Advertisement for orthosearch.org.uk
Results 1 - 20 of 43
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 85 - 85
1 Feb 2017
Kretzer J Schroeder M Mueller U Sonntag R Braun S
Full Access

The numbers of anatomic total shoulder joint replacements (ATSR) is increasing during the past years with encouraging clinical results. However, the survivorship of ATSR is lower as compared to total knee and hip replacements. Although the reasons for revision surgery are multifactorial, wear-associated problems like loosening are well-known causes for long-term failure of ATSR. Furthermore there is lack of valid experimental wear tests for ATSR. Therefore the purpose of this study was to define experimental wear testing parameters for ATSR and to perform a wear study comparing ceramic and metallic humeral heads. Kinetic and kinematic data were adopted from in-vivo loading measurements of the shoulder joint (. orthoload.com. ) and from several clinical studies on shoulder joint kinematics. As activity an ab/adduction motion of 0 to 90° in combination with an ante/retroversion while lifting a load of 2 kg has been chosen. Also a superior-inferior translation of the humeral head has been considered. The wear assessment was performed using a force controlled AMTI joint simulator for 3×10. 6. cycles (Fig. 1) and polyethylene wear has been assed gravimetrically. The studied ATSR (Turon. TM. , DJO Surgical, USA) resulted in a polyethylene wear rate of 62.75 ± 1.60 mg/10. 6. cycles in combination with metallic heads. The ceramic heads significantly reduced the wear rate by 26.7 % to 45.99 ± 1.31 mg/10. 6. (p<0.01). The wear scars dimensions were in good agreement to clinical retrievals. This study is the first that experimentally studied the wear behavior of ATSR based on clinical and biomechanical data under load controlled conditions. In term of wear the analyzed ATSR could clearly benefit from ceramic humeral heads. However, in comparison to experimental wear studies of total knee and hip replacements the wear rate of the studied ATSR was relatively high. Therefore further research may focus on optimized wear conditions of ATSR and the hereby described method may serve as a tool to evaluate a wear optimization process


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 27 - 27
1 Dec 2017
Siroros N Verjans M Radermacher K Eschweiler J
Full Access

The glenohumeral joint is an important joint with large mobility of the human upper extremity. In shoulder arthroplasty patients often has an unsatisfactory outcome. In order to understand the biomechanical complexity of the shoulder, a novel computer controlled experimental shoulder simulator with an innovative muscle control were constructed. The main component of the simulator includes the active pneumatic muscles to replicate the deltoid and the rotator-cuff function and two springs as passive muscle. The aim of this study is to evaluate the impact of a variation of shoulder joint geometries on shoulder biomechanics in the basis of motion analysis. The radius of the glenoid cavity varied from 28–33mm with 2.5mm increment while the radius the humeral head are varied from 20.1–25.1 with 2.5mm increment. The “teach-in” function of the simulator allows an operator to assign the movement to the simulator where the lengths of the pneumatic muscles are recorded. Then the simulator repeats the assigned movement according to the recorded muscles length. The daily living activities includes abduction/adduction, internal/external rotation with adducted arm, and circumduction. The results show promising repeatability of the simulator with minor deviation. However, damage on the surface of the humeral head has been found which should be further studied for both shoulder behavior investigation and the shoulder simulator optimisation. Therefore, this study is a decent initial study toward the verification of the simulator and lead to a better understanding of shoulder biomechanical behavior to cope with the clinical problems in the future


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 34 - 34
10 May 2024
Penumarthy R Turner P
Full Access

Aim

Clavicular osteotomy was described as an adjunct to deltopectoral approach for improved exposure of the glenohumeral joint. This study aims to present contemporary outcomes and complications associated with the routine use of clavicular osteotomy by a single surgeon in a regional setting within New Zealand.

Methods

A retrospective case series of patients who have undergone any shoulder arthroplasty for any indication between March 2017 to August 2022. This time period includes all patients who had clavicular osteotomy(OS) and patients over an equal time period prior to the routine use of osteotomy as a reference group (N-OS).

Oxford Shoulder Score (OSS) and a Simple Shoulder Test (STT) were used to assess functional outcomes and were compared with the reported literature. Operative times and Complications were reviewed.


