header advert
Results 1 - 20 of 103
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 37 - 37
1 Apr 2022
McMahon S Hill R Pinto D Jackson D
Full Access

Introduction

We present the first 12 consecutive patients, undergoing elective paediatric limb reconstruction with an external fixator, for the 12-month period October 2020-October 2021. This is a single surgeon series for a newly appointed Consultant with limited previous experience. Arrangements were made for mentoring by a senior surgeon recently retired from the NHS but still active in private practice.

Materials and Methods

The average age of patients was 10.5years at the time of frame application (5—15 years). Four frames in three patients were for Blount's; two for sequelae of NF1; two for posteromedial tibial bow with shortening, two for fibula hemimelia; one congenital short femur, one for sequelae of neonatal sepsis and one for bone loss following tumour resection.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 24 - 24
1 Mar 2013
Hipps D Holmes A Sugden K Refaie R Dowen D C. Gray A
Full Access

There were 70000 people admitted to hospital with fractured hips in 2007 and the incidence is rising by 2% each year. Hip fractures represent significant morbidity and mortality to patients and cost the NHS £1.8 billion annually. In 2008 the British Orthopaedic Association Standards for Trauma (BOAST) issued a 14-point guideline to be followed for the management of hip fractures. The aim was to improve secondary prevention of osteoporosis, reduce the falls risk and further fractures. This aimed to provide better care to improve the outcomes for patients and reduce the burden of hip fractures on society. The aim of the audit was to see if the BOAST guidelines are met before and after the transition to a level 1 MTC (Major Trauma Centre) and to measure any impact the change had. Methods: Prospective data was collected for three months in 2010, 2011 and 2012. 94 case notes were reviewed and compared to the outcomes laid out in the BOAST guidelines to see if standards were met. Overall adherence to the guideline's recommendations was high throughout the 3 sample months. For each of the 3 sample months 100% adherence was seen in all of the following criteria: further imaging if x-rays unclear, appropriate analgesia, pre-op assessment, seniority of surgeon, orthogeriatrician involvement, seniority of surgeons and submission to the National Hip Fracture Database. The main common area where adherence was less than 100% was with A and E breaches (i.e. greater than 4 hours referral to the ward). Despite relocation and transition to a level 1 MTC, the management of fractured neck of femur patients compared to the BOAST guidelines remained of a high standard. Further improvements have also been made since moving to the new hospital site where shortcomings in management have been identified. Improvements from year one to three include prophylactic antibiotics and warfarin reversal; there is now a new trust protocol in place for warfarin reversal in the case of hip fractures. Elsewhere adherence to the guidelines remains high across the sample months. Confirming that despite moving to a level 1 status the trauma team continues to be performing well and managing this group appropriately. In January 2012 BOAST published a second version of the hip fracture guidelines: A and E breaches were removed from the guidelines. There have also been several new additions to the guidelines, which prompt a further re-audit in the future


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 25 - 25
1 Feb 2017
McEntire B Zhu W Pezzotti G Marin E Sugano N Bal B
Full Access

Introduction. Femoral heads made from zirconia-toughened alumina (ZTA) are the most advanced bioceramic available for total hip arthroplasty. ZTA's superior mechanical properties result from the polymorphic transformation of its zirconia (ZrO. 2. ) phase in the presence of a propagating crack. In vitro derived activation energies predict that several human lifetimes are needed to reach a state of significant transformation;. 1. but in vivo confirmation of material stability is still lacking. This investigation determined if transition metal ions might be responsible for triggering the tetragonal to monoclinic (t®m-ZrO. 2. ) phase transformation in this bioceramic. Materials and Methods. BIOLOX. ®. delta femoral heads (CeramTec GmbH, Plochingen, Germany) were acquired and characterized for their surface monoclinic content, Vm, using Raman spectroscopy. Then they were physiologically scratched with different metals (i.e., Ti, CoCr, and Fe, n=3 each) to simulate in vivo staining as a result of acetabular shell impingement due to subluxation or dislocation. They were subsequently hydrothermally aged for up to 100 h in an autoclave at 98∼132. °. C and 1 bar pressure. Raman maps, each consisting of 120 spectra, were compiled and monoclinic contents, Vm, calculated for zones adjacent to and away from the metal stains. 2. Activation energies for the t®m transformation in stained and non-stained zones were derived and compared to retrieved heads having service lives of between ∼45 days and ∼8 years. Results. The fractions of m-ZrO2 in the as-received and treated heads are presented in Table 1. In all cases, significantly greater amounts of m-ZrO. 2. were found on the metal stained areas, with the transformation amounts similar to retrieved heads. Activation energies for the t®m transformation in non-stained, CoCr-, Fe-, and Ti-stained zones were found to be 79, 60, 62, and 67 kJ/mol, respectively. Extrapolated t®m time-transformation curves at 37. °. C are shown in Figure 1 along with average m-ZrO. 2. fractions from 15 short- and medium-term retrievals. Data are compiled for values obtained on the main-wear-zones (MWZ) and non-wear-zones (NWZ) versus their elapsed time in vivo. Discussion. This experiment suggests a discrepancy in predicted (in vitro) versus observed (in vivo) phase transformation rates for metal stained ZTA femoral heads. 1. This phenomenon should be carefully considered because of its potential effect after reductions of dislocations and in the taper of these heads. While explaining the gap between in vitro predictions and in-vivo observations for phase transformation rates in ZTA components, an intrinsic incompatibility between ZTA and metal ions was also demonstrated. This phenomenon arises from a catalytic reaction at the ceramic surface by enhanced hydroxyl concentrations near the metal stains. Conclusion. Metal ions have an apparent detrimental role in destabilizing the zirconia phase at the surface of ZTA femoral heads which may impact mechanical or wear performance. Metal ions naturally present in the prosthetic joint space, metal staining of the head from hip instability, or metal ions released from modular taper corrosion may contribute to ZTA instability, even in well-functioning THA prostheses


