Introduction. On the basis of a proposal by Noble, the marrow cavity form can be classified into three categories: stovepipe, normal, and champagne-fluted. In the present study, three typical finite element femoral models were created using CT data based on Noble's three categories. The purpose was to identify the relationship of stress distribution of the surrounding areas between femoral bone marrow cavity form and hip stem. The results shed light on whether the distribution of the high-stress area reflects the stem design concept. In order to improve the results of THA, researchers need to consider the instability of a stem design based on the pressure zone and give feedback on future stem selection. Methods. To develop finite element models, two parts (cortical bone and stem) were constructed using four-node tetrahedral elements. The model consisted of about 40,000 elements. The material characteristics were defined by the combination of mass density, elastic coefficient, and Poisson's ratio. Concerning the analysis system, HP Z800 Workstation(HP, Japan) was used as hardware and LS-DYNA Ver. 971 (Livermore Software Technology Corporation, USA) as software. The distal end of the femur was constrained in all directions. On the basis of ISO 7206 Part 4,8 that specifies a method of endurance testing for joint prostheses, the stem was tilted 10°, and a 500 N resultant force in the area around the hip joint was applied to the head at an angle of 25° with the long axis. Automatic contact with a consideration of slip was used.
Aims. There is ambiguity surrounding the degree of scaphoid union required to safely allow mobilization following scaphoid waist fracture. Premature mobilization could lead to refracture, but late mobilization may cause stiffness and delay return to normal function. This study aims to explore the risk of refracture at different stages of scaphoid waist fracture union in three common fracture patterns, using a novel finite element method. Methods. The most common anatomical variant of the scaphoid was modelled from a CT scan of a healthy hand and wrist using 3D Slicer freeware. This model was uploaded into COMSOL Multiphysics software to enable the application of physiological enhancements. Three common waist fracture patterns were produced following the Russe classification. Each fracture had differing stages of healing, ranging from 10% to 90% partial union, with increments of 10% union assessed. A physiological force of 100 N acting on the distal pole was applied, with the risk of refracture assessed using the
Aims. This study aimed to identify the effect of anatomical tibial component (ATC) design on load distribution in the periprosthetic tibial bone of Koreans using finite element analysis (FEA). Methods. 3D finite element models of 30 tibiae in Korean women were created. A symmetric tibial component (STC, NexGen LPS-Flex) and an ATC (Persona) were used in surgical simulation. We compared the FEA measurements (von Mises stress and principal strains) around the stem tip and in the medial half of the proximal tibial bone, as well as the distance from the distal stem tip to the shortest anteromedial cortical bone. Correlations between this distance and FEA measurements were then analyzed. Results. The distance from the distal stem tip to the shortest cortical bone showed no statistically significant difference between implants. However, the peak
Aims. The material and design of knee components can have a considerable effect on the contact characteristics of the tibial post. This study aimed to analyze the stress distribution on the tibial post when using different grades of polyethylene for the tibial inserts. In addition, the contact properties of fixed-bearing and mobile-bearing inserts were evaluated. Methods. Three different grades of polyethylene were compared in this study; conventional ultra high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (HXLPE), and vitamin E-stabilized polyethylene (VEPE). In addition, tibial baseplates with a fixed-bearing and a mobile-bearing insert were evaluated to understand differences in the contact properties. The inserts were implanted in neutral alignment and with a 10° internal malrotation. The contact
Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA. This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.Aims
Methods
Aims. Osteolysis, secondary to local and systemic physiological effects, is a major challenge in total hip arthroplasty (THA). While osteolytic defects are commonly observed in long-term follow-up, how such lesions alter the distribution of stress is unclear. The aim of this study was to quantitatively describe the biomechanical implication of such lesions by performing subject-specific finite-element (FE) analysis on patients with osteolysis after THA. Patients and Methods. A total of 22 hemipelvis FE models were constructed in order to assess the transfer of load in 11 patients with osteolysis around the acetabular component of a THA during slow walking and a fall onto the side. There were nine men and two women. Their mean age was 69 years (55 to 81) at final follow-up. Changes in peak stress values and loads to fracture in the presence of the osteolytic defects were measured. Results. The
Introduction. Osteoarthritis (OA), a painful, debilitating joint disease, often caused by excessive joint stress, is a leading cause of disability (World Health Organisation, 2003) and increases with age and obesity. A 5° varus malalignment increases loading in the medial knee compartment from 70% to 90% (Tetsworth and Paley, 1994). Internal unloading implants, placed subcutaneously upon the medial aspect of the knee joint, are designed to offload the medial compartment of the knee without violating natural joint tissues. The aim of this study is to investigate the effect of an unloading implant, such as the Atlas™ knee system, on stress within the tibiofemoral joint with different grades of cartilage defects. Methods. To simulate surgical treatment of medial knee OA, a three-dimensional computer-aided design of an Atlas™ knee system was virtually fixed to the medial aspect of a validated finite element knee model (Mootanah, 2014), using CATIA v5 software (Dassault Systèmes, Velizy Villacoublay, France). The construct was meshed and assigned material properties and boundary conditions, using Abaqus finite element software (Dassault Systèmes, Velizy Villacoublay, France). A cartilage defect was simulated by removing elements corresponding to 4.7 mm. 2. The international cartilage repair society (ICRS) Grade II and III damage were simulated by normalized defect depth of 33% and 67%, respectively. The femur was mechanically grounded and the tibia was subjected to loading conditions corresponding to the stance phase of walking of a healthy 50-year-old 68-Kg male with anthropometrics that matched those of the cadaver. Finite element analyses were run for peak shear and
Objectives. Elevated proximal tibial bone strain may cause unexplained pain, an important cause of unicompartmental knee arthroplasty (UKA) revision. This study investigates the effect of tibial component alignment in metal-backed (MB) and all-polyethylene (AP) fixed-bearing medial UKAs on bone strain, using an experimentally validated finite element model (FEM). Methods. A previously experimentally validated FEM of a composite tibia implanted with a cemented fixed-bearing UKA (MB and AP) was used. Standard alignment (medial proximal tibial angle 90°, 6° posterior slope), coronal malalignment (3°, 5°, 10° varus; 3°, 5° valgus), and sagittal malalignment (0°, 3°, 6°, 9°, 12°) were analyzed. The primary outcome measure was the volume of compressively overstrained cancellous bone (VOCB) < -3000 µε. The secondary outcome measure was maximum
Femoral head collapse is a possible complication after surgical treatment of femoral neck fractures. The purpose of this study was to examine whether implantation of a Sliding Hip Screw (SHS) or an X-Bolt could increase the risk of femoral head collapse. Similar to traditional hip screws, the X-Bolt is implanted through the femoral neck; however, it uses an expanding cross-shape to improve rotational stability. The risk of collapse was investigated alongside patient factors, such as osteonecrosis. This numerical study assessed the risk of femoral head collapse using linear eigenvalue buckling (an established method [1]), and also from the maximum
Background. Several studies have reported that tibial component in varus alignment can worsen the survivorship of medial unicompartmental knee arthroplasty (UKA). On the other hand, Varus/valgus inclination of the tibial component can affect the location of the contact point between femoral and tibial component especially in round on flat bearing surface design. Along with the tibial component inclination, changes in the contact point may also alter the tibial condylar bone stress, which would affect the longevity or complications after UKA. Method. We constructed a validated three-dimensional finite element model of the tibia with a medial component and assessed stress concentrations by changing the tibial component coronal inclinations (squale inclination, 3° and 6° varus, 3° and 6° valgus inclination). We evaluated the
Introduction. Relative motion at the modular head-neck junction of hip prostheses can lead to severe surface damage through mechanically-assisted corrosion. One factor affecting the mechanical performance of modular junctions is the frictional resistance of the mating surfaces to relative motion. Low friction increasing forces normal to the head-neck interface, leading to a lower threshold for slipping during weight-bearing. Conversely, a high friction coefficient is expected to limit interface stresses but may also allow uncoupling of the interface in service. This study was performed to examine this trade-off using finite element models of the modular head-neck junction. Methods. A finite element model (FEM) of the trunnion/ head assembly of a total hip prosthesis was initially created and experimentally validated. CAD models of a stem trunnion (taper size: 12/14mm) and a prosthetic femoral head (diameter: 28mm) were discretized into elements for finite element analysis (FEA). The trunnion (Ti6Al4V) was modelled with a hexahedral mesh (33,648 elements) and the femoral head (CoCrMo) with a tetrahedral mesh (51,182 elements). A friction-based sliding contact interface was defined between the mating surfaces. The model was loaded in 2 stages: (i) an assembly load of 4000N applied along the trunnion axis, and (ii) 500N applied along the trunnion axis in combination with a torque of 10Nm. A linear static solution was set up using Siemens NX-Nastran solver. Multiple simulations were executed by modulating the frictional coefficient at the taper-bore interface from 0.05 to 0.15 in increments of 0.01, the coefficient of 0.1 serving as the control case (Swaminathan and Gilbert, 2012). Results. The vertical and tangential displacements of the nodes on the taper of the trunnion relative to the femoral head demonstrated a strong inverse dependence upon the coefficient of friction at the interface (Fig. 1). A similar trend was observed with respect to the peak interface pressure (Fig. 2). The peak
Common post-operative problems in shoulder arthroplasty such as glenoid loosening and joint instability can be reduced by improvements in glenoid design shape, material choice and fixation method [1]. Innovation in shoulder replacement is usually carried out by introducing incremental changes to functioning implants [2], possibly overlooking other successful design combinations. We propose an automated framework for parametric analysis of implant design in order to efficiently assess different possible glenoid configurations. Parametric variations of reference geometries of a glenoid implant were automatically generated in SolidWorks. The different implants were aligned and implanted with repeatability using Rhino. The glenoid-bone models were meshed in Abaqus, and boundary conditions and loading applied via a custom-made Python script. Finally, another MATLAB script integrated and automated the different steps, extracted and analysed the results. This study compared the influence of reference shape (keel vs. 2-pegged) and material on the
Introduction. Post cam is useful to realize the intrinsic stability of a posterior-stabilized (PS) knee prosthesis replaced for a case with the severe degeneration. Some retrieval studies reveal the ultrahigh molecular weight polyethylene (UHMWPE) deformation or severe failure of the tibial post of PS knee. Strength of the tibial post of available design is obviously insufficient to prevent the severe deformation. The large size post might, however, shorten the range of knee motion. Therefore, minimally required size of the post should be clarified for polyethylene inserts. In the present study, we performed finite element (FE) analysis assumed the mechanical conditions of a tibial post in a PS knee and aimed to design criterion of a post of polyethylene insert of a knee prosthesis. Method. The shape of three commercially available knee prostheses, product A, B, and C was referred as PS knee prosthesis. The contour of the metallic femoral component and the UHMWPE insert were digitized by a computed tomography apparatus. Three dimensional finite elements were generated by modeling software (Simpleware, Ltd. UK) as four-node tetrahedral elements. In FE analysis, we used LS-DYNA ver.971 (Livemore Software Technology Corp. USA) as the software and Endeaver Pro-4500 (EPSON Corp. Japan) as the hardware. These bottoms of the tibial insert were fully constrained. The value of 30MPa was defined as yield stress of UHMWPE. 500N posterior load was applied to each femoral component at 10 degree hyperextension. Then, 1000N anterior load at 120 degree flexion, after tibial insert was located 10 degree internal rotation (Fig. 1). These loads were assumed to realize the two types of tibial post impingement under several kinds of knee motions. The distributed values of
Statement of purpose: The aim of this study is to evaluate different designs of unicompartmental knee replacement (UKR) by comparing the peak von Mises and contact stresses in polyethylene (PE) bearings over a step-up activity. Summary of Methods: A validated finite element (FE) model was used in this study. Three UKR designs were modelled: a spherical femoral component with a spherical PE bearing (fully-congruent), a poly-radial femoral component with a concave PE bearing (semi-congruent), and a spherical femoral component with a flat bearing (non-congruent). Kinematic data from in-vivo fluoroscopy measurements during a step-up activity was used to determine the relative tibial-femoral position as a function of knee flexion angle for each model. Medial and lateral force distribution was adapted from loads measured in-vivo with an instrumented implant during a step-up activity. The affect that varying the bearing thickness has on the stresses in the bearing was investigated. In addition, varus-valgus mal-alignment was investigated by rotating the femoral component through 10 degrees. Summary of Results: Only the fully congruent bearing experienced peak von Mises and contact stresses below the PE lower fatigue limit (17MPa) for the step-up activity (fully congruent PE peak contact stress, 5MPa). The highest PE contact stresses were observed for the semi-congruent and non-congruent designs, which experienced approximately 3 times the PE lower fatigue limit. Peak PE
Abstract. Background. Proximal fibular osteotomy (PFO) was defined to provide a treatment option for knee pain caused by gonarthrosis(1). Minor surgical procedure, low complication rate and dramatic pain relief were the main reasons for popularization of this procedure(2, 3). However, changes at the knee and ankle joint after PFO were not clarified objectively in the literature. Questions/purposes. We asked: 1) Does PFO change the maximum and average pressures at the medial and lateral chondral surface of the tibia plateau? 2) Are chondral surface stresses redistributed at the knee and ankle joint after PFO? 3)Does PFO change the distribution of total load on the knee joint? 4) Can PFO lead to change in alignment of lower limb?. Methods. This study was conducted at Maltepe University Faculty of Medicine Hospital, Orthopedics and Traumatology Department and Yildiz Technical University Mechanical Engineering Department in Istanbul, Turkey, between September 2019 and February 2020. Finite element analysis (FEA) was used to evaluate effects of PFO(4). One 62 years old, female volunteer's X-ray, computer tomography and magnetic resonance imaging images were used for creating right lower limb model. Two different lower limb models were created. One of them was osteotomized model (OM) which was created according to definition of PFO and the other was non-osteotomized model (NOM). To obtain a stress distribution comparison between the two models, 350 N of axial force was applied to the femoral heads of the models. Results. After PFO, the maximum contact pressures at the medial and lateral tibial cartilages decreased 83.2% and 66.9%, respectively at the knee joint. The average contact pressure decreased 26.1% at the medial tibial cartilage and increased 42.4% at the lateral tibial cartilage. The
Summary Statement. Simulated increases in body weight led to increased displacement,
Introduction. Lipped liners have the potential to decrease the rate of revision for instability after total hip replacement since they increase the jumping distance in the direction of the lip. However, the elevated lip also may reduce the Range of Motion and may lead to early impingement of the femoral stem on the liner. It is unclear whether the use of a lipped liner has an impact on the level of lever-out moments or the contact stresses. Therefore, the aim of the current study was to calculate these values for lipped liners and compare these results to a conventional liner geometry. Materials and Methods. 3D Finite Element studies were conducted comparing a ceramic lipped liner prototype and a ceramic conventional liner both made from BIOLOX. ®. delta. The bearing diameter was 36 mm. To apply loading, a test taper made of titanium alloy was bonded to a femoral head, also made from BIOLOX. ®. delta. Titanium was modeled with a bilinear isotropic hardening law. For the bearing contact a coefficient of friction of both 0.09 or 0.3 was assumed to model a well and poorly lubricated system. Frictionless contact was modeled between taper and liner. Pre-load was varied between 500 N and 1500 N and applied along the taper axis. While keeping pre-load constant, lever-out force was applied perpendicular to the taper axis until subluxation occurred. Liners were fixed at the taper region. Lever-out moment, equivalent plastic strain and
Introduction. The process of wear and corrosion at the head-neck junction of a total hip replacement is initiated when the femoral head and stem are joined together during surgery. To date, the effects of the surface topography of the femoral head and metal stem on the contact mechanics during assembly and thus on tribology and fretting corrosion during service life of the implant are not well understood. Therefore, the objective of this study was to investigate the influence of the surface topography of the metal stem taper on contact mechanics and wear during assembly of the head-neck junction using Finite Element models. Materials and Methods. 2D axisymmetric Finite Element models were developed consisting of a simplified head-neck junction incorporating the surface topography of a threaded stem taper to investigate axial assembly with 1 kN. Subsequently, a base model and three modifications of the base model in terms of profile peak height and plateau width of the stem taper topography and femoral head taper angle were calculated. To account for the wear process during assembly a law based on the Archard equation was implemented. Femoral head was modeled as ceramic (linear-elastic), taper material was either modeled as titanium, stainless steel or cobalt-chromium (all elastic-plastic). Wear volume, contact area, taper subsidence, equivalent plastic strain,
Introduction. Stress shielding of bone around the stem components of total shoulder replacement (TSR) implants can result in bone resorption, leading to loosening and failure. Titanium is an ideal biomaterial for implant stems; however, it is much stiffer than bone. Recent advances in additive manufacturing (AM) have enabled the production of parts with complex geometries from titanium alloys, such as hollow or porous stems. The objective of this computational study is to determine if hollow titanium stems can reduce stress shielding at the proximal humerus. We hypothesize that hollow TSR implant stems will reduce stress shielding in comparison with solid stems and the inner wall thickness of the hollow stem will be a design parameter with a direct effect on bone stresses. Methods. Using a previously developed statistical shape and density model (SSDM) of the humerus based on 75 cadaveric shoulders, a simulated average CT image was created. Using MITK-GEM, the cortical and trabecular bones were segmented from this CT image and meshed with quadratic tetrahedral elements. Trabecular bone was modeled as an isotropic and inhomogeneous material, with the Young's modulus defined element-by-element based on the corresponding CT densities. Cortical bone was assumed isotropic with a uniform Young's modulus of 20 GPa. The Poisson's ratio for all bone was 0.3. The distal humerus was fully constrained. Bone stresses were calculated by performing finite element analyses in ABAQUS with a 320 N force and 2 Nm frictional moment applied to the articular surface of the humeral head, based on an in vivo study during 45 degrees of shoulder abduction. Subsequently, the humeral head was resected and reamed to receive solid- and hollow-stemmed implants with identical external geometries but three different inner wall thicknesses (Figure 1). The identical surrounding bone meshes for the intact and reconstructed bones allowed element-by-element stress comparisons. The volume-weighted average changes in cortical and trabecular bone
Introduction. Originally, the vertical expandable titanium rib (VEPTR™) was developed to treat children with Thoracic insufficiency syndrome secondary to fused ribs and congenital scoliosis. Over the years its usage has widen and is currently being used to treat all etiology of early onset scoliosis (EOS). A major draw back remains the size of the titanium VEPTR™ implant. In keeping with the new trend of chrome-cobalt alloy (CoCr). spinal implants, we set out to explore if redesigning the VEPTR™ was mechanically sound. The aim of this study was twofold. Firstly, we investigate the mechanical properties of a VEPTR™ made with CoCr alloy compared to that of titanium alloy. Secondly we investigated how much we could down size the VEPTR™. Materials & Methods. Finite element analyses were performed on 3 different VEPTR™ designs (rod diameter of 6mm, 5mm and 4mm) subjected to a compressive load of 500N (equivalent to a 50Kg child). For each configuration, two materials, titanium alloy and chrome-cobalt alloy, were used. Maximum