header advert
Results 1 - 20 of 706
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 320 - 320
1 Mar 2013
Sawada N Saito S Yabuno K Kanazawa M
Full Access

Objectives. There are few reports on total hip arthroplasty (THA) for hip osteoarthritis associated with so-called Perthes-like change including high great trochanter, short neck hip or flattened femoral head (hereinafter called “Perthes-like change”) as the operative procedures are difficult. We studied THA for “Perthes-like change” carried out in our department. Methods. We covered 14 cases (15 hips), which underwent THA for “Perthes-like change” (hereinafter called “Perthes-like change group,” operated from 2008 to September 2011. The average age at the operation was 62 (53 to 83 years old), 7 males and 7 females, and the average follow-up period was 21.8 months (6 to 48 months). For these cases we studied the clinical items and further made a comparative review of the 258 hips as a control group (Group C), which underwent THA during the same period for osteoarthritis (OA) originating in DDH (developmental dysplasia of the hip) (Crowe type 1 and 2), excluding the “Perthes-like change group.” The items reviewed include the age at the operation, operation time and intraoperative blood loss. Results. The average JOA score of the “Perthes-like change group” at the time of the study was 89 and favorable. The average operation time of the “Perthes-like change group” was 113 minutes (69 to 202 minutes) and its average intraoperative blood loss was 1066 g (490 to 3314 g). The operation time of the “Perthes-like change group” was significantly longer compared to that of the Group C (p=0.004), and its intraoperative blood loss was also significantly larger than that of the Group C (p=0.018). We carried out the muscle release operation for 8 hips (53.3%) of the “Perthes-like change group” and we combined the retachment of the great trochanter for the 1 case of them. There was no dislocation, infection, neuroparalysis and pulmonary embolism. Consideration. The “Perthes-like change group” had a longer operation time and a larger intraoperative blood loss than those of the Group C. Also there were quite a few cases that needed muscle release operation. Therefore, care should be taken in THA for hip osteoarthritis associated with “Perthes-like change” although the clinical results were favorable


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 12 - 12
1 Aug 2013
Eschweiler J Asseln M Damm P Hares GA Bergmann G Tingart M Radermacher K
Full Access

Musculoskeletal loading plays an important role in the primary stability of THA. There are about 210,000 primary THA interventions p.a. in Germany. Consideration of biomechanical aspects during computer-assisted orthopaedic surgery is recommendable in order to obtain satisfactory long-term results. For this purpose simulation of the pre- and post-operative magnitude of the resultant hip joint force R and its orientation is of interest. By means of simple 2D-models (Pauwels, Debrunner, Blumentritt) or more complex 3D-models (Iglič), the magnitude and orientation of R can be computed patient-individually depending on their geometrical and anthropometrical parameters. In the context of developing a planning module for computer-assisted THA, the objective of this study was to evaluate the mathematical models. Therefore, mathematical model computations were directly compared to in-vivo measurements obtained from instrumented hip implants.

With patient-specific parameters the magnitude and orientation of R were model-based computed for three patients (EBL, HSR, KWR) of the OrthoLoad-database. Their patient-specific parameters were acquired from the original patient X-rays. Subsequently, the computational results were compared with the corresponding in-vivo telemetric measurements published in the OrthoLoad-database. To obtain the maximum hip joint load, the static single-leg-stance was considered. A reference value for each patient for the maximum hip load under static conditions was calculated from OrthoLoad-data and related to the respective body weights (BW).

On average there are large deviations of the results for the magnitude (Ø=147%) and orientation (Ø=14.35° too low) of R obtained by using Blumentritt's model from the in-vivo results/measurements. The differences might be partly explained by the supplemental load of 20% BW within Blumentritt's model which is added to the input parameter BW in order to consider dynamic gait influences. Such a dynamic supplemental load is not applied within the other static single-leg-stance models. Blumentritt's model assumptions have to be carefully reviewed due to the deviations from the in-vivo measurement data.