Background. 70% of breast cancer patients develop metastatic bone deposits, predominantly spinal metasases. Adult Mesenchymal Stem Cells (MSCs) are multiprogenitor stem cells found within the bone marow which have the ability to self-renew and differentiate into multiple cell types. MSCs home specifically to tumour sites, highlighting their potential as delivery vehicles for therapeutic agents. However studies show they may also increase tumour metastatic potential. Aim. To investigate interactions between MSCs and breast cancer cells to further elucidate their role in the tumour microenvironment and hence understand factors involved in stimulating the formation of bone metastases. Methods. MSCs harvested from the iliac crest of healthy volunteers were grown for collection of conditioned medium (CM), containing all factors secreted by the cells. Breast cancer cell lines (T47D, SK-BR-3, MDA-MB-231) were then cultured in MSC CM +/− antibodies to TGFβ, VEGF, MCP-1 and CCL5 for 72hrs. Cell proliferation was assessed using an Apoglow. (r). assay and RNA harvested for analysis of changes in Epithelial Mesenchymal Transition specific gene expression : N-Cadherin, E-Cadherin, Vimentin, Twist, Snail. Results. A significant down regulation of breast cancer cell proliferation in the presence of MSC secreted factors was observed (p< 0.05). There was a dramatic increase in expression of EMT specific genes in both cell lines following exposure to MSC-secreted factors. Inclusion of antibodies to TGF, VEGF, MCP-1 and CCL5 inhibited the effect seen, suggesting these paracrine factors played a role in the elevated expression levels. Conclusion. MSCs clearly have a distinct paracrine effect on breast cancer epithelial cells, mediated at least in part through secretion of growth factors and chemokines. These factors play an important role in the metastatic cascade and may represent potential therapeutic targets to inhibit MSC-breast cancer interactions, helping to prevent the formation of bone metastases in cancer


Background. 70% of Breast Cancer patients develop metastatic bone deposits, predominantly spinal metasases. Adult Mesenchymal Stem Cells (MSCs) are multiprogenitor stem cells found within the bone marow which have the ability to self renew and differentiate into multiple cell types. MSCs home specifically to tumour sites, highlighting their potential as delivery vehicles for therapeutic agents. However studies show they may also increase tumour metastatic potential. Aims. The aim of this study was to investigate interactions between MSCs and breast cancer cells to further elucidate their role in the tumour microenvironment and hence understand factors involved in stimulating the formation of bone metastases. Methods. MSCs harvested from the iliac crest of healthy volunteers were grown for collection of conditioned medium (CM), containing all factors secreted by the cells. Breast cancer cell lines (T47D, SK-BR-3, MDA-MB-231) were then cultured in MSC CM +/− antibodies to TGFβ, VEGF, MCP-1 and CCL5 for 72hrs. Cell proliferation was assessed using an Apoglow(r) assay and RNA harvested for analysis of changes in Epithelial Mesenchymal Transition specific gene expression : N-Cadherin, E-Cadherin, Vimentin, Twist, Snail. Results. A significant down regulation of breast cancer cell proliferation in the presence of MSC secreted factors was observed (p<0.05). There was a dramatic increase in expression of EMT specific genes in both cell lines following exposure to MSC-secreted factors. Inclusion of antibodies to TGF, VEGF, MCP-1 and CCL5 inhibited the effect seen, suggesting these paracrine factors played a role in the elevated expression levels. Conclusion. MSCs clearly have a distinct paracrine effect on breast cancer epithelial cells, mediated at least in part through secretion of growth factors and chemokines. These factors play an important role in the metastatic cascade and may represent potential therapeutic targets to inhibit MSC-breast cancer interactions, helping to prevent the formation of bone metastases in cancer


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 48 - 48
1 Sep 2012
Melloh M Elfering A Röder C Hendrick P Darlow B Theis J
Full Access

Most people experience low back pain (LBP) at least once in their lifetime. A minority goes on to develop persistent LBP causing significant socioeconomic costs. Aim of this study was to identify factors that influence the progression of acute to persistent LBP at an early stage (Hilfiker et al. 2007).

Prospective inception cohort study of patients attending a health practitioner for their first episode of acute LBP or recurrent LBP after a pain free period of at least six months. Patients were assessed at baseline addressing occupational and psychological factors as well as pain, disability, quality of life and physical activity, and followed up over six months. Baseline and follow-up questionnaires were based on the recommendations of the Multinational Musculoskeletal Inception Cohort Study (MMICS) Statement (Pincus et al. 2008). Variables were combined to the three indices ‘working condition’, ‘depression and maladaptive cognitions’ and ‘pain and quality of life’.