The anterior portion of the anatomical neck is used as a reference for the osteotomy in shoulder arthroplasty. Resection at this level is thought to remove a segment of a sphere which can accurately be replaced with a prosthetic implant. The objective of the study was to analyse the cartilage/metaphyseal interface relative to an ideal osteotomy plane to define points of reference the may recover retroversion accurately. Data were collected from 24 humeri using a novel technique, combining data acquired using a Microscribe digitiser and surface laser scanner. Rhinocerus NURBS modelling software was used to analyse the Cartilage/metaphyseal interface. The retroversion angle was calculated for the normal geometry and for the standard osteotomy along the anterior cartilage/metaphyseal interface. An ideal osteotomy plane was then created for each specimen and the perpendicular distance from the cartilage/metaphyseal interface was determined, identifying points of least deviation. The reference points were used to simulate a new osteotomy for which retroversion was calculated. Paired t-tests were used to compare the novel osteotomy and traditional osteotomy to the normal geometry. The mean retroversion for the normal geometry was 18.5±9.0 degrees. The mean retroversion for the traditional osteotomy technique was 29.5±10.7 degrees, significantly different from the original (p< 0.001). The mean retroversion using the novel osteotomy was 18.9±8.9 degrees and similar to the normal geometry (p=0.528). The traditional osteotomy resulted in a mean increase in retroversion of 38%. The increase in version may result in eccentric load on the glenoid, an alteration to the rotator cuff balance and poor clinical outcome. The novel osteotomy based on points identified around the cartilage/metaphyseal interface that deviated least from an ideal osteotomy plane resulted in more accurate recovery of head geometry. The novel technique may improve clinical outcome. Further investigation is warranted.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 38 - 38
22 Nov 2024
Barros BS Costa B Ribau A Vale J Sousa R
Full Access

Aim. Accurate diagnosis is key in correctly managing prosthetic joint infection(PJI). Shoulder PJI definition and diagnosis is challenging. Current PJI definitions, based overwhelmingly in hip/knee research, may not accurately diagnose shoulder PJI. Our aim is to compare the preoperative performance of two PJI definitions comparing it to definitive postoperative classification. Method. This is a retrospective study of patients who have undergone total shoulder revision surgery for infection between 2005 and 2022. Cases were classified using two different PJI definitions: a)the European Bone and Joint Infection Society (EBJIS) and; 2)the 2018 International Consensus Meeting(ICM) PJI specific shoulder definition. Preoperative classification was based on clinical features, inflammatory markers and synovial fluid leukocyte count and definitive classification also considered microbiology and histology results. Results. Preoperative and definitive PJI classification status of the 21 patients included were evaluated and is summarized in table 1. The shoulder specific 2018 ICM definition showed the highest agreement between preoperative and definitive classification (76.2%, k=0.153, p=0.006) compared to EBJIS (52.4%, k=0.205, p=0.006). In all cases, the classification was changed because of positive intraoperative microbiology (at least two identical isolates). Microbiology findings showed coagulase negative staphylococci, Staphyloccocus aureus and Cutibacterium acnes to be the most frequent. Four patients had polymicrobial infections. Conclusions. Both the EBJIS 2021 and 2018 ICM definitions have low accuracy in predicting shoulder PJI preoperatively. Clearly further studies with larger cohorts are in dire need focusing specifically on shoulder revision arthroplasty to improve on existing definitions. Caution is advised while extrapolating of criteria/thresholds recommended for hip/knee joints. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 68 - 68
1 Dec 2017
Pradier M Suy F Issartel B Dehecq C Loiez C Valette M Senneville E
Full Access

Aim

Propionibacterium acnes (PA) is an important cause of shoulder prosthetic joint infections (SPJIs) for which the optimal treatment has not yet been determined. Rifampicin and Levofloxacin both showed not benefit in recent experimental models of PA-SPJIs. We describe herein the experience of five different medical French centers in order to assess factors associated with patient's outcome with special emphasize on antibiotic regimens.

Method

A multicentric retrospective study was performed, on consecutive patients with PA – related SPJIs diagnosed on the basis of at least 2 or more positive cultures of either per-operative or joint aspiration and clinical history compatible with a PJI according to the current guidelines. All patients had surgical management, followed by systemic antibiotic therapy. Remission was defined as an asymptomatic patient with functioning prosthesis at the last contact.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 75 - 75
1 Dec 2022
Hunter J Lalone E
Full Access