Iglič's 3D-model calculates the magnitude (Ø17%) and the orientation (Ø49%) of R slightly too low. For the magnitude one explanation could be that his model considers nine individual 3D-sets of muscle origins and insertion points taken from literature. This is different from other mathematical models. The patient-individual muscle origin and insertion points should be used.

Pauwels and Debrunner's models showed the best results. They are in the same range compared to in-vivo data. Pauwels's model calculates the magnitude (Ø5%) and the orientation (Ø28%) of R slightly higher. Debrunner's model calculates the magnitude (Ø1%) and the orientation (Ø14%) of R slightly lower.

In conclusion, for the orientation of R, all the computational results showed variations which tend to depend on the used model.

There are limitations coming along with our study: as our previous studies showed, an unambiguous identification of most landmarks in an X-ray (2D) image is hardly possible. Among the study limitations there is the fact that the OrthoLoad-database currently offers only three datasets for direct comparison of static single leg stance with in-vivo measurement data of the same patient. Our ongoing work is focusing on further validation of the different mathematical models.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 541 - 541
1 Dec 2013
Higuera C Styron J Strnad G Barsoum W Iannotti J
Full Access

Introduction:

Patient medical comorbidities are well-established risk modifiers of THA patient outcomes. Patient's mental state preoperatively may influence postoperative functional outcomes though just like any medical comorbidity. This study sought to determine if patient confidence in attaining post-operative functional goals was associated with objective and subjective outcomes following THA.

Methods:

Patients undergoing primary or revision THA at a single institution between 2008 and 2010 were administered a questionnaire consisting of demographics, body mass index, Hip Dysfunction Osteoarthritis and Outcomes Score (HOOS), SF-12 scores, the level of functionality they hoped to gain postoperatively and their confidence in attaining that goal (0–10 scale) preoperatively and postoperatively at last follow-up (minimum 12 months). Measured outcomes included length of stay, 30-day readmission, HOOS, and SF-12 physical component scores. Correlation of patient confidence in attaining treatment goals and the outcomes collected was established using multiple linear and logistic regression models that were adjusted for all variables, including baseline mental and functional scores.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 63 - 63
1 Feb 2017
Chapman R Van Citters D Dalury D
Full Access

Introduction

Subluxation and dislocation are frequently cited reasons for THA revision. For patients who cannot accommodate a larger femoral head, an offset liner may enhance stability. However, this change in biomechanics may impact the mechanical performance of the bearing surface. To our knowledge, no studies have compared wear rates of offset and neutral liners. Herein we radiographically compare the in-vivo wear performance of 0mm and 4mm offset acetabular liners.

Methods

Two cohorts of 40 individuals (0mm, 4mm offset highly crosslinked acetabular liners, respectively) were selected from a single surgeon's consecutive caseload. All patients received the same THA system via the posterior approach. AP radiographs were taken at 6-week (‘pre’) and 5-year (‘post’) postoperative appointments. Patients with poor radiograph quality were excluded (n0mm=5, n4mm=4). Linear and volumetric wear were quantified according to Patent US5610966A. Briefly, images were processed in computer aided design (CAD) software. Differences in vector length between the center of the femoral head and the acetabular cup (pre- and post-vector, Figure 1) allow for calculation of linear wear and wear rate. The angle (β) between the linear wear vector and the cup inclination line was quantified (Figure 1). Patients with negative β were excluded from volumetric analyses (n0mm=11, n4mm=7). Volumetric wear was accordingly calculated accounting for wear vector direction. The results from three randomly selected patients were compared to results achieved using the “Hip Analysis Suite” software package (UChicagoTech).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 87 - 87
10 Feb 2023
Nizam I Alva A Gogos S
Full Access

