Nicolas AP Ramaskandhan J Nurm T Siddique M
Full Access

Introduction. Total ankle replacement as a valid treatment for end stage ankle arthritis, is gaining popularity and every year there is an increasing number of procedures. With revision rates as high as 21% at 5 years and 43% at 10 years there is a need for understanding and reporting the outcome of revision ankle replacement. Our aim was to study the patient reported outcomes following revision TAR with a minimum of 2 year follow up. Methods. All patients that underwent a revision total ankle replacement between 2012 and 2016 were included in the study. All patients received a post-operative questionnaire comprising of MOX-FQ score, EQ-5D (UK) and Foot and Ankle outcomes scores (FAOS) and patients satisfaction questionnaire with a minimum of 2 years follow up. Results. 33 patients had a revision total ankle replacement between 2012 and 2016. 2 patients were deceased therefore 31 patients were included in the study. 4 patients declined participation for completing questionnaires. We received 15/27 (55.5%) completed questionnaires. The mean MOX-FQ average domain score for pain was (50.6 ± 26.9), walking/standing (62.4 ± 36.5) and social function was (43.7± 31.0). The mean FAOS scores were (52.5 ± 30.6; pain), (54.5 ± 29.2; symptoms), (62.1 ± 30.5; ADL) and (35.5 ± 28.2; for quality of life). The mean overall health score today for EQ-5D was 73.9/100. 50% of patients were satisfied with the pain relief and return to sports and recreation obtained following the operation, 57% were satisfied with the improved in daily activities. 78.5% were overall satisfied with the results from surgery. Conclusion. Revision total ankle replacement gives overall satisfactory results demonstrated from patients reported outcomes at a minimum of 2 years following surgery


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 472 - 478
1 Apr 2022
Maccario C Paoli T Romano F D’Ambrosi R Indino C Federico UG

Aims. This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years. Methods. We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up. Results. A total of 86 patients were evaluated at a mean follow-up of 65.4 months (60 to 90). At five-year follow-up, statistically significant improvements (p < 0.001) were found in the mean American Orthopaedic Foot & Ankle Society Ankle Hindfoot Score (from 33.8 (SD 14.3) to 86.1 (SD 8.8)), visual analogue scale for pain (from 8.5 (SD 1.7) to 1.5 (SD 1.2)), Short Form-12 Physical and Mental Component Scores (from 29.9 (SD 6.7) and 43.3 (SD 8.6) to 47.3 (SD 7.5) and 52.2 (SD 8.0), respectively), and mean ankle dorsiflexion and plantarflexion (from 6.2° (SD 5.5°) and 9.6° (SD 5.8°) to 23.9° (SD 7.7°) and 16.9° (SD 7.2°), respectively). Radiologically, the implants maintained neutral alignment without subsidence. Tibial or talar radiolucency was found in eight patients, but none of these patients was symptomatic. At five-year follow up, 97.7% of implants (95% confidence interval 91.2 to 99.4) were free from revision or removal with 84 implants at risk. We recorded two cases (2.3%) of failure for septic loosening. Conclusion. Transfibular TAA is safe and effective with a high survival rate at mid-term follow-up and satisfactory clinical and radiological results. Further studies are required to determine the long-term performance of these implants. Cite this article: Bone Joint J 2022;104-B(4):472–478


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1352 - 1358
1 Oct 2018
Clough TM Alvi F Majeed H