Analyzing shoulder kinematics is challenging as the shoulder is comprised of a complex group of multiple highly mobile joints. Unlike at the elbow or knee which has a primary flexion/extension axis, both primary shoulder joints (glenohumeral and scapulothoracic) have a large range of motion (ROM) in all three directions. As such, there are six degrees of freedom (DoF) in the shoulder joints (three translations and three rotations), and all these parameters need to be defined to fully describe shoulder motion. Despite the importance of glenohumeral and scapulothoracic coordination, it's the glenohumeral joint that is most studied in the shoulder. Additionally, the limited research on the scapulothoracic primarily focuses on planar motion such as abduction or flexion. However, more complex motions, such as internally rotating to the back, are rarely studied despite the importance for activities of daily living. A technique for analyzing shoulder kinematics which uses 4DCT has been developed and validated and will be used to conduct analysis. The objective of this study is to characterize glenohumeral and scapulothoracic motion during active internal rotation to the back, in a healthy young population, using a novel 4DCT approach. Eight male participants over 18 with a healthy shoulder ROM were recruited. For the dynamic scan, participants performed internal rotation to the back. For this motion, the hand starts on the abdomen and is moved around the torso up the back as far as possible, unconstrained to examine variability in motion pathway. Bone models were made from the dynamic scans and registered to neutral models, from a static scan, to calculate six DoF kinematics. The resultant kinematic pathways measured over the entire motion were used to calculate the ROM for each DoF. Results indicate that anterior tilting is the most important DoF of the scapula, the participants all followed similar paths with low variation. Conversely, it appears that protraction/retraction of the scapula is not as important for internally rotating to the back; not only was the ROM the lowest, but the pathways had the highest variation between participants. Regarding glenohumeral motion, internal rotation was by far the DoF with the highest ROM, but there was also high variation in the pathways. Summation of ROM values revealed an average glenohumeral to scapulothoracic ratio of 1.8:1, closely matching the common 2:1 ratio other studies have measured during abduction. Due to the unconstrained nature of the motion, the complex relationship between the glenohumeral and scapulothoracic joints leads to high variation in kinematic pathways. The shoulder has redundant degrees of freedom, the same end position can result from different joint angles and positions. Therefore, some individuals might rely more on scapular motion while others might utilize primarily humeral motion to achieve a specific movement. More analysis needs to be done to identify if any direct correlations can be drawn between scapulothoracic and glenohumeral DoF. Analyzing the kinematics of the glenohumeral and scapulothoracic joint throughout motion will further improve understanding of shoulder mechanics and future work plans to examine differences with age


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 21 - 21
1 Jul 2020
Yew B Cheng J Choh A Yew A Lie D Chou S
Full Access

The function of the shoulder joint has traditionally been evaluated based on range of motion (ROM) in predefined anatomical planes and also by using functional scores, which assessed shoulder function based on the ability to conduct certain activities of daily living (ADLs). However, measuring ROM only in terms of flexion-extension, abduction-adduction and internal-external rotation may under-account for the 3-dimensional mobility of the shoulder joint. Furthermore, functional scores, such as the Oxford shoulder score or American shoulder and elbow surgeons (ASES) score, are subjective measures and are not an accurate assessment of shoulder joint function. In this study, we proposed the use of the globe model of the shoulder joint which can be used to provide an objective measure of the global ROM and also function of the shoulder joint – termed the Global and Functional arc of motion (GAM and FAM). Thirty-three young, healthy male patients (23.7 ± 1.5 years) were recruited and tasked to perform eight ADLs and a full humeral circumduction movement which represented their active global ROM. Reflective markers were placed in accordance to the International Society of Biomechanics (ISB) and optical-based motion capture cameras were used to track relative motion of the dominant humerus with respect to the thorax (i.e. thoracohumeral motion). The GAM and FAM were generated by plotting the thoracohumeral on a spherical coordinate system during global ROM and the eight ADLs respectively. Shoulder joint global ROM and function were quantified by calculating the area enclosed by the closed loop of GAM and FAM respectively. The spherical coordinate system, or more commonly referred to as the globe model, describes thoracohumeral movement using plane of elevation (POE), angle of elevation (AOE) and rotation. In our model, POE and AOE represents longitude and latitude of the globe respectively, and rotation is depicted using a red-green-blue (RGB) colour scale. Overall, subject's GAM of the shoulder joint covered an area of 4.64 ± 0.48 units2 compared to only 1.12 ± 0.26 units2 for the FAM. Subjects only required 24.4 ± 5.7 % of their global shoulder ROM for basic daily functioning. Studies that reduced shoulder joint movement into planar movements (i.e. sagittal, coronal and rotation) do not account for the 3-dimensional nature of the joint and doing so may overestimate the requirement of the shoulder joint for ADLs relative to its ROM in each plane. While others have attempted to use the globe model, such studies tend to reduce the globe into its descriptive angles (i.e. POE, AOE and rotation), reducing its intuitiveness. In contrast, by keeping an intact globe, the proposed globe model was more intuitive and yet capable of quantifying both shoulder joint global ROM and function. Doing so, we found that young healthy subjects only required approximately a quarter of their global ROM of the shoulder joint to complete the most common daily tasks, which was significantly less than what was previously reported