The purpose of this study was to report all complications during the first consecutive 865 cases of bikini incision direct anterior approach (DAA) total hip arthroplasty (THA) performed by a single surgeon. The secondary aims of the study are to report our clinical outcomes and implant survivorship. We discuss our surgical technique to minimize complication rates during the procedure. We undertook a retrospective analysis of our complications, clinical outcomes and implant survivorship of 865 DAA THA's over a period of 6 years (mean = 5.1yrs from 2.9 to 9.4 years). The complication rates identified in this study were low. Medium term survival at minimum 2-year survival and revision as the end point, was 99.53% and 99.84% for the stem and acetabular components respectively. Womac score improved from 49 (range 40-58) preoperatively to 3.5(range 0-8.8) and similarly, HHS scores improved from 53(range 40-56) to 92.5(range 63-100) at final follow-up (mean = 5.1 yrs) when compared to preoperative scores. These results suggest that bikini incision DAA technique can be safely utilised to perform THA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 5 - 5
23 Jul 2024
Mohammed F Jones S Mansoor Z Mehta S Rathore S Azam A
Full Access

Paget's disease of bone (PDB) is characterised by increased bone resorption and development of an erratic bone structure that is highly fragile and susceptible to fracture. In addition, altered joint biomechanics lead to arthritis, more often in the hip and pelvis, resulting in disability and a Total hip Arthroplasty (THA) may be required. THA in PDB is associated with more complications compared to normal population. There is no consensus on the type of arthroplasty that performs better in people with PDB. To our knowledge, there is no meta-analysis in literature on this rare problem. We undertook a systematic review and meta-analysis to compare the effectiveness of cemented versus cementless THA in patients with PDB. PRISMA guidelines were followed. Search strings were generated based on Boolean operators for identification of the reference articles. 31 studies were included overall. Revision rate was lower in the cementless group compared to the cemented group (chi square=4.36, p=0.04), aseptic loosening was lesser in the cementless group compared to the cemented group (chi square=4.13, p=0.04). The type of the arthroplasty did not affect the infection rate (chi square=2.51, p=0.11), pre and post op Harris Hip Score showed statistically significant difference, but there was no difference between types of arthroplasty. We conclude that THA with uncemented components is better and provided lower revision and aseptic loosening when compared to cemented groups in patients with PDB


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 23 - 23
1 Nov 2022
Jha A Jayaram J Carter J Siney P James J Hemmady M
Full Access

Abstract. Cemented total hip arthroplasty (THA) in the younger patient has historically been associated with higher wear and revision rates. We carried out a retrospective study of a prospectively collected database of patients at Wrightington hospital undergoing cemented THA under 55 years of age to determine acetabular wear and revision rates. Between August 2005 and December 2021 a cohort of 110 patients, 56 males and 54 females, underwent Cemented Total Hip Replacement through a posterior approach. Mean age at operation was 50yrs (35–55). The mean follow up was 6 years 9 months (0–16 years). 3 patients were lost to follow-up. Of the remaining 107 patients, Conventional and cross lined polyethylene were used in 54 and 53 patients respectively. Ceramic heads were used in 102 patients. 22.225mm and 28mm heads were used in 60 and 47 patients respectively. Clinical outcomes were assessed by Merle d'Aubigne and Postel scores which showed significant functional improvement. Linear wear was measured on plain radiographs using TRAUMA CAD and cup loosening was assessed by classification of Hodgkinson et al. No cases were revised during the observed follow up period. The mean wear rate in conventional and crosslinked polyethylene cups were 2.31mm (0.1–4.6) and 1.02mm (0.1–2.6) respectively. Cemented THA with both conventional and crosslinked polyethylene provides excellent survival rates in adults under the age of 55 years and crosslinked polyethylene may further improve these results due to improved wear rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 5 - 5
24 Nov 2023
Szymski D Walter N Krull P Melsheimer O Grimberg A Alt V Steinbrück A Rupp M
Full Access

Aim. The aim of this investigation was to compare risk of infection in both cemented and cementless hemiarthroplasty (HA) as well as total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD) In HA and THA following femoral neck fracture fixation method was divided into cemented and cementless protheses and paired according to age, sex, body mass index (BMI), and the Elixhauser score using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, with 9,110 (66.9 %) HAs and 4502 (33.1 %) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared to cementless fixated prosthesis (p=0.013). In patients with THA no statistical difference between cemented and cementless prothesis was registered, however after one year 2.4 % of infections were detected in cementless and 2.1 % in cemented THA. In the subpopulation of HA after one year 1.9 % of infections were registered in cemented and 2.8 % in cementless HA. BMI (p=0.001) and Elixhauser-Comorbidity-Score (p<0.003) were identified as risk factors of PJI, while in THA also cemented prosthesis demonstrated within the first 30 days an increased risk (HR=2.728; p=0.010). Conclusion. The rate of infection after intracapsular femoral neck fracture was significantly reduced in patients treated by antibiotic-loaded cemented hemiarthroplasty. In particular for patients with multiple risk factors for the development of a PJI the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 10 - 10
23 Feb 2023
Hardwick-Morris M Twiggs J Miles B Jones E Bruce WJM Walter WL
Full Access

Dislocation is one of the most common complications in total hip arthroplasty (THA) and is primarily driven by bony or prosthetic impingement. The aim of this study was two-fold. First, to develop a simulation that incorporates the functional position of the femur and pelvis and instantaneously determines range of motion (ROM) limits. Second, to assess the number of patients for whom their functional bony alignment escalates impingement risk. 468 patients underwent a preoperative THA planning protocol that included functional x-rays and a lower limb CT scan. The CT scan was segmented and landmarked, and the x-rays were measured for pelvic tilt, femoral rotation, and preoperative leg length discrepancy (LLD). All patients received 3D templating with the same implant combination (Depuy; Corail/Pinnacle). Implants were positioned according to standardised criteria. Each patient was simulated in a novel ROM simulation that instantaneously calculates bony and prosthetic impingement limits in functional movements. Simulated motions included flexion and standing-external rotation (ER). Each patient's ROM was simulated with their bones oriented in both functional and neutral positions. 13% patients suffered a ROM impingement for functional but not neutral extension-ER. As a result, 48% patients who failed the functional-ER simulation would not be detected without consideration of the functional bony alignment. 16% patients suffered a ROM impingement for functional but not neutral flexion. As a result, 65% patients who failed the flexion simulation would not be detected without consideration of the functional bony alignment. We have developed a ROM simulation for use with preoperative planning for THA surgery that can solve bony and prosthetic impingement limits instantaneously. The advantage of our ROM simulation over previous simulations is instantaneous impingement detection, not requiring implant geometries to be analysed prior to use, and addressing the functional position of both the femur and pelvis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 47 - 47
1 Dec 2022
Sheridan G Clesham K Garbuz D Masri B
Full Access

The benefits of HXLPE in total knee arthroplasty (TKA) have not been as evident as total hip arthroplasty (THA). A systematic review and meta-analysis to assess the impact of highly-crosslinked polyethylene (HXLPE) on TKA outcomes compared to conventional polyethylene (CPE) is described. All studies comparing HXLPE with CPE for primary TKA were included for analysis. The minimum dataset included revision rates, indication for revision, aseptic component loosening and follow-up time. The primary outcome variables were all-cause revision, aseptic revision, revision for loosening, radiographic component loosening, osteolysis and incidence of radiolucent lines. Secondary outcome measures included postoperative functional knee scores. A random-effects meta-analysis allowing for all missing data was performed for all primary outcome variables. Six studies met the inclusion criteria. In total, there were 2,234 knees (1,105 HXLPE and 1,129 CPE). The combined mean follow-up for all studies was 6 years. The aseptic revision rate in the HXLPE group was 1.02% compared to 1.97% in the CPE group. There was no difference in the rate of all-cause revision (p = 0.131), aseptic revision (p = 0.298) or revision for component loosening (p = 0.206) between the two groups. Radiographic loosening (p = 0.200), radiolucent lines (p = 0.123) and osteolysis (p = 0.604) was similar between both groups. Functional outcomes were similar between groups. The use of HXLPE in TKA yields similar results for clinical and radiographic outcomes when compared to CPE at midterm follow-up. HXLPE does not confer the same advantages to TKA as seen in THA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 46 - 46
10 Feb 2023
Tuffley C Tuffley J Donnelly W Harris I Cuthbert A
Full Access

In this study we compare survivorship and patient reported outcome measures in robotically assisted versus conventional Total Hip Arthroplasty (THA). This paper investigates the hypothesis that implant survival and PROMS following THAs performed with robotic assistance were not different to outcomes following conventional THAs. Data included all patients undergoing THA for osteoarthritis between 19 April 2016 and 31 December 2020. Analysis of PROMS outcomes was restricted to those who had completed PROMS data preoperatively and at 6 months postoperatively. There were 157,647 procedures, including 3567 robotically assisted procedures, available for comparison of revision rates. 4557 procedures, including 130 robotically assisted procedures, had PROMS data available. The revision rate of primary THA performed with robotic assistance was not statistically different from THA performed by conventional methods (4 year cumulative percent revision 3.1% v 2.7%; HR = 1.05, p=0.67). The Oxford Hip Score, VAS for pain and the EQ-VAS score for overall health showed no statistically significant difference between the groups. The EQ-5D Utility Score showed an improved score (median score 1 v 0.88; OR = 1.58, p=0.007) for the robotically assisted group compared to the conventional group. Robotic assisted THA was not associated with significant improvement in early revision or joint-specific PROMs. The findings may have been biased, in either direction, by unmeasured patient, surgeon, hospital and prosthesis factors. The findings (including the difference in health-related quality of life) may have also been influenced by lack of blinding. Future research should include methods to minimise these biases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 55 - 55
24 Nov 2023
Wildeman P Rolfson O Wretenberg P Nåtman J Gordon M Söderquist B Lindgren V
Full Access

Aim. Prosthetic joint infection (PJI) is a serious complication following total hip arthroplasty (THA) entailing increased mortality, decreased quality of life, and high healthcare costs. In 2009 a nationwide, multidisciplinary infection control program was launched in Sweden, PRISS, which aimed to reduce the PJI burden by 50%. The primary aim was to investigate whether the PRISS project reduced PJI incidence after primary THA; the secondary aim was to evaluate other possible benefits of PRISS, such as shorter time to diagnosis. Method. We obtained data on patients undergoing primary THA in Sweden (n = 45,723 patients, 49,946 THAs), 2012–2014. Using personal identity numbers, this cohort was matched with the Swedish Prescribed Drug Registry. Medical records of patients with ≥4 weeks antibiotic consumption were reviewed to verify PJI diagnosis (n = 2240, 2569 THAs). Results. The cumulative incidence of PJI following the PRISS project was 1.2% [95% CI 1.1–1.3] as compared to 0.9% [95% CI 0.8–1.0] before. Cox regression models for the PJI incidence post PRISS indicates there were no statistical significance difference versus pre PRISS (HR 1.1 [95% CI 0.9–1.3]. There were similar time to PJI diagnosis after the PRISS project 24 vs 23 days (p=0.5). Conclusions. Despite the comprehensive nationwide PRISS project, Swedish PJI incidence was higher after the project and time to diagnosis remained unchanged. Factors contributing to PJI, such as increasing obesity, higher ASA class, and more fractures as indications, explain the PJI increase among primary THA patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 109 - 109
23 Feb 2023
Naufal E Shadbolt C Elsiwy Y Thuraisingam S Lorenzo Y Darby J Babazadeh S Choong P Dowsey M Stevens J
Full Access

This study aimed to evaluate the month-to-month prevalence of antibiotic dispensation in the 12 months before and after total knee arthroplasty (TKA) and total hip arthroplasty (THA) and to identify factors associated with antibiotic dispensation in the month immediately following the surgical procedure. In total, 4,115 THAs and TKAs performed between April 2013 and June 2019 from a state-wide arthroplasty referral centre were analysed. A cross-sectional study used data from an institutional arthroplasty registry, which was linked probabilistically to administrative dispensing data from the Australian Pharmaceutical Benefits Scheme. Multivariable logistic regression was carried out to identify patient and surgical risk factors for oral antibiotic dispensation. Oral antibiotics were dispensed in 18.3% of patients following primary TKA and 12.0% of patients following THA in the 30 days following discharge. During the year after discharge, 66.7% of TKA patients and 58.2% of THA patients were dispensed an antibiotic at some point. Patients with poor preoperative health status were more likely to have antibiotics dispensed in the month following THA or TKA. Older age, undergoing TKA rather than THA, obesity, inflammatory arthritis, and experiencing an in-hospital wound-related or other infectious complications were associated with increased antibiotic dispensation in the 30 days following discharge. A high rate of antibiotic dispensation in the 30 days following THA and TKA has been observed. Although resource constraints may limit routine wound review for all patients by a surgeon, a select cohort may benefit from timely specialist review postoperatively. Several risk factors identified in this study may aid in identifying appropriate candidates for such changes to follow-up care


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 52 - 52
24 Nov 2023
Szymski D Walter N Hierl K Rupp M Alt V
Full Access

Aim. The number of periprosthetic joint infections (PJI) is increasing due to ageing population and increasing numbers of arthroplasty procedures and treatment is costly. Aim of the study was to analyze the direct healthcare costs of PJI in Europe for total hip arthroplasties (THA) and total knee arthroplasties (TKA). Method. A systematic review in PubMed with search of direct costs of PJI in European countries was performed. Thereby the term cost* AND (infection OR PJI) AND (prosthesis OR knee OR hip OR “TKA” OR “THA” OR arthroplast*) was combined with each European country to detect relevant publications. Publications with definition of performed procedure and joint localization were included into further analysis. The mean value of direct healthcare cost was calculated for the respective joint and the respective operation performed. Results. Screening revealed 1,274 eligible publications. After review of abstracts and full-texts n=11 manuscripts were included into final analysis (Figure 1). The mean combined direct hospital costs for revision for PJI after TKA and THA was 26,311€. Mean costs for revision procedures for PJI after TKA were 24,617€. Direct costs for TKA-PJI treated with debridement, antibiotics and implant retention (DAIR) were on average 10,121€. For two-stage revisions in knee arthroplasties total average costs were 30,829€. Referring to revision surgery for PJI in THA, the mean hospital costs in Europe were 28,005€. For a DAIR procedure direct healthcare costs of 5,528€ were identified. Two-stage revision cost on average 31,217€. Conclusions. PJIs are associated with significant direct healthcare costs. The financial burden of up to 30,000 € per case underlines the impact of the disease for European health care system. However, the number of detailed reports on PJI costs is limited and the quality of the literature is limited. There is a strong need for more detailed financial data on the costs of PJI treatment. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 9 - 9
10 May 2024
Owen D
Full Access

Background. Increasing evidence suggests a link between the bearing surface used in total hip arthroplasty (THA) and the occurrence of infection. It is postulated that polyethylene has immunomodulatory effects and may influence bacterial function and survival, thereby impacting the development of periprosthetic joint infection (PJI). This study aimed to investigate the association between polyethylene type and revision surgery for PJI in THA using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). We hypothesized that the use of XLPE would demonstrate a statistically significant reduction in revision rates due to PJI compared to N-XLPE. Methods. Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) spanning September 1, 1999, to December 31, 2021, were used to compare the infection revision rates between THA using N-XLPE and XLPE. We calculated the Cumulative Percentage Revision rate (CPR) and Hazard Ratio (HR) while controlling for factors like age, sex, body mass index (BMI), American Society of Anesthesiologists’ (ASA) grade, and head size. Results. From the total 361,083 primary THAs, 26,827 used N-XLPE and 334,256 used XLPE. Excluding data from the first 6 months post-surgery, 220 revisions occurred in the N-XLPE group and 1,055 in the XLPE group for PJI. The HR for infection revision was significantly higher in N-XLPE compared to XLPE, at 1.64 (95% CI, 1.41–1.90, p<0.001). Conclusions. This analysis provides evidence of an association between N-XLPE and revision for infection in THA. We suspect that polyethylene wear particles contribute to the susceptibility of THA to PJI, resulting in a significantly higher risk of revision for infection in N-XLPE hips compared to those with XLPE. Level of Evidence. Therapeutic Level III


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 36 - 36
1 Dec 2022
Gazendam A Tushinski D Patel M Bali K Petruccelli D Winemaker MJ de Beer J Gillies L Best K Fife J Wood T
Full Access

Same day home (SDH) discharge in total joint arthroplasty (TJA) has increased in popularity in recent years. The objective of this study was to evaluate the causes and predictors of failed discharges in planned SDH patients. A consecutive cohort of patients who underwent total knee (TKA) or total hip arthroplasty (THA) that were scheduled for SDH discharge between April 1, 2019 to March 31, 2021 were retrospectively reviewed. Patient demographics, causes of failed discharge, perioperative variables, 30-day readmissions and 6-month reoperation rates were collected. Multivariate regression analysis was undertaken to identify independent predictors of failed discharge. The cohort consisted of 527 consecutive patients. One hundred and one (19%) patients failed SDH discharge. The leading causes were postoperative hypotension (20%) and patients who were ineligible for the SDH pathway (19%). Two individual surgeons, later operative start time (OR 1.3, 95% CI, 1.15-1.55, p=0.001), ASA class IV (OR 3.4, 95% CI, 1.4-8.2; p=0.006) and undergoing a THA (OR 2.0, 95% CI, 1.2-3.1, p=0.004) were independent predictors of failed SDH discharge. No differences in age, BMI, gender, surgical approach or type of anesthetic were found (p>0.05). The 30-day readmission or 6-month reoperation were similar between groups (p>0.05). Hypotension and inappropriate patient selection were the leading causes of failed SDH discharge. Significant variability existed between individual surgeons failed discharge rates. Patients undergoing a THA, classified as ASA IV or had a later operative start time were all more likely to fail SDH discharge


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 20 - 20
10 May 2024
Sim K Zhu M Young S
Full Access

Introduction. Individuals with significant hip and knee trauma receive total knee (TKA) and total hip arthroplasty (THA) as definitive end-stage procedures. In Aotearoa, injury-related costs, including workers compensation, may be funded by ACC. With a steady increase of arthroplasty procedures in Aotearoa, we aim to understand the magnitude and characteristics of such procedures to inform future healthcare strategies. Method. This is a longitudinal collaborative study from 1st January 2000 to 31st December 2020, using ACC and New Zealand Joint Registry databases. Total cost was subcategorised into social and medical cost for analysis. Results. ACC funded 10179 TKA and 5611 THA, amounting to 918 million New Zealand Dollars. Most clients were between 55 and 65 years of age at time of surgery, with greater representation by Male sex and European prioritised ethnicity. Māori and Pacific peoples represent less than 10% of the study population. ACC identified requiring more than 182 days of workers’ compensation as a significant marker for needing additional supports. Risk of this was 21% for TKA and 11% for THA, with risk factors being younger age (RR 0.96), Male sex (TKA RR 1.12, THA RR 1.23), and heavy work-types (TKA RR 1.50, THA RR 1.57). Discussion. Supporting individuals with post-traumatic lower limb arthroplasty is costly. Workers’ compensation contributes to a significant proportion of social expenditure. Risk factors for increased cost utilisation can be used to highlight vulnerable clients and target interventions. Conclusions. This is one of few nationwide studies investigating the healthcare cost of post-traumatic lower limb arthroplasty. We need to focus on injury prevention, targeted treatment, and rehabilitation protocols to improve recovery and reduce time off work. These findings would be of interest to multiple stakeholders


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 39 - 39
1 Dec 2022
Grammatopoulos G Pierrepont J Madurawe C Innmann MM Vigdorchik J Shimmin A
Full Access

A stiff spine leads to increased demand on the hip, creating an increased risk of total hip arthroplasty (THA) dislocation. Several authors propose that a change in sacral slope of ≤10° between the standing and relaxed-seated positions (ΔSSstanding→relaxed-seated) identifies a patient with a stiff lumbar spine and have suggested use of dual-mobility bearings for such patients. However, such assessment may not adequately test the lumbar spine to draw such conclusions. The aim of this study was to assess how accurately ΔSSstanding→relaxed-seated can identify patients with a stiff spine. This is a prospective, multi-centre, consecutive cohort series. Two-hundred and twenty-four patients, pre-THA, had standing, relaxed-seated and flexed-seated lateral radiographs. Sacral slope and lumbar lordosis were measured on each functional X-ray. ΔSSstanding→relaxed-seated seated was determined by the change in sacral slope between the standing and relaxed-seated positions. Lumbar flexion (LF) was defined as the difference in lumbar lordotic angle between standing and flexed-seated. LF≤20° was considered a stiff spine. The predictive value of ΔSSstanding→relaxed-seated for characterising a stiff spine was assessed. A weak correlation between ΔSSstanding→relaxed-seated and LF was identified (r2= 0.15). Fifty-four patients (24%) had ΔSSstanding→relaxed-seated ≤10° and 16 patients (7%) had a stiff spine. Of the 54 patients with ΔSSstanding→relaxed-seated ≤10°, 9 had a stiff spine. The positive predictive value of ΔSSstanding→relaxed-seated ≤10° for identifying a stiff spine was 17%. ΔSSstanding→relaxed-seated ≤10° was not correlated with a stiff spine in this cohort. Utilising this simplified approach could lead to a six-fold overprediction of patients with a stiff lumbar spine. This, in turn, could lead to an overprediction of patients with abnormal spinopelvic mobility, unnecessary use of dual mobility bearings and incorrect targets for component alignment. Referring to patients ΔSSstanding→relaxed-seated ≤10° as being stiff can be misleading; we thus recommend use of the flexed-seated position to effectively assess pre-operative spinopelvic mobility


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 115 - 115
10 Feb 2023
Lin D Gooden B Lyons M Salmon L Martina K Sundaraj K Yong Yau Tai J O'Sullivan M
Full Access

The prevalence of gluteal tendinopathy (GT) associated with osteoarthritis of the hip is difficult to determine as it is frequently undiagnosed or misdiagnosed as trochanteric bursitis. Its relationship to total hip arthroplasty (THA) outcomes is currently unknown. The aim of this study was to determine the incidence of GT at the time of hip arthroplasty and examine the relationship between GT and patient reported outcomes (PROMS) before and after THA. Patients undergoing THA for primary osteoarthritis between August 2017 and August 2020 were recruited. Tendinopathy was assessed and graded at time of surgery. PROMS included the Oxford Hip Score (OHS), HOOS JR, EQ-5D, and were collected preoperatively and at one year after THA. Satisfaction with surgery was also assessed at 1 year. 797 patients met eligibility criteria and were graded as Grade 1: normal tendons (n =496, 62%), Grade 2: gluteal tendinopathy but no tear (n=222, 28%), Grade 3: partial/full thickness tears or bare trochanter (n=79, 10%). Patients with abnormal gluteal tendons were older (p=0.001), had a higher mean BMI (p=0.01), and were predominately female (p=0.001). Patients with higher grade tendinopathy had statistically significant inferior PROMS at one year, OHS score (44.1 v 42.9 v 41.3, p 0.001) HOOS JR (89.3 V 86.3 V 85.6 p 0.005). Increasing gluteal tendon grade was associated with a greater incidence of problems with mobility (p=0.001), usual activities (p=0.001) and pain (p=0.021) on EQ5D. There was a 3 times relative risk of overall dissatisfaction with THA in the presence of gluteal tears. This study demonstrated that gluteal tendinopathy was commonly observed and associated with inferior 1-year PROMS in patients undergoing THA for OA. Increasing degree of tendinopathy was a negative prognostic factor for worse functional outcomes and patient satisfaction


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 77 - 77
10 Feb 2023
Hooper G Thompson D Lash N Sharr J Faulkner D Frampton C Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship