Advertisement for orthosearch.org.uk
Results 1 - 20 of 21
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 45 - 45
1 Nov 2018
Sheehy E von Deimling C Moriarty SKF O'Brien F
Full Access

Chronic osteomyelitis (OM) is a progressive, inflammatory infection of bone caused predominantly by S. aureus and requires treatment through surgical debridement and systemic antibiotic administration. We have previously reported the fabrication of an antibiotic-eluting scaffold which is responsive to microbial activity for the treatment of OM. Herein, we ventured to assess the capacity of this antibiotic-eluting scaffold to treat infection in a rabbit model of chronic OM. Infections were established in the radii of New Zealand White rabbits using inoculations of 2×10. 6. CFUs S. aureus JAR 060131 over a period of 4 weeks. Following surgical debridement (6mm), rabbits underwent treatment for a period of 8 weeks until euthanasia. The treatment groups were; 1) empty, 2) antibiotic-eluting scaffold (collagen/hydroxyapatite scaffold loaded with vancomycin) and 3) commercially available antibiotic-eluting fleece (Septocoll E®, collagen fleece loaded with gentamicin). During the treatment period, all groups received systemic antibiotics (Cefazolin 25mg/kg) administered subcutaneously twice daily for 4 weeks. Inoculation of the radius resulted in the development of a sequestrum containing S. aureus, demonstrating the successful establishment of OM. After the 8-week treatment period, 4/5 rabbits in the empty group were still infected, indicating that systemic antibiotic administration following debridement was insufficient to treat the infection. Fewer rabbits in both the antibiotic-eluting scaffold group (2/4) and the antibiotic-eluting fleece group (1/3) were infected. This work demonstrates that the implantation of an antibiotic-eluting biomaterial into a defect following debridement enhances bacterial clearance in conditions of chronic OM


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 36 - 36
11 Apr 2023
Boyce S Le Maitre C Smith T Nichol T
Full Access

An increasing elderly population means joint replacement surgery numbers are projected to increase, with associated complications such as periprosthetic joint infections (PJI) also rising. PJI are particularly challenging due to antimicrobial resistant biofilm development on implant surfaces and surrounding tissues, with treatment typically involving invasive surgeries and systemic antibiotic delivery. Consequently, functionalisation of implant surfaces to prevent biofilm formation is a major research focus. This study characterises clinically relevant antimicrobials including gentamicin, clindamycin, daptomycin, vancomycin and caspofungin within a silica-based, biodegradable sol-gel coating for prosthetic devices. Antimicrobial activity of the coatings against clinically relevant microorganisms was assessed via disc diffusion assays, broth microdilution culture methods and the MBEC assay used to determine anti-biofilm activity. Human and bovine cells were cultured in presence of antimicrobial sol-gel to determine cytotoxicity using Alamar blue and antibiotic release was measured by LC-MS. Biodegradability in physiological conditions was assayed by FT-IR, ICP-MS and measuring mass change. Effect of degradation products on osteogenesis were studied by culturing mesenchymal stem cells in the presence of media in which sol-gel samples had been immersed. Antimicrobial-loaded coatings showed strong activity against a wide range of clinically relevant bacterial and fungal pathogens with no loss of activity from antibiotic alone. The sol-gel coating demonstrated controlled release of antimicrobials and initial sol-gel coatings showed no loss of viability on MSCs with gentamicin containing coatings. Current work is underway investigating cytotoxicity of sol-gel compositions against MG-63 cells and primary osteoblasts. This research forms part of an extended study into a promising antimicrobial delivery strategy to prevent PJI. The implant coating has potential to advance PJI infection prevention, reducing future burden upon healthcare costs and patient wellbeing


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 59 - 59
11 Apr 2023
Chitto M Chen B Kunisch F Wychowaniec J Onsea J Post V Richards G Zeiter S Wagemans J Trampuz A D'Este M Moreno M Lavigne R Moriarty F
Full Access

Fracture related infection remains a major challenge in musculoskeletal trauma surgery. Despite best practice, treatment strategies suffer from high failure rates due to antibiotic resistance and tolerance. Bacteriophages represent a promising alternative as they retain activity against such bacteria. However, optimal phage administration protocols remain unknown, although injectable hydrogels, loaded with phage and conventional antibiotics, may support conventional therapy. In this study we tested the activity of meropenem, and two newly isolated bacteriophages (ϕ9 and ϕ3) embedded within alginate-chitosan microbeads and a hydrogel. Antibiotic and phage stability and activity were monitored in vitro, over a period of 10 days. In vivo, the same material was tested in treatment of a 5-day old Pseudomonas aeruginosa infection of a tibial plate osteotomy in mice. Treatment involved debridement and 5 days of systemic antibiotic therapy plus: i- saline, ii-phages in saline, iii-phages and antibiotics loaded into a hydrogel (n=7 mice/group). To assess the efficacy of the treatments, the infection load was monitored during revision surgery with debridement of the infected tissue after 5,10 and 13 days (euthanasia) by CFU and PFU quantification. In vitro testing confirmed that the stability of meropenem and activity of ϕ9 and ϕ3, was not affected within the alginate beads or hydrogel over 10 days. The in vivo study showed that all mice receiving phages and antibiotics loaded into a hydrogel survived the infection with a reduction of the bacterial load in the soft tissue. Active phages could be recovered from the infected site at euthanasia (10. 4. PFU/g). The hydrogel loaded with bacteriophages and meropenem showed a positive result in locally reducing the infection load indicating a synergistic effect of the selected antimicrobials. Overall, our new strategy shows encouraging results for improving the treatment of antibiotic-resistant biofilm infections that are related to medical implants


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 8 - 8
17 Apr 2023
Buchholz T Zeiter S Moriarty T Awad H Nehrbass D Constant C Elsayed S Yan M Allen M
Full Access

Treatment of bone infection often includes a burdensome two-stage revision. After debridement, contaminated implants are removed and replaced with a non-absorbable cement spacer loaded with antibiotics. Weeks later, the spacer is exchanged with a bone graft aiding bone healing. However, even with this two-stage approach infection persists. In this study, we investigated whether a novel 3D-printed, antibiotic-loaded, osteoinductive calcium phosphate scaffold (CPS) is effective in single-stage revision of an infected non-union with segmental bone loss in rabbits. A 5 mm defect was created in the radius of female New Zealand White rabbits. The bone fragment was replaced, stabilized with cerclage wire and inoculated with Staphylococcus aureus (MSSA). After 4 weeks, the infected bone fragment was removed, the site debrided and a spacer implanted. Depending on group allocation, rabbits received: 1) PMMA spacer with gentamycin; 2) CPS loaded with rifampin and vancomycin and 3) Non-loaded CPS. These groups received systemic cefazolin for 4 weeks after revision. Group 4 received a loaded CPS without any adjunctive systemic therapy (n=12 group1-3, n=11 group 4). All animals were euthanized 8 weeks after revision and assessed by quantitative bacteriology or histology. Covariance analysis (ANCOVA) and multiple regression were performed. All animals were culture positive at revision surgery. Half of the animals in all groups had eliminated the infection by end of study. In a historical control group with empty defect and no systemic antibiotic treatment, all animals were infected at euthanasia. There was no significant difference in CFU counts between groups at euthanasia. Our results show that treating an osteomyelitis with segmental bone loss either with CPS or PMMA has a similar cure rate of infection. However, by not requiring a second surgery, the use of CPS may offer advantages over non-resorbable equivalents such as PMMA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 61 - 61
17 Apr 2023
Lodewijks L Blokhuis T Poeze M
Full Access

The need for an artificial scaffold in very large bone defects is clear, not only to limit the risk of graft harvesting, but also to improve clinical success. The use of custom osteoconductive scaffolds made from biodegradable polyester and ceramics can be a valuable patient friendly option, especially in case of a concomitant infection. Multiple types of scaffolds for the Masquelet procedure (MP) are available, however these frequently demonstrate central graft involution when defects exceed a certain size and the complication rates remains high. This paper describes three infected tibial defect nonunions with a segmental defect over ten centimeters long treated with a customized 3D printed polycaprolactone-tricalcium phosphate (PCL-TCP) cage in combination with biological adjuncts. Three male patients, between the age of 37 and 47, were treated for an infected tibial defect nonunion after sustaining Gustilo grade 3 open fractures. All had a segmental midshaft bone defect of more than ten centimeters (range 11–15cm). First stage MPs consisted of extensive debridement, external fixation and placement of anterior lateral thigh flaps (ALT). Positive cultures were obtained from all patients during this first stage, that were treated with specific systemic antibiotics during 12 weeks. The second stage MP was carried out at least two months after the first stage. CT scans were obtained after the first stage to manufacture defect-specific cages. In the final procedure a custom 3D printed PCL-TCP cage (Osteopore, Singapore) was placed in the defect in combination with biological adjuncts (BMAC, RIA derived autograft, iFactor and BioActive Glass). Bridging of the defect, assessed at six months by CT, was achieved in all cases. SPECT-scans 6 months post-operatively demonstrated active bone regeneration, also involving the central part of the scaffold. All three patients regained function and reported less pain with full weight-bearing. This case report shows that 3D printed PCL-TCP cages in combination with biological adjuncts is a novel addition to the surgical treatment of very large bone defects in (infected) posttraumatic nonunion of the tibia. This combination could overcome some of the current drawbacks in this challenging indication


