Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 70 - 70
19 Aug 2024
Heimann AF Kowal JH Lane PM Amundson AJ Tannast M Murphy SB
Full Access

Mixed Reality has the potential to improve accuracy and reduce required dissection for the performance of peri-acetabular osteotomy. The current work assesses initial proof of concept of MR guidance for PAO.

A PAO planning module, based on preoperative computed tomography (CT) imaging, allows for the planning of PAO cut planes and repositioning of the acetabular fragment. 3D files (holograms) of the cut planes and native and planned acetabulum positions are exported with the associated spatial information. The files are then displayed on mixed reality head mounted device (HoloLens2, Microsoft) following intraoperative registration using an FDA-cleared mixed reality application designed primary for hip arthroplasty (HipInsight). PAO was performed on both sides of a bone model (Pacific Research). The osteotomies and acetabular reposition were performed in accordance with the displayed holograms. Post-op CT imaging was performed for analysis. Cutting plane-accuracy was evaluated using a best-fit plane and 2D angles (°) between the planned and achieved supra (SA)- and retroacetabular (RA) osteotomy and retroacetabular and ischial osteotomies (IO) were measured.

To evaluate the accuracy of acetabular reorientation, we digitized the acetabular rim and calculated the acetabular opening plane. Absolute errors of planned and achieved operative inclination and anteversion (°) of the acetabular fragment, as well as 3D lateral-center-edge (LCE) angles were calculated.

The mean absolute difference between the planned and performed osteotomy angles was 3 ± 3°.

The mean absolute error between planned and achieved operative anteversion and inclination was 1 ± 0° and 0 ± 0° respectively. Mean absolute error between planned and achieved 3D LCE angle was 0.5 ± 0.7°.

Mixed-reality guidance for the performance of pelvic osteotomies and acetabular fragment reorientation was feasible and highly accurate. This solution may improve the current standard of care by enabling reliable and precise reproduction of the desired acetabular realignment.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 168 - 181
14 Mar 2023
Dijkstra H Oosterhoff JHF van de Kuit A IJpma FFA Schwab JH Poolman RW Sprague S Bzovsky S Bhandari M Swiontkowski M Schemitsch EH Doornberg JN Hendrickx LAM

Aims

To develop prediction models using machine-learning (ML) algorithms for 90-day and one-year mortality prediction in femoral neck fracture (FNF) patients aged 50 years or older based on the Hip fracture Evaluation with Alternatives of Total Hip arthroplasty versus Hemiarthroplasty (HEALTH) and Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trials.

Methods

This study included 2,388 patients from the HEALTH and FAITH trials, with 90-day and one-year mortality proportions of 3.0% (71/2,388) and 6.4% (153/2,388), respectively. The mean age was 75.9 years (SD 10.8) and 65.9% of patients (1,574/2,388) were female. The algorithms included patient and injury characteristics. Six algorithms were developed, internally validated and evaluated across discrimination (c-statistic; discriminative ability between those with risk of mortality and those without), calibration (observed outcome compared to the predicted probability), and the Brier score (composite of discrimination and calibration).


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 859 - 866
1 Jul 2022
Innocenti M Smulders K Willems JH Goosen JHM van Hellemondt G

Aims

The aim of this study was to explore the relationship between reason for revision total hip arthroplasty (rTHA) and outcomes in terms of patient-reported outcome measures (PROMs).

Methods

We reviewed a prospective cohort of 647 patients undergoing full or partial rTHA at a single high-volume centre with a minimum of two years’ follow-up. The reasons for revision were classified as: infection; aseptic loosening; dislocation; structural failure; and painful THA for other reasons. PROMs (modified Oxford Hip Score (mOHS), EuroQol five-dimension three-level health questionnaire (EQ-5D-3L) score, and visual analogue scales for pain during rest and activity), complication rates, and failure rates were compared among the groups.


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1035 - 1042
1 Dec 2021
Okowinski M Hjorth MH Mosegaard SB Jürgens-Lahnstein JH Storgaard Jakobsen S Hedevang Christensen P Kold S Stilling M

Aims

Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes.

Methods

A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 926 - 931
9 Nov 2021
Houdek MT Wyles CC Smith JH Terzic A Behfar A Sierra RJ

Aims

Bone marrow-derived mesenchymal stem cells obtained from bone marrow aspirate concentrate (BMAC) with platelet-rich plasma (PRP), has been used as an adjuvant to hip decompression. Early results have shown promise for hip preservation in patients with osteonecrosis (ON) of the femoral head. The purpose of the current study is to examine the mid-term outcome of this treatment in patients with precollapse corticosteroid-induced ON of the femoral head.

Methods

In all, 22 patients (35 hips; 11 males and 11 females) with precollapse corticosteroid-induced ON of the femoral head underwent hip decompression combined with BMAC and PRP. Mean age and BMI were 43 years (SD 12) and 31 kg/m² (SD 6), respectively, at the time of surgery. Survivorship free from femoral head collapse and total hip arthroplasty (THA) and risk factors for progression were evaluated at minimum five-years of clinical follow-up with a mean follow-up of seven years (5 to 8).


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 832 - 837
1 Jul 2020
Dover C Kuiper JH Craig P Shaylor P

Aims

We have previously demonstrated raised cobalt and chromium levels in patients with larger diameter femoral heads, following metal-on-polyethylene uncemented total hip arthroplasty. Further data have been collected, to see whether these associations have altered with time and to determine the long-term implications for these patients and our practice.

Methods

Patients from our previous study who underwent Trident-Accolade primary total hip arthroplasties using a metal-on-polyethylene bearing in 2009 were reviewed. Patients were invited to have their cobalt and chromium levels retested, and were provided an Oxford Hip Score. Serum ion levels were then compared between groups (28 mm, 36 mm, and 40 mm heads) and over time.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 443 - 449
1 Apr 2018
Kalsbeek JH van Walsum ADP Vroemen JPAM Janzing HMJ Winkelhorst JT Bertelink BP Roerdink WH

Aims

The objective of this study was to investigate bone healing after internal fixation of displaced femoral neck fractures (FNFs) with the Dynamic Locking Blade Plate (DLBP) in a young patient population treated by various orthopaedic (trauma) surgeons.

Patients and Methods

We present a multicentre prospective case series with a follow-up of one year. All patients aged ≤ 60 years with a displaced FNF treated with the DLBP between 1st August 2010 and December 2014 were included. Patients with pathological fractures, concomitant fractures of the lower limb, symptomatic arthritis, local infection or inflammation, inadequate local tissue coverage, or any mental or neuromuscular disorder were excluded. Primary outcome measure was failure in fracture healing due to nonunion, avascular necrosis, or implant failure requiring revision surgery.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 762 - 770
1 Jun 2015
Pennington MW Grieve R van der Meulen JH

There is little evidence on the cost effectiveness of different brands of hip prostheses. We compared lifetime cost effectiveness of frequently used brands within types of prosthesis including cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed) and hybrid (Exeter V40 Trilogy, Exeter V40 Trident, and CPT Trilogy). We used data from three linked English national databases to estimate the lifetime risk of revision, quality-adjusted life years (QALYs) and cost.

For women with osteoarthritis aged 70 years, the Exeter V40 Elite Plus Ogee had the lowest risk of revision (5.9% revision risk, 9.0 QALYs) and the CPT Trilogy had the highest QALYs (10.9% revision risk, 9.3 QALYs). Compared with the Corail Pinnacle (9.3% revision risk, 9.22 QALYs), the most commonly used brand, and assuming a willingness-to-pay of £20 000 per QALY gain, the CPT Trilogy is most cost effective, with an incremental net monetary benefit of £876. Differences in cost effectiveness between the hybrid CPT Trilogy and Exeter V40 Trident and the cementless Corail Pinnacle and Taperloc Exceed were small, and a cautious interpretation is required, given the limitations of the available information.