The index ‘depression and maladaptive cognitions’ comprising of depression, somatisation, a resigned attitude towards the job, fear-avoidance, catastrophizing and negative expectations on return to work was found to be a significant baseline predictor for persistent LBP up to six months (OR 5.1; 95%CI 1.04–25.1). The diagnostic accuracy of the predictor model had a sensitivity of 0.54 and a specificity of 0.90. Positive likelihood ratio was moderate with 5.3, negative likelihood ratio 0.5. Overall predictive accuracy of the model was 81%. The area under the curve in receiver operating characteristic (ROC) analysis of the index was 0.78 (CI95% 0.65–0.92), demonstrating a satisfactory quality of discrimination.

Psychological factors in patients with acute LBP in a primary care setting correlated with a progression to persistent LBP up to six months. The benefit of including factors such as ‘depression and maladaptive cognition’ in screening tools is that these factors can be addressed in primary and secondary prevention.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 92 - 92
23 Feb 2023
Lee S Lin J Lynch J Smith P
Full Access

Dysmorphic pelves are a known risk factor for malpositioned iliosacral screws. Improved understanding of pelvic morphology will minimise the risk of screw misplacement, neurovascular injuries and failed fixation. Existing classifications for sacral anatomy are complex and impractical for clinical use. We propose a CT-based classification using variations in pelvic anatomy to predict the availability of transosseous corridors across the sacrum. The classification aims to refine surgical planning which may reduce the risk of surgical complications. The authors postulated 4 types of pelves. The “superior most point of the sacroiliac joint” (sSIJ) typically corresponds with the mid-lower half of the L5 vertebral body. Hence, “the anterior cortex of L5” (L5. a. ) was divided to reference 3 distinct pelvic groups. A 4. th. group is required to represent pelves with a lumbosacral transitional vertebra. The proposed classification:. A – sSIJ is above the midpoint of L5. a. B – sSIJ is between the midpoint and the lowest point of L5. a. C – sSIJ is below the lowest point of L5. a. D – pelves with a lumbosacral transitional vertebra. Specific measures such as the width of the S1 and S2 axial and coronal corridors and the S1 lateral mass angles were used to differentiate between pelvic types. Three-hundred pelvic CT scans were classified into their respective types. Analysis of the specific measures mentioned above illustrated the significant difference between each pelvic type. Changes in the size of S1 and S2 axial corridors formed a pattern that was unique for each pelvic type. The intra- and inter-observer ratings were 0.97 and 0.95 respectively. Distinct relationships between the sizes of S1 and S2 axial corridors informed our recommendations on trans-sacral or iliosacral fixation, number and orientation of screws for each pelvic type. This classification utilises variations in the posterior pelvic ring to offer a planning guide for the insertion of iliosacral screws


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 25 - 25
10 Feb 2023
Truong A Perez-Prieto D Byrnes J Monllau J Vertullo C
Full Access

While pre-soaking grafts in vancomycin has demonstrated to be effective in observational studies for anterior cruciate ligament reconstruction (ACLR) infection prevention, the economic benefit of the technique is uncertain. The primary aim of this study was to determine the cost-effectiveness of vancomycin pre-soaking during primary ACLR to prevent post-operative joint infections. The secondary aims of the study were to establish the breakeven cost-effectiveness threshold of the technique. A Markov model was used to determine cost effectiveness and the incremental cost effectiveness ratio of additional vancomycin pre-soaking compared to intravenous antibiotic prophylaxis alone. A repeated meta-analysis of nine cohort studies (Level III evidence) was completed to determine the odds ratio of infection with vancomycin pre-soaking compared to intravenous antibiotics alone. Estimated costs and transitional probabilities for further surgery were obtained from the literature. Breakeven threshold analysis was performed. The vancomycin soaking technique provides an expected cost saving of $600AUD per patient. There was an improvement in the quality-adjusted life years of 0.007 compared to intravenous antibiotic prophylaxis alone (4.297 versus 4.290). If the infection rate is below 0.023% with intravenous antibiotics alone or the additional intervention cost more than $1000AUD, the vancomycin wrap would no longer be cost-effective. For $30AUD, the vancomycin soaking technique provides a $600AUD cost saving by both reducing the risk of ACLR related infection and economic burden of infection. Treating septic arthritis represents a mean cost per patient of 6 times compared to that of the primary surgery. There has been no previous cost-effectiveness study of the vancomycin wrap technique. The vancomycin pre-soaking technique is a highly cost-effective method to prevent post-operative septic arthritis following primary ACLR


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 23 - 23
1 Dec 2022
Innmann MM Verhaegen J Reichel F Schaper B Merle C Grammatopoulos G
Full Access

The presence of hip osteoarthritis is associated with abnormal spinopelvic characteristics. This study aims to determine whether the pre-operative, pathological spinopelvic characteristics “normalize” at 1-year post-THA. This is a prospective, longitudinal, case-control matched cohort study. Forty-seven patients underwent pre- and post- (at one-year) THA assessments. This group was matched (age, sex, BMI) with 47 controls/volunteers with well-functioning hips. All participants underwent clinical and radiographic assessments including lateral radiographs in standing, upright-seated and deep-flexed-seated positions. Spinopelvic characteristics included change in lumbar lordosis (ΔLL), pelvic tilt (ΔPT) and hip flexion (pelvic-femoral angle, ΔPFA) when moving from the standing to each of the seated positions. Spinopelvic hypermobility was defined as ΔPT>30° between standing and upright-seated positions. Pre-THA, patients illustrated less hip flexion (ΔPFA −54.8°±17.1° vs. −68.5°± 9.5°, p<0.001), greater pelvic tilt (ΔPT 22.0°±13.5° vs. 12.7°±8.1°, p<0.001) and greater lumbar movements (ΔLL −22.7°±15.5° vs. −15.4°±10.9°, p=0.015) transitioning from standing to upright-seated. Post-THA, these differences were no longer present (ΔPFApost −65.8°±12.5°, p=0.256; ΔPTpost 14.3°±9.5°, p=0.429; ΔLLpost −15.3°±10.6°, p=0.966). The higher prevalence of pre-operative spinopelvic hypermobility in patients compared to controls (21.3% vs. 0.0%; p=0.009), was not longer present post-THA (6.4% vs. 0.0%; p=0.194). Similar results were found moving from standing to deep-seated position post-THA. Pre-operative, spinopelvic characteristics that contribute to abnormal mechanics can normalize post-THA following improvement in hip flexion. This leads to patients having the expected hip-, pelvic- and spinal flexion as per demographically-matched controls, thus potentially eliminating abnormal mechanics that contribute to the development/exacerbation of hip-spine syndrome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 23 - 23
24 Nov 2023
Xie C Ren Y Weeks J Lekkala S Rainbolt J Xue T Shu Y Lee K de Mesy Bentley KL Yeh S Schwarz E
Full Access

Title. Longitudinal Intravital Imaging to Quantify the “Race for the Surface” Between Host Immune Cell and Bacteria for Orthopaedic Implants with S. aureus Colonization in a Murine Model. Aim. To assess S. aureus vs. host cell colonization of contaminated implants vis intravital multiphoton laser scanning microscopy (IV-MLSM) in a murine model. Method. All animal experiments were approved by IACUC. A flat stainless steel or titanium L-shaped pin was contaminated with 10. 5. CFU of a red fluorescent protein (RFP) expressing strain of USA300LAC, and surgically implanted through the femur of global GFP-transgenic mice. IV-MLSM was performed at 2, 4, and 6 hours post-op. Parallel cross-sectional CFU studies were performed to quantify the bacteria load on the implant at 2,4,6,12,18 and 24 hours. Results. 1) We developed a high-fidelity reproducible IV-MLSM system to quantify S. aureus and host cell colonization of a bone implant in the mouse femur. Proper placement of all implants were confirmed with in vivo X-rays, and ex vivo photos. We empirically derive the ROI during each imaging session by aggregating the imaged volume which ranges from (636.4um × 636.4um × 151um) = 0.625 +/- 0.014 mm. 3. of bone marrow in a global GFP-transgenic mouse. 2) IV-MLSM imaging acquisition of the “race for the surface”.In vitro MPLSM images of implants partially coated with USA300LAC (RFP-MRSA) were verified by SEM image. Results from IV-MLSM of RFP-MRSA and GFP. +. host cell colonization of the contaminated implants illustrated the mutually exclusive surface coating at 3hrs, which to our knowledge is the first demonstration of “the race for the surface” between bacteria and host cells via intravital microscopy. 3) Quantifying the “race for the surface” with CFU verification of S. aureus on the implant. 3D volumetric rendering of the GFP. +. voxels and RFP+ voxels within the ROI were generated in Imaris. The voxel numbers suggeste that the fight for the surface concludes ∼3hrs post-infection, and then transitions to an aggressive MRSA proliferation phase. The results of WT control demonstrate a significant increase in CFU by 12hrs post-op for both stainless steel (P<0.01) and titanium (P<0.01). Conclusions. We developed IV-MLSM to quantify the “Race for the Surface” between host cells and contaminating S. aureus in a murine femur implant model. This race is remarkably fast, as the implant surface is completely covered with 3hrs, peak bacterial growth on the implant occurs between 2 and 12 hours and is complete by 12hrs


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 29 - 29
1 Apr 2022
Jido JT Rodham P Giannoudis V Andronic A Harwood P
Full Access

Introduction. Routine radiographs in the follow-up of circular frames is commonplace, however the effect on clinical decision making is unclear. Previous work locally has suggested that >95% of radiographs, particularly at early time points, do not affect clinical management. This study was conducted to assess the impact of a transition to early remote follow-up on circular frame patients with limited radiographic assessment. Materials and Methods. Patients were identified from a prospective limb reconstruction database. Data were collected including the number of clinic appointments, type of clinic appointment, number of radiographs performed, and impact this had on clinical management. This was compared to our previous cohort of 85 patients undergoing standard follow-up. Results. Fourteen patients were eligible for inclusion (mean age 45, range 26–75). Circular frames were indicated for trauma (12), or limb reconstruction (2). Following introduction of remote follow-up, the mean number of face-to-face appointments reduced from 6.1 to 1.7 to the point of frame removal. Conversion from telephone follow-up to face-to-face follow-up was required in just one case where hardware failure occurred. The number of radiographs during treatment was reduced from a mean of 22 to 11 (range 4–20). Conclusions. Remote follow-up of circular frame patients was associated with significantly fewer radiographs and face-to-face appointments, without significantly increasing complications. We believe this is a safe and effective method of follow-up, optimising resource use in line with the NHS long term plan. Data collection is ongoing, and a larger cohort would be available for presentation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 118 - 118
1 Feb 2017
Fitzpatrick C Clary C Rullkoetter P
Full Access