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 100 - 100
1 Nov 2021
Papadia D Comincini F Pirchio P Puggioni V Bellanova G
Full Access

Introduction and Objective. Management of bone loss associated with bone contamination or infection represents a double biological and clinical challenge frequent in traumatology. The advent of new biomaterials can allow a different approach in the treatment of bone gap. The purpose of this study was to evaluate the prophylactic and therapeutic effectiveness of addition of a new absorbable bone substitute (BS) eluting different antibiotics in reconstruction of bone defects after infections and fractures with soft tissue damage. Materials and Methods. We conducted a review of patients with contaminated or infected bone defects treated using a new biomaterial, a porous composite of collagen matrices and Beta tricalcium phosphate (β TCP), able to provide a long-term release of different antibiotics. We have included treatment of osteomyelitis and osteosynthesis of exposed fracture (Gustilo Anderson 1–3b) or fractures with soft tissue damage and high risk of contamination. Surgical technique included debridement filling bone defect with BS eluting antibiotics, osteosynthesis (plate, nail, external fixator, kirschner wire), soft tissue coverage, and systemic antibiotic therapy. Radiographic and clinical data including complications (wound dehiscence, superficial or deep infection, osteomyelitis) were collected. Results. We treated 25 patients (21 male, 4 female) with mean age 47 yrs. (range 21–83). The locations treated (for incidence) was: 9 femurs (7 plates, 2 nail), 7 calcanei (one bilateral), 3 tibias, 2 forearms, 2 metatarsi, 2 hands, 1 elbow. 6 patients had large bone loss. 7 patients had bone infections (4 were Cierny Madern 4); 8 patients had osteosynthesis of exposed fractures Gustilo Anderson 1–3b (9 plate, one bilateral calcaneus). 8 patients had treatment for pseudoarthrosis of exposed fractures (6 femurs, 1 forearm, 1 metatarsus) and 3 patients a prophylactic treatment for calcaneal fractures with soft tissue damage. 4 deep infection were treated with multiple surgical debridement and new filling bone defect with BS eluting antibiotic with infection eradication. We have used a combination of vancomycin and gentamicin on 15 cases, vancomycin alone on 4 cases, combination of vancomycin and amikacin on 1 case and amikacin and Linezolid in a targeted multi drug resistance. At final follow-up functional outcome was good in all cases with bone healing. Conclusions. Extensive debridement is a fundamental requisite for eradication of bone infections and contamination. Filling of the bone void with loaded bio-composite eluting diversifiable local antibiotics with synergistic anti-biofilm activity is desirable. Treatment of this bone defects are advantaged when combining his reconstruction with BS and the possibility of release high antibiotic concentration at least for 10 days. This is an important complementing prophylactic and therapeutic antimicrobial option with adjuvant role to systemic therapy that enlarges the success rate


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 20 - 20
1 Jan 2017
Mohammad H Pillai A
Full Access

We describe a case series using calcium sulphate bio composite with antibiotics (Cerament/Stimulan) in treating infected metalwork in the lower limb. Eight patients aged 22–74 (7 males, 1 female) presented with clinical evidence of infected limb metal work from previous orthopaedic surgery. Metal work removal with application of either cerement in 5 cases (10–20ml including 175mg–350mg gentamycin) or stimulan in 3 cases (10–20ml including either 1g vancomycin or clindamycin 1.2g or 100mg tigecycline) into the site was performed. Supplemental systemic antibiotic therapy (oral/intravenous) was instituted based on intraoperative tissue culture and sensitivity. Four patients had infected ankle metalwork, 2 patients infected distal tibial metalwork and 2 had infected external fixators. Metal work was removed in all cases. The mean pre operative CRP was 15.8mg/l (range 1–56mg/l). The mean postoperative CRP at 1 month was 20.5mg/l (range 2–98mg/l). The mean pre op WCC was 7.9×10. 9. (range 4.7–10.5 ×10. 9. ). Mean post op WCC at 1 month was 7.1×10. 9. (range 5.0–9.2×10. 9. ). The organisms cultured included enterobacter, staphylococcus aureus, staphylococcus epidermidis, staphylococcus cohnii, stenotrophomonas, acinetobacter, group B streptococcus, enterococcus and escherichia coli. No additional procedures were required in any case. All surgical wounds went on to heal uneventfully. Infection control and union was achieved both clinically and radiologically in all cases. Our results support the use of a calcium sulphate bio composite with antibiotic as an adjuvant for effective local infection control in cases with implant related bone sepsis. The technique is well tolerated with no systemic or local side effects. We believe that implant removal, debridement and local antibiotic delivery can minimise the need for prolonged systemic antibiotic therapy in such cases


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 97 - 97
1 Jan 2017
Erkebulanovich TB Azimovna S Momynovich A Toleuovich E Zhetpisbaevich D Rozmatzhanovich T
Full Access

Bone infection occurring after fractures or orthopedic surgery can progress to the chronic stage and lead to poor results of treatment. Optimal treatment of chronic osteomyelitis are stabilization the fracture, biological recovery of bone defects and destroy bacterial infection. Traditional methods of treatment are systemic administration of antibiotics and surgical treatment of active infection focus. Systemic antibiotics are part of the standard therapy after surgical treatment of infected bone, but their effectiveness is limited due to malnutrition and low absorption at the site of infection. Moreover, long-term treatment and higher doses are associated with serious side effects. The aim of this investigation was to study the results of the complex treatment of patients with chronic osteomyelitis using biodegradable nanomaterials “PerOssal” as antibiotic delivery system. The study was performed at Regional center traumatology and orthopedics, Karaganda, Kazakhstan. A total 20 patient with post-traumatic/post-operative osteomyelitis were included in this open-label, prospective study. Bacteriological examination was taken with the determination of culture and sensitivity test preoperatively, during and postoperatively. After radical surgical debridement and ultrasound cavitation, the bone cavity was full filled with Perosal which can be loaded with different antibiotics depending from the antibiotic sensitivity test. Postoperative wound is completely was sutured. Systemic antibiotic treatment are allowed. The course of infection was monitored by determination leukocyte count and blood sedimentation rate; blood samples were taken befor, 24 hours after surgery, and on days 3, 7, 10, 14. Wound healing was assessed on days 2, 3, 7, 10, and at the time of removal of sutures. Resorption of implanted beads and bone reconstruction were evaluated by X-ray at after operation and at approximately one, three and six months after implantation. A total of 20 patients (mean age 38,1 (26 to 53), 14 male, 6 female) were treated with Perossal pellets (AAP, Germany) from October 2013 to April 2015. Mean leukocyte counts and blood sedimentation rate were within the normal laboratory range and did not indicate infectious complications during the first 21 days after surgery. Primary wound healing occurred in 18 patients and secondary wound healing in two patients. There were two cases of re-infection during the course of the study, one of them related to an incomplete eradication of infected tissue and multidrug-resistant strain occurring during the course of the study, the other is occurred that patient non-compliance. Radiographic analysis six months after surgery showed progressive resorption of the implanted pellets, but only 10 cases have decreasing size of defects on X-ray. This study in adult patients with chronic post-traumatic/post-operative osteomyelitis demonstrated that these biodegradable bone filler pellets which can be loaded with different antibiotics are a clinically useful local antibiotic delivery system and bone substitute which can be used as an alternative to other anti-infective implants. The implantation of the pellets was safety and well tolerated in all patients. This composite can provide adequate protection against bacterial infection during the first weeks after implantation and to support the bone healing process


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 33 - 33
1 Nov 2018
Moriarty F
Full Access

Device-associated infection remains a serious clinical problem in orthopaedic and trauma surgery. The emergence of resistant organisms such as methicillin resistant Staphylococcus aureus (MRSA) has further exacerbated this problem by limiting the range of treatment options. Currently, systemic antibiotic therapy is the cornerstone of treatment, alongside surgical resection of infected tissues and implant removal. The potential for antibiotic loaded biomaterials to support the prevention and treatment of infection is significant, although the currently available options are limited in number and often re-purposed from other applications e.g. antibiotic loading of bone cement. The first part of the talk will cover the basic concepts involved in antibiotic treatment, with an emphasis on the ideal antibiotic release kinetics from biomaterials, and how bacterial biofilms and antibiotic resistance influence antimicrobial efficacy. The next generation of biomaterials for antibiotic delivery should be specifically designed with this knowledge in mind. Regulatory approval of antimicrobial combination devices, however, is an evolving process as regulatory bodies seek more robust and clinically relevant efficacy data. Approval will require preclinical efficacy using standardized animal models that recapitulate the key features of the clinical disease. The second part of this talk will cover best practice in this important stage of development