However, it is unlikely that cemented brands are among the most cost effective. Similar patterns of results were observed for men and other ages. The gain in quality of life after total hip arthroplasty, rather than the risk of revision, was the main driver of cost effectiveness.

Cite this article: Bone Joint J 2015;97-B:762–70.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 578 - 582
1 May 2013
Kim S Postigo R Koo S Kim JH

The timing of total hip replacement (THR) in patients with active tuberculosis (TB) of the hip is controversial, because of the potential risk of reactivation of infection. There is little information about the outcome of THR in these patients. We conducted a systematic review of published studies that evaluated the outcome of THR in patients with active TB of the hip. A review of multiple databases referenced articles published between 1950 and 2012. A total of six articles were identified, comprising 65 patients. TB was confirmed histologically in all patients. The mean follow-up was 53.2 months (24 to 108). Antituberculosis treatment continued post-operatively for between six and 15 months, after debridement and THR. One non-compliant patient had reactivation of infection. At the final follow-up the mean Harris hip score was 91.7 (56 to 98). We conclude that THR in patients with active TB of the hip is a safe procedure, providing symptomatic relief and functional improvement if undertaken in association with extensive debridement and appropriate antituberculosis treatment.

Cite this article: Bone Joint J 2013;95-B:578–82.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 646 - 649
1 Jul 2003
Sterling GJ Crawford S Potter JH Koerbin G Crawford R

We prospectively investigated a consecutive series of ten patients undergoing a cemented primary total hip replacement (THR) for osteoarthritis in order to establish the elution characteristics of Simplex-tobramycin bone cement (Howmedica, Limerick, Ireland). Specimens of blood, urine and drainage fluid were collected for 72 hours postoperatively. Very high concentrations of tobramycin were found in the drainage fluid, with mean levels at one hour of 103 mg/l, which steadily declined to 15.1 mg/l after 48 hours. The mean serum tobramycin levels reached a peak of 0.94 mg/l at three hours and declined rapidly to 0.2 mg/l by 48 hours. The mean urinary tobramycin levels peaked at 57.8 mg/l at 12 hours with a rapid decline to 12.6 mg/l by 24 hours.

There was a direct correlation between the amount of tobramycin bone cement which was implanted and the amount of tobramycin systemically absorbed. Excellent local delivery was achieved with minimal systemic concentrations. Simplex-tobramycin bone cement is an efficient and safe method for the delivery of antibiotics after THR.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 440 - 443
1 May 1999
Scott CP Higham PA Dumbleton JH

We used 99 strains of organisms representative of orthopaedic infections to examine the effectiveness of a bone cement containing tobramycin, employing a modified in vitro Kirby-Bauer susceptibility model. The spectrum was broad, including Gram-positive and Gram-negative aerobic organisms, anaerobes and mycobacteria. Simplex P with added tobramycin was effective against most of the strains, including those which are resistant to typical systemic levels of tobramycin. Although direct correlation between in vitro and in vivo results is difficult, the study showed that tobramycin is stable to the exothermic polymerisation of the cement, and that it is released from the surface of the cement at concentrations high enough to inhibit the growth of most organisms which may be encountered after joint arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 954 - 958
1 Nov 1998
Kim Y Ahn JH Kang HS Kim HJ

The extent of necrosis is the main determining factor in the outcome of osteonecrosis of the femoral head and is best measured by MRI.

Using statistical analyses, we have evaluated the accuracy and repeatability of seven different methods of measuring the extent of necrosis, of which three demonstrate good or acceptable accuracy. For the general observer their repeatability is poor; only for experienced observers were they reasonable. We conclude that within an institution or for personal use, the accuracy of some methods is acceptable, and repeatability reasonable. None is appropriate for international use.