Advertisement for orthosearch.org.uk
Results 1 - 20 of 33
Results per page:
Bone & Joint Research
Vol. 12, Issue 8 | Pages 497 - 503
16 Aug 2023
Lee J Koh Y Kim PS Park J Kang K

Aims. Focal knee arthroplasty is an attractive alternative to knee arthroplasty for young patients because it allows preservation of a large amount of bone for potential revisions. However, the mechanical behaviour of cartilage has not yet been investigated because it is challenging to evaluate in vivo contact areas, pressure, and deformations from metal implants. Therefore, this study aimed to determine the contact pressure in the tibiofemoral joint with a focal knee arthroplasty using a finite element model. Methods. The mechanical behaviour of the cartilage surrounding a metal implant was evaluated using finite element analysis. We modelled focal knee arthroplasty with placement flush, 0.5 mm deep, or protruding 0.5 mm with regard to the level of the surrounding cartilage. We compared contact stress and pressure for bone, implant, and cartilage under static loading conditions. Results. Contact stress on medial and lateral femoral and tibial cartilages increased and decreased, respectively, the most and the least in the protruding model compared to the intact model. The deep model exhibited the closest tibiofemoral contact stress to the intact model. In addition, the deep model demonstrated load sharing between the bone and the implant, while the protruding and flush model showed stress shielding. The data revealed that resurfacing with a focal knee arthroplasty does not cause increased contact pressure with deep implantation. However, protruding implantation leads to increased contact pressure, decreased bone stress, and biomechanical disadvantage in an in vivo application. Conclusion. These results show that it is preferable to leave an edge slightly deep rather than flush and protruding. Cite this article: Bone Joint Res 2023;12(8):497–503


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 18 - 18
1 Mar 2021
Babel H Omoumi P Jolles B Favre J
Full Access

While knee osteoarthritis (OA) is now recognized as a complex disease affecting the whole joint, not just the cartilages, there remains a paucity of data regarding the interactions between knee components. One relationship of particular interest is between the spatial variations in cartilage thickness (CTh) and subchondral bone mineral density (BMD). Indeed, bone and cartilage are two mechanosensitive tissues that interact as a functional unit and there is evidence of a biomechanical coupling between both tissues. Particularly, a recent in vivo study has shown a positive relationship in non-OA knees with thicker cartilage where bone is denser, and an alteration of this relationship in OA knees. These observations support the concept of an osteochondral unit and warrant additional research to assess the influence of bone depth. Therefore, this study aimed to characterize the relationship between spatial variations in CTh and BMD measured at various depths below the bone surface.

CT-arthrography of 20 non-OA tibias and 20 severe medial-compartment OA tibias were segmented to build 3D mesh models of the bones and cartilages. Each individual tibia model was registered to a reference tibia, allowing to calculate BMD maps at 1, 3, 5 and 10mm below the bone-cartilage interface in the medial compartment. Pearson correlations between CTh maps and the four BMD maps were then calculated for each knee. Lastly, differences in correlation coefficients between successive bone layers were assessed using Wilcoxon signed-rank tests.

In both OA and non-OA tibias, the correlation coefficients were higher with the BMD measured in the 1mm layer, and followed a pattern of statistically significant decrease with bone layers of increasing depth (p < 0.021). In non-OA tibias, the median relationship was positive with a strong effect size in the 1, 3 and 5mm layers, while in OA tibias the median relationship was positive only in the 1mm layer and with a medium effect size. In the OA tibias, the median relationship was negative with a weak effect size in the 3 and 5mm layers, and it was negative with a medium effect size in the 10mm layer.

In conclusion, the results of the present study support the value of considering bone and cartilage as a unit, and more generally support OA pathophysiology models based on relationships among knee properties.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 93 - 93
1 Dec 2020
Unal OK Dagtas MZ Demir C Najafov T Ugutmen E
Full Access

