Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 3 - 3
1 Oct 2021
Farrow L Redmore J Talukdar P Ashcroft G
Full Access

One potential approach to addressing the current hip and knee arthroplasty backlog is via adoption of surgical prioritisation methods, such as use of pre-operative health related quality of life (HRQOL) assessment. We set out to determine whether dichotomization using a previously identified bimodal EuroQol Five-Dimension (EQ-5D) distribution could be used to triage waiting lists.

516 patients had data collected regarding demographics, perioperative variables and patient reported outcome measures (pre-operative & 1-year post-operative EQ-5D-3L and Oxford Hip and Knee Scores (OHS/OKS). Patients were split into two equal groups based on pre-operative EQ-5D Time Trade-Off (TTO) scores and compared (Group1 [worse HRQOL] = −0.239 to 0.487; Group2 [better HRQOL] = 0.516 to 1 (best)). The EQ5D TTO is a widely used and validated HRQOL measure that generates single values for different combinations of health-states based upon how individuals compare x years of healthy living to x years of illness.

We identified that those in Group1 had significantly greater improvement in post-operative EQ-5D TTO scores compared to Group2 (Median 0.67vs.0.19; p<0.0001 respectively), as well as greater improvement in OHS/OKS (Mean 22.4vs16.4; p<0.0001 respectively). Those in Group2 were significantly less likely to achieve EQ-5D MCID attainment (OR 0.13, 95%CI 0.07–0.23; p<0.0001) with a trend towards lower OHS/OKS MCID attainment (OR 0.66, 95%CI 0.37–1.19; p=0.168). There was no statistically significant difference in adverse events.

These finding suggest that a pre-operative EQ-5D cut-off of ≤0.487 for hip and knee arthroplasty prioritisation may help to maximise clinical utility and cost-effectiveness in a limited resource setting post COVID-19.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 11 - 11
1 May 2021
Skipsey DA Downing MR Ashcroft GP Cairns DA Kumar K
Full Access

Over the last decade stemless shoulder arthroplasty has become increasingly popular. However, stability of metaphyseal loading humeral components remains a concern. This study aimed to assess the stability of the Affinis stemless humeral component using Radiostereometric analysis (RSA).

Patients underwent total shoulder arthroplasty via a standardised technique with a press-fit stemless humeral component and a cemented pegged glenoid. Tantalum beads were inserted into the humerus at the time of operation. RSA of the relaxed shoulder was completed at weeks 1, 6, 13, 26, 52 and 104 post-operatively. Stressed RSA with 12 newtons of abduction force was completed from week 13 onwards. ABRSA 5.0 software (Downing Imaging Limited, Aberdeen) was used to calculate humeral component migration and induced movement.

15 patients were recruited. Precision was: 0.041, 0.034, 0.086 and 0.101 mm for Superior, Medial, Posterior and Total Point Motion (TPM) respectively. The mean TPM over 2 years was 0.24 (0.30) mm, (Mean (Standard deviation)). The mean rate of migration per 3 month time period decreased from 0.45 (0.31) to 0.02 (0.01) mm over 2 years. Mean inducible movement TPM peaked at 26 weeks at 0.1 (0.08) mm, which reduced to 0.07 (0.06) mm by 104 weeks when only 3 patients had measurable inducible motion. There was no clear trend in direction of induced movement. There were no adverse events or revisions required.

We conclude migration of the humeral component was low with little inducible movement in the majority of patients implying initial and 2 year stability of the stemless humeral component.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_V | Pages 4 - 4
1 Mar 2012
Karuppiah S Downing M Broadbent R Christie M Carnegie C Ashcroft G Johnstone A
Full Access

Due to its popularity of intramedullary nails (IMN) high success rate, newer design (titanium) IMN system have been introduced to replace stainless steel system. However the stability provided by the titanium IMN

may not be adequate, there by influencing the union rate.

We aimed to compare the results of both IMN systems via prospective clinical study and biomechanical testing using RSA.

Biomechanical study

This study was done in an experimental set-up which consisted of a physically simulated femoral shaft fractures models fixed with a stainless steel (Russell Taylor) or Titanium (Trigen) IM nailing system. Two common fracture configurations with stimulated weight bearing conditions were used and the axis of fragment movements recorded.

Clinical study

The data on two groups of patients were collected as part of a prospective cohort study. Details of the implant, such as size of nail, cross screw lengths, screw thickness, etc. was collected. Patients were followed up for a minimum of 4 months and details of clinical complications recorded