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 62 - 62
1 Apr 2018
Soufi M Haque S Jayaraman S Faris B Shoaib A
Full Access

Aim. To determine if systemic toxicity occurs after the use of antibiotic loaded calcium sulphate in the treatment (1) of bone and soft tissue infection. Although antibiotic loaded calcium sulphate is increasingly used for the local treatment of bone and soft tissue infection, there is little data to demonstrate that systemic levels generated by local release of antibiotics are safe. For this reason, we routinely assay systemic levels of antibiotics. Methods. Patients with osteomyelitis or soft tissue infection underwent surgical debridement and lavage of the infected tissue in routine fashion. Patients with osteomyelitis were graded with the Cierny-Mader classification. Bone cavities and soft tissue dead spaces were packed with antibiotic loaded calcium sulphate (10–40 cc) loaded with Vancomycin (1–4 g) and Gentamicin (240–960 mg). The wounds were closed over the antibiotic loaded calcium sulphate. Patients underwent serial assays of Vancomycin and Gentamicin levels on the day of surgery and the first two post-operative days. Renal function was also measured. Results. 12 limbs in 10 patients were treated for osteomyelitis or soft tissue infection. There was 1 Cierny-Mader grade 1, 3 Cierny-Mader grade 3, and 2 Cierny-Mader grade 4. Two had deep soft tissue infection alone. There were 3 type A hosts and 7 type B hosts. The patients age ranged from 24 to 89 (mean 54). In patients without renal dysfunction, the systemic levels were either unmeasurable at the first assay, or below the acceptable trough level. (Mean 2.4 and 1.8 for Vancomycin and Gentamycin respectively). They had unmeasurable systemic levels at the third assay. In patients with renal dysfunction, systemic levels were in the therapeutic range determined for systemically administered antibiotics, but these levels remained high and did not decrease until patients had undergone their routine dialysis. Conclusions. In patients treated with antibiotic loaded Stimulan, antibiotic assays are not necessary in patients who have normal renal function, as they clear the systemic absorption as quickly as it is generated. Patients with impaired renal function should have lower doses of antibiotic used for their topically applied carrier, and should undergo assays regularly to ascertain if levels are remaining below the accepted range determined for systemically administered antibiotics. If they remain high, the antibiotic loaded calcium sulphate could be removed. * Stimulan (Biocomposites, Keele, UK)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 99 - 99
1 Jan 2017
van Vugt T Arts J Geurts J
Full Access

Chronic osteomyelitis is historically treated in a two stage fashion with antibiotic-loaded polymethylmethacrylate (PMMA) as local antibacterial therapy. However, two-stage surgeries are associated with high morbidity, long hospitalization and high treatment costs. In recent years new biomaterials were developed that allow to change this treatment algorithm. S53P4 bioactive glass is such a novel biodegradable antibacterial bone graft substitute that enables a one-stage surgery in local treatment of chronic osteomyelitis. This study aimed to explore the eradication of infection and bone healing capacities of S53P4 bioactive glass in clinical practice. In this prospective longitudinal outcome study, clinical applicability of S53P4 bioactive glass in treatment of patients with chronic osteomyelitis was assessed. All patients with clinically, haematologically and radiologically evident chronic osteomyelitis were included. All patients were treated with an extensive debridement surgery, S53P4 bioactive glass implantation and systemic antibiotic administration. Primary endpoint of this study is eradication of infection. During follow-up eradication was analysed based on clinical outcomes, blood samples (inflammatory parameters) and radiological outcomes. The secondary endpoint, bone healing, is assessed using conventional radiographic images of the treated region. Between 2011 and 2016, 25 patients were included in this study, with a mean follow-up of 23 months (range 4 – 57). Hospital stay was short with a mean of 18 days (range 4 – 40) and patients required an average of 1,4 surgeries (range 1 – 4). The inflammatory parameter C-reactive protein (CRP) showed a normalization after a mean duration of 46 days (range 0 – 211). At the end of follow-up haematological and clinical outcomes showed eradication of infection in 24 (96%) of all patients. Radiologically none of all patients showed persisting signs of infection and bone healing was observed in 22 (88%) patients based on changes on conventional radiographic images. One patient had a persistent infection without any bone healing, this patient had an infected non-union prior to surgery. There were two other patients with an initial infected non-union fracture which was not consolidated at last follow-up, although they had successful infection treatment. Another patient had a femoral fracture after surgery that needed additional surgery which did not interfere with eradication of infection. Four (16%) of all patients had initial wound healing problems related to compromised skin and/or soft tissue prior to surgery. Based on the results of our clinical experience, S53P4 bioactive glass can successfully be used in a one-stage procedure for treatment of chronic osteomyelitis. Eradication of infection was successful in almost all patients and so far no patients required a second surgery due to infection recurrence. Bone healing (incorporation of the bioactive glass) was seen in all patients except for the patients with an initial infected non-union fracture. As a consequence of these results, we changed our institutional protocol for treatment of chronic osteomyelitis to a one-stage approach instead of a two-step approach


