55 (0.5%) had an intraoperative PFF. 44 CC and 11 PTS (p<0.001). 3 patients in each group had a femoral shaft fracture, remaining fractures were either the calcar (20 CC and 2 group) or the greater trochanter (11 CC and 6 PTS).

B: - 91(0.8%) sustained a postoperative PFF. Of those 15 were managed conservatively, 15 were revised and 61 (80.3%) had an ORIF. The CC group had both a lower overall rate of postoperative PFFs (0.7% (36/4,952) vs 0.9% (55/6,066); p = 0.341), and a lower rate of return to theatre (0.4% (22/4,952) vs 0.9% (54/6,066); p = 0.005). 1.3% of male PTS (36/2,674) had a reoperation compared to 0.3% of male CC (7/2,121) (p<0.001).

With regard to stem fracture there were none in the Corail group and 5 in the Exeter group. Of these 2 were sub trunnion and 3 were basal neck.

A: - There were significantly more intraoperative PFFs with CC 44 (0.8%) than PTS 11 (0.2%). However, the majority of fractures were either of the calcar or greater trochanter with no impact on early recovery or one year Oxford scores.

B: - Male PTS were five times more likely to have a reoperation for postoperative PFF. Females had the same incidence of reoperation with either component type.

There were 5 stem fractures in the Exeter group and none in the Corail.

These results represent robust estimates, which are likely to be more accurate than revision only studies typically generated from registry data.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 35 - 35
2 May 2024
Robinson M Wong ML Cassidy R Bryce L Lamb J Diamond O Beverland D
Full Access

The significance of periprosthetic fractures about a total hip arthroplasty (THA) is becoming increasingly important. Recent studies have demonstrated post-operative periprosthetic fracture rates are higher amongst cemented polished taper slip (PTS) stem designs compared to collared cementless (CC) designs.

However, in the National Joint Registry, the rate of intra-operative periprosthetic femoral fractures (IOPFF) with cementless implant systems remains higher (0.87% vs 0.42%. p <0.001) potentially leading to more post-operative complications.

This study identifies the incidence of IOPFF, the fracture subtype and compares functional outcomes and revision rates of CC femoral implants with an IOPFF to CC stems and PTS stems without a fracture.

5376 consecutive CC stem THA, carried out through a posterior approach were reviewed for IOPFF. Each fracture was subdivided into calcar fracture, greater trochanter (GT) fracture or shaft fracture.

1:1:1 matched analysis was carried out to compare Oxford scores at one year. Matching criteria included; sex (exact), age (± 1 year), American Society of Anaesthesiologists (ASA) grade (exact), and date of surgery (± 6 months).

Electronic records were used to review revision rates.

Following review of the CC stems, 44 (0.8%) were identified as having an IOPFF. Of these 30 (0.6%) were calcar fractures, 11 (0.2%) GT fractures and 3 (0.06%) were shaft fractures. There were no shaft penetrations.

Overall, no significant difference in Oxford scores at one year were observed when comparing the CC IOPFF, CC non-IOPFF and PTS groups.

There were no CC stems revised for any reason with either a calcar fracture or trochanteric fracture within the period of 8 years follow-up.

IOPFF do occur more frequently in cementless systems than cemented. The majority are calcar and GT fractures. These fractures, when identified and managed intra-operatively, do not have worse functional outcomes or revision rates compared to matched non-IOPFF cases.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 144 - 150
1 Feb 2024
Lynch Wong M Robinson M Bryce L Cassidy R Lamb JN Diamond O Beverland D

Aims

The aim of this study was to determine both the incidence of, and the reoperation rate for, postoperative periprosthetic femoral fracture (POPFF) after total hip arthroplasty (THA) with either a collared cementless (CC) femoral component or a cemented polished taper-slip (PTS) femoral component.