Shoulder septic arthritis is uncommon and frequently misdiagnosed, resulting in severe consequences. This study evaluated the demographics, bacteriological profile, antibiotic susceptibility, treatment regimens, and clinical outcomes. This is a 10-year retrospective observational analysis of 30 patients (20 males and 10 females) who were treated for septic arthritis of the shoulder. The data collecting process utilised clinical records, laboratory archives, and x-ray archives. We gathered demographic information, pre- and post-intervention clinical data, serum biochemical markers, and the results of imaging examinations. All patients had a surgical arthrotomy and joint debridement in the operating room, and specimens were taken for culture and sensitivity testing. The specimens were cultivated for at least seventy-two hours. Shoulder joint ranges of motion, comorbidities, and the presence of osteomyelitis were assessed clinically to determine the outcome. All statistical analyses were conducted using the STATA 17 statistical software. Analysis of correlation between categorical variables was performed using the chi-squared test. The majority of the study patients were black Africans (97%). The age range of the group was from 8 days to 17 years. At presentation, 33% of patients had a low-grade fever, whereas the majority (60%) had normal body temperature. The average length of symptoms was 3.9 days (ranged from 1 day to 15 days), and the majority of patients had an increased white cell count (83%) and C-reactive protein (98%). There was accumulation of fluid in the joint of all individuals who received shoulder ultrasound imaging. We noted a significant incidence of gram-positive cocci, which were mostly susceptible to first-line antibiotics. Shoulder stiffness affected 63% of patients and chronic osteomyelitis affected 50% of individuals. Neither the severity nor the duration of the symptoms was related to an increased risk of osteomyelitis. The results of this study revealed that the clinical characteristics and bacterial profile of septic arthritis of the shoulder conform to typical patterns. The likelihood of osteomyelitis and an unfavourable prognosis is considerable


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 66 - 66
24 Nov 2023
d'Epenoux Louise R Robert M Caillon H Crenn V Dejoie T Lecomte R Tessier E Corvec S Bemer P
Full Access

Background. The diagnosis of periprosthetic joint infection (PJI) remains a challenge in clinical practice and the analysis of synovial fluid (SF) is a useful diagnostic tool. Recently, two synovial biomarkers (leukocyte esterase (LE) strip test, alpha-defensin (AD)) have been introduced into the MSIS (MusculoSkeletal Infection Society) algorithm for the diagnosis of PJI. AD, although promising with high sensitivity and specificity, remains expensive. Calprotectin is another protein released upon activation of articular neutrophils. The determination of calprotectin and joint CRP is feasible in a routine laboratory practice with low cost. Purpose. Our objective was to evaluate different synovial biomarkers (calprotectin, LE, CRP) for the diagnosis of PJI. Methods. In this monocentric study, we collected SF from hip, knee, ankle and shoulder joints of 42 patients who underwent revision or puncture for diagnostic purposes. Exclusion criteria included a joint surgery in the previous 3 months and a diagnosis of a systemic inflammatory disease. PJI was diagnosed in a multidisciplinary consultation meeting (RCP) of the Reference Centers for Osteoarticular Infections of the Great West (CRIOGO). SF was analysed for LE, CRP and calprotectin. The cut-off values used were 50 mg/L for calprotectin, 8.8 mg/L for CRP and 125 WBC/µL for LE. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for these different synovial markers. Results. Of the 42 patients included, 28 were considered as infected and 14 uninfected. The statistical parameters are presented in Table 1. Conclusion. The present study shows that the synovial calprotectin assay has an excellent sensitivity and a 100% NPV for the diagnosis of PJI, suggesting that a result < 50 mg/L could exclude PJI. This promising study suggests that calprotectin should be included with synovial CRP in a new decision algorithm for the diagnosis of PJI. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 8 - 8
1 Oct 2022
Busch A Jäger M Giebel B Wegner A Bielefeld C Tertel T
Full Access