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 96 - 96
1 Jan 2017
Thorrez L Putzeys G Duportail C Croes K Boudewijns M
Full Access

To prevent infections after orthopedic surgery, intravenous antibiotics are administered perioperatively. Cefazolin is widely used as the prophylactic antibiotic of choice. Systemic antibiotic therapy may however be less effective in longstanding surgery where bone allografts are used. Bone chips have been shown to be an effective carrier for certain types of antibiotics. Bone allografts impregnated with antibiotics may therefore provide the necessary local antibiotic levels for prophylaxis. To be efficient, a prolonged release from these bonechips is required. In contrast to vancomycin, for which prolonged release has clearly been proven effective from Osteomycin®, a commercially available impregnated bone allograft, no prolonged release bone chip preparations have been described so far for cefazolin. We developed a protocol to bind cefazolin in the porous structure of bone chips by means of a hydrogel composed of proteins naturally present in the human body. Three types of bone chips were evaluated: fresh frozen, decellularized frozen and decellularized lyophilized. Bone chips were incubated with 20 mg/ml cefazolin or treated with liquid hydrogel containing either 1 mg/ml fibrin or 1 mg/ml collagen and 20 mg/ml cefazolin. The cefazolin hydrogel was distributed in the porous structure by short vacuum treatment. Bone chips with cefazolin but without hydrogel were either incubated for 20 min- 4h or also treated with vacuum. Cefazolin elution of bone chips was carried out in fetal bovine serum and analyzed by Ultra Performance Liquid Chromatography – Diode Array Detection. Soaking of bone chips without hydrogel resulted in a quick release of cefazolin, which was limited to 4 hours. When vacuum was applied elution of >1 µg/ml cefazolin was measured for up to 36 hours. Combination with collagen hydrogel resulted in a higher cefazolin concentration released at 24 hours (3.9 vs 0.3 µg/ml), but not in a prolonged release. However, combination of decellularized frozen bone chips with fibrin hydrogel resulted in an initial release of 533 µg/ml followed by a gradual decline reaching the minimal inhibitory concentration for S. aureus at 72 hours (1.7 µg/ml), while not measurable anymore after 92 hours. Processed bone chips with hydrogel-cefazolin showed a markedly prolonged cefazolin release. When combined with a fibrin hydrogel, high initial peak levels of cefazolin were obtained, followed by a decreasing release over the following three days. This elution profile is desirable, since high initial levels are important to maximize anti-bacterial action whereas low levels of antibiotic for a limited time may stimulate osteogenesis. It is important that antibiotic release is ending after a few days as prolonged low levels of antibiotics are not clinically helpful and may lead to antibiotic resistance. Further preclinical studies are warranted to show effectiveness of hydrogel-cefazolin impregnated bone chips


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 98 - 98
1 Nov 2018
Ryan EJ Ryan AJ Philippart A Ciraldo FE Boccaccini AR Kearney CJ O'Brien FJ
Full Access

The bone infection osteomyelitis (typically Staphylococcus aureus) requires a multistep treatment process including: surgical debridement, long-term systemic high-dose antibiotics, and often bone grafting. With antibiotic resistance becoming increasingly concerning, alternative approaches are urgently needed. Herein, we develop a one-step treatment for osteomyelitis that combines local, controlled release of non-antibiotic antibacterials (copper) within a proven regenerative scaffold. To maximise efficacy we utilised bioactive glass – an established material with immense osteogenic capacity – as a copper ion delivery reservoir. Copper ions have also been shown to stimulate angiogenesis and induce MSC differentiation down an osteogenic lineage. To eliminate grafting requirements, the copper-doped BG was incorporated into our previously developed collagen scaffolds to produce multifunctional antibacterial, osteogenic, and angiogenic scaffolds. Scaffolds were fabricated by freeze-drying a co-suspension of collagen and bioactive glass particles (+/− copper doping, referred to as CuBG and BG, respectively) at a range of different concentrations (0–300% w/w bioactive glass/collagen). Scaffolds demonstrated a 2.7-fold increase in compressive modulus (300% CuBG vs. 0%; p≤0.01), whilst maintaining >98% porosity. The 300% CuBG scaffolds showed significant antibacterial activity against Staphylococcus aureus (p≤0.001). In terms of osteogenesis, both 100% and 300% CuBG scaffolds increased cell-mediated calcium deposition on the scaffolds at day 14 and 28 (p≤0.05 and p≤0.001), as confirmed by alizarin red staining. 100% CuBG scaffolds significantly enhanced angiogenesis by increased tubule formation (p≤0.01) and VEGF protein production (p≤0.001) (all ≥n=3). In summary, this single-stage, off-the-shelf treatment for osteomyelitis shows potential to minimise bone grafting and antibiotic dependence, while reducing hospital stays and costs


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1568 - 1574
1 Nov 2005
Day RE Megson S Wood D

Allograft bone is widely used in orthopaedic surgery, but peri-operative infection of the graft remains a common and disastrous complication. The efficacy of systemic prophylactic antibiotics is unproven, and since the graft is avascular it is likely that levels of antibiotic in the graft are low. Using an electrical potential to accelerate diffusion of antibiotics into allograft bone, high levels were achieved in specimens of both sheep and human allograft. In human bone these ranged from 187.1 mg/kg in endosteal (. sd. 15.7) to 124.6 (. sd. 46.2) in periosteal bone for gentamicin and 31.9 (. sd. 8.9) in endosteal and 2.9 (. sd. 1.1) in periosteal bone for flucloxacillin. The antibiotics remained active against bacteria in vitro after iontophoresis and continued to elute from the allograft for up to two weeks. Structural allograft can be supplemented directly with antibiotics using iontophoresis. The technique is simple and inexpensive and offers a potential means of reducing the rate of peri-operative infection in allograft surgery. Iontophoresis into allograft bone may also be applicable to other therapeutic compounds


Bone & Joint Research
Vol. 6, Issue 3 | Pages 132 - 136
1 Mar 2017
Yuenyongviwat V Ingviya N Pathaburee P Tangtrakulwanich B

Objectives

Vancomycin and fosfomycin are antibiotics commonly used to treat methicillin-resistant Staphylococcus aureus (MRSA) infection. This study compares the in vitro inhibitory effects against MRSA of articulating cement spacers impregnated with either vancomycin or fosfomycin.

Methods

Vancomycin-impregnated articulating cement spacers and fosfomycin-impregnated articulating cement spacers were immersed in sterile phosphate-buffered saline (PBS) solutions and then incubated. Samples were collected for bioactivity evaluation. The aliquots were tested for MRSA inhibition with the disc diffusion method, and the inhibition zone diameters were measured. The inhibition zone differences were evaluated using the Wilcoxon Rank Sum Test.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 845 - 850
1 Jun 2014
Romanò CL Logoluso N Meani E Romanò D De Vecchi E Vassena C Drago L

The treatment of chronic osteomyelitis often includes surgical debridement and filling the resultant void with antibiotic-loaded polymethylmethacrylate cement, bone grafts or bone substitutes. Recently, the use of bioactive glass to treat bone defects in infections has been reported in a limited series of patients. However, no direct comparison between this biomaterial and antibiotic-loaded bone substitute has been performed.

In this retrospective study, we compared the safety and efficacy of surgical debridement and local application of the bioactive glass S53P4 in a series of 27 patients affected by chronic osteomyelitis of the long bones (Group A) with two other series, treated respectively with an antibiotic-loaded hydroxyapatite and calcium sulphate compound (Group B; n = 27) or a mixture of tricalcium phosphate and an antibiotic-loaded demineralised bone matrix (Group C; n = 22). Systemic antibiotics were also used in all groups.