Methods

We performed a retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All POPFFs were identified using regional radiograph archiving and electronic care systems.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 1 - 1
1 Apr 2022
Karayiannis P Agus A Bryce L Hill J Beverland D
Full Access

Tranexamic Acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomised control trial aimed to assess if an additional 24 hours of TXA post – operatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date this trial included high risk patients. This paper presents the results of a cost analysis undertaken alongside this RTC.

TRAC-24 was a prospective randomised controlled trial on patients undergoing TKA and THA. Three groups were included, Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour post-operative oral regime, group 2 received only the perioperative dose and group 3 did not receive TXA. Cost analysis was performed out to day 90.

Group 1 was associated with the lowest mean total costs, followed by group 2 and then group 3. The difference between groups 1 and 3 −£797.77 (95% CI −1478.22, −117.32) were statistically significant. Extended oral dosing reduced costs for patients undergoing THA but not TKA. The reduced costs in groups 1 and 2 resulted from reduced length of stay, readmission rates, Accident and Emergency (A&E) attendances and blood transfusions.

This study demonstrated significant cost savings when using TXA in primary THA or TKA. Extended oral dosing reduced costs further in THA but not TKA.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 7 - 7
1 Nov 2021
Morlock M Bätz J Beverland D Board T Lampe F Konow T
Full Access

The influence of the surgical process on implant loosening and periprosthetic fractures (PPF) as major complications in uncemented total hip arthroplasty (THA) have rarely been studied due to the difficult quantification. Meanwhile registry analyses have clearly shown a decrease in complications with increasing experience. The goal of this study was to determine the extent of variability in THA stem implantation between highly experienced surgeons with respect to implant-size, -position, press-fit, contact area, primary stability and the effect of using a powered impaction tool.

Primary hip stems were implanted in 16 cadaveric femur pairs by three experienced surgeons using manual and powered impaction. Quantitative CTs were taken before and after each process step and stem tilt, canal-fill-ratio, pressfit and contact area between bone and implant determined. 11 femur pairs were additionally tested for primary stability under cyclic loading conditions.

Higher variations in press-fit and contact area between the surgeons for manual impactions compared to powered were observed. Stem tilt and implant sizing varied between surgeons but not between impaction methods. Larger stems exhibited less micromotion compared to smaller stems.

Larger implants may increase PPF risk, while smaller implants reduce primary stability. The reduced variation for powered impactions indicates that appropriate measures may promote a more standardized process. The observed variations between the experienced surgeons may represent the acceptable range for this specific stem design. Variability in the implantation process warrants further investigations since certain deviations e.g. a stem tilt towards varus, might increase bone stresses and PPF risk.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1197 - 1205
1 Jul 2021
Magill P Hill JC Bryce L Martin U Dorman A Hogg R Campbell C Gardner E McFarland M Bell J Benson G Beverland D

Aims

A typical pattern of blood loss associated with total hip arthroplasty (THA) is 200 ml intraoperatively and 1.3 l in the first 48 postoperative hours. Tranexamic acid (TXA) is most commonly given as a single preoperative dose only and is often withheld from patients with a history of thromboembolic disease as they are perceived to be “high-risk” with respect to postoperative venous thromboembolism (VTE). The TRanexamic ACid for 24 hours trial (TRAC-24) aimed to identify if an additional 24-hour postoperative TXA regime could further reduce blood loss beyond a once-only dose at the time of surgery, without excluding these high-risk patients.

Methods

TRAC-24 was a prospective, phase IV, single centre, open label, parallel group, randomized controlled trial (RCT) involving patients undergoing primary unilateral elective THA. The primary outcome measure was the indirect calculated blood loss (IBL) at 48 hours. The patients were randomized into three groups. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional oral regime for 24 hours postoperatively, group 2 only received the intraoperative dose, and group 3 did not receive any TXA.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 22 - 22
1 Jul 2020
Mayne A Cassidy R Magill P Diamond O Beverland D
Full Access

Introduction

Previous research has demonstrated increased early complication rates following total hip arthroplasty in obese patients, as defined by body mass index (BMI). Subcutaneous fat depth has been shown to be an independent risk factor for wound infection in cervical and lumbar spine surgery as well as after abdominal laparotomy. The aim of this study was to investigate whether increased peri-trochanteric fat depth was associated with increased risk of early complication following total hip arthroplasty.

