The patients were divided into two groups, A and B. The first, Group A, in which only Dynesys was used and the second, Group B, in which Dynesys was used adjacent to one or more fused segments.
The ROM of the end plate angle at the instrumented segments in Group A reduced from 5.72o to 1.44o{difference 4.28o(p=0.005)} and in Group B reduced from 6.00o to 2.17o,{difference 3.83o(p=0.001)}. The ROM of the end plate angle at the level above instrumentation in Group A reduced from 8.2o to 5.1o {reduction 3.1o(p=0.085)}, while in group-B increased from 7.3o to 7.5o, a difference of 0.2o (p=0.877). The mean anterior disc height in Group A reduced by 2.1mm (p<
0.001) from 9.59mm to 7.44mm. The posterior disc height also reduced from 6.56mm to 6.26mm, a difference of 0.3mm, (p=0.434). In Group B, the anterior disc height reduced by 1.98mm (pre-op=9.04mm, post-op= 7.06mm, p=0.001) and the posterior height by 0.35mm (pre-op 6.14mm to post op 5.79mm, p=0.443)
The patients were divided into two groups, A and B. The first, Group A, in which only Dynesys was used and the second, Group B, in which Dynesys was used adjacent to one or more fused segments.
The ROM of the end plate angle at the instrumented segments in Group A reduced from 5.72o to 1.44o{difference 4.28o(p=0.005)} and in Group B reduced from 6.00o to 2.17o,{difference 3.83o(p=0.001)}. The ROM of the end plate angle at the level above instrumentation in Group A reduced from 8.2o to 5.1o {reduction 3.1o(p=0.085)}, while in group-B increased from 7.3o to 7.5o, a difference of 0.2o (p=0.877). The mean anterior disc height in Group A reduced by 2.1mm (p<
0.001) from 9.59mm to 7.44mm. The posterior disc height also reduced from 6.56mm to 6.26mm, a difference of 0.3mm, (p=0.434). In Group B, the anterior disc height reduced by 1.98mm (pre-op=9.04mm, post-op= 7.06mm, p=0.001) and the posterior height by 0.35mm (pre-op 6.14mm to post op 5.79mm, p=0.443)
Thirty patients with were treated with Dynesys system. All had discography and positional MRI preoperatively and nine months post-operatively. The patients were divided in to two groups. The first in which only Dynesys was used and the second in which Dynesys was used with fusion.
The ROM of the end plate angle at the instrumented segments in group-A reduced from 5.24o to 2.18o{difference 3.06o(p<
0.005)} and in group-B reduced from 6.69o to 2.46o,{difference 4.23o(p=0.008)}. The ROM of the end plate angle at adjacent level in group-A changed from 8.26o to 7.0o {reduction 1.26o(p=0.388)},while in group-B increased from 6.91o to 8.64o, {difference 1.73o(p=0.149)} The mean anterior disc height in-group A reduced by 1.43mm (p<
0.005) from 9.75mm to 8.32mm, and the posterior one was increased from 6.27mm to 6.77mm {difference of 0.5mm,(p=0.008)}. In group-B the anterior disc height reduced by 1.11mm (pre-op=10.44mm,post-op= 9.33mm,p=0.049) and the posterior one by 0.16mm (pre-op 6.98mm to post-op 6.82mm,p=0.714).
The patients were divided into two groups. The Group-A with 14 patients in which only Dynesys was used and Group-B with 11 patients in which Dynesys was combined with fused levels. The operated levels were 51, 13 of which were fused. The results showed that the mean range of movement of the lumbosacral angle reduced by 10.28° (Preop=39.21°, Postop=28.93°) (p=0.016) in group-A. In group-B it reduced by 13.73° (Preop=36.18°, Postop=22.45°) (p=0.02). The range of movement of the end plate angle at the instrumented segments in group-A reduced by 2.96° (Preop=5.56°, Postop=2.60°) (p=0.016) while in group-Bit reduced by 4.23° (Preop=6.69°, Postop=2.46°)(p=0.008). The mean range of movement of the end plate angle at adjacent level in group-A reduced by 1.58° (Preop=8.7°, Postop=7.21°)(p=0.427) while in group-B it increased by 1.73° (Preop=6.91°, Postop=8.64°) (p=0.149) The mean anterior disc height in group-A reduced by 1.18mm (Preop=10.05mm, Postop=8.87mm) (p<
0.005), and the posterior one was increased by 0.6mm (Preop=6.51mm, Postop=8.87mm) (p=0.013). In group-B, the anterior disc height was reduced by 1.11mm (Preop= 10.44mm, Postop=9.33mm) (p=0.049) and the posterior one by 0.16mm (Preop=6.98mm Postop=6.82mm) (p=0.714)
This study measures the changes in the lumbar spine in different postures, pre- and after insertion of the device.
All had a positional MRI preoperatively and nine months post-operatively in flexion-extension-lateral bending. The patients were divided in to two groups: Group(A) with 8 patients in which Dynesys was used with fusion (disc-height<
40 %) Group(B) with 12 patients was the Dynesys-only group (disc-height=40–90%).
The changes in the anterior disc height was (mean= −1.18)(p<
0.05) and to the posterior (mean=0.37)(p=0.134). In bending were (mean=−0.87°)(p=0.18) for left and (mean=−0.24°)(p=0.75) for the right