Introduction. Patellar crepitus and clunk are tendofemoral-related complications predominantly associated with posterior-stabilizing (PS) total knee arthroplasty (TKA) designs [1]. Contact between the quadriceps tendon and the femoral component can cause irritation, pain, and catching of soft-tissue within the intercondylar notch (ICN). While the incidence of tendofemoral-related pathologies has been documented for some primary TKA designs, literature describing revision TKA is sparse. Revision components require a larger boss resection to accommodate a constrained post-cam and stem/sleeve attachments, which elevates the entrance to the ICN, potentially increasing the risk of crepitus. The objective of this study was to evaluate tendofemoral contact in primary and revision TKA designs, including designs susceptible to crepitus, and newer designs which aim to address design features associated with crepitus. Methods. Six PS TKA designs were evaluated during deep knee bend using a computational model of the Kansas knee simulator (Figure 1). Prior work has demonstrated that tendofemoral contact predictions from this model can differentiate between TKA patients with patellar crepitus and matched controls [2]. Incidence of crepitus of up to 14% has been reported in Insall-Burstein® II and PFC® Sigma® designs [3]. These designs, in addition to PFC® Sigma® TC3 (revision component), were included in the analyses. Primary and revision components of newer generation designs (NexGen®, Attune® and Attune® Revision) were also included. Designs were evaluated in a patient model with normal Insall-Salvati ratio and a modified model with patellar tendon length reduced by two standard deviations (13mm) to assess worst-case patient anatomy. Results. During simulations with normal patellar tendon length, only PFC® Sigma® and PFC® Sigma® TC3 showed tendofemoral contact within the trochlea, and no design showed contact at the transition to the ICN (Figure 2). In simulations with patella baja, Insall-Burstein® II, PFC® Sigma®, and PFC® Sigma® TC3, demonstrated tendofemoral contact across the trochlea at the transition into the notch. In contrast, NexGen®, Attune® and Attune® Revision showed tendon contact for approximately half the width of the transition to the notch (Figure 3). PFC® Sigma® and Attune® demonstrated very similar tendofemoral contact to their equivalent revision components, although the shorter trochlear groove of Attune® Revision marginally increased contact at the transition. Discussion. Insall-Burstein® II, PFC® Sigma®, and PFC® Sigma® TC3 designs showed full contact with the quadriceps tendon at the anterior border of the ICN when combined with a short patellar tendon. NexGen®, Attune® and Attune® Revision had a more gradual transition between the trochlea and the notch, which resulted in less exposure to tendon contact. Even with the shorter trochlear groove required for revision components, Attune® Revision showed minimal difference in tendofemoral contact when compared with Attune®. There appears to be distinct benefit in a femoral design which reduces tendofemoral contact at the transition to the ICN; this may be of particular importance for patients with patella baja


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 35 - 35
1 Dec 2022
Verhaegen J Innmann MM Batista NA Merle C Grammatopoulos G
Full Access

Adverse spinopelvic characteristics (ASC) have been associated with increased dislocation risk following primary total hip arthroplasty (THA). A stiff lumbar spine, a large posterior standing tilt when standing and severe sagittal spinal deformity have been identified as key risk factors for instability. It has been reported that the rate of dislocation in patients with such ASC may be increased and some authors have recommended the use of dual mobility bearings or robotics to reduce instability to within acceptable rates (<2%). The aims of the prospective study were to 1: Describe the true incidence of ASC in patients presenting for a THA 2. Assess whether such characteristics are associated with greater symptoms pre-THA due to the concomitant dual pathology of hip and spine and 3. Describe the early term dislocation rate with the use of ≤36mm bearings. This is an IRB-approved, two-center, multi-surgeon, prospective, consecutive, cohort study of 220 patients undergoing THA through anterolateral- (n=103; 46.8%), direct anterior- (n=104; 27.3%) or posterior- approaches (n=13; 5.9%). The mean age was 63.8±12.0 years (range: 27.7-89.0 years) and the mean BMI 28.0±5.0 kg/m. 2. (range: 19.4-44.4 kg/m. 2. ). There were 44 males (47.8%) and 48 females (52.2%). The mean follow-up was 1.6±0.5 years. Overall, 54% of femoral heads was 32 mm, and 46% was 36mm. All participants underwent lateral spinopelvic radiographs in the standing and deep-flexed seated positions were taken to determine lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), pelvic-femoral angle (PFA) and pelvic incidence (PI) in both positions. Spinal stiffness was defined as lumbar flexion <20° when transitioning between the standing and deep-seated position; adverse standing PT was defined as >19° and adverse sagittal lumbar balance was defined as mismatch between standing PI and LL >10°. Pre-operative patient reported outcomes was measured using the Oxford Hip Score (OHS) and EuroQol Five-Dimension questionnaire (EQ-5D). Dislocation rates were prospectively recorded. Non-parametric tests were used, significance was set at p<0.05. The prevalence of PI-LL mismatch was 22.1% (43/195) and 30.4% had increased standing PT (59/194). The prevalence of lumbar stiffness was 3.5% (5/142) and these patients had all three adverse spinopelvic characteristics (5/142; 3.5%). There was no significant difference in the pre-operative OHS between patients with (20.7±7.6) and patients without adverse spinopelvic characteristics (21.6±8.7; p=0.721), nor was there for pre-operative EQ5D (0.651±0.081 vs. 0.563±0.190; p=0.295). Two patients sustained a dislocation (0.9%): One in the lateral (no ASC) and one in the posterior approaches, who also exhibited ASC pre-operatively. Sagittal lumbar imbalance, increased standing spinal tilt and spinal stiffness are not uncommon among patients undergoing THA. The presence of such characteristics is not associated with inferior pre-operative PROMs. However, when all characteristics are present, the risk of instability is increased. Patients with ASC treated with posterior approach THA may benefit from the use of advanced technology due to a high risk of dislocation. The use of such technology with the anterior or lateral approach to improve instability is to date unjustified as the rate of instability is low even amongst patients with ASCs


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 146 - 146
1 Feb 2020
King C Chakour K Kim Y Luu H Martell J
Full Access

Introduction. Background: Trochanteric bursitis is a common and poorly understood complication following total hip arthroplasty (THA). The purpose of this study was to evaluate the incidence of symptomatic trochanteric bursitis and the change in hip offset among THA patients before and after the introduction of robotic assistance. Methods. Retrospective chart review of THAs performed by a single over a 3-year period between 1/5/2013 and 6/28/2016. Between 1/5/2013 and 11/11/2014 101 consecutive patients were identified that underwent manual posterior-lateral THA that utilized traditional cup positioning method based on AP Pelvis radiograph. The subsequent six-month period during a complete transition to robotic arm assistance for posterior-lateral THA was excluded to eliminate any learning curve or selection bias. Between 6/2015 and 6/2016 109 consecutive patients that underwent robotic arm-assisted. Medical records were reviewed for symptomatic trochanteric bursitis within two years of surgery. Hip offset was measured on preoperative and postoperative AP pelvis radiographs and postoperative joint reactive forces were calculated using Martell's Hip Analysis Suite. Results. The rate of symptomatic trochanteric bursitis was 21% in the manual THA population and 10.4% in the population of THAs performed with robotic assistance (P=0.02). The post-operative change in hip offset was significantly higher in patients undergoing traditional THA than patients undergoing robotic arm-assisted THA (5.95 mm vs 4.40 mm; p = 0.0071). Discussion/Conclusion. Transition to robotic arm-assisted THA was associated with decreased incidence of symptomatic trochanteric bursitis and a decreased post-operative change in hip offset


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 12 - 12
1 Feb 2020
King C Jordan M Edgington J Wlodarski C Tauchen A Puri L
Full Access

Introduction. This study sought to evaluate the patient experience and short-term clinical outcomes associated with the hospital stay of patients who underwent robotic arm-assisted total knee arthroplasty (TKA). These results were compared to a cohort of patients who underwent TKA without robotic assistance performed by the same surgeon. Methods. A cohort of consecutive patients undergoing primary TKA for the diagnosis of osteoarthritis by a single fellowship trained orthopaedic surgeon over a 39-month period was identified. Patients who underwent TKA during the year this surgeon transitioned his entire knee arthroplasty practice to robotic assistance were excluded to eliminate selection bias and control for the learning curve. A final population of 538 TKAs was identified. Of these, 314 underwent TKA without robotic assistance and 224 underwent robotic arm-assisted TKA. All patients received the same prosthesis and post-operative pain protocol. Patient demographic characteristics and short-term clinical data were analyzed. Results. Robotic arm-assisted TKA was associated with shorter length of stay (2.3 versus 2.6 days, p< 0.001), a 50% reduction in morphine milligram equivalent utilization (from 213 to 105, p< 0.001), decreased visual analog scale pain score on post-op day 1 and 2 (p< 0.001), and a mean increase in procedure time of 8.2 minutes (p=0.08). There were no post-operative infections in either cohort. Additionally, there were no significant differences in rates of manipulation under anesthesia, emergency department visits, readmissions, or return to the operating room. Conclusions. This analysis corroborates existing literature suggesting that robotic arm-assisted TKA can be correlated with improved short-term clinical outcomes. This study reports on a single surgeon's experience with regard to analgesic requirements, length of stay, pain scores, and procedure time following a complete transition to robotic arm-assisted TKA. These results underscore the importance of continued evaluation of clinical outcomes as robotic arthroplasty technology continues to grow. For any figures or tables, please contact authors directly


Bone & Joint Open
Vol. 1, Issue 8 | Pages 474 - 480
10 Aug 2020
Price A Shearman AD Hamilton TW Alvand A Kendrick B