Methods

We analysed prospectively collected data on a consecutive series of 1220 patients undergoing primary total hip arthroplasty from June 2013 until May 2018. The vertical soft tissue depth from the most prominent part of the greater trochanter to the skin was measured using a sterile ruler and recorded to the nearest millimetre. BMI was calculated at the patient's pre-operative assessment review. All complications (infection, dislocation and peri-prosthetic fracture) occuring within the initial 12 month follow-up were identified.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 11 - 11
1 Jul 2020
Magill P Hill J Bryce L Dorman A Hogg R Campbell C Benson G Beverland D
Full Access

Background

91% of blood loss in Total Hip Replacement (THR) occurs in the period after skin closure and the first 24 post-operative hours. TRAC-24 was established to identify if an additional 24-hour post-operative oral regime of Tranexamic acid (TXA) is superior to a once-only intravenous dose at surgery.

Methods

This was a prospective, phase IV, single centered, open label, parallel group controlled trial on patients undergoing primary elective THR. A history of thromboembolic or cardiovascular disease were not exclusion criteria. The primary outcome was indirect calculated blood loss at 48 hours (IBL). 534 patients were randomized on a 2:2:1 ratio over three different groups. Group 1 received an intravenous dose of TXA at the time of surgery and an additional 24-hour post-operative oral regime, Group 2 only received the intra-operative dose and Group 3 did not receive any TXA.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 19 - 19
1 May 2018
McMahon S Magill P Bopf D Beverland D
Full Access

Introduction

Radiological inclination (RI) is determined in part by operative inclination (OI), which is defined as the angle between the cup axis or handle and the sagittal plane. In lateral decubitus the theatre floor becomes a surrogate for the pelvic sagittal plane.

Critically at the time of cup insertion if the pelvic sagittal plane is not parallel to the floor either because the upper hemi pelvis is internally rotated or adducted, RI can be much greater than expected. We have developed a simple Pelvic Orientation Device (POD) to help achieve a horizontal pelvic sagittal plane.

The POD is a 3-sided square with flat footplates that are placed against the patient's posterior superior iliac spines following initial positioning (figure 1). A digital inclinometer is then placed parallel and perpendicular to the patient to give readings of internal rotation and adduction, which can then be corrected.

Methods

A model representing the posterior aspect of the pelvis was created. This permitted known movement in two planes to simulate internal rotation and adduction of the upper hemi pelvis, with 15 known pre-set positions. 20 participants tested the POD in 5 random, blinded position combinations, providing 200 readings.

The accuracy was measured by subtracting each reading from the known value.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 72 - 72
1 Jan 2018
O'Connor J Hill J Beverland D Dunne N Lennon A
Full Access

This study aimed to assess the effect of flexion and external rotation on measurement of femoral offset (FO), greater trochanter to femoral head centre (GT-FHC) distance, and neck shaft angle (NSA). Three-dimensional femoral shapes (n=100) were generated by statistical shape modelling from 47 CT-segmented right femora. Combined rotations in the range of 0–50° external and 0–50° flexion (in 10° increments) were applied to each femur after they were neutralised (defined as neck and proximal shaft axis parallel with detector plane). Each shape was projected to create 2D images representing radiographs of the proximal femora.

As already known, external rotation resulted in a significant error in measuring FO but flexion alone had no impact. Individually, neither flexion nor external rotation had any impact on GT-FHC but, for example, 30° of flexion combined with 50°of external rotation resulted in an 18.6mm change in height. NSA averaged 125° in neutral with external rotation resulting in a moderate increase and flexion on its own a moderate decrease. However, 50° degrees of both produced an almost 30 degree increase in NSA.