Aims. Total ankle arthroplasty (TAA) surgery is complex and attracts a wide variety of complications. The literature lacks consistency in reporting adverse events and complications. The aim of this article is to provide a comprehensive analysis of each of these complications from a literature review, and to compare them with rates from our Unit, to aid clinicians with the process of informed consent. Patients and Methods. A total of 278 consecutive total ankle arthroplasties (251 patients), performed by four surgeons over a six-year period in Wrightington Hospital (Wigan, United Kingdom) were prospectively reviewed. There were 143 men and 108 women with a mean age of 64 years (41 to 86). The data were recorded on each follow-up visit. Any complications either during initial hospital stay or subsequently reported on follow-ups were recorded, investigated, monitored, and treated as warranted. Literature search included the studies reporting the outcomes and complications of TAA implants. Results. There were wound-healing problems in nine ankles (3.2%), superficial infection in 20 ankles (7.2%), and deep infection in six ankles (2.2%). Intraoperative fractures occurred in medial malleoli in 27 ankles (9.7%) and in lateral malleoli in four ankles (1.4%). Aseptic loosening and osteolysis were seen 16 ankles (5.8%). Fracture of the polyethylene component occurred in one ankle (0.4%) and edge-loading in seven ankles (2.5%). We observed medial gutter pain in 31 ankles (11.1%). The incidence of thromboembolism occurred in two ankles (0.7%). The results were found to be comparable to the previously reported complications of total ankle arthroplasty in the literature. Conclusion. Total ankle arthroplasty continues to evolve and improve the ankle function. Despite high overall complication rates with TAA surgery, most complications appear to be minor and do not affect final clinical outcome. Our results and literature review will help in the consent process and provide detailed complication rates for an informed consent. Cite this article: Bone Joint J 2018;100-B:1352–8


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 985 - 992
1 Sep 2023
Arshad Z Haq II Bhatia M

Aims. This scoping review aims to identify patient-related factors associated with a poorer outcome following total ankle arthroplasty (TAA). Methods. A scoping review was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A computer-based literature search was performed in PubMed, Embase, Cochrane trials, and Web of Science. Two reviewers independently performed title/abstract and full-text screening according to predetermined selection criteria. English-language original research studies reporting patient-related factors associated with a poorer outcome following TAA were included. Outcomes were defined as patient-reported outcome measures (PROMs), perioperative complications, and failure. Results. A total of 94 studies reporting 101,552 cases of TAA in 101,177 patients were included. The most common patient-related risk factor associated with poorer outcomes were younger age (21 studies), rheumatoid arthritis (17 studies), and diabetes (16 studies). Of the studies using multivariable regression specifically, the most frequently described risk factors were younger age (12 studies), rheumatoid arthritis (eight studies), diabetes (eight studies), and high BMI (eight studies). Conclusion. When controlling for confounding factors, the most commonly reported risk factors for poor outcome are younger age, rheumatoid arthritis, and comorbidities such as diabetes and increased BMI. These patient-related risk factors reported may be used to facilitate the refinement of patient selection criteria for TAA and inform patient expectations. Cite this article: Bone Joint J 2023;105-B(9):985–992


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 475 - 481
1 May 2024
Lee M Lee G Lee K

Aims. The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan. Methods. We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured. Results. Out of 37 ankles, graft incorporation was successful in 30 cases. Among the remaining seven cases, four (10.8%) exhibited cyst re-progression, so secondary bone grafting was needed. After secondary bone grafting, no further progression has been noted, resulting in an overall 91.9% success rate (34 of 37) at a mean follow-up period of 47.5 months (24 to 120). The remaining three cases (8.1%) showed implant loosening, so tibiotalocalcaneal arthrodesis was performed. Functional outcomes were also improved after bone grafting in all variables at the latest follow-up (p < 0.05). The mean incorporation rate of the grafts according to the location of the cysts was 84.8% (55.2% to 96.1%) at the medial malleolus, 65.1% (27.6% to 97.1%) at the tibia, and 81.2% (42.8% to 98.7%) at the talus. Smoking was identified as a significant predisposing factor adversely affecting graft incorporation (p = 0.001). Conclusion. Bone grafting for periprosthetic bone cysts following primary TAA is a reliable procedure with a satisfactory success rate and functional outcomes. Regular follow-up, including CT scan, is important for the detection of cyst re-progression to prevent implant loosening after bone grafting. Cite this article: Bone Joint J 2024;106-B(5):475–481


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 696 - 703
1 Apr 2021
Clough TM Ring J

Aims. We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Methods. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year. Results. Eight patients (ten ankles) died during follow-up, but none required revision. Of the surviving 106 patients (108 ankles: rheumatoid arthritis (RA), n = 15; osteoarthritis (OA), n = 93), 38 were women and 68 were men, with a mean age of 68.2 years (48 to 86) at the time of surgery. Mean follow-up was 5.1 years (2.1 to 9.0). A total of ten implants failed (8.5%), thus requiring revision. The implant survival at seven years, using revision as an endpoint, was 88.2% (95% CI 100% to 72.9%). There was a mean improvement in Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ) from 85.0 to 32.8 and visual analogue scale (VAS) scores from 7.0 to 3.2, and overall satisfaction was 89%. The three commonest complications were malleolar fracture (14.4%, n = 17), wound healing (13.6%, n = 16), and superficial infection (12.7%, n = 15). The commonest reason for revision was aseptic loosening. No patients in our study were revised for deep infection. Conclusion. Our results show that Zenith survival rates are comparable with those in the literature for other implants and in the National Joint Registry (NJR). Overall patient satisfaction was high as were functional outcomes. However, the data highlight potential complications associated with this surgery. The authors believe that these figures support ankle arthroplasty as an option in the treatment of ankle arthritis. Cite this article: Bone Joint J 2021;103-B(4):696–703


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 7 - 7
8 May 2024
Cunningham I Kumar C
Full Access

Aim. Surgical options for management of a failed ankle arthroplasty are currently limited; typically conversion to fusion is recommended with only a few patients being considered for revision replacement surgery. This paper presents our experience of revision ankle replacements in a cohort of patients with failed primary replacements. Method. A total of 18 revision TAR in 17 patients were performed in patients with aseptic loosening. The technique was performed by a single surgeon (CSK) over a 4 year period between July 2014 and August 2018 using the Inbone total ankle replacement system. Patient demographics and clinical outcomes were collected retrospectively using - MOXFQ, EQ5D, VAS pain score and patient satisfaction questionnaires. Results. 12 right and 6 left ankle replacements were revised in 17 patients (11 male/ 6 female). The mean age at revision was 69.1 years (range 56–81 years) with a mean BMI of 31. The mean surgical time was 171 minutes with 22% of cases requiring bone grafting. 6 patients had early wound complications, all superficial and settled with dressings. There were no deep infections, 2 patients had further surgery for exploration for possible nerve injuries. At a mean follow up of 20.6 months, 4 patients had mild/moderate ongoing pain with the majority of patients being satisfied with the outcome of their surgery. Conclusion. This study represents one of the largest group of patients reported to have undergone revision total ankle arthroplasty. Our experience shows that this results in acceptable level of complications and provides satisfactory function in most patients. We feel revision TAR is a viable option in patients with failed primary arthroplasty who wish to continue to maintain mobility at the ankle joint


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 22 - 22
16 May 2024
Drake B Blundell M Gibson B Kingman A Kakwani R Townshend D
Full Access

Introduction. Day Case Surgery (defined as same day discharge) is a priority within the National Health Service and has been shown to provide beneficial outcomes for patients and hospitals. We report our experience developing a Day Case Programme for Total Ankle Replacement (TAR). Methods. Prior to the introduction of a Day Case Programme, average length of stay following TAR in our unit was 3.5 days. Stakeholders were consulted about ways in which same day discharge could be facilitated. Patients' post-operative pain charts were reviewed prior to the introduction of this programme. Inclusion criteria included non-complex surgery (anticipated tourniquet < 2hrs), friend or relative support and pre-operative walking-aid assessment. An enhanced recovery protocol included long-acting popliteal block and dexamethasone. Patients were discharged with opiate analgesia and written pain instructions. Patients were asked to complete a pain and satisfaction questionnaire. Patient Reported Outcome Measures (PROMs) were recorded. Results. From September 2017 to April 2019 21 of 70 patients underwent TAR as a Day Case. Mean age was 67 years (43-85 years). Complications included two delayed wound healings and one representation on day three with urinary retention. No patients reported post-operative nausea or vomiting, 60% did not use Oramorph at home. Average Visual Analogue Score for pain was 23/100 on day one and 21/100 day three post-operatively. There was no significant difference in pre-operative or overall change in MOXFQ, VAS or EQ5D PROMS. Conclusions. Early results suggest that Day Case Total Ankle Replacements are safe. Appropriate patient selection is necessary. Day Case Surgery relies on support and communication between multiple teams to organise and run effectively


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 605 - 609
1 May 2008
Wood PLR Prem H Sutton C

We describe the medium-term results of a prospective study of 200 total ankle replacements at a single-centre using the Scandinavian Total Ankle Replacement. A total of 24 ankles (12%) have been revised, 20 by fusion and four by further replacement and 27 patients (33 ankles) have died. All the surviving patients were seen at a minimum of five years after operation. The five-year survival was 93.3% (95% confidence interval (CI) 89.8 to 96.8) and the ten-year survival 80.3% (95% CI 71.0 to 89.6). Anterior subluxation of the talus, often seen on the lateral radiograph in osteoarthritic ankles, was corrected and, in most instances, the anatomical alignment was restored by total ankle replacement. The orientation of the tibial component, as seen on the lateral radiograph, also affects the position of the talus and if not correct can hold the talus in an abnormal anterior position. Subtalar arthritis may continue to progress after total ankle replacement. Our results are similar to those published previously


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 16 - 16
16 May 2024
Ha T Higgs Z Watling C Osam C Madeley N Kumar C
Full Access

Introduction. Total ankle replacement (TAR) is performed for post-traumatic arthritis, inflammatory arthropathy, osteoarthritis and other indications. The Scottish Arthroplasty Project (SAP) began collection of data on TAR in 1997. In this study, using data from the SAP, we look at trends in the use and outcomes of TAR in Scotland. Methods. We identified 499 patients from the SAP who underwent TAR between 1997 and 2015 with imaging available on the National Picture Archiving and Communication System (PACS). We identified, and looked at trends in, implant type over the following time periods: 1998–2005; 2006–2010 and 2011–2015. Age, gender, indication and outcomes for each time period were examined and also trends with implant type over time. Results. There were 499 primary TAR procedures with an overall incidence of 0.5/10. 5. population per year. Eight different implants were identified with significant changes in the numbers of each type used over time. The peak incidence of TAR was in the 6th decade. The mean age of patients undergoing TAR from 59 years in 1997–2005, to 65 years in 2011–15 (p< 0.0001). The percentage of patients with inflammatory arthropathy was 52% in 1997–2005, compared with 10% in 2011–2015. Subsequent arthrodesis and infection rates appeared to be higher during the first time period. The female to male ratio also changed over time. The incidence of TAR increased overall during the study period (r= 0.9, p=< 0.0001). This may be due to a broadening range of indications and patient selection criteria, in turn due to increased surgeon experience and the evolution of implant design. Conclusion. This study examines a large number of TARs from an established arthroplasty registry. The rate of TAR has increased significantly in Scotland from 1997 to 2015. Indication and patient age has changed over time and this could potentially impact outcomes after ankle replacement


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 18 - 18
16 May 2024
Najefi A Ghani Y Goldberg A
Full Access

Background. The importance of total ankle replacement (TAR) implant orientation in the axial plane is poorly understood with major variation in surgical technique of implants on the market. Our aims were to better understand the axial rotational profile of patients undergoing TAR. Methods. In 157 standardised CT Scans of end-stage ankle arthritis patients planning to undergo primary TAR surgery, we measured the relationship between the knee posterior condylar axis, the tibial tuberosity, the transmalleolar axis(TMA) and the tibiotalar angle. The foot position was measured in relation to the TMA with the foot plantigrade. The variation between medial gutter line and the line bisecting both gutters was assessed. Results. The mean external tibial torsion was 34.5±10.3°(11.8–62°). When plantigrade the mean foot position relative to the TMA was 21±10.6°(0.7–38.4°) internally rotated. As external tibial torsion increased, the foot position became more internally rotated relative to the TMA(pearson correlation 0.6;p< 0.0001). As the tibiotalar angle became more valgus, the foot became more externally rotated relative to the TMA(pearson correlation −0.4;p< 0.01). The mean difference between the medial gutter line and a line bisecting both gutters was 4.9±2.8°(1.7°-9.4°). More than 51% of patients had a difference greater than 5°. The mean angle between the medial gutter line and a line perpendicular to the TMA was 7.5°±2.6°(2.8°-13.7°). Conclusion. There is a large variation in rotational profile of patients undergoing TAR, particularly between the medial gutter line and the transmalleolar axis. Surgeon designers and implant manufacturers need to develop consistent methods to guide surgeons towards judging appropriate axial rotation of their implanton an individual basis. We recommend careful clinical assessment and CT scanspre-operatively to enable the correct rotation to be determined


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1540 - 1547
1 Nov 2010
Kim BS Knupp M Zwicky L Lee JW Hintermann B

We report the clinical and radiological outcome of total ankle replacement performed in conjunction with hindfoot fusion or in isolation. Between May 2003 and June 2008, 60 ankles were treated with total ankle replacement with either subtalar or triple fusion, and the results were compared with a control group of 288 ankles treated with total ankle replacement alone. After the mean follow-up of 39.5 months (12 to 73), the ankles with hindfoot fusion showed significant improvement in the mean visual analogue score for pain (p < 0.001), the mean American Orthopaedic Foot and Ankle Society score (p < 0.001), and the mean of a modified version of this score (p < 0.001). The mean visual analogue pain score (p = 0.304) and mean modified American Orthopaedic Foot and Ankle Society score (p = 0.119) were not significantly different between the hindfoot fusion and the control groups. However, the hindfoot fusion group had a significantly lower mean range of movement (p = 0.009) and a higher rate of posterior focal osteolysis (p = 0.04). Both groups showed various complications (p = 0.131) and failure occurring at a similar rate (p = 0.685). Subtalar or triple fusion is feasible and has minimal adverse effects on ankles treated with total ankle replacement up to midterm follow-up. The clinical outcome of total ankle replacement when combined with hindfoot fusion is comparable to that of ankle replacement alone. Thus, hindfoot fusion should be performed in conjunction with total ankle replacement when indicated


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 4 - 4
8 May 2024
Nurm T Ramaskandhan J Nicolas A Siddique M
Full Access

Introduction. Total ankle arthroplasty (TAA) is an increasingly popular treatment option for patients with end-stage ankle arthritis. However, for most implant systems, failure rates of 10–20% have been reported within the first 10 years after primary TAA. Pain is the primary symptom that indicates failure of TAA but cause of it can be difficult to establish. Methods. All patients who underwent a primary TAA at our center were included in the study. The clinical outcomes were studied for patients requiring a further revision procedure following primary TAA. The reasons for revision surgery and outcomes of surgery were analyzed using appropriate inferential statistical tests. Results. Between 2007 and 2018, 42 primary TAA required revisions in 40 patients. There were 25 men (59.5%) and 15 women (35.7%) with mean age of 57.5 years the time of primary TAA. All patients had undergone primary procedure at a mean duration of 3.5 years previously (range: 3 months to 10 years). Of the total revision procedures, 12/40 (30%) of revisions were carried out due to malalignment, 10/42 (23.8%) due to loosening of the implants or bone subsidence, 5/42 procedures (11.9%) following infection, 4/42 (9.5%) due to polyethylene migration, 1/42 (2.3%) due to fracture and 1/42 (2.3%) due to Charcot arthropathy. In 9/42 (21.4%) cases, imaging showed no objective reason for pain. 50% of patients who underwent revision TAA reported 78.5% satisfaction with results of surgery at 2 years follow up post-operatively. Conclusion. Major reasons for revising primary TAR at our centre are mal-alignment, implant loosening / bone subsidence and suspicion of infection and pain. In-spite of undergoing a complex revision surgery, patients report 78.5% satisfaction from outcomes of surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 20 - 20
17 Jun 2024
Jagani N Harrison W Davenport J Karski M Ring J Smith R Clough T
Full Access

