Global literature suggests that female surgical trainees have lower rates of independent operating (operative autonomy) than their male counterparts. The objective of this study was to identify any association between gender and lead/independent operating in speciality orthopaedic trainees within the UK national training programme. This was a retrospective case-control study using electronic surgical logbook data from 2009 to 2021 for 274 UK orthopaedic trainees. Total operative numbers and level of supervision were compared between male and female trainees, with correction for less than full-time training (LTFT), prior experience, and time out during training (OOP). The primary outcome was the percentage of cases undertaken as lead surgeon (supervised and unsupervised) by UK orthopaedic trainees by gender.Aims
Methods
Symptomatic lumbar spinal stenosis is a common entity and increasing in prevalence. Limited evidence is available regarding patient reported outcomes comparing primary vs revision surgery for those undergoing lumbar decompression, with or without fusion. Evidence available suggest a lower rate of improvement in the revision group. The aim of this study was to assess patient reported outcomes in patients undergoing revision decompression, with or without fusion, when compared to primary surgery. Patient data was collected from the Canadian Spine Outcomes Research Network (CSORN) database. Patients undergoing lumbar decompression without or without fusion were included. Patients under 18, undergoing discectomy, greater than two level decompressions, concomitant cervical or
Resident involvement in the operating room is a vital component of their medical education. Conflicting and limited research exists regarding the effects of surgical resident participation on spine surgery patient outcomes. Our objective was to determine the effect of resident involvement on surgery duration, length of hospital stay and 30-day post-operative complication rates. This study was a multicenter retrospective analysis of the prospectively collected American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database. All anterior cervical or posterior lumbar fusion surgery patients were identified. Patients who had missing trainee involvement information, surgery for cancer, preoperative infection or dirty wound classification, spine fractures, traumatic spinal cord injury, intradural
Introduction.
This study aimed to evaluate rasterstereography of the spine as a diagnostic test for adolescent idiopathic soliosis (AIS), and to compare its results with those obtained using a scoliometer. Adolescents suspected of AIS and scheduled for radiographs were included. Rasterstereographic scoliosis angle (SA), maximal vertebral surface rotation (ROT), and angle of trunk rotation (ATR) with a scoliometer were evaluated. The area under the curve (AUC) from receiver operating characteristic (ROC) plots were used to describe the discriminative ability of the SA, ROT, and ATR for scoliosis, defined as a Cobb angle > 10°. Test characteristics (sensitivity and specificity) were reported for the best threshold identified using the Youden method. AUC of SA, ATR, and ROT were compared using the bootstrap test for two correlated ROC curves method.Aims
Methods
Hemorrhage and transfusion requirements in spine surgery are common. This is especially true for thoracic and lumbar fusion surgeries. The purpose of this papersi to determine predictive factors for transfusion and their effect on short-term post-operative outcomes for thoracic and lumbar fusions. The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database was used to identify patients that underwent lumbar or
Paravertebral anaesthesia is a particularly effective, safe and reliable option in scoliosis patients undergoing anterior release in whom percutaneous epidural placement may be difficult to perform. A recent systematic review and meta-analysis of randomized trials has demonstrated that whilst paravertebral block and thoracic epidural insertion provide comparable pain relief after
Demineralized Bone Matrix (DBM) is currently used in various types of orthopaedic applications because of osteoconductive and osteoinductive properties. Fibrin glue is also used in cardiovascular and
Introduction: Thorascopic techniques are an accepted and useful technique for spinal surgery. For certain clinical indications (i.e. thoracic kyphosis), an anterior spinal release followed by a posterior instrumentation may be indicated. The standard technique for a thorascopic anterior release is with the patient in the lateral decubitus position and intubated with a double lumen endotracheal tube (ETT), allowing one lung to be deflated for access to the spine. Placing a double lumen ETT and repositioning the patient before the posterior surgery both add to the duration of surgery. We report our initial experience using standard ETT ventilation, low pressure CO. 2. insufflation into the thorax to push the lung away from the operative field, and prone positioning, for thorascopic anterior spinal release, followed by posterior instrumentation. Although previously described for
INTRODUCTION: Thorascopic techniques are an accepted and useful technique for spinal surgery. For certain clinical indications (ie thoracic kyphosis), an anterior spinal release followed by a posterior instrumentation may be indicated. The standard technique for a thorascopic anterior release is with the patient in the lateral decubitus position and intubated with a double lumen endotracheal tube (ETT), allowing one lung to be deflated for access to the spine. Placing a double lumen ETT and repositioning the patient before the posterior surgery both add to the duration of surgery. We report our initial experience using standard ETT ventilation, low pressure CO. 2. insufflation into the thorax to push the lung away from the operative field, and prone positioning, for thorascopic anterior spinal release, followed by posterior instrumentation. Although previously described for