In conclusion, although the relationship between external rotation and FO is appreciated, the impact of flexion with external rotation is not. This combination results in apparent reduced FO, a high femoral head centre and an increased NSA. Femoral components with NSAs of 130° or 135° may historically have been based on X-ray misinterpretation. This work demonstrates that 2D to 3D reconstruction of the proximal femur in pre-op planning is a challenge.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 11 - 11
1 Jun 2017
O'Connor J Rutherford M Hill J Beverland D Dunne N Lennon A
Full Access

Unknown femur orientation during X-ray imaging may cause inaccurate radiographic measurements. The aim of this study was to assess the effect of 3D femur orientation during radiographic imaging on the measurement of greater trochanter to femoral head centre (GT-FHC) distance.

Three-dimensional femoral shapes (n=100) of unknown gender were generated using a statistical shape model based on a training data of 47 CT segmented femora. Rotations in the range of 0° internal to 50° external and 50° of flexion to 0° of extension (at 10 degree increments) were applied to each femur. A ray tracing algorithm was then used to create 2D images representing radiographs of the femora in known 3D orientations. The GT-FHC distance was then measured automatically by identifying the femoral head, shaft axis and tip of greater trochanter.

Uniaxial rotations had little impact on the measurement with mean absolute error of 0.6 mm and 3.1 mm for 50° for pure external rotation and 50° pure flexion, respectively. Combined flexion and external rotation yielded more significant errors with 10° around each axis introducing a mean error of 3.6 mm and 20° showing an average error of 8.8 mm (Figure 1.). In the cohort we studied, when the femur was in neutral orientation, the tip of greater trochanter was never below the femoral head centre.

Greater trochanter to femoral head centre measurement was insensitive to rotations around a single axis (i.e. flexion or external rotation). Modest combined rotations caused the tip of greater trochanter to appear more distal in 2D and led to deviation from the true value. This study suggests that a radiograph with the greater trochanter appearing below femoral head centre may have been acquired with 3D rotation of the femur.

For any figures or tables, please contact the authors directly by clicking on ‘Info & Metrics’ above to access author contact details.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 11 - 11
1 Jun 2016
O'Neill C Molloy D Patterson C Beverland D
Full Access

Introduction

Radiological Inclination (RI) is defined as the angle formed between the acetabular axis and the longitudinal axis when projected onto the coronal plane. Higher RI angles are associated with adverse outcomes.

Methods

Primary aim: to investigate the effect of adjusting patient pelvic position in the transverse plane by using a ‘head-down’ (HD) operating table position. This was to determine, when aiming for 35° Apparent Operative Inclination (AOI), which operating table position most accurately achieved a target post-operative RI of 42°.

N=270. Patients were randomised to one of three possible operating table positions:

0°HD (Horizontal),

7°HD, or

Y°HD (Patient Specific Table Position)

Operating table position was controlled using a digital inclinometer. RI was measured using EBRA software.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 34 - 34
1 Jun 2016
Magill P Blaney J Hill J Beverland D
Full Access

Introduction

The results of cementless total hip arthroplasty (THA) vary with data from the UK national Joint Registry being less favourable than that from the Australian registry. The senior author started using a fully cementless THA in 2005 and we aimed to gauge the performance of the implants based on their revision data.

Patients and methods

Between August 2005 and March 2015, 4,802 primary THA (4,309 patients) were performed with a cementless Corail® stem and a cementless Pinnacle® cup. There were 2,086 (43.4%) males and 2,716 (56.6%) females with a median age of 70 years (IQR 13, Range 16–95). There were a number of changes to the surgical technique with respect to the Corail® stem during the ten-year period, which we have categorised as phase 1 and phase 2. We compared the data in the two phases. Data were extracted from a prospectively maintained patient information database.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 32 - 32
1 Nov 2015
O'Neill C Molloy D Patterson C Beverland D
Full Access

Introduction

Operative inclination (OI) is defined as the angle between the acetabular axis and the sagittal plane. With the patient in the true lateral decubitus position, this corresponds to the angle formed between the handle of the acetabular component inserter and the theatre floor intra-operatively.