After comparable periods of follow-up, the control of infection was similar in the three groups. In particular, 25 out of 27 (92.6%) patients of Group A, 24 out of 27 (88.9%) in Group B and 19 out of 22 (86.3%) in Group C showed no infection recurrence at means of 21.8 (12 to 36), 22.1 (12 to 36) and 21.5 (12 to 36) months follow-up, respectively, while Group A showed a reduced wound complication rate.

Our results show that patients treated with a bioactive glass without local antibiotics achieved similar eradication of infection and less drainage than those treated with two different antibiotic-loaded calcium-based bone substitutes.

Cite this article: Bone Joint J 2014; 96-B:845–50.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1106 - 1109
1 Aug 2009
Branstetter JG Jackson SR Haggard WO Richelsoph KC Wenke JC

We used a goat model of a contaminated musculoskeletal defect to determine the effectiveness of rapidly-resorbing calcium-sulphate pellets containing amikacin to reduce the local bacterial count. Our findings showed that this treatment eradicated the bacteria quickly, performed as well as standard polymethylmethacrylate mixed with an antibiotic and had many advantages over the latter. The pellets were prepared before surgery and absorbed completely. They released all of the antibiotic and did not require a subsequent operation for their removal. Our study indicated that locally administered antibiotics reduced bacteria within the wound rapidly. This method of treatment may have an important role in decreasing the rate of infection in contaminated wounds.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 159 - 163
1 Jan 2010
Aykut S Öztürk A Özkan Y Yanik K İlman AA Özdemir RM

We studied the effects of coating titanium implants with teicoplanin and clindamycin in 30 New Zealand White rabbits which were randomly assigned to three groups. The intramedullary canal of the left tibia of each rabbit was inoculated with 500 colony forming units of Staphylococcus aureus. Teicoplanin-coated implants were implanted into rabbits in group 1, clindamycin-coated implants into rabbits in group 2, and uncoated implants into those in group 3. All the rabbits were killed one week later. The implants were removed and cultured together with pieces of tibial bone and wound swabs. The rate of colonisation of the organisms in the three groups was compared.

Organisms were cultured from no rabbits in group 1, one in group 2 but from all in group 3. There was no significant difference between groups 1 and 2 (p = 1.000). There were significant differences between groups 1 and 3 and groups 2 and 3 (p < 0.001). Significant protection against bacterial colonisation and infection was found with teicoplanin- and clindamycin-coated implants in this experimental model.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 304 - 310
1 Feb 2010
Jia W Zhang C Wang J Feng Y Ai Z

Platelet-leucocyte gel (PLG), a new biotechnological blood product, has hitherto been used primarily to treat chronic ulcers and to promote soft-tissue and bone regeneration in a wide range of medical fields. In this study, the antimicrobial efficacy of PLG against Staphylococcus aureus (ATCC 25923) was investigated in a rabbit model of osteomyelitis. Autologous PLG was injected into the tibial canal after inoculation with Staph. aureus. The prophylactic efficacy of PLG was evaluated by microbiological, radiological and histological examination. Animal groups included a treatment group that received systemic cefazolin and a control group that received no treatment.

Treatment with PLG or cefazolin significantly reduced radiological and histological severity scores compared to the control group. This result was confirmed by a significant reduction in the infection rate and the number of viable bacteria. Although not comparable to cefazolin, PLG exhibited antimicrobial efficacy in vivo and therefore represents a novel strategy to prevent bone infection in humans.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1655 - 1659
1 Dec 2007
Anwar HA Aldam CH Visuvanathan S Hart AJ

The biological significance of cobalt-chromium wear particles from metal-on-metal hip replacements may be different to the effects of the constituent metal ions in solution. Bacteria may be able to discriminate between particulate and ionic forms of these metals because of a transmembrane nickel/cobalt-permease. It is not known whether wear particles are bacteriocidal.

We compared the doubling time of coagulase negative staphylococcus, Staphylococcus aureus and methicillin resistant S. aureus when cultured in either wear particles from a metal-on-metal hip simulator, wear particles from a metal-on-polyethylene hip simulator, metal ions in solution or a control.

Doubling time halved in metal-on-metal (p = 0.003) and metal-on-polyethylene (p = 0.131) particulate debris compared with the control.

Bacterial nickel/cobalt-transporters allow metal ions but not wear particles to cross bacterial membranes. This may be useful for testing the biological characteristics of different wear debris. This experiment also shows that metal-on-metal hip wear debris is not bacteriocidal.