Aims. Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure. Methods. All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR. Results. 156 (13.4%) TARs failed (47STAR 15.6%, 16BP 16%, 77Mobility 15.1%, 6Salto 14.6%, 10Zenith 8.5% and 0Infinity 0%). Mean time to failure 5.8 years (0.1- 21.4 years). The 4 most common modes of failure were 44.9% aseptic loosening, 11.5% gutter pain, 10.9% infection and 10.3% recurrent edge loading. 50 underwent conversion to tibiotalocalcaneal (TTC) fusion with nail with 9 (18%) failing to fuse. 31 underwent revision TAR with 2 (6.5%) subsequently failed. 22 underwent ankle fusion with 10 (45%) failing to fuse. 21 underwent polyethylene exchange of which 8 (38%) had further poly failure. 20 (12.8%) were managed conservatively, 2 (1.3%) required below knee amputation and 6 were listed but lost to follow-up. 81 of the 1168 (7%) consecutive cohort were lost to follow-up. Conclusions. 13.4% of the TAR cohort have failed at average follow-up 13.7 years. There was no difference in failure modes across the implant designs. Whilst the fixed bearing has the shortest follow-up, it may be performing better as there have been no failures so far. Prior to October 2016, most revisions were to fusion (TTC 18% failure rate, ankle 45% failure rate), whereas post 2016, 57% patients elected for revision TAR (6.5% failure)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 18 - 18
10 Jun 2024
Haston S Langton D Townshend D Bhalekar R Joyce T
Full Access

Despite advancements, revision rates following total ankle replacement (TAR) are high in comparison to other total joint replacements. This explant analysis study aimed to investigate whether there was appreciable metal particulate debris release from various contemporary TARs by describing patterns of material loss. Twenty-eight explanted TARs (9 designs: 3 fixed and 6 mobile bearing), revised for any reason, were studied. The articulating surfaces of the metal tibial and talar components as well as the polyethylene insert were assessed for damage features using light microscopy. Based on the results of the microscopic analysis, scanning electron microscopy with energy dispersive X-ray spectroscopy was performed to determine the composition of embedded debris identified, as well as non-contacting 3D profilometry. Pitting, indicative of material loss, was identified on the articulating surfaces of 54% of tibial components and 96% of talar components. Bearing constraint was not found to be a factor, with similar proportions of fixed and mobile bearing metal components showing pitting. More cobalt-chromium than titanium alloy tibial components exhibited pitting (63% versus 20%). Significantly higher average surface roughness (Sa) values were measured for pitted areas in comparison to unpitted areas of these metal components (p<0.05). Additionally, metallic embedded debris (cobalt-chromium likely due to pitting of the tibial and talar components or titanium likely from loss of their porous coatings) was identified in 18% of polyethylene inserts. The presence of hard 3. rd. body particles was also indicated by macroscopically visible sliding plane scratching, identified on 79% of talar components. This explant analysis study demonstrates that metal debris is released from the articulating surfaces and the coatings of various contemporary TARs, both fixed and mobile bearing. These findings suggest that metal debris release in TARs may be an under-recognised issue that should be considered in the study of painful or failed TAR moving forwards


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1270 - 1276
1 Jul 2021
Townshend DN Bing AJF Clough TM Sharpe IT Goldberg A

Aims. This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes. Methods. Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence. Results. In all, 500 patients reached six-month follow-up, 420 reached one-year follow-up, and 188 reached two-year follow-up. The mean age was 67.8 years (23.9 to 88.5). A total of 38 patients (7.5%) presented with inflammatory arthritis. A total of 101 (20.0%) of implantations used patient-specific instrumentation; 167 patients (33.1%) underwent an additional procedure at the time of surgery. A total of seven patients died of unrelated causes, two withdrew, and one was lost to follow-up. The mean follow-up was 16.2 months (6 to 36). There was a significant improvement from baseline across all functional outcome scores at six months, one, and two years. There was no significant difference in outcomes with the use of patient-specific instrumentation, type of arthritis, or COFAS type. Five (1.0%) implants were revised. The overall complication rate was 8.8%. The non-revision reoperation rate was 1.4%. The 30-day readmission rate was 1.2% and the one-year mortality 0.74%. Conclusion. The early experience and complications reported in this study support the current use of the INFINITY TAA as a safe and effective implant in the treatment of end-stage ankle arthritis. Cite this article: Bone Joint J 2021;103-B(7):1270–1276


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 958 - 962
1 Jul 2010
Wood PLR Karski MT Watmough P