Patients/Materials & Methods

The primary study aim was to determine which method of acetabular component insertion most accurately allows the surgeon to obtain a target OI of 35o.

270 consecutive patients undergoing cementless THA were randomised to one of three possible methods for acetabular component implantation:

1. Freehand,

2. 35o mechanical alignment guide (MAG), or

3. Digital inclinometer assisted

Two surgeons participated. Target OI was 35o in all cases. OI was measured using a digital inclinometer. For the freehand and MAG cases, the surgeon was blinded to inclinometer readings intra-operatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1021 - 1026
1 Aug 2011
Kalteis T Sendtner E Beverland D Archbold PA Hube R Schuster T Renkawitz T Grifka J

Orientation of the native acetabular plane as defined by the transverse acetabular ligament (TAL) and the posterior labrum was measured intra-operatively using computer-assisted navigation in 39 hips. In order to assess the influence of alignment on impingement, the range of movement was calculated for that defined by the TAL and the posterior labrum and compared with a standard acetabular component position (abduction 45°/anteversion 15°).

With respect to the registration of the plane defined by the TAL and the posterior labrum, there was moderate interobserver agreement (r = 0.64, p < 0.001) and intra-observer reproducibility (r = 0.73, p < 0.001). The mean acetabular component orientation achieved was abduction of 41° (32° to 51°) and anteversion of 18° (−1° to 36°). With respect to the Lewinnek safe zone (abduction 40° ±10°, anteversion 15° ±10°), 35 of the 39 acetabular components were within this zone. However, there was no improvement in the range of movement (p = 0.94) and no significant difference in impingement (p = 0.085).

Alignment of the acetabular component with the TAL and the posterior labrum might reduce the variability of acetabular component placement in total hip replacement. However, there is only a moderate interobserver agreement and intra-observer reliability in the alignment of the acetabular component using the TAL and the posterior labrum. No reduction in impingement was found when the acetabular component was aligned with the TAL and the posterior labrum, compared with a standard acetabular component position.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1581 - 1585
1 Dec 2007
McConway J O’Brien S Doran E Archbold P Beverland D

Between April 1992 and July 2005, 310 posterior lip augmentation devices were used for the treatment of recurrent dislocation of the hip in 307 patients who had received primary total hip replacements (THRs) using Charnley/Charnley Elite components with a cemented acetabulum. The mean number of dislocations before stabilisation with the device was five (1 to 16) with a mean time to this intervention from the first dislocation of 3.8 years (0 days to 22.5 years). The mean age of the patients at this reconstruction was 75.4 years (39 to 96).

A retrospective clinical and radiological review was carried out at a mean follow-up of six years and nine months (4.4 months to 13 years and 7 months). Of the 307 patients, 53 had died at the time of the latest review, with a functioning THR and with the posterior lip augmentation device in situ. There were four revisions (1.3%), one for pain, two for deep infection and one for loosening of the acetabular component. Radiolucent lines around the acetabular component increased in only six cases after insertion of the device which was successful in eliminating instability in 302 patients, with only five further dislocations (1.6%) occurring after its insertion.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 883 - 886
1 Jul 2006
Archbold HAP Mockford B Molloy D McConway J Ogonda L Beverland D

Ensuring the accuracy of the intra-operative orientation of the acetabular component during a total hip replacement can be difficult. In this paper we introduce a reproducible technique using the transverse acetabular ligament to determine the anteversion of the acetabular component. We have found that this ligament can be identified in virtually every hip undergoing primary surgery. We describe an intra-operative grading system for the appearance of the ligament. This technique has been used in 1000 consecutive cases. During a minimum follow-up of eight months the dislocation rate was 0.6%. This confirms our hypothesis that the transverse acetabular ligament can be used to determine the position of the acetabular component. The method has been used in both conventional and minimally-invasive approaches.