Aim. Periprosthetic joint infections (PJI) are severe complications after total joint arthroplasty (TJA). Up to now, a gold standard in the diagnostics of PJI is missing. Small extracellular vesicles (sEVs) are secreted by all types of cells and play a key role in immune response in presence of infection (1). In this prospective study, the diagnostic accuracy of sEVs in the synovial fluid to detect PJI of knee, hip and shoulder joints was investigated. We hypothesized increased surface markers of sEVs in PJI compared to aseptic complications (e.g. implant loosening, stress shielding related pain). Method. Synovial fluid from 48 patients with painful arthroplasty was examined. The distinction between aseptic and infectious cases was made on the basis of the 2018 Definition of Periprosthetic Hip and Knee Infection (2). 35 (72,9%) probands assigned to aseptic and 13 patients (27,1%) to PJI group. Immuno-fluorescence flow cytometry served to document the concentrations of CD9, CD63, CD66b, CD82 and HLA-DR on sEVs. Results. The concentration of CD9 surface marker on sEVs in synovial fluid was significantly lower (p=0.002) in PJI group than in aseptic group. In contrast, the levels of CD82 on sEVs in synovial fluid was significantly higher (p<0.0001) in the PJI group than in aseptic group. The concentrations of CD63, CD66b and HLA-DR on sEVs in synovial fluid did not differ significantly between the two cohorts (CD63: p=0.372; CD66b: p=0.634; HLA-DR: p=0.558). Conclusions. Overall, the significance of sEVs in the diagnostics of PJI is not well enough understood and the subject of current research and scientific discussion. Our data suggest, that CD82 and CD9 on sEVs in synovial fluid are promising biomarkers to differentiate between PJI and aseptic complications


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 83 - 83
1 Oct 2022
Browning S Manning L Metcalf S Paterson DL Robinson O Clark B Davis JS
Full Access

Aim. Culture negative (CN) prosthetic joint infections (PJI) account for approximately 10% of all PJIs and present significant challenges for clinicians. We aimed to explore the significance of CN PJI within a large prospective cohort study, and to compare their characteristics and outcomes with culture positive cases. Methods. The Prosthetic joint Infection in Australia and New Zealand Observational (PIANO) study is a prospective, binational, multicentre observational cohort study conducted at 27 hospitals between July 2014 and December 2017. We compared baseline characteristics and outcomes of all patients with culture negative (CN) prosthetic joint infection (PJI) from the PIANO cohort with culture positive (CP) cases. “Treatment success” was defined as absence of clinical or microbiological signs of infection, no need for ongoing antibiotics, and no need for revision or resection arthroplasty since the end of the initial treatment. We also describe PJI diagnostic criteria in the CN cohort and apply internationally recognised PJI diagnostic guidelines. Results. Of the 650 patients eligible for inclusion, 55 (8.5%) were CN and 595 were CP. Compared with the CP cohort, CN patients were more likely to be female [32 (58.2%) vs 245 (41.2%); p=0.02], involve the shoulder joint [5 (9.1%) vs. 16 (2.7%); p=0.03] and have a lower mean C-reactive protein (142 mg/L vs. 187 mg/L; p=0.02). Overall, outcomes were superior in CN patients, with culture negativity an independent predictor of treatment success at 24 months (aOR 3.78; 95%CI 1.65 – 8.67). Of the 55 CN cases meeting Infectious Diseases Society of America (IDSA) diagnostic criteria, 45 (82%) met European Bone and Joint Infection Society (EBJIS) criteria (probable or definite) and 39 (71%) met the 2013 Musculoskeletal Infection Society (MSIS) criteria. Conclusions. Culture negativity is an independent predictor of treatment success in PJI. It is unclear whether this is because some of them are not actually infections, or for other reasons such as lower bacterial load or earlier effective antibiotic treatment. Diagnostic criteria for PJI vary substantially in their sensitivity, with MSIS criteria being the least sensitive. Acknowledgements. This work is being presented on behalf of the broader PIANO investigators and the Australasian Society for Infectious Diseases Clinical Research Network. The PIANO study received seed funding from Heraeus Medical and the John Hunter Hospital Charitable Trust Fund


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 15 - 15
1 Apr 2019
Ramirez-Martinez I Smith S Joyce T
Full Access

INTRODUCTION. Shoulder joint prostheses have become the most commonly replaced after knee and hip artificial implants. Reverse shoulder arthroplasty (RSA) is the treatment option for patients with severe osteoarthritis, rotator cuff arthropathy or a massive rotator cuff tear with pseudoparalysis. Though successful, the long-term survival of such implants are limited by wear of the materials in contact [1, 2]. The aim of this study was to investigate RSA wear in vitro using a clinically relevant activities of daily living (ADLs). MATERIALS AND METHODS. Four new JRI Orthopaedics Reverse Shoulder 42 mm diameter VAIOS with cobalt-chromium (CoCr) glenospheres and ultra-high molecular weight polyethylene (UHMWPE) humeral components were tested. A five million cycles wear test was undertaken using the unique Newcastle Shoulder Wear Simulator with dilute bovine serum as a lubricant. “Mug to mouth” was performed as the ADL to the test prostheses in intervals of 100 cycles, following by 5 seconds of high load (450N) with no motion simulating an ADL such as “lifting an object”. This combined load cycle was then repeated. A fifth reverse shoulder prosthesis was subject to dynamic loading only in a soak control station. Wear was assessed gravimetrically and roughness (Sa) of the articulating surfaces was measured with a non-contacting profilometer. RESULTS AND DISCUSSION. The mean wear rate and standard deviation of the UHMWPE components was 11.4±3.7 mm. 3. /million cycles, while the CoCr components showed minimal wear over the test duration of 0.01± 0.02 mm. 3. /million cycles (Fig.1). Wear rates are comparable with Kohut et al. (14.1 mm. 3. /million cycles) [3] and Smith et al. (14.3±1.6 mm. 3. /million cycles) [4]. The CoCr glenospheres roughness was unchanged, from 32±8 nm Sa to 28±8 nm Sa over the 5 million cycles of the test (p=0.017), while the UHMWPE humeral components became smoother, from 692±123 nm Sa to 42±29 nm Sa (Fig.2), showing a statically significant change (p<0.001). CONCLUSION. The present study is the first wear test of artificial shoulder joints using a Motion-Load-Motion configuration as a clinically relevant physiological pattern of motion and load. Results are comparable with those found in the literature for in vitro testing of reverse shoulder replacements. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 13 - 13
1 May 2019
Iannotti J
Full Access

The number of shoulder arthroplasty procedures performed in the United States continues to rise. Currently, the number of procedures performed per year ranges from 55,000–80,000 and is expected to increase more than 300% in the coming years. Periprosthetic joint infection (PJI) is one of the most serious complications associated with arthroplasty surgery, leading to poor outcomes, increased cost, and technically difficult revision surgery. The incidence of infection following primary shoulder arthroplasty has been reported between 0.7% and 4%, representing 2.9–4.6% of all complications. Prosthetic shoulder joint infections are unlike prosthetic joint infections of the hip and knee. Shoulder PJIs are primarily indolent in nature and difficult to diagnose using traditional methods that have been shown to be accurate for periprosthetic infections of the hip and knee. The majority of infected revision shoulder arthroplasties are associated with growth of Propionibacterium acnes (P. Acnes). This slow-growing, anaerobic organism requires longer than normal incubation times for culture (7–21 days), and typically demonstrates a subtle, non-specific clinical presentation that can make the presence of infection difficult to identify. In the reported literature, P. Acnes accounts for about 70% of cases with positive cultures associated with revision for treatment of a painful shoulder arthroplasty and due to the bacteria's slow growing nature and virulence profile, the rate of infection following shoulder arthroplasty may often be underestimated. A more recent and promising tool for evaluation of periprosthetic infection has been analysis of synovial fluid. Synovial fluid biomarkers have been identified as part of the innate response to pathogens, and include pro-inflammatory cytokines and anti-microbial peptides, and marker levels have shown promise for improved diagnostic efficacy in hip and knee PJI. Currently, no highly predictive clinical test for diagnosis of PJI in the shoulder exists, however, several of these synovial biomarkers have recently been analyzed for their diagnostic capacity in the setting of periprosthetic shoulder infection. Synovial fluid cytokine analysis shows the potential to improve diagnosis of infection in revision shoulder arthroplasty. This information can help to guide decision-making in the management of PJI of the shoulder, including the decision to perform a single- vs. two-stage revision surgery, and the need for post-operative antibiotics following an unexpected positive culture result after revision surgery. However, there are still challenges to broader use of these synovial biomarkers. Synovial α-defensin (Synovsure, CD Diagnostic) is the only marker currently available as a commercial test, and no point-of-care test is currently available for any of the biomarkers to allow for intraoperative decision-making. While a preoperative synovial aspirate is possible to send for α-defensin analysis currently, with results back in approximately 24 hours, dry fluid aspirations are frequent in the shoulder because of the predominance of indolent pathogens and may limit utility of the test. In summary, indolent infection associated with P. acnes is a common cause for the painful total shoulder arthroplasty. Pre-operative diagnosis of infection is difficult as a result of the poor diagnostic accuracy of traditional methods of testing. Synovial biomarker testing may ultimately improve our ability to more accurately diagnosis and treat prosthetic shoulder joint infections


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 66 - 66
1 Jul 2020
Tat J Chong J Powell T Martineau PA
Full Access

Anterior shoulder instability is associated with osseous defects of the glenoid and/or humeral head (Hill-Sachs lesions). These defects can contribute to the pathology of instability by engaging together. There is a need to continue to develop methods to preoperatively identify engaging Hill-Sachs lesions for determining appropriate surgical management. The objective was to created a working moveable 3D CT model that allows the user to move the shoulder joint into various positions to assess the relationship between the Hill-Sachs lesion and the anterior glenoid rim. This technique was applied to a cohort series of 14 patients with recurrent anterior dislocation: 4 patients had undergone osteoarticular allografting of Hill-Sachs lesions and 10 control patients had undergone CT scanning to quantify bone loss but had no treatment to address bony pathology. A biomechanical analysis was performed to rotate each 3D model using local coordinate systems through a functional range using an open-source 3D animation program, Blender (Amsterdam, Netherlands). A Hill-Sachs lesion was considered “dynamically” engaging if the angle between the lesion's long axis and anterior glenoid was parallel. In the classical vulnerable position of the shoulder (abduction=90, external rotation=0–135), none of the Hill-Sachs lesions aligned with the anterior glenoid in any of our patients (Figure 1). Therefore, we considered there to be a “low risk” of engagement in these critical positions, as the non-parallel orientation represents a lack of true articular arc mismatch and is unlikely to produce joint instability. We then expanded our search and simulated shoulder positions throughout a physiological range of motion for all groups and found that 100% of the allograft patients and 70% of the controls had positions producing alignment and were “high risk” of engagement (p = 0.18) (Table 1). We also found that the allograft group had a greater number of positions that would engage (mean 4 ± 1 positions of engagement) compared to our controls (mean 2 ± 2 positions of engagement, p = 0.06). We developed a 3D animated paradigm to dynamically and non-invasively visualize a patient's anatomy and determine the clinical significance of a Hill-Sachs lesion using open source software and CT images. The technique demonstrated in this series of patients showed multiple shoulder positions that align the Hill-Sachs and glenoid axes that do not necessarily meet the traditional definition of engagement. Identifying all shoulder positions at risk of “engaging”, in a broader physiological range, may have critical implications towards selecting the appropriate surgical management of bony defects. We do not claim to doubt the classic conceptual definition of engagement, but we merely introduce a technique that accounts for the dynamic component of shoulder motion, and in doing so, avoid limitations of a static criteria assumed traditional definition (like size and location of lesion). Further investigations are planned and will help to further validate the clinical utility of this method. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 77 - 77
1 Feb 2020
Ramirez-Martinez I Smith S Trail I Joyce T
Full Access

Introduction. Despite the positive outcomes in shoulder joint replacements in the last two decades, polyethylene wear debris in metal-on-polyethylene artificial shoulder joints is well-known as a limitation in the long-term survival of shoulder arthroplasties systems. Consequently, there is an interest in the use of novel materials as an alternative to hard bearing surfaces such as pyrolytic carbon layer (PyroCarbon). Materials and Methods. In the present study, the unique Newcastle Shoulder Wear Simulator was used (Smith et al., 2015; Smith et al., 2016) to evaluate the wear behavior of four commercially available PyroCarbon humeral heads 43 mm diameter, articulating against conventional ultra-high molecular weight polyethylene (UHMWPE) glenoid inserts with a radius of curvature of 17.5 mm to form an anatomic total shoulder arthroplasty. A physiological combined cycled “Repeat-motion-load” (RML) (Ramirez-Martinez et al., 2019) obtained from the typical activities of daily life of patients with shoulder implants was applied as a simulator input. A fifth sample of the same size and design was used as a soak control and subjected to dynamic loading without motion during the wear test. The mean volumetric wear rate of PyroCarbon-on-polyethylene was evaluated over 5 million cycles gravimetrically and calculated on the basis of linear regression, as well as the change in surface roughness (S. a. ) of the components using a non-contacting white light profilometer throughout the test. Results. The gravimetric analysis showed a mean volumetric wear rate and standard deviation of 19.3±9.5 mm. 3. /million cycles for the UHMWPE glenoid inserts, whereas PyroCarbon humeral head counterparts did not exhibit a loss in mass throughout the test. The roughness values of the UHMWPE glenoid inserts decreased (P < .001), changing from 296±28 nm to 32±8 nm at the end of the test. In contrast, the PyroCarbon humeral heads did not show a significant change (P = .855) over the 5 million cycles; remained in the same range (21±2 nm to 20±10 nm) with no evidence of wear damage on the surface. Conclusions. This is the first in-vitro shoulder simulator study of a PyroCarbon on UHMWPE articulation. Wear rates were similar to that found to well-proven metal on UHMWPE shoulder arthroplasties. While it was interesting to see that the PyroCarbon did not roughen over the test duration, the lack of an appreciable reduction in wear of the UHMWPE component when articulated with an expensive and complex to manufacture PyroCarbon component likely means there is little clinical cost-benefit in the use of a PyroCarbon on UHMWPE shoulder implant. Declaration of competing interest. Prof. Ian A. Trail received some royalties and research support from Wright Medical Group N.V. None of the other authors, their immediate families, and any research foundation with which they are affiliated did not receive any financial payments or other benefits from any commercial entity related to the subject of this article. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 576 - 576
1 Dec 2013
Wang C Wong T
Full Access

Background:. Massive rotator cuff tear can cause functional disability due to instability and degenerative changes of the shoulder joint. In patients with massive irreparable rotator cuff tear, tendon transfer is often used as the salvage procedure. Latissimus dorsi and pectoris major transfer are technically demanding procedures and may incur complications. The biceps tendon transfer may provide a biologically superior tissue patch that improves the biomechanics of the shoulder joint in patients with irreparable rotator cuff tear. This study evaluated the functional outcomes of biceps tendon transfer for irreparable rotator cuff tear in 6 patients with two years and longer follow-up. Methods:. Between September 2006 and October 2011, 50 patients with 50 shoulders underwent surgical repair for MRI confirmed rotator cuff tear. Among them, six patients with massive irreparable rotator cuff tear were identified intraoperatively, and underwent proximal biceps tendon transfer to reconstruct the rotator cuff tear. The biceps tendon was tenodesed at the bicipital groove, and the proximal intra-articular portion of the biceps tendon was transected. The biceps graft was fanned out and the distal end fixed to the cancellous trough around the greater tuberosity with suture anchor. The anterior edge was sutured to the subscapularis and the posterior edge to the infraspinatus tendon or supraspinatus if present. Postoperative managements included sling protection and avoidance of strenuous exercises for 6 weeks, and then progressive rehabilitation until recovery. Results:. The evaluation parameters included VAS pain score, UCLA score, Constant score and AHES score, and X-rays of the shoulder. At follow-up of 25.3 ± 25.0 (range 22 to 63) months, the mean VAS pain score decreased from 9.3 ± 0.8 preoperatively to 1.7 ± 1.4 postoperatively (p < 0.001). All patients presented with significant improvements in pain and function of the shoulder for daily activities after surgery, however, only one patient achieved excellent results. There is no correlation of functional outcome with age, gender and body mass index. There was no infection or neurovascular complication. Discussion:. The biceps transfer provides soft tissue coverage of the humeral head, and restores the superior stability of the shoulder joint. The transferred biceps tendon also improves the mechanics and increases the compression force of the humeral head to the glenoid fossa. The results of the current study showed significant pain relief and improvement of shoulder function after biceps tendon transfer for irreparable rotator cuff tear. Conclusion:. Biceps tendon transfer is effective in the management of massive irreparable rotator cuff tear. The procedure is technically accessible with minimal surgical risks


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 136 - 136
1 Apr 2019
Meynen A Verhaegen F Debeer P Scheys L
Full Access

Background. Degeneration of the shoulder joint is a frequent problem. There are two main types of shoulder degeneration: Osteoarthritis and cuff tear arthropathy (CTA) which is characterized by a large rotator cuff tear and progressive articular damage. It is largely unknown why only some patients with large rotator cuff tears develop CTA. In this project, we investigated CT data from ‘healthy’ persons and patients with CTA with the help of 3D imaging technology and statistical shape models (SSM). We tried to define a native scapular anatomy that predesignate patients to develop CTA. Methods. Statistical shape modