Short
Purpose. The purpose of this study is to evaluate the midterm results of cementless revision total hip arthroplasty (THA) using Wagner Cone Prosthesis. Material and Methods. Between 1996 and 2007, 36 hips in 36 consecutive patients underwent femoral revision THA using Wagner Cone Prosthesis. Among them 28 hips were followed for more than 5 years. The mean age at revision surgery was 57 years and a mean follow-up was 7.6 years. The Paprosky classification system was used for preoperative bone loss evaluation. Clinical results were evaluated using Harris hip scores. For evaluation of the femoral component, radiolucent lines at bone-implant interfaces were evaluated and femoral component vertical subsidence was measured. Heterotopic bone formation and complications were also evaluated. Results. The mean period from 1. st. operation to revision THA was 8.0 years. For the femoral bone loss, in eleven hips bone grafting was done. For the prevention of femoral stem fracture, femoral wiring was done in 12 hips. In eighteen hips acetabular cup revision was done simultaneously and in 5 hips isolated stem revision was done. The mean Harris hip score improved from 52 to 83 at final follow-up. With respect to radiological results all femoral stems showed bone ingrowths, 3 out of 28 (10.7%) femoral stems showed subsidence more than 5 mm. Two patients needed acetabular revision for acetabular loosening during follow up period. There was one patient who complained of anterior thigh pain. One patient had recurrent dislocation and required revision surgery for soft tissue augmentation. Conclusions. We achieved favorable midterm clinical and radiological results for femoral stem revisions using Wagner cone prosthesis. This
Purpose:. In order to acquire good stability of an arthroplasty hip, the proper placement of the implants, which prevents impingement between the stem neck and the socket, is important. In general, the anteversion of the
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different
Abstract. Extended Trochanteric Osteotomy (ETO) improves surgical exposure and aids femoral stem and bone cement removal in Revision Total Hip Replacement (RTHR) surgery. The aim of this study was to identify healing rates and complications of ETO in RTHR. Methods. From 2012 to 2019 we identified patients who underwent ETO for RTHR. Data collected demographics, BMI, diabetes, anticoagulants, indication for ETO, surgical approach, length of ETO and complications. Descriptive analysis of patient demographics, multiple linear regression analysis was performed to assess ETO complications. Results. There were 63 patients with an average age of 69 years. Indications for ETO were aseptic loosening (30), infection (15), periprosthetic fracture (9), recurrent dislocation (5), broken implant (4). There were 44 cemented and 19
While Oxidized Zirconium (OxZr) femoral heads matched with highly cross-linked polyethylene (XLPE) have demonstrated the lowest rate of revision compared to other bearing couples in the Australian National Joint Registry, it has been postulated that these results may, in part, be due to the fact that a single company offers this bearing option with a limited combination of femoral and acetabular prostheses. The purpose of this study was to assess clinical and radiographic outcomes in a matched cohort of total hip replacements (THR) utilizing an identical
In a society whereby the incidence of obesity is increasing and medico-legal implications of treatment failure are more frequently ending with the consulting doctor, clarity is required as to any restrictions placed on common orthopaedic implants by manufacturing companies. The aim of this study was to identify any restrictions placed on the commonly used femoral stem implants in total hip replacement (THR) surgery, by the manufacturers, based on patient weight. The United Kingdom (UK) National Joint Registry (NJR) was used to identify the five most commonly used cemented and
Revision total hip arthroplasty (THA) is a challenging procedure and the removal of well-fixed femoral stems can be compounded by several pitfalls. In such cases, several removal techniques have been presented in the literature. The most commonly used techniques are the transfemoral osteotomy presented by Wagner and the extended trochanteric osteotomy (ETO) described by Younger et al. Both techniques allow the surgeon to have better intraoperative exposure of the fixation surfaces of the solid femoral stems. However, the complication rates such as non-union should not be underestimated. Therefore, it is always a good decision to avoid an ETO if alternative techniques exist. The endofemoral surgical technique is an alternative method for the removal of well-fixed cemented and
Background. Radiostereometric Analysis (RSA) is an accurate measure of implant migration following total joint replacement surgery. Early implant migration predicts later loosening and implant failure, with RSA a proven short-term predictor of long-term survivorship. The proximal migration of an acetabular cup has been demonstrated to be a surrogate measure of component loosening and the associated risk of revision. RSA was used to assess migration of the R3 acetabular component which utilises an enhanced porous ingrowth surface. Migration of the R3 acetabular component was also assessed when comparing the fixation technique of the femoral stems implanted. Methods. Twenty patients undergoing primary total hip arthroplasty were implanted with the R3 acetabular cup. The median age was 70 years (range, 53–87 years). During surgery tantalum markers were inserted into the acetabulum and the outer rim of the polyliner. RSA examinations were performed postoperatively at 4 to 5 days, 6, 12 and 24 months. Data was analysed for fourteen patients to determine the migration of the acetabular cup relative to the acetabulum. Of these fourteen patients, six were implanted with a
As an increasing number of young, active large patients become candidates for total hip replacements, there is an increasingly urgent need to identify arthroplasties that will be durable, highly functional and amenable to possible future successful revision. In an era when cemented femoral stems were the primary implant option, the concept of a surface replacement was attractive and, perhaps, appropriate. However,