We describe the early results of a prospective study of 100 total ankle replacements (96 patients) at a single centre using the Mobility Total Ankle Replacement. At final review, six patients had died and five ankles (5%) had been revised, two by fusion and three by exchange of components. All remaining patients were reviewed at a minimum of three years. The mean follow-up was 43 months (4 to 63). The three-year survival was 97% (95% confidence interval (CI) 91 to 99). The four-year survival was 93.6% (95% CI 84.7 to 97.4). The portion of bony interface that was visible on plain radiograph was divided into 15 zones and a radiolucent line or osteolytic cavity was seen in one zone in 14 ankles. It was not seen in more than one zone. In five ankles it was > 10 mm in width. This study suggests that the early outcome of ankle replacement is comparable to that of other total joint replacements


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 925 - 932
1 Jul 2020
Gaugler M Krähenbühl N Barg A Ruiz R Horn-Lang T Susdorf R Dutilh G Hintermann B

Aims. To assess the effect of age on clinical outcome and revision rates in patients who underwent total ankle arthroplasty (TAA) for end-stage ankle osteoarthritis (OA). Methods. A consecutive series of 811 ankles (789 patients) that underwent TAA between May 2003 and December 2013 were enrolled. The influence of age on clinical outcome, including the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, and pain according to the visual analogue scale (VAS) was assessed. In addition, the risk for revision surgery that includes soft tissue procedures, periarticular arthrodeses/osteotomies, ankle joint debridement, and/or inlay exchange (defined as minor revision), as well as the risk for revision surgery necessitating the exchange of any of the metallic components or removal of implant followed by ankle/hindfoot fusion (defined as major revision) was calculated. Results. A significant improvement in the AOFAS hindfoot score and pain relief between the preoperative assessment and the last follow-up was evident. Age had a positive effect on pain relief. The risk for a minor or major revision was 28.7 % at the mean follow-up of 5.4 years and 11.0 % at a mean follow-up of 6.9 years respectively. The hazard of revision was not affected by age. Conclusion. The clinical outcome, as well as the probability for revision surgery following TAA, is comparable between younger and older patients. The overall revision rate of the Hintegra total ankle is comparable with other three component designs. TAA should no longer be reserved for low demand elderly patients, but should also be recognized as a viable option for active patients of younger age. Cite this article: Bone Joint J 2020;102-B(7):925–932


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 3 - 3
4 Jun 2024
Jamjoom B Siddiqui B Salem H Raglan M Dhar S
Full Access

Background. The literature on the outcome of revision total ankle arthroplasty (TAA) remains limited. We aim to report the clinical and radiological outcomes of revision TAA at a high-volume centre in the UK. Methods. Retrospective review of 28 patients that underwent 29 revision TAA procedures using INBONE II prosthesis. Demographic, radiological, and patient reported outcome measures data were analysed. Results. The mean (range) duration from primary TAA to revision was 87.5 (16–223) months. The main indication for the revision was aseptic loosening of the primary TAA (82.8%). Additional procedures were required in 75.9% of patients. At mean (range) follow-up of 40 (24- 60) months, the infection, re-operation, and implant survival rates were 6.9%, 6.9% and 96.5% respectively. A significant postoperative improvement in the component alignment radiographic measures was observed. Osteolysis, subsidence, loosening and heterotopic ossification rates were comparable to other reports and did not influence the clinical outcome. A significant improvement was observed in the MOXFQ (all domains) and the EQ-5D (three domains) at 24 months postoperatively. Conclusions. Revision TAA using INBONE II was associated with good short-term survival and improvement in the postoperative scores at 2 years. Maintenance of the postoperatively improved alignment was documented at follow up. The relatively high survival rate in this series supports the notion that revision TAA is a satisfactory option for failed primary TAA


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 5 - 11
1 Jan 2017
Vulcano E Myerson MS

The last decade has seen a considerable increase in the use of in total ankle arthroplasty (TAA) to treat patients with end-stage arthritis of the ankle. However, the longevity of the implants is still far from that of total knee and hip arthroplasties. . The aim of this review is to outline a diagnostic and treatment algorithm for the painful TAA to be used when considering revision surgery. Cite this article: Bone Joint J 2017;99-B:5–11