Advertisement for orthosearch.org.uk
Results 1 - 20 of 151
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 17 - 17
1 Jun 2017
Bloch B Shah A Snape S Boswell T James P
Full Access

Infection following total hip or knee arthroplasty is a serious complication. We noted an increase in post-operative infection in cases carried out in a temporary operating theatre. We therefore compared those cases performed in standard and temporary operating theatres and examined the deep periprosthetic infection rates. A total of 1233 primary hip and knee arthroplasties were performed between August 2012 and June 2013. 44% were performed in temporary theatres. The two groups were matched for age, sex, BMI and ASA grade. The deep infection rate for standard operating theatres was 0/684 (0%); for temporary theatres it was 8/539 (1.5%); p=0.001. Use of a temporary operating theatre for primary hip and knee arthroplasty was associated with an unacceptable increase in deep infection. We do not advocate the use of these theatres for primary joint arthroplasty


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 35 - 35
1 May 2018
Thomas A Wijesinghe C Pralyadi R Alberini F Simmons M
Full Access

Introduction. Operating theatre airflow can be measured using pulsed lasers (particle image velocimetry) but the process is difficult to do in 3D. Cup, vane or hot wire anemometers provide only 2D information. 3D measurements enable better understanding of airflow. Patients/Materials & Methods. We used a Windmaster ultrasound 3D anemometer (Skyview systems), which uses three ultrasound transmitters to measure velocity in XYZ planes, with a sampling rate of 32 Hz. Post processing was done using MATLAB. An operating theatre with an Howorth Exflow canopy was studied. Equipment, including lights, was moved. A 50 cm grid was marked, and measurements were made at intervals up to the ceiling. Door opening was observed within the clean zone and the peripheral zone, next to the door and on the opposite side of the room. Anaesthetic screens were studied during operating. Airflow was visualised initially using video of smoke puffs and subsequently measured using the aeronometer. Results. In the upper part of the ultraclean canopy air velocity was 0.34 m/s with a standard deviation of 0.02 m/s, indicating an almost constant velocity. In the periphery there was more turbulence and horizontal air movement. Door opening had no effect on air movements in the clean zone. In the periphery there was an increase in horizontal airflow when the doors are closed. There is a pattern of upward airflow against an anaesthetic screen. This is unlikely to be caused by warming blankets. If the partial wall of the enclosure is lowered this results in a fast washout of air towards the anaesthetist. Discussion. Traditional anaesthetic screens may interfere with airflow. Door opening is a lesser effect. Conclusion. The 3D anemometer enables detailed mapping of airflow within an ultra clean air operating theatre. The data obtained will enable the construction of more accurate computational fluid dynamic models of operating theatres


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 9 - 9
1 Jun 2016
Thomas A Bradley C Fraise A Sherwood G
Full Access

As a result of laser imaging studies in an ultraclean theatre we concluded that obstructions to horizontal airflow at the periphery might produce areas of high particulate residence times. High residence times may allow a higher proportion of infected particles to land. We decided to investigate this effect by placing settle plates in defined positions on instrument trays during surgery. In an initial study contamination was 0.25 colonies/plate/hour. When the surgeon, assistant and scrub person all used a body exhaust system the contamination rate was 0.04 colonies/plate/hour. We then organised the instrument tables with two large tables orientated so that the scrub person did not have to stand between the airflow and the table. We placed plates on both trays with the locations recorded. With the instrument trolleys in optimised positions the contamination rate remained consistently at 0.04 colonies/plate/hour. An animation was produced showing how the bacterial colonies appeared over 18 hours of surgery. The majority of the contamination occurred on the surgeons’ side trolley at the opposite end of the trolley to the surgeon. Ultraclean enclosures in the UK are specified by HTM03-01, which sets a standard of <10 cfu/cubic meter measured by active air sampling. The measurement does not however take place during surgery, as it is very difficult to perform air sampling during surgery. There is a reasonable correlation between air contamination and settle plates so they are a viable method for during surgery monitoring. In a modern operating enclosure, using body exhausts, our contamination rate compares favourably to the fourth phase of Charnley's classic study in which he used 300 air changes/hour in the prototype closure. The rate compares favourably to the multi-centre Italian GISIO-ISChIA study. The contamination rate achieved could form a basis for comparative audits based on realistic during surgery monitoring


Bone & Joint Open
Vol. 5, Issue 9 | Pages 742 - 748
10 Sep 2024
Kodumuri P Joshi P Malek I

Aims. This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Methods. Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries. Results. The carbon footprint of an uncemented THA was estimated at 100.02 kg CO2e, with a marginal increase to 104.89 kg CO2e for hybrid THA. Key contributors were consumables in the operating theatre (21%), waste generation (22%), and scope 2 emissions (38%). The study identified opportunities for reducing emissions, including instrument rationalization, transitioning to LED lighting, and improving waste-recycling practices. Conclusion. This study sheds light on the substantial carbon footprint associated with THA. Actionable strategies for reducing emissions were identified, emphasizing the need for sustainable practices in orthopaedic surgery. The findings prompt a critical discussion on the environmental impact of single-use versus reusable items in the operating theatre, challenging traditional norms to make more environmentally responsible choices. Cite this article: Bone Jt Open 2024;5(9):742–748


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 16 - 16
7 Jun 2023
Thomas A Wilkinson M
Full Access

The documentation of deep infection rates in joint replacement is fraught with multiple difficulties. Deep infections acquired in theatre may present late, but some later presenting deep infections are clearly haematogenous, and not related to surgical management. The effect of Ultra Clean Air on infection rates was published by Charnley in 1972 (CORR,87:167–187). The data is valuable because large numbers of THRs were performed in standard and Ultra Clean theatres, and detailed microbiology of the air was also recorded. No IV antibiotics were used, so only the effect of air quality was studied. We extracted the data on theatre type and numbers from Table 3, and numbers and intervals from surgery of deep infections from Table 7. Theatre types with 300 air changes per hour and 3.5 CFU/M. 3. were classified as Ultra Clean. A logistic regression model was used to examine the effect of theatre type and time elapsed after procedure on the probability of becoming infected. The model suggests that, controlling for time period, Ultra Clean Air is associated with a significantly lower probability of infection, with an OR of 0.30, p = 2.74 × 10. −6. The effect is larger earlier post-surgery, but it does persist. The results are best reviewed as a graphic, which shows that Ultra Clean Air clearly affects the deep infection rate for up to four years post-surgery. Ultra Clean Air reduces infection rates for up to four years post-surgery, so it is safe to assume that infections presenting after this are haematogenous. Ultra Clean Air does not eliminate early deep infection, so some early infections are not related to air quality. It is not practical to undertake widespread detailed retrospective analyses of cases. When monitoring infection rates there needs to be a balance between failing to record infections related to surgical technique and waiting many years to record low numbers of very late presenting problems. We suggest that registries should regard infections documented within three years of surgery as treatment complications. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 10 - 10
7 Jun 2023
Mistry D Ahmed U Aujla R Aslam N D'Alessandro P Malik S
Full Access

Industries such as agriculture, construction and military have stringent rules about hearing protection due to the risk of noise induced hearing loss (NIHL). Due to the use of power tools, orthopaedic staff may be at risk of the same condition. The UK Health and Safety Executive (HSE) have clear standards as to what is deemed acceptable occupational noise levels on an A-weighted and C weighted scale. This review is aimed to assess evidence on noise exposure testing within Orthopaedic theatres to see if it exceeds the HSE regulations. A targeted search of online databases PUBMED and EMBASE was conducted using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) principles. This review was registered prospectively in PROSPERO. An eligibility criterion identifying clinical studies which assessed noise exposure for Orthopaedic staff in theatres were included. Noise exposure data was extracted from these studies and a comparison was made with A weighted and C weighted acceptable exposure levels as quoted in the HSE regulations. Fourteen papers were deemed eligible, which reviewed 133 Orthopaedic operations and 64 Orthopaedic instruments. In total, 61% (81 of 132) of Orthopaedic operations and 70% (45 of 64) of instruments exceeded the noise regulations on an A weighted scale. 22% (10 of 46) of operations exceeded the maximum C weighted peak acceptable noise level. Orthopaedic instruments and operations can exceed safe occupational noise levels. NHS Trusts have clear policies about noise exposure in the workplace but have yet to identify Orthopaedic theatres as a potential at risk area. Orthopaedic staff need education, monitoring and protection whereas Employers and Occupational Health should consider assessments to identify at risk staff in Orthopaedic theatres and offer preventative methods from NIHL


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 189 - 194
1 Feb 2024
Donald N Eniola G Deierl K

Aims. Hip fractures are some of the most common fractures encountered in orthopaedic practice. We aimed to identify whether perioperative hypotension is a predictor of 30-day mortality, and to stratify patient groups that would benefit from closer monitoring and early intervention. While there is literature on intraoperative blood pressure, there are limited studies examining pre- and postoperative blood pressure. Methods. We conducted a prospective observational cohort study over a one-year period from December 2021 to December 2022. Patient demographic details, biochemical results, and haemodynamic observations were taken from electronic medical records. Statistical analysis was conducted with the Cox proportional hazards model, and the effects of independent variables estimated with the Wald statistic. Kaplan-Meier survival curves were estimated with the log-rank test. Results. A total of 528 patients were identified as suitable for inclusion. On multivariate analysis, postoperative hypotension of a systolic blood pressure (SBP) < 90 mmHg two to 24 hours after surgery showed an increased hazard ratio (HR) for 30-day mortality (HR 4.6 (95% confidence interval (CI) 2.3 to 8.9); p < 0.001) and was an independent risk factor accounting for sex (HR 2.7 (95% CI 1.4 to 5.2); p = 0.003), age (HR 1.1 (95% CI 1.0 to 1.1); p = 0.016), American Society of Anesthesiologists grade (HR 2.7 (95% CI 1.5 to 4.6); p < 0.001), time to theatre > 24 hours (HR 2.1 (95% CI 1.1 to 4.2); p = 0.025), and preoperative anaemia (HR 2.3 (95% CI 1.0 to 5.2); p = 0.043). A preoperative SBP of < 120 mmHg was close to achieving significance (HR 1.9 (95% CI 0.99 to 3.6); p = 0.052). Conclusion. Our study is the first to demonstrate that postoperative hypotension within the first 24 hours is an independent risk factor for 30-day mortality after hip fracture surgery. Clinicians should recognize patients who have a SBP of < 90 mmHg in the early postoperative period, and be aware of the increased mortality risk in this specific cohort who may benefit from a closer level of monitoring and early intervention. Cite this article: Bone Joint J 2024;106-B(2):189–194


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 43 - 43
2 May 2024
Martin R Fishley W Kingman A Carluke I Kramer D Partington P Reed M Petheram T
Full Access

Periprosthetic joint infection is a serious complication of primary total hip replacement (THR) with significant associated morbidity. In acute infection, Debridement, Antibiotics and Implant Retention (DAIR) may be considered. Current national guidelines recommend a DAIR should be performed by “an experienced arthroplasty surgeon┕ but do not specify the need for this to be a revision arthroplasty surgeon. We investigated outcomes in our NHS Trust of DAIR procedures performed by revision and non-revision arthroplasty surgeons. Infection registry data and patient records were analysed for all DAIR procedures of infected primary THRs between 2017 and 2021. Data collected included details of the primary surgery, the presentation with infection, the DAIR procedure and any subsequent complications including return to theatre at any time point. Routinely collected pre- and post-operative patient reported outcome measures (PROMs) were reviewed. 54 periprosthetic joint infections of primary THRs received a DAIR procedure. 41 DAIRs were performed by a revision surgeon and 13 by non-revision surgeons. There was no significant difference in time from primary THR to presentation with infection, time from presentation to DAIR or pre-operative C-reactive protein between the two groups. In 21 (38.9%) patients the DAIR procedure was classed as a treatment failure; 17 patients (31.5%) returned to theatre for further revision surgery, one (2.4%) died related to infection and three (5.6%) had persistent infection but did not receive further surgery. Treatment failure was significantly higher in the non-revision surgeon group (9/13 (69.2%)) than in the revision surgeon group (12/41 (29.3%)) (p = 0.02). Overall, improvement in PROMs after DAIR was seen at both six and 12 months. The overall success rate of DAIR was 61.1% and there was a sustained improvement in PROMs after surgery. However, there was a significant difference in failure rates between revision surgeons and non-revision surgeons


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1017 - 1026
1 Dec 2021
Sadiq S Lipski C Hanif U Arshad F Chaudary M Chaudhry F

Aims. This study assessed the impact of COVID-19 on hip and distal femur fracture patient outcomes across three successive UK lockdown periods over one year. Methods. A single-centre retrospective cohort study was performed at an acute NHS Trust. Hip and distal femur fracture patients admitted within the first month from each of the three starting dates of each national lockdown were included and compared to a control group in March 2019. Data were collected as per the best practice tariff outcomes including additional outcomes as required. Data collection included COVID-19 status, time to theatre, 30-day mortality, presence of acute kidney injury (AKI) and pneumonia, and do not attempt cardiopulmonary resuscitation (DNACPR) status. Data were analyzed using an independent-samples t-test or chi-squared test with Fisher’s exact test where applicable. A p-value of < 0.05 was considered statistically significant. Results. A total of 95 patients during the pandemic were included and 20 were COVID-positive. Patients experienced a statistically significant increase in time to theatre in Lockdown 1 compared to 2019 (p = 0.039) with a decrease with successive lockdown periods by Lockdown 3. The 30-day mortality increased from 8.8% in 2019 to 10.0% to 14.8% in all lockdown periods. COVID-positive patient mortality was 30.0% (p = 0.063, odds ratio (OR) = 4.43 vs 2019). The rates of AKI and pneumonia experienced were higher for patients during the pandemic. The highest rates were experienced in COVID-positive patients, with 45.0% of patients with AKI versus 27.0% in 2019 (p = 0.38, OR = 1.80), and 50.0% of patients diagnosed with pneumonia versus 16.2% in 2019 (p = 0.0012, OR = 5.17). The percentage of patients with a DNACPR increased from 30.0% in 2019 to 60.7% by Lockdown 3 (p = 0.034, OR = 3.61). Conclusion. COVID-positive hip and distal femur fracture patients are at a higher risk of mortality due to AKI and pneumonia. Patient outcomes have improved with successive lockdowns to pre-pandemic levels. Cite this article: Bone Jt Open 2021;2(12):1017–1026


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 40 - 40
7 Jun 2023
Edwards T Soussi D Gupta S Khan S Patel A Patil A Badri D Liddle A Cobb J Logishetty K
Full Access

Superior teamwork in the operating theatre is associated with improved technical performance and clinical outcomes. Yet modern rota patterns, workforce shortages, and increasing complexity of surgery, means that there is less familiarity between staff and the required choreography. Immersive Virtual Reality (iVR) can successfully train surgical staff individually, however iVR team training has yet to be investigated. We aimed to design a multiplayer iVR platform for anterior approach total hip arthroplasty (AA-THA) and assess if multiplayer iVR training was superior to single player training for acquisition of both technical and non-technical skills. An iVR platform with choreographed roles for the surgeon and scrub nurse was developed using Cognitive Task Analysis. Forty participants were randomised to individual or team iVR training. Individually- trained participants practiced alongside virtual avatar counterparts, whilst teams trained live in pairs. Both groups underwent five iVR training sessions over 6-weeks. Subsequently, they underwent a real-life assessment in which they performed AA-THA on a high-fidelity model with real equipment in a simulated theatre. Teams performed together and individually trained participants were randomly paired up. Videos were marked by two blinded assessors recording the NOTSS, NOTECHS II and SPLINTS scores - validated technical and non-technical scores assessing surgeon and scrub nurse skills. Secondary outcomes were procedure time and number of technical errors. Teams outperformed individually trained participants for non-technical skills in the real-world assessment (NOTSS 13.1 ± 1.5 vs 10.6 ± 1.6, p =0.002, NOTECHS-II score 51.7 ± 5.5 vs 42.3 ± 5.6, p=0.001 and SPLINTS 10 ± 1.2 vs 7.9 ± 1.6, p = 0.004). They completed the assessment 28.1% faster (27.2 minutes ± 5.5 vs 41.8 ±8.9, p<0.001), and made fewer than half the number of technical errors (10.4 ± 6.1 vs 22.6 ± 5.4, p<0.001). Multiplayer training leads to faster surgery with fewer technical errors and the development of superior non-technical skills for anterior approach total hip arthroplasty. The convention of surgeons and nurses training separately, but undertaking real complex surgery together, can be supplanted by team training, delivered through immersive virtual reality


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 27 - 27
1 Apr 2022
Evans J Inman D Johansen A
Full Access

The National Hip Fracture Database (NHFD) started collecting data on peri-prosthetic femoral fractures (PPFF) in December 2019. We reviewed the data from the first year of data collection to describe the patients being admitted with PPFF and the care they received according to established Key Performance Indicators (KPIs) used in hip fracture surgery. We performed a retrospective review of the NHFD between 1 January and 31 December 2020. Analyses consisted of the summary statistics used to generate the NHFD annual report. Of the KPIs used in hip fracture, data were available for PPFF on time to assessment by a geriatrician (KPI 1), time to theatre (if applicable) (KPI 2), and mobilisation the day after surgery (if applicable) (KPI 4). There were 2,411 PPFF fractures around a hip or knee replacement reported out of a total of 2,606 PPFF. Of the 171 hospitals reporting data to the NHFD, 135 reported at least one. The median number of fractures per hospital was 14 (IQR 8, 25, range 1 to 110). The median age of patients was 84 (range 60 to 104) and 1,604 (67%) patients were female. Of the 1,850 occasions a time to geriatrician review was documented, review within 72 hours was achieved on 89.2% of occasions. Of the 1,973 patients who underwent operative interventions, 546 patients went to theatre before the 36-hour target (28.4%). Of patients who had surgery 1,323 (67.4%) were mobilised the following day. In the first year collecting data on PPFF we can give the first idea of the incidence of these life changing injuries. Whilst geriatrician review with 72 hours was achieved in a high proportion of cases nationally, our data suggest fewer patients are mobilised the day after surgery. Notably, only 28.4% of patients who were managed operatively went to theatre within 36 hours of admission. We provide the first insight into the incidence and management of these injuries


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 20 - 20
1 Aug 2021
Palmer J Fraig H Wilson C Garrett S
Full Access

Noise induced hearing loss (NIHL) is a common cause of preventable deafness in adults and exposure to loud noise at work is a significant risk factor for its development. In order to protect the hearing of workers in the U.K., the Health and Safety Executive (HSE), on behalf of the Department for Work and Pensions, established the Control of Noise at Work Regulations (2005). The objectives of this study were to define the levels of noise exposure for the surgeon, assistant, scrub nurse and anaesthetist during total hip and knee arthroplasty surgery. In addition, we sought to determine whether the noise exposure during these procedures reaches or exceeds the action values set out by the U.K. Noise at Work Regulations (2005). To our knowledge no real-time assessment of personal noise exposure has been performed simultaneously on multiple members of the theatre team during arthroplasty surgery. Individual noise exposure during arthroplasty hip and knee surgery was recorded using a personal noise dosemeter system model 22 (DM22) (Pulsar instruments, Filey, U.K.). Recordings were taken real-time during five separate theatre sessions. Each theatre session included two arthroplasty procedures and lasted approximately 4hrs. Personal noise exposure was expressed in terms of peak sound pressure and an average noise exposure over an 8-hour time-period to reflect the noise experienced by the ear over a working day. In all three sessions involving total hip replacement surgery the peak sound pressure, for the operating surgeon, exceeded the exposure action values set out by the U.K. Noise at Work Regulations. Theatre sessions involving total knee replacement surgery did not exceed any exposure action values. The peak sound pressures experienced during total hip replacement surgery are too high and mandate that the surgeon should be provided with appropriate hearing protection. In addition, if the upper exposure action value is routinely exceeded then the theatre should be designated a hearing protection zone


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 20 - 20
1 Apr 2022
Afzal S Hodhody G Kennedy J Board T
Full Access

Total Hip Replacements (THR) and Hip Hemiarthroplasties (HA) are both successful and common orthopaedic procedures. Dislocation is a well-recognised complication carrying significant morbidity and, in some cases, increased mortality risks. We define prosthetic hip dislocations (PHDs) to include both THRs and HAs. Prosthetic Hip Dislocations (PHDs) are a common acute admission yet there are no published guidelines or consensus on management following reduction. A retrospective audit was undertaken by the North West Orthopaedic Research Collaborative (NWORC) between January 2019 and July 2019. A questionnaire was used to capture the management of each dislocation episode presenting to 11 Hospital trusts. The study was registered as a Quality Improvement (QI) project at each site. Data regarding the surgical management physiotherapy input, ongoing care and further management plans were recorded. A total of 183 patients with 229 dislocations were submitted for initial analysis (171 THRs, 10 HAs, 2 PFRs). Female to male ratio was 2:1 with mean age of 76.7 years. Average time to first dislocation was 8.1 years. 61.1% were first or second time dislocators and 38.9% presented with 3 or more dislocations. Initial reductions were predominantly attempted in theatre (96.5%, n=221) with only 3.5% (n=8) attempted in the emergency department. In theatre 89% (n=201) were reduced closed. There was no plan for revision surgery in 70.6% cases with no difference seen between patients with >=3 dislocations and <=2 dislocations. Of the patients with a revision plan, 71% of these were performed or planned locally. The high number of patients with 3 or more dislocations and the lack of plans for definitive interventions in the majority of cases highlights the significant variation in the management of this complex group of patients. This variation in the quality of care increases the burden on the National Health Service through repeat hospital episodes. We aim to roll out this study nationally to assess regional variations and ultimately make the case for national guidance on the management of prosthetic hip dislocations


Bone & Joint Open
Vol. 1, Issue 9 | Pages 530 - 540
4 Sep 2020
Arafa M Nesar S Abu-Jabeh H Jayme MOR Kalairajah Y

Aims. The coronavirus disease (COVID)-19 pandemic forced an unprecedented period of challenge to the NHS in the UK where hip fractures in the elderly population are a major public health concern. There are approximately 76,000 hip fractures in the UK each year which make up a substantial proportion of the trauma workload of an average orthopaedic unit. This study aims to assess the impact of the COVID-19 pandemic on hip fracture care service and the emerging lessons to withstand any future outbreaks. Methods. Data were collected retrospectively on 157 hip fractures admitted from March to May 2019 and 2020. The 2020 group was further subdivided into COVID-positive and COVID-negative. Data including the four-hour target, timing to imaging, hours to operation, anaesthetic and operative details, intraoperative complications, postoperative reviews, COVID status, Key Performance Indicators (KPIs), length of stay, postoperative complications, and the 30-day mortality were compiled from computer records and our local National Hip Fracture Database (NHFD) export data. Results. Hip fractures and inpatient falls significantly increased by 61.7% and 7.2% respectively in the 2020 group. A significant difference was found among the three groups regarding anaesthetic preparation time, anaesthetic time, and recovery time. The mortality rate in the 2020 COVID-positive group (36.8%) was significantly higher than both the 2020 COVID-negative and 2019 groups (11.5% and 11.7% respectively). The hospital stay was significantly higher in the COVID-positive group (mean of 24.21 days (SD 19.29)). Conclusion. COVID-19 has had notable effects on the hip fracture care service: hip fracture rates increased significantly. There were inefficiencies in theatre processes for which we have recommended the use of alternate theatres. COVID-19 infection increased the 30-day mortality and hospital stay in hip fractures. More research needs to be done to reduce this risk. Cite this article: Bone Joint Open 2020;1-9:530–540


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 321 - 328
1 Feb 2021
Vandeputte F Vanbiervliet J Sarac C Driesen R Corten K

Aims. Optimal exposure through the direct anterior approach (DAA) for total hip arthroplasty (THA) conducted on a regular operating theatre table is achieved with a standardized capsular releasing sequence in which the anterior capsule can be preserved or resected. We hypothesized that clinical outcomes and implant positioning would not be different in case a capsular sparing (CS) technique would be compared to capsular resection (CR). Methods. In this prospective trial, 219 hips in 190 patients were randomized to either the CS (n = 104) or CR (n = 115) cohort. In the CS cohort, a medial based anterior flap was created and sutured back in place at the end of the procedure. The anterior capsule was resected in the CR cohort. Primary outcome was defined as the difference in patient-reported outcome measures (PROMs) after one year. PROMs (Harris Hip Score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), and Short Form 36 Item Health Survey (SF-36)) were collected preoperatively and one year postoperatively. Radiological parameters were analyzed to assess implant positioning and implant ingrowth. Adverse events were monitored. Results. At one year, there was no difference in HSS (p = 0.728), HOOS (Activity Daily Life, p = 0.347; Pain, p = 0.982; Quality of Life, p = 0.653; Sport, p = 0.994; Symptom, p = 0.459), or SF-36 (p = 0.338). Acetabular component inclination (p = 0.276) and anteversion (p = 0.392) as well as femoral component alignment (p = 0.351) were similar in both groups. There were no dislocations, readmissions, or reoperations in either group. The incidence of psoas tendinitis was six cases in the CS cohort (6%) and six cases in the CR cohort (5%) (p = 0.631). Conclusion. No clinical differences were found between resection or preservation of the anterior capsule when performing a primary THA through the DAA on a regular theatre table. In case of limited visibility during the learning curve, it might be advisable to resect a part of the anterior capsule. Cite this article: Bone Joint J 2021;103-B(2):321–328


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 3 - 3
1 Apr 2022
Jain S Menon D Sheikh S Bennett D Mitchell T Kerr J Bassi V Pandit H
Full Access

Periprosthetic femoral fracture (PFF) incidence following hip replacement surgery continues to rise. There is a national drive to centralise PFF treatment within specialist centres to improve clinical outcomes and cost-effectiveness. The financial implications of treating PFFs must be analysed to guide allocation of funding. Data were collected for 129 PFFs admitted from 02/04/2014–19/05/2020. Financial data were provided by the Patient Level Information and Costing Systems (PLICS) team. Primary outcomes were cost, revenue and margin for each PFF. Additional data were collected on length of stay (LOS), critical care requirements and clinical outcomes. Statistical comparisons were made between treatment type (fixation vs revision). Significance was set to p<0.05. Across the entire cohort, total cost was £2,389,901, total revenue was £1,695,435 and total loss was £694,481. Highest costs were ward stay (£714,591), theatre utilisation (£382,625), and overheads (£249,110). Median cost was £15,863 (IQR, £11,092-£22,221), median revenue was £11,305 (IQR, £7,147-£15,222) and median loss was £3,795 (IQR, £605-£8687). Median LOS was 21 days (IQR 13–34) and 28.7% patients required critical care admission. Ninety-six patients were treated operatively with either fixation (n=53) or revision (n=43). Median operating time was lower for fixation versus revision (132 [IQR, 115–185] vs 201 [IQR, 159–229] minutes, p=0.001). Median cost (£17,455 [IQR, £13,095-£22,824] vs £17,399 [£13,394-£23,404]) and median loss (£5,774 [IQR, £2,092-£10,472] vs £3,860 [IQR, £96-£7,601]) were similar for fixation and revision (p=0.99 and p=0.18, respectively). Median revenue was greater for revision versus fixation (£13,925 [IQR, £11,294-£17,037] vs £12,160 [IQR, £8,486-£14,390], p=0.02). There was no difference in LOS (21 [13–34] vs 21 [14–30] days, p=0.94), critical care requirements (20 [37.7%] vs 11 [25.6%], p=0.30), reoperations (3 [5.7%] vs 6 [14.0%], p=0.29], local complications (8 [15.1%) vs 12 [27.9%], p=0.20) or systemic complications (11 [20.8%] vs 11 [25.6%], p=0.75) between fixation and revision. PFF treatment costs are high with inadequate reimbursement through tariff. Work is needed to address this disparity and reduce costs associated with LOS, theatre utilisation and implants. Treatment cost should not be used when deciding between fixation and revision surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 54 - 54
2 May 2024
Potter M Uzoigwe C Azhar S Symes T
Full Access

Following the establishment of regional Major Trauma Networks in England in 2012, there were concerns that pressures regarding resource allocation in Major Trauma Centres (MTCs) may have a detrimental impact on the care of patients with hip fractures in these hospitals. This study aimed to compare outcomes in hip fracture care between MTCs and trauma units (TUs). National Hip Fracture Database data was extracted from 01/01/2015 to 31/12/2022 for all hospitals in England. Outcome measures included perioperative medical and physiotherapy assessments, time to surgery, consultant supervision in theatre, Best Practice Tariff (BPT) compliance, discharge to original residence, and mortality. Data was pooled and weighted for MTCs and remaining hospitals (TUs). A total of 487,089 patients with hip fractures were included from 167 hospitals (23 MTCs and 144 TUs). MTCs achieved marginally higher rates of orthogeriatrician assessment within 72 hours of admission (91.1% vs 90.4%, p<0.001) and mobilisation out of bed by first postoperative day (81.9% vs 79.7%, p<0.001). A lower proportion of patients underwent surgery by the day after admission in MTCs (65.2% vs 69.7%, p<0.001). However, there was significantly higher consultant surgeon and anaesthetist supervision rates during surgery in MTCs (71.8% vs 61.6%, p<0.001). There was poorer compliance with BPT criteria in MTCs (57.3% vs 60.4%, p<0.001), and proportionately fewer MTC patients were discharged to their original residence (63.5% vs 60.4%, p<0.001). There was no difference between MTCs and TUs in 30-day mortality (6.8% vs 6.8%, p=0.825). This study demonstrates that MTCs have greater difficulty in providing prompt surgery to hip fracture patients. However, their marginally superior perioperative care outcomes appear to compensate for this, as their mortality rates are similar to TUs. These findings suggest that the regionalisation of major trauma in England has not significantly compromised the overall care of hip fracture patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 5 - 5
7 Jun 2023
Prakash R Abid H Wasim A Sharma A Agrawal Y
Full Access

The National Health Service produces over 500,000 tonnes of waste and 25 mega tonnes of CO2 annually. Operating room waste is segregated into different streams which are recycled, disposed of in landfill sites, or undergo costly and energy-intensive incineration processes. By assessing the quantity and recyclability of waste from primary hip and knee arthroplasty cases, we aim to identify strategies to reduce the carbon footprint of arthroplasty surgery. Data was collected prospectively at a tertiary orthopaedic hospital, in the theatres of six arthroplasty surgeons between April – July 2022. Fifteen primary total hip arthroplasty (THA) and 16 primary total knee arthroplasty (TKA) cases were included; revision and complex primary cases were excluded. Waste was categorised into non-hazardous waste, hazardous waste, recycling, sharps, and linens. Each waste category was weighed. Items disposed as non-hazardous waste were catalogued for a sample of 10 TKA and 10 THA cases. Recyclability of items was determined from packaging. Average total waste generated for THA and TKA were 14.46kg and 17.16kg respectively, with TKA generating significantly greater waste (p < 0.05). On average only 5.4% of waste was recycled in TKA and just 2.9% in THA cases. The mean recycled waste was significantly greater in TKA cases compared to THA, 0.93kg and 0.42kg respectively (p < 0.05). Hazardous waste represented the largest proportion of the waste streams for both TKA (69.2%) and THA (73.4%). On average TKA generated a significantly greater amount (11.87kg) compared to THA (10.61kg), p < 0.05. Non-hazardous waste made up 15.1% and 11.3% of total waste for TKA and THA respectively. In the non-hazardous waste, only two items (scrub brush packaging and sterile towel packaging) were identified as recyclable based on packaging. We estimate that annually total hip and knee arthroplasty generates over 2.7 million kg of waste in the UK. Through increased use of recyclable plastics for packaging, combined with clear labelling of items as recyclable, medical suppliers can significantly reduce the carbon footprint of arthroplasty. Our data highlight only a very small percentage of waste is recycled in total hip and knee arthroplasty cases


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 49 - 49
19 Aug 2024
Beverland D Wong ML Robinson M Cassidy R Lamb J Diamond O
Full Access

A: - determine the incidence of intraoperative periprosthetic femoral fracture (PFF). B: - determine the incidence of, and the reoperation rate for postoperative PFF. When using either CC or PTS femoral components. Retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All PFFs were identified using regional radiograph archiving and electronic care systems. Of the 11,018 THAs 4,952 were CC and 6,066 were PTS. Between groups, age, sex, and BMI did not differ. A: - 55 (0.5%) had an intraoperative PFF. 44 CC and 11 PTS (p<0.001). 3 patients in each group had a femoral shaft fracture, remaining fractures were either the calcar (20 CC and 2 group) or the greater trochanter (11 CC and 6 PTS). B: - 91(0.8%) sustained a postoperative PFF. Of those 15 were managed conservatively, 15 were revised and 61 (80.3%) had an ORIF. The CC group had both a lower overall rate of postoperative PFFs (0.7% (36/4,952) vs 0.9% (55/6,066); p = 0.341), and a lower rate of return to theatre (0.4% (22/4,952) vs 0.9% (54/6,066); p = 0.005). 1.3% of male PTS (36/2,674) had a reoperation compared to 0.3% of male CC (7/2,121) (p<0.001). With regard to stem fracture there were none in the Corail group and 5 in the Exeter group. Of these 2 were sub trunnion and 3 were basal neck. A: - There were significantly more intraoperative PFFs with CC 44 (0.8%) than PTS 11 (0.2%). However, the majority of fractures were either of the calcar or greater trochanter with no impact on early recovery or one year Oxford scores. B: - Male PTS were five times more likely to have a reoperation for postoperative PFF. Females had the same incidence of reoperation with either component type. There were 5 stem fractures in the Exeter group and none in the Corail. These results represent robust estimates, which are likely to be more accurate than revision only studies typically generated from registry data


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 11 - 11
1 Aug 2021
Lukic J Rajeev A Tyas B Singisetti K
Full Access

Hip fractures in elderly patients are managed at both major trauma centers (MTC) and trauma units (TU). Previous evidence has demonstrated the importance of early surgery to reduce the morbidity and mortality related to the injury. The aim of this study is to compare the ‘time to theatre' and ‘30 day mortality' in TUs versus MTC in UK. A retrospective review of prospectively collected data on NHFD was performed. The average ‘time to theatre' in hours and ‘30 day mortality' of all hospitals were analysed between January and December 2018. Further subgroup analysis was done to check for any regional variations; in each instance a Shapiro-Wilk test was used to check for normal distribution, followed by a one-way ANOVA with a Tukey's post hoc test. Data from 158 hospitals in England (ENG), Wales (WAL) and Northern Ireland (NI) were used; 18 of which were MTC. There were 57,936 operative cases in TUs and 8606 in MTC's. The mean time (hours) to surgery from presentation was 32.51 and 32.64 for TUs and MTC respectively (p=0.513). There was no significant difference in ‘30 day mortality' (p=0.635) between TUs (6%) and 5.7% MTC's (5.7%), MTC's and TUs in ENG, WAL and NI (p=0.555), and MTC and WAL, NI and the different regions of ENG (p=0.209). A significant difference was observed, between the regional practice for TUs versus MTC's in ENG, WAL and NI (p=0.001) and between MTC's and TUs in WAL, NI and the different regions of ENG (p=0.001), with patients waiting significantly longer in NI for their procedure (mean=60.25 hours, p=0.001). There was no significant difference in time to surgery or 30 day mortality between TUs and MTC's, demonstrating comparable hip fracture care, despite MTCs need to prioritise more serious injuries