Increasing pressure to use rapid recovery care pathways when treating patients undergoing total hip arthroplasty (THA) is evident in current health care systems for numerous reasons. Patient autonomy and health care economics has challenged the ability of THA implants to maintain functional integrity before achieving bony union. Although collared stems have been shown to provide improved axial stability, it is unclear if this stability correlates with activity levels or results in improved early function to patients compared to collarless stems. This study aims to examine the role of implant design on patient activity and implant fixation. The early follow-up period was examined as the majority of variation between implants is expected during this time-frame. Patients (n=100) with unilateral hip OA who were undergoing primary THA surgery were recruited pre-operatively to participate in this prospective randomized controlled trial. All patients were randomized to receive either a collared (n=50) or collarless (n=50)
Revision total hip arthroplasty (THA) is a challenging procedure, especially in cases with well-fixed implants. In such cases, several removal techniques have been presented in the current literature, while the most commonly used techniques are the transfemoral osteotomy or the extended trochanteric osteotomy (ETO). Those techniques allow the surgeon to have a better intra-operative exposure of the fixation surfaces of the solid femoral stems. However, the complication rates such as non-union are not unremarkable. Therefore, it is always a good decision to avoid an ETO if alternative techniques exist. The endofemoral surgical technique is an alternative method for the removal of well-fixed cemented and
Background. Hard-on-hard bearings showed advantages of reduction of wear rates, osteolysis and aseptic loosening in total hip arthroplasty (THA). A new combination of ceramic-on-metal (COM) was developed to compensate the disadvantages of MOM and COC. COM showed good short-term results in vitro and in vivo studies. There was no report of stripe wear and metal ion level elevation. Our study was designed to evaluate the wear pattern of this bearing in early loosening THA. Methods. During January 2009 to December 2010, 121 primary THAs were performed at our institution by single-surgeon, using the same acetabular component and same
As an increasing number of young, active, large patients are becoming candidates for total hip replacements, there is an increasingly urgent need to identify arthroplasties that will be durable, highly functional and amenable to possible future successful revision. In an era when cemented femoral stems were the primary implant option, the concept of a surface replacement was attractive and, perhaps, appropriate. However,
Background. The use of robotics in joint arthroplasty was initiated in 1992 with the introduction of the ROBODOC® Surgical Assistant device for planning and active robotic preparation of the femoral canal in THA. From 1993–1996, an FDA trial was undertaken using pin-based fiduciary markers to register the CT to the robot coordinate system. From 2000–2006, a second FDA trial was initiated using a point-to-surface matching “pinless” registration system. Combined, these two studies offer the first long-term follow-up of robot-assisted THA using an active robotic system for preparation of the femoral canal during THA. Methods. Due to the support of an open implant architecture, patients were implanted with either the Depuy AML, Howmedica Osteoloc, or Zimmer VerSys FMT. Combining patients from the two studies, 86 THA's were performed in 63 patients using the active robotic system. Of these 63 patients, 7 were confirmed to have died and 5 have been lost to follow-up, 2 declined to participate due to infirmity, 37 are still recruiting, and 12 are currently enrolled (16 hips). Data collected included: Harris Hip Scale, HSQ-12, WOMAC, UCLA Activity Score, VAS Pain Score as well as radiographic analysis. The demographics at follow-up were:. Results. There were no revisions of the femoral component for aseptic reasons. Of the 16 hips enrolled, only two have required reoperation for head and liner change. Clinical results are given below:. Radiographic analysis found that peri-acetabular osteolysis was present in 12.5% of hips, AP femoral osteolysis was found in 18.8% of hips, above and lateral femoral osteolysis was found in 6.3% of cases. Conclusions. The use of active robotics for preparation of the femoral canal in THA appears safe and effective at a long-term follow-up of 14 years. The clinical results are comparable to or better than other long term studies of
As an increasing number of young, active, large patients are becoming candidates for total hip replacements, there is an increasingly urgent need to identify arthroplasties that will be durable, highly functional and amenable to possible future successful revision. In an era when cemented femoral stems were the primary implant option, the concept of a surface replacement was attractive and, perhaps, appropriate. However,
Introduction. Short-stem hip arthroplasty is gaining popularity as a method of treating hip arthritis in biologically younger patients. The potential benefit of using a short-stem is preservation of bone in the proximal femur for a future revision. We have compared the early clinical and radiological results of a short-stem hip arthroplasty versus a conventional total hip arthroplasty (THA) using a standard length femoral prosthesis with particular focus on functional outcome. Methods. We evaluated a prospectively collected data on consecutive series of 249 patients, who underwent uncemented total hip arthroplasty at our institution. They were distributed into 2 groups: Group I, 125 patients received an uncemented short femoral stem (Mini Hip Arthroplasty (MHA), Corin, Cirencester) and Group II, 124 patients received a conventional
As an increasing number of young, active, large patients are becoming candidates for total hip replacements, there is an increasingly urgent need to identify arthroplasties that will be durable, highly functional and amenable to possible future successful revision. In an era when cemented femoral stems were the primary implant option, the concept of a surface replacement was attractive and, perhaps, appropriate. However,
25 patients in age group (25–40yrs), 15 males, 10 females were implanted with a short metaphyseal cementless stem (‘Proxima’®, Depuy) and cementless acetabular cup. The average follow up was 2.3 years (1.4–2.5 yrs). Clinical evaluation using Harris Hip Score, Radiological evaluation and Bone Mineral Density were evaluated at 2weeks, 6 months, 12 months and yearly thereafter. a new zonal method suitable for short stem was used for radiological evaluation. The mean Harris Hip score improved from 44 to 95 at final follow up. There was no evidence of any radiolucent lines or osteolysis around the stems. All the stems showed evidence of osseointegration at one year follow up. There was no decrease in bone mineral density around the stems. The Short Metaphyseal