The first death in the UK caused by COVID-19 occurred on 5 March 2020. We aim to describe the clinical characteristics and outcomes of major trauma and orthopaedic patients admitted in the early COVID-19 era. A prospective trauma registry was reviewed at a Level 1 Major Trauma Centre. We divided patients into Group A, 40 days prior to 5 March 2020, and into Group B, 40 days after.Aims
Methods
Total joint replacement (TJR) is a high-cost, high-volume procedure that impacts patients’ quality of life. Informed decisions are important for patients facing TJR. The quality of information provided by websites regarding TJR is highly variable. We aimed to measure the quality of TJR information online. We identified 10,800 websites using 18 TJR-related keywords (conditions and procedures) across the Australian, French, German and Spanish Google search engines. We used the Health on the Net (HON) toolbar to evaluate the first 150 websites downloaded for every keyword in each language. The quality of information on websites was inspected, accounting for differences by language and tertiles. We also undertook an analysis of English websites to explore types of website providers.Aims
Methods
Stereotactic navigation in cranial surgery is a well-established technique, in routine clinical use since the turn of the century. The advent of computer guided stereotaxis since the early 1990’s has led to an explosion in applications for the technology in cranial surgery, with the development of new surgical techniques, minimal access and consequent claimed reduction in morbidity and mortality. Computer guidance also allows application of stereotactic techniques in spinal surgery. Early interventions have concentrated on the insertion of pedicle screws with improvement in accuracy and certainty of optimal screw placement. The use of fluoroscopic guidance allows the insertion of percutaneous pedicle screws and truly minimal access fusion techniques for the lumbar spine. More recently the development of improved registration has allowed the application of this technology to
A prospective cohort outcome evaluation of unstable thoracic spine fractures treated with posterior pedicle screw fixation. The purpose of this study was to determine the accuracy of placement and safety of pedicle screws in open reduction of unstable thoracic spine fractures. The surgeries were performed by one of five fellowship trained spinal surgeons. CT scans were formed on twenty-three patients totaling two hundred screws using 3mm cuts. Three independent reviewers assessed and categorized the screw position as within the pedicle or as a violation of the pedicle wall. 98% of the screws were accurate and we recommend the use of pedicle screws in thoracic fractures . A prospective cohort outcome evaluation of unstable thoracic spine fractures treated with posterior pedicle screw fixation. This study is to determine the accuracy of placement, safety of pedicle screws in open reduction of unstable
Adolescent idiopathic scoliosis (AIS) is a complex
3D deformity of the spine. Its prevalence is between 2% and 3% in the
general population, with almost 10% of patients requiring some form
of treatment and up to 0.1% undergoing surgery. The cosmetic aspect
of the deformity is the biggest concern to the patient and is often
accompanied by psychosocial distress. In addition, severe curves
can cause cardiopulmonary distress. With proven benefits from surgery,
the aims of treatment are to improve the cosmetic and functional
outcomes. Obtaining correction in the coronal plane is not the only
important endpoint anymore. With better understanding of spinal
biomechanics and the long-term effects of multiplanar imbalance,
we now know that sagittal balance is equally, if not more, important.
Better correction of deformities has also been facilitated by an
improvement in the design of implants and a better understanding
of metallurgy. Understanding the unique character of each deformity
is important. In addition, using the most appropriate implant and
applying all the principles of correction in a bespoke manner is important
to achieve optimum correction. In this article, we review the current concepts in AIS surgery. Cite this article:
We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity.
Procedures performed at the incorrect anatomical site are commonly perceived as being relatively rare. However, they can be a devastating event for patients and doctors. Evidence from the United Kingdom and North America suggests that wrong-site, wrong-procedure and wrong-patient events occur more commonly than we think. Furthermore, their incidence may be increasing as NHS Trusts increase the volume and complexity of procedures undertaken in order to cope with increasing demands on the system. In previous studies from North America orthopaedic surgery has been found to be the worst-offending specialty. In this paper we review the existing literature on wrong-site surgery and analyse data from the National Patient Safety Agency and NHS Litigation Authority on 292 cases of wrong-site surgery in England and Wales. Orthopaedic surgery accounted for 87 (29.8%) of these cases. In the year 2006 to 2007, the rate of wrong-site surgery in England and Wales was highest in orthopaedic surgery, in which the estimated rate was 1:105 712 cases.