Abstract. Background. Proximal fibular osteotomy (PFO) was defined to provide a treatment option for knee pain caused by gonarthrosis(1). Minor surgical procedure, low complication rate and dramatic pain relief were the main reasons for popularization of this procedure(2, 3). However, changes at the knee and ankle joint after PFO were not clarified objectively in the literature. Questions/purposes. We asked: 1) Does PFO change the maximum and average pressures at the medial and lateral chondral surface of the tibia plateau? 2) Are chondral surface stresses redistributed at the knee and ankle joint after PFO? 3)Does PFO change the distribution of total load on the knee joint? 4) Can PFO lead to change in alignment of lower limb?. Methods. This study was conducted at Maltepe University Faculty of Medicine Hospital, Orthopedics and Traumatology Department and Yildiz Technical University Mechanical Engineering Department in Istanbul, Turkey, between September 2019 and February 2020. Finite element analysis (FEA) was used to evaluate effects of PFO(4). One 62 years old, female volunteer's X-ray, computer tomography and magnetic resonance imaging images were used for creating right lower limb model. Two different lower limb models were created. One of them was osteotomized model (OM) which was created according to definition of PFO and the other was non-osteotomized model (NOM). To obtain a stress distribution comparison between the two models, 350 N of axial force was applied to the femoral heads of the models. Results. After PFO, the maximum contact pressures at the medial and lateral tibial cartilages decreased 83.2% and 66.9%, respectively at the knee joint. The average contact pressure decreased 26.1% at the medial tibial cartilage and increased 42.4% at the lateral tibial cartilage. The Von Mises stresses decreased 57.1% at the femoral cartilage and decreased 79.1% at tibial cartilage. The stress on the tibial cartilage increased 44.6%, and stress on the talar cartilage increased 7.1% at the ankle joint. Under a 350 N axial force, distribution of the total load at the knee joint was changed and become more homogenous in OM compared to NOM. Change in lower extremity alignment after PFO could not be evaluated with FEA. Conclusion. FEA revealed that PFO causes some changes in knee and ankle joint kinematics. Main loading at the knee joint shifted from medial tibial cartilage to the lateral tibial cartilage after PFO. Additionally, the stresses on each cartilage were redistributed across a wider and more peripheral area. These changes could be the main reason for pain relief at the knee joint. FEA also demonstrated that the Von Mises stresses of the tibial and talar cartilages of the ankle joint increased after PFO. This stress increase may cause long-term arthritic changes in the ankle joint. Level IV; in silico study


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 143 - 143
1 Apr 2019
Hillstrom R Morgan OJ Rozbruch SR Fragomen AT Ranawat A Hillstrom H
Full Access

Introduction. Osteoarthritis (OA), a painful, debilitating joint disease, often caused by excessive joint stress, is a leading cause of disability (World Health Organisation, 2003) and increases with age and obesity. A 5° varus malalignment increases loading in the medial knee compartment from 70% to 90% (Tetsworth and Paley, 1994). Internal unloading implants, placed subcutaneously upon the medial aspect of the knee joint, are designed to offload the medial compartment of the knee without violating natural joint tissues. The aim of this study is to investigate the effect of an unloading implant, such as the Atlas™ knee system, on stress within the tibiofemoral joint with different grades of cartilage defects. Methods. To simulate surgical treatment of medial knee OA, a three-dimensional computer-aided design of an Atlas™ knee system was virtually fixed to the medial aspect of a validated finite element knee model (Mootanah, 2014), using CATIA v5 software (Dassault Systèmes, Velizy Villacoublay, France). The construct was meshed and assigned material properties and boundary conditions, using Abaqus finite element software (Dassault Systèmes, Velizy Villacoublay, France). A cartilage defect was simulated by removing elements corresponding to 4.7 mm. 2. The international cartilage repair society (ICRS) Grade II and III damage were simulated by normalized defect depth of 33% and 67%, respectively. The femur was mechanically grounded and the tibia was subjected to loading conditions corresponding to the stance phase of walking of a healthy 50-year-old 68-Kg male with anthropometrics that matched those of the cadaver. Finite element analyses were run for peak shear and von Mises stress in the medial and lateral tibiofemoral compartments. Results. Von Mises stress distribution in the tibial cartilage, with ICRS Grade II and III defects, without the unloading implant, at the end of weight acceptance (15% of the gait cycle) were analysed. The internal unloading implant reduces peak von Mises stress by 40% and 43% for Grade II and Grade III cartilage defects, respectively. The corresponding reductions in shear stress are 36% and 40%. Consistent reduction in peak von Mises stress values in the medial cartilage-cartilage and cartilage-meniscus contact areas were predicted throughout the stance phase of the gait cycle for ICRS Grade II defect. Similar results were obtained for Grade III defect and for peak shear stress values. There were no overall increases in peak von Mises stress values in the lateral tibial cartilage. Discussion and Conclusions. The internal unloading implant is capable of reducing von Mises and shear stress values in the medial tibial cartilage with ICRS Grade II and III defects at the cartilage-cartilage and cartilage-meniscus interfaces throughout the stance phase of the gait cycle. This did not result in increased stress values in the lateral tibial cartilage. Our model did not account for the viscoelastic effects of the cartilage and meniscus. Results of this study are based on only one knee specimen. The internal unloading implant may protect the cartilage in individuals with medial knee osteoarthritis, thereby delaying the need for knee replacements


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 4 - 4
2 Jan 2024
Han S Yoo Y Choi H Lee K Korhonen R Esrafilian A
Full Access

It is known that the gait dynamics of elderly substantially differs from that of young people. However, it has not been well studied how this age-related gait dynamics affects the knee biomechanics, e.g., cartilage mechanical response. In this study, we investigated how aging affects knee biomechanics in a female population using subject-specific computational models. Two female subjects (ages of 23 and 69) with no musculoskeletal disorders were recruited. Korea National Institute for Bioethics Policy Review Board approved the study. Participants walked at a self-selected speed (SWS), 110% of SWS, and 120% of SWS on 10 m flat ground. Three-dimensional marker trajectories and ground reaction forces (Motion Analysis, USA), and lower limbs’ muscle activities were measured (EMG, Noraxon USA). Knee cartilage and menisci geometries were obtained from subjects’ magnetic resonance images (3T, GE Health Care). An EMG-assisted musculoskeletal finite element modeling workflow was used to estimate knee cartilage tissue mechanics in walking trials. Knee cartilage and menisci were modeled using a transversely isotropic poroviscoelastic material model. Walking speed in SWS, 110%, and 120% of SWS were 1.38 m/s, 1.51 m/s, and 1.65 m/s for the young, and 1.21 m/s, 1.34 m/s and 1.46 m/s for the elderly, respectively. The maximum tensile stress in the elderly tibial cartilage was ~25%, ~33%, and ~32% lower than the young at SWS, 110%, and 120% of SWS, respectively. These preliminary results suggest that the cartilage in the elderly may not have enough stimulation even at 20% increases in walking speed, which may be one reason for tissue degeneration. To enhance these findings, further study with more subjects and different genders will investigate how age-related gait dynamics affects knee biomechanics. Acknowledgments: Australian NHMRC Ideas Grant (APP2001734), KITECH (JE220006)


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 127 - 127
1 Jul 2014
Boyd J Gill H Zavatsky A
Full Access

Summary Statement. Simulated increases in body weight led to increased displacement, von Mises stress, and contact pressure in finite element models of the extended and flexed knee. Contact shifted to locations of typical medial osteoarthritis lesions in the extended knee models. Introduction. Obesity is commonly associated with increased risk of osteoarthritis (OA). The effects of increases in body weight and other loads on the stresses and strains within a joint can be calculated using finite element (FE) models. The specific effects for different individuals can be calculated using subject-specific FE models which take individual geometry and forces into account. Model results can then be used to propose mechanisms by which damage within the joint may initiate. Patients & Methods. Twelve subject-specific FE models (Abaqus 6.11) of three normal healthy subjects were created by combining geometry (3T T1-weighted MRI scans processed using Mimics 13.0, Geomagic Studio 11, and SolidWorks 2010) and load cases (Vicon and AMTI motion analysis data processed within AnyBody Technology Version 3.0 and Matlab R2007a). Model geometry included the femur and tibia (rigid bodies), tibial cartilage and femoral cartilage (E = 12 MPa, ν = 0.45), and menisci (E. circumferential. = 120 MPa, ν. circumferential. = 0.2; E. axial/radial. = 20 MPa, ν. axial/radial. = 0.3). The tibia was held fixed while loads were applied to the centre of mass of the femur. Frictional contact (µ = 0.02) was modelled between soft tissues. Of the twelve models, six were of extended knees and six were of mid-range flexed (∼50°) knees. Each of these six models represented a paired set: a “normal” model and an “increased-load” model. In the flexed knee “increased-load” models, loads were doubled; in the extended knee “increased-load” models, loads were increased to a standard 2000 N compressive load across the joint (approximately three to four times larger than the original loads). Maximum displacements, von Mises stresses, and contact pressures on the articulating tibial cartilage and femoral cartilage surfaces were calculated; results of the “normal” and “increased-load” models were compared. Results. Increasing the applied loads increased the maximum displacements, von Mises stresses, and contact pressures. Contact shifted anteriorly in the extended knee models to typical locations of medial OA cartilage lesions. No contact shift occurred in the flexed knee models; contact remained in typical locations of lateral OA cartilage lesions, but the contact area extended in all directions, and displacements, stresses, and pressures increased. Discussion/Conclusion. Comparing the “normal” and “increased-load” results suggested two potential mechanical mechanisms involved in osteoarthritic cartilage lesion development. Contact shifted to areas of previously-unloaded cartilage in the extended knee “increased-load” models. Cartilage has regional material properties, with stiffer cartilage in areas of frequent contact and loading; shifting contact to areas of less-stiff cartilage could damage the cartilage and lead to degenerative diseases such as OA. Contact did not shift in the flexed knee “increased-load” models. Instead, the displacements, stresses, and pressures increased while the centres of contact remained relatively stationary. If these contact variables increase beyond a threshold magnitude, the cartilage could be damaged, potentially leading to OA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 86 - 86
1 Nov 2018
Paolo SD Wesseling M Pastrama M Van Rossom S Valente G Jonkers I
Full Access

In knee osteoarthritis (OA) patients, a focal cartilage defect is commonly found, especially in the medial compartment. In addition, cartilage softening is often observed at the defect rim. Both factors may alter the loading distribution and thereby the contact pressures, previously related to cartilage degeneration. To determine contact pressure in-vivo during motion, computational modelling can be used. The aim of this study was to analyse knee cartilage pressures during walking in healthy and damaged cartilage using a multi-scale modelling approach. Using 3D motion capture and musculoskeletal models, multi-body simulations of the stance phase of gait calculated knee kinematics and muscle, ligament and contact forces. These were subsequently imposed to a finite element (FE) model including tibial and femoral bones and cartilage. FE analyses were performed using intact cartilage as well as including a medial tibial cartilage defect, with and without softening of the defect rim. Specifically during loading response, a medial cartilage defect reduced the contact surface (−28%) and thereby increased the contact pressure (+33%) compared to intact cartilage, particularly on the medial compartment (+75% in contact pressure). Including softening of the cartilage rim increased the contact area (+22%) and decreased contact pressures (−9%) compared to the defect. This indicates that a focal defect increases the cartilage loading. This is partially compensated by softening of the cartilage rim. Therefore, the role of focal defects in altered cartilage loading and consequent OA development always needs to be discussed acknowledging the cartilage status at the defect rim


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 10 - 10
1 May 2018
Monk P Boyd R Brown C Gibbons M Alvand A Price A
Full Access

The optimal correction of the weight bearing line during High Tibial Osteotomy has not been determined. We used finite element modelling to simulate the effect that increasing opening wedge HTO has on the distribution of stress and pressure through the knee joint during normal gait. Subject-specific models were developed by combining geometry from 7T MRI scans and applied joint loads from ground reaction forces measured during level walking. Baseline stresses and pressures on the articulating proximal tibial cartilage and menisci were calculated. Progressive osteotomies were then simulated to shift the weight-bearing line from the native alignment towards/into the lateral compartment (between 40 – 80% of medial-lateral tibial width). Changes in calculated stresses and pressures were recorded. Both stress and pressure decreased in the medial compartment and increased in the lateral compartment as increasingly valgus osteotomies were simulated. The models demonstrated a consistent “safe zone” for weight bearing line position at 50%-65% medial-lateral tibial width, outside of which compartment stresses and pressures substantial increased. This study suggests a safe correction zone within which a medial opening wedge HTO can be performed correcting the WBL to 55% medio-lateral width of the tibia


Bone & Joint Research
Vol. 11, Issue 10 | Pages 739 - 750
4 Oct 2022
Shu L Abe N Li S Sugita N

Aims

To fully quantify the effect of posterior tibial slope (PTS) angles on joint kinematics and contact mechanics of intact and anterior cruciate ligament-deficient (ACLD) knees during the gait cycle.

Methods

In this controlled laboratory study, we developed an original multiscale subject-specific finite element musculoskeletal framework model and integrated it with the tibiofemoral and patellofemoral joints with high-fidelity joint motion representations, to investigate the effects of 2.5° increases in PTS angles on joint dynamics and contact mechanics during the gait cycle.


Bone & Joint Research
Vol. 13, Issue 1 | Pages 4 - 18
2 Jan 2024
Wang Y Wu Z Yan G Li S Zhang Y Li G Wu C

Aims

cAMP response element binding protein (CREB1) is involved in the progression of osteoarthritis (OA). However, available findings about the role of CREB1 in OA are inconsistent. 666-15 is a potent and selective CREB1 inhibitor, but its role in OA is unclear. This study aimed to investigate the precise role of CREB1 in OA, and whether 666-15 exerts an anti-OA effect.

Methods

CREB1 activity and expression of a disintegrin and metalloproteinase with thrombospondin motifs 4 (ADAMTS4) in cells and tissues were measured by immunoblotting and immunohistochemical (IHC) staining. The effect of 666-15 on chondrocyte viability and apoptosis was examined by cell counting kit-8 (CCK-8) assay, JC-10, and terminal deoxynucleotidyl transferase-mediated dUTP nick end-labelling (TUNEL) staining. The effect of 666-15 on the microstructure of subchondral bone, and the synthesis and catabolism of cartilage, in anterior cruciate ligament transection mice were detected by micro-CT, safranin O and fast green (S/F), immunohistochemical staining, and enzyme-linked immunosorbent assay (ELISA).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 370 - 370
1 Dec 2013
Kessler O
Full Access

INTRODUCTION:. To avoid the early onset of osteoarthritis after partial meniscectomy an effective replacement of injured meniscal tissue would be desirable. The present study investigates the behaviour of a new silk derived scaffold supplied by Orthox Ltd. (Abingdon, UK) in an in vivo sheep model. METHODS:. The scaffolds where derived from silk fibres by processing into an open porous matrix. Nine sheep (4 ± 1 years) underwent partial meniscectomy at the anterior horn of the medial meniscus followed by implantation of a scaffold. The unoperated contralateral stifle joint served as control. After six months the animals were sacrificed and the joints inspected for inflammation. The Young's modulus of the tibial cartilage, meniscus and scaffold was determined by indentation or confined compression tests. All tissues were fixed in formaldehyde for histology. The data were analysed by a Wilcoxon and Mann-Whitney-U-test. RESULTS:. The sheep were free of lameness 4 days p.o. The macroscopic analysis of the genual region and of the synovial membrane showed no signs of inflammation. This was confirmed by histological sections of synovial membrane, meniscus and scaffold. In histology, amorphous material, some fibroblast-like cell clusters and connective tissue formation was visible inside the pores of the scaffold. There were no statistically significant differences between the Young's moduli of the three measuring points in the operated and unoperated stifle joints. The meniscal tissue showed a higher modulus than the scaffolds. The scaffold's modulus significantly increased after three months implantation. DISCUSSION & CONCLUSIONS:. The presented silk scaffold withstood the loads occurring during the six months implantation period. It showed promising properties concerning biocompatibility and cartilage protection and its mechanical properties started to approach those of meniscal tissue


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 54 - 54
1 May 2016
Carpanen D Hillstrom H Walker R Reisse F Cheah K Mootanah R
Full Access

Introduction. Partial meniscectomy, a surgical treatment for meniscal lesions, allows athletes to return to sporting activities within two weeks. However, this increases knee joint shear stress, which is reported to cause osteoarthritis. The volumes and locations of partial meniscectomy that would result in a substantial increase in knee joint stress is not known. This information could inform surgeons when a meniscus reconstruction is required. Aim. Our aim was to use a previously validated knee finite element (FE) model to predict the effects of different volumes and locations of partial meniscectomy on cartilage shear stress. The functional point of interest was at the end of weight acceptance in walking and running, when the knee is subjected to maximum loading. Method. An FE model of the knee joint was used to simulate walking and running, two of the most common functional activities. Forces and moments, obtained from the gait cycle of a 76.4 kg male subject, were applied at the tibia. Different sizes (0%, 10%, 30%, 60%) and locations (anterior, medial and posterior) of partial meniscectomies were simulated (Figure 1). Maximum cartilage shear stress was determined for the different meniscectomies. Graphs were plotted of the cumulative tibial cartilage volume subjected to stress values above specific thresholds. Results and analysis. Maximum shear stress values for the intact knee during walking were 2.00 MPa medially and 1.71 MPa laterally. During running these magnitudes rose to 3.48 MPa medially and 4.70 MPa laterally. For a 30% anterior, central and posterior meniscectomy during walking shear stress increased by 25.9%, 44.9% and 32.5% medially, and 12.4%, 25.7% and 17.8% laterally. During running shear stress increased by 9.6%, 8.3% and 7.1%, medially and 31.6%, 37.5% and 43.6% laterally. For a 60% meniscectomy, during walking shear stress increased by 47.2% medially and 31.8%, laterally. During running shear stress increased by 10.0%, medially and 51.8%, laterally. The percentage of cartilage volume exposed to shear stress levels above a specified threshold is illustrated in Figure 2 for different volumes and locations of partial meniscectomy. Discussion and conclusions. This is first study that has estimated the volume of cartilage exposed to specific stress thresholds in walking and running as a function of the amount and location of meniscectomy. Maximum shear stress was 100% higher at the end of weight acceptance in running compared to walking. Stress was higher in the lateral compartment during running while higher in the medial compartment during walking. This is because a valgus moment acts at the knee at the end of weight acceptance in running while a varus moment acts at the joint in walking. Clinical significance. The model developed from this research has potential for applications in planning meniscal surgeries and developing rehabilitation strategies for athletes. It could inform surgeons about the safe volume and location of partial meniscectomy that can be performed before meniscus reconstruction becomes necessary. Results of this study also highlight the importance of considering the effect of post-surgical outcomes following different common functional activities


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 127 - 127
1 May 2016
Emmanuel K Wirth W Hochreiter J Eckstein F
Full Access

Purpose. It is well known that meniscus extrusion is associated with structural progression of knee OA. However, it is unknown whether medial meniscus extrusion promotes cartilage loss in specific femorotibial subregions, or whether it is associated with a increase in cartilage thickness loss throughout the entire femorotibial compartment. We applied quantitative MRI-based measurements of subregional cartilage thickness (change) and meniscus position, to address the above question in knees with and without radiographic joint space narrowing (JSN). Methods. 60 participants with unilateral medial OARSI JSN grade 1–3, and contralateral knee OARSI JSN grade 0 were drawn from the Osteoarthritis Initiative. Manual segmentation of the medial tibial and weight-bearing medial femoral cartilage was performed, using baseline and 1-year follow-up sagittal double echo steady-state (DESS) MRI, and proprietary software (Chondrometrics GmbH, Ainring, Germany). Segmentation of the entire medial meniscus was performed with the same software, using baseline coronal DESS images. Longitudinal cartilage loss was computed for 5 tibial (central, external, internal, anterior, posterior) and 3 femoral (central, external, internal) subregions. Meniscus position was determined as the % area of the entire meniscus extruding the tibial plateau medially and the distance between the external meniscus border and the tibial cartilage in an image located 4mm posterior to the central image (a location commonly used for semi-quantitative meniscus scoring). The relationship between meniscus position and cartilage loss was assessed using Pearson (r) correlation coefficients, for knees with JSN and without JSN. Results. The percentage of knees showing a quantitative value of >3mm medial meniscus extrusion was 50% in JSN knees, and only 12% in noJSN knees. The 1-year cartilage loss in the medial femorotibial compartment was 74±182µm (2.0%) in JSN knees, and 26±120µm (0.8%) in noJSN knees. There was a significant correlation between cartilage loss throughout the entire femorotibial compartment (MFTC) and extrusion area in JSN knees but not for noJSN knees. Also, the extrusion distance measured 4mm posterior to the central slice was not significantly correlated with MFTC cartilage loss. The strongest (negative) correlation between meniscus position and subregional femorotibial cartilage loss (r=−0.36) was observed for the external medial tibia. In contrast, no significant relationship was seen in the central tibia. No significant relationship was found in other tibial subregions, except for the anterior medial tibia, but only in JSN knees (r=−0.27). Correlation coefficients for the femoral subregions were generally smaller than those for tibial subregions, with only the internal medial weight-bearing femur attaining statistical significance (r =−0.26). Conclusions. The current results show that the relationship between meniscus extrusion and cartilage loss differs substantially between femorotibial subregions. The correlation was strongest for the external medial tibia, a region that is physiologically covered by the medial meniscus. It was less for other tibial and femoral subregions, including the central medial tibia, a region that exhibited similar rates of cartilage loss as the external subregion. The findings suggest that external tibia may be particularly vulnerable to cartilage tissue loss once the meniscus extrudes and the surface is “exposed” to direct, non-physiological, cartilage-cartilage contact


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 117 - 117
1 May 2016
Walker P Chaudhary M Chan H Bosco J
Full Access

INTRODUCTION. The major loss of articular cartilage in medial osteoarthritis occurs in a central band on the distal femur, and in the center of the tibial plateau (Figure). This is consistent with varus deformity due to cartilage loss and meniscal degeneration, together with the sliding regions in walking. Treatment at an early stage such as KL grade 2 or 3, has the advantages of little bone deformity and cruciate preservation, and could be accomplished by resurfacing only the arthritic areas with Early Intervention (EI) components. Such components would need to be geometrically compatible with the surrounding bearing surfaces, to preserve continuity and stability. However because of the relatively small surface area covered, compared with total knees and even unicompartmentals, it is hypothesized that EI components will be an accurate fit on a population of knees with only a small number of sizes, and that accuracy can be maintained without requiring right-left components. We examined this hypothesis using unique design and methodology. METHODS. Average femur and tibia models, including cartilage, were generated from MRI scans of 20 normal males. The images were imported into Geomagic software. Surface point clouds based on least squares algorithms produced the average models. Averages were also produced from different numbers to determine method validity. Average arthritic models were also generated from 12 KL 1–2 cases, and 13 KL 2–3 cases. The 3 averages were compared by deviation mapping. Using the average from the 20 knees, femoral and tibial implant surfaces were designed using contour matching to fit the arthritic regions, maintaining right-left symmetry. A 5 size system was designed corresponding to large male, average male, small male/large female, average female, small female. For the 20 knees, the components were fitted based on the best possible matching of the contours to the surrounding bearing surfaces. For the femoral component the target was 1 mm projection at the center, matching at the ends. The accuracy of reproducing the cartilage surfaces was then determined by mapping the deviations between the implant surfaces and the cartilage surfaces. RESULTS & DISCUSSION. The average femur and tibia from the 20 knees (Figure) was almost identical no matter what groupings were used to produce the average. Likewise the 2 arthritic and the normal averages were almost identical. The accuracy of fit (Figure) averaged for the 20 normal knees was well below 1mm either above or below the original cartilage surfaces (see table below). This study indicates that such Early Intervention components are a viable method for resurfacing cases with early arthritis, and are likely to show almost normal mechanics due to preserving the original normal geometry. Deviations between tibial cartilage and implant (mm). Above implant mean 0.5 SD 0.2. Max deviation 1.5 SD 0.7. Below implant mean 0.7 SD 0.2. Max deviation 2.0 SD 0.1. Deviations between femoral cartilage and implant (mm). Above implant mean 0.3 SD 0.1. Max deviation 0.8 SD 0.1. Below implant mean 0.3 SD 0.1. Max deviation 0.8 SD 0.3


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 1 | Pages 137 - 141
1 Feb 1960
Burger M Sobel AE

The alkaline phosphatase activity of pre-osseous tibial cartilage of rachitic bone stored in the deep freeze for two weeks at -25 degrees centigrade was only slightly less than that of fresh controls from the same animals. The deep frozen pre-osseous tissue did not calcify in in vitro calcifying media containing either inorganic phosphorus or organic phosphate ester. The fresh controls calcified equally well in both media. In addition, after deep-freeze storage the tissue hydrolysed the organic phosphate to the same degree as did the fresh tissue. Bones heated at 65 degrees centigrade will calcify in vitro after calcium chloride treatment despite the destruction of phosphatase activity. It appears unlikely that a relationship exists between alkaline phosphatase and the minimal system required for calcification of pre-osseous cartilage in vitro. These findings do not exclude the possibility that alkaline phosphatase plays some critical role in vivo


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 470 - 470
1 Nov 2011
Fatah EEA Mahfouz MR
Full Access

The success of TKAs depends on the restoration of correct knee alignment and proper implant sizing and placement. The mechanical axis is considered a key factor in the restoration of knee alignment along with the transepicondylar axis and the posterior condylar axis as references for external and internal implant rotation. Accurate calculation of the distal resection plane in the femur and proximal resection plane in the tibia is crucial to determine the amount of the bone to be resected. In this study, we developed a model for mapping the thickness of the femoral and tibial articulating cartilage. We also studied the effect of cartilage presence and the absence on the accuracy of calculating the surgical landmarks, implant sizing and placement. Cartilage models were constructed using fat suppression MRI scans of healthy individuals with different body sizes. The femoral and tibial cartilages were segmented and surface models were generated. The inner and outer surfaces of the cartilage were separated, the inner surfaces were then mapped to the articulating surface of the femur and tibia to establish correspondence between the cortical bone surface and the inner surface of the cartilage. For each vertex on the normalized inner surface of the cartilage, the closest point was found on the outer surface of the cartilage and the normal distances were calculated. These distances were then averaged for each vertex across the population to calculate an average cartilage model. This average cartilage model was then used to grow a cartilage layer on our database of 300 bones from CT scans. Surgical landmarks and implant sizing and placement were then calculated for each bone before and after the cartilage and results were compared. Some of the landmarks including the mechanical and transepicondylar axes were found to be independent from the presence or absence of knee articulating cartilage, whereas the posterior condylar axis and tibial and femoral resection planes can be affected by the absence or presence of cartilage


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 97 - 97
1 Jul 2014
Wen C Wong K Liu C Yan C Lu W Chiu K
Full Access

Summary Statement. OA knee with subchondral cyst formation presented differential microstructure and mechanical competence of trabecular bone. This finding sheds light on the pivot role of subchondral cyst in OA bone pathophysiology. Introduction. Subchondral bone cyst (SBC) is a major radiological finding in knee osteoarthritis (OA), together with joint space narrowing, osteophyte and sclerotic bone formation. There is mounting evidence showing that SBC originates in the same region as bone marrow lesions (BMLs). The presence of subchondral bone cyst (SBCs), in conjunction with BMLs, was associated with the severity of pain, and was able to predict tibial cartilage lolume loss and risk of joint replacement surgery in knee OA patient. It is speculated that the presence of SBCs might increase intraosseous pressure of subchondral bone, and trigger active remodeling and high turnover of surrounding trabecular bone. Yet the exact effect of SBC on the structural and mechanical properties trabecular bone, which provides the support to overlying articular cartilage, remains to be elucidated. Therefore, this study aimed to investiate the microstructure and mechanical competence of trabecular bone of knee OA in presence or absence of SBC. Patients & Methods. A total of 20 postmenopausal women (54–87 years old) with the late-stage of primary knee OA were recruited in this study. Tibial plateau specimens were collected during joint replacement surgery. The samples were grouped for comparison according to presence or absences of SBC in micro-CT images. For micro-CT examination, a cylindrical volume of region of interest (VOI) of 10mm in diameter and 1mm in height was used to cover the trabecular bone region surrounding SBC, and then a cubic VOI of 3.5×3.5×3.5mm. 3. was applied in different anatomic locations of tibial plateau, such as medial, intermediate and lateral part, for the analyses of trabecular bone microstructure. Subsequently, two cylinders of subchondral bone specimens were drilled for each sample with micro-CT guidance from lateral portion of cystic wall along the direction of physiological loading of knee joint. The specimens were processed for micro-CT and mechanical testing using MTS 858 Mini Bionix sequentially. Each specimen was compressed in a longitudinal direction at a speed of 1mm/minute; the ultimate strength and modulus of the specimens were generated. Comparisons of microstructure and mechanical properties of trabecular bone were performed between two groups using student t test. The structure-mechanics relationship was also investigated using Pearson correlation. Results. The bone volume fraction (BV/TV, %) was significantly higher in knee OA specimens in presence of SBC (32±7%) in comparison with those in absence of SBC (16±5%, p<0.001). Meanwhile there were more plate-like trabecular bone surrounding SBC (0.78±0.61) than those without SBC (1.81±0.28, p<0.001), which was indicated by structure model index (0∼3). Furthermore, the trend in conversion of rod-like (close to 3) towards plate-like trabeculae was noticed in different locations of knee OA specimens with SBC formation. Trabecular bone around SBC presented higher modulus (73±22MPa) compared with those without SBC (45±29MPa, p=0.034). The stiffer trabecular bone in presence of SBC correlated with its plate-like morphology (r=0.696, p<0.001) as well as bone volume fraction (r=0.578, p=0.004). Conclusion. Presence of SBC was associated with conversion of trabeculae towards plate-like morphology together with the increase of mechanical competence in advanced knee OA


Bone & Joint Research
Vol. 11, Issue 8 | Pages 518 - 527
17 Aug 2022
Hu W Lin J Wei J Yang Y Fu K Zhu T Zhu H Zheng X

Aims

To evaluate inducing osteoarthritis (OA) by surgical destabilization of the medial meniscus (DMM) in mice with and without a stereomicroscope.

Methods

Based on sample size calculation, 70 male C57BL/6 mice were randomly assigned to three surgery groups: DMM aided by a stereomicroscope; DMM by naked eye; or sham surgery. The group information was blinded to researchers. Mice underwent static weightbearing, von Frey test, and gait analysis at two-week intervals from eight to 16 weeks after surgery. Histological grade of OA was determined with the Osteoarthritis Research Society International (OARSI) scoring system.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 918 - 923
1 Sep 1998
Bruns J Kahrs J Kampen J Behrens P Plitz W

Our aim was to examine the potential of autologous perichondral tissue to form a meniscal replacement. In 18 mature sheep we performed a complete medial meniscectomy. The animals were then divided into two groups: 12 had a meniscal replacement using strips of autologous perichondral tissue explanted from the lower rib (group G) and six (group C) served as a control group without a meniscal replacement. In all animals restriction from weight-bearing was achieved by means of transection and partial resection of tendo Achillis. Six animals (four from group G and two from group C) were each killed at 3, 6 and 12 months. The grafts and the underlying articular cartilage were removed and studied by gross macroscopic examination, light microscopy, SEM, polarised light examination, and by biomechanical tests. In all the transplanted animals a new perichondral meniscus developed. After three months the transplants resembled normal menisci in size and thickness, while in the control animals only small rims of spontaneously grown tissue were seen. Microscopically, the perichondral menisci showed a normal orientation of collagen fibres and normal cellular characteristics, but in the central region, areas of calcification disturbed the regular tissue differentiation. Healing tissue in control animals lacked the normal fibre orientation and cellularity. SEM of perichondral menisci showed surface characteristics similar to those of normal sheep menisci without fissures and lacerations; the control specimens had these defects. The femoral and tibial cartilage in contact with the new menisci had normal surface characteristics apart from one animal with slight surface irregularities. Control animals showed superficial lesions after three months which increased at six to 12 months postoperatively. Microangiography of the newly grown tissue demonstrated a less intense vascularisation after three months when compared with normal menisci. The failure stress and tensile modulus of perichondral menisci were significantly lower than those of normal contralateral menisci, and spontaneously regenerated tissue in meniscectomised animals had even lower values. There were no significant differences in values between newly grown perichondral menisci and spontaneously grown tissue


Bone & Joint Research
Vol. 9, Issue 9 | Pages 593 - 600
1 Sep 2020
Lee J Koh Y Kim PS Kang KW Kwak YH Kang K

Aims

Unicompartmental knee arthroplasty (UKA) has become a popular method of treating knee localized osteoarthritis (OA). Additionally, the posterior cruciate ligament (PCL) is essential to maintaining the physiological kinematics and functions of the knee joint. Considering these factors, the purpose of this study was to investigate the biomechanical effects on PCL-deficient knees in medial UKA.

Methods

Computational simulations of five subject-specific models were performed for intact and PCL-deficient UKA with tibial slopes. Anteroposterior (AP) kinematics and contact stresses of the patellofemoral (PF) joint and the articular cartilage were evaluated under the deep-knee-bend condition.