Introduction. The aim of this study is to report the 30 day COVID-19 related morbidity and mortality of patients assessed as SARS-CoV-2 negative who underwent emergency or urgent orthopaedic surgery in the NHS during the peak of the COVID-19 pandemic. Method. A retrospective, single centre, observational cohort study of all patients undergoing surgery between 17 March 2020 and 3May 2020 was performed. Outcomes were stratified by British Orthopaedic Association COVID-19 Patient Risk Assessment Tool. Patients who were SARS-CoV-2 positive at the time of surgery were excluded. Results. Overall, 96 patients assessed as negative for SARS-CoV-2 at the time of surgery underwent 100 emergency or urgent orthopaedic procedures during the study period. Within 30 days of surgery 9.4% of patients (n = 9) were found to be SARS-CoV-2 positive by nasopharyngeal swab. The overall 30 day mortality rate across the whole cohort of patients during this period was 3% (n = 3). Of those testing positive for SARS-CoV-2 66% (n = 6) developed significant COVID-19 related complications and there was a 33% 30-day mortality rate (n = 3). Overall, the 30-day mortality in patients classified as BOA low or medium risk (n = 69) was 0%, whereas in those classified as high or very high risk (n = 27) it was 11.1%. Conclusion. Orthopaedic surgery in SARS-CoV-2 negative patients who transition to positive within 30 days of surgery carries a significant risk of morbidity and mortality. In lower risk groups, the overall risk of becoming SARS-CoV-2 positive, and subsequently developing a significant postoperative related complication, was low even during the peak of the pandemic. In addition to ensuring patients are SARS-CoV-2 negative at the time of surgery it is important that the risk of acquiring SARS-CoV-2 is minimized through their recovery. Cite this article: Bone Joint Open 2020;1-8:474–480


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 85 - 85
1 Feb 2020
Dennis D Pierrepont J Madurawe C Lee G Shimmin A
Full Access

Introduction. It is well accepted that larger heads provide more stability in total hip arthroplasty. This is due to an increase in jump height providing increased resistance to subluxation. However, other implant parameters also contribute to the bearing's stability. Specifically, the liner's rim design and the centre of rotation relative to the liner's face. Both these features contribute to define the Cup Articular Arc Angle (CAAA). The CAAA describes the degree of dysplasia of the acetabular liner, and plays an important role in defining the jump height. The aim of this study was to determine the difference in jump height between bearing materials with a commonly used acetabular implant system. Methods. From 3D models of the Trinity acetabular implant system (Corin, UK), the CAAA was measured in CAD software (SolidWorks, Dassault Systems, France) for the ceramic, poly and modular dual mobility (DM) liners, for cup sizes 46mm to 64mm. The most commonly used bearing size was used in the analysis of each cup size. For the ceramic and poly liners, a 36mm bearing was used for cups 50mm and above. For the 46mm and 48mm cups, a 32mm bearing was used. The DM liners were modelled with the largest head size possible. Using a published equation, the jump height was calculated for each of the three bearing materials and each cup size. Cup inclination and anteversion were kept constant. Results. CAAA varied substantially between cup sizes and bearing materials. The mean CAAA for the ceramic, poly and DM bearings were 166°, 175° and 186°, respectively. Consequently, over the entire size range, the ceramic liners had the lowest mean jump height of 12.9mm. In comparison to the ceramic liner, there was a mean 10% increase in jump height when transitioning to a poly (14.2mm), and a further 30% increase when transitioning from a poly to the dual mobility bearing (18.5mm) [Fig.1]. However, the difference in jump heights between bearings was variable, and dependent on cup size. Discussion. It is well understood that increasing head size increases stability in THA. However, other implant design parameters contribute to stability. With this particular implant system, the poly bearing had a greater jump height than the ceramic for cup sizes 50mm and above. The DM bearing improved jump height over the ceramic and poly by a mean of 41% and 30%, respectively. In conclusion, different liners have different design features that affect jump height. Consequently, not all bearings of identical head size are the same. We encourage a dialogue with your implant provider to understand the differences in CAAA between cup sizes and bearing materials. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 46 - 46
1 Apr 2019
Kim YW Girinon F Lazennec JY Skalli W
Full Access

Introduction. Stand to sit pelvis kinematics is commonly considered as a rotation around the bicoxofemoral axis. However, abnormal kinematics could occur for patients with musculoskeletal disorders affecting the hip-spine complex. The aim of this study is to perform a quantitative analysis of the stand to sit pelvis kinematics using 3D reconstruction from bi-planar x-rays. Materials and Methods. Thirty healthy volunteers as a control group (C), 30 patients with hip pathology (Hip) and 30 patients with spine pathology (Spine) were evaluated. All subjects underwent standing and sitting full-body bi-planar x-rays. 3D reconstruction was performed in each configuration and then translated such as the middle of the line joining the center of each acetabulum corresponds to the origin. Rigid registration quantified the finite helical axis (FHA) describing the transition between standing and sitting with two specific parameters. The orientation angle (OA) is the signed 3D angle between FHA and bicoxofemoral axis and the rotation angle (RA) represents the signed angle around FHA. Pelvic incidence, sacral slope and pelvic tilt were also measured. After checking normality of distribution, parameters were compared statistically between the 3 groups (p<0.05). Results. The mean value of the orientation angle in control group was −1.8° (SD 10.8°, range −26° to 25°). The mean value of the OA was 0.3° (SD 12.3°, range to −31° to 37°) in Hip group and −4.7° (SD 21.5°, range −86° to 38°) in Spine group. There was no significant difference in mean OA among groups. However, the more subnormal and abnormal patients were in Spine group compared to C and Hip groups. The mean value of the rotation angle in C group was 18.1° (SD 9.1°, range 5° to 43°). There was significant difference in RA between Hip and Spine groups (21.1° (SD 8.0°) and 16.0° (SD 10.7°), respectively) (p=0.04). Conclusion. This study highlights new informations obtained by the quantitative analysis of pelvis rotation between standing and sitting in healthy, hip pathology patients and spine pathology patients using 3D reconstruction from bi-planar radiographs. Hip and spine pathologies affect stand to sit pelvic kinematics. Surgeons should be aware of potential abnormal stand to sit transition in such clinical situations. This improved assessment of the pelvic rotational adaptation could lead to a more personalized approach for the planning of hip prostheses


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 63 - 63
1 Mar 2012
Kanwar R George K Johnson K Prem H
Full Access

To assess healing pattern of Achilles tendons across the gap created by a percutaneous tenotomy and maintained by cast in club feet. Twenty-one tenotomies in 16 patients (Age range 12 weeks-36 months) were monitored with dynamic and static ultrasonographic studies. Ultrasounds were performed before and immediately after tenotomy and at approximately 3, 6 and 12 weeks post tenotomy. Cast removal was done at three weeks. Two patients above age of two were casted for 6 weeks. The healing pattern went through different phases although they were not distinctively exclusive from each other and did show considerable overlap. First phase showed formation of a bulbous mass with some continuity of scar tissue across tendon gap. The transition zone between new fibre and the original tend quite distinct. However dynamic ultrasound showed the Achilles tendon moved as a single unit. Second phase showed fibres resembling normal tendon crossing the gap and reduction of bulbous mass. The transition zone was still discernible. Final stage demonstrated more homogenous fibres of Achilles tendon with an indistinct transition zone. Two older children showed a distinctly longer process of healing. One child showed an irregular mass of fluid and soft tissue structures in the gap at six weeks. The other child demonstrated a relative reduction in the proportion of tendon fibres across the gap. At 12 weeks there was evidence of continuation of tendon fibres, but transition zone partly visible. Conclusion. Young Child (<1 Year): when cast immobilisation is discontinued, the tendon is in mid phase of healing. There may be a positive effect on continued improvement in dorsiflexion while using boots and bars. Older Child: safe to consider percutaneous tenotomy in children up to 3 years of ages provided the period of immobilisation is extended


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 47 - 47
1 Aug 2020
Niedermair T Straub R Grässel S
Full Access

Previously, we reported impaired biomechanical bone properties and inferior bone matrix quality in tachykinin1 (Tac1)-deficient mice lacking the sensory neuropeptide substance P (SP). Additionally, fracture callus development is affected by the absence of SP indicating a critical effect of sensory nerve fibers on bone health and regeneration. For α-calcitonin gene-related peptide (α-CGRP)-deficient mice, a profound distortion of bone microarchitecture has also been described. We hypothesize that SP and α-CGRP modulate inflammatory as well as pain-related processes and positively affect bone regeneration during impaired fracture healing under osteoporotic conditions. Therefore, this study investigates the effects of SP and α-CGRP on fracture healing and fracture-related pain processes under conditions of experimental osteoporosis using SP- and α-CGRP-deficient mice and WT controls. We ovariectomized female WT, Tac1−/− and α-CGRP−/− mice (age 10 weeks, all strains on C57Bl/6J background) and set intramedullary fixed femoral fractures in the left femora 28 days later. We analyzed pain threshold (Dynamic Plantar Aesthesiometer Test) and locomotion (recorded at day and night, each for 1 hour, EthoVision®XT, Noldus) at 5, 9, 13, 16 and 21 days after fracture. At each time point, fractured femora were prepared for histochemical analysis of callus tissue composition (alcian blue/sirius red staining). Pain threshold is significantly higher in Tac1−/− mice 13 days after fracture and tends to be higher after 21 days compared to WT controls. In contrast, touch sensibility was similar in α-CGRP−/− mice and WT controls but compared to Tac1−/− mice pain threshold was significantly lower in α-CGRP−/− mice 13 and 16 days and tends to be lower 21 days after fracture. Locomotion of Tac1−/− mice during daylight was by trend higher 9 days after fracture and significantly higher 16 days after fracture whereas nightly locomotion is reduced compared to WT mice. Analysis of locomotion during daylight or night revealed no differences between α-CGRP−/− and WT mice. During early fracture healing phase, 5 and 9 days after fracture, transition of mesenchymal to cartilaginous callus tissue tends to be faster in Tac1−/− mice compared to WT controls whereas no difference was observed during late stage of fracture healing, 13, 16 and 21 days after fracture. In contrast, callus tissue maturation seems to be similar in α-CGRP−/− and WT mice. Our data indicate different effects of SP and α-CGRP on fracture healing under conditions of experimental osteoporosis as a model for impaired bone tissue. Lack of α-CGRP seems to have no effects, but loss of SP affects locomotion throughout osteoporotic fracture healing and fracture-related pain processes during late phases of osteoporotic fracture healing. This indicates a modified role of SP during fracture healing under impaired versus healthy conditions, where SP changed early fracture-related pain processes and had no influence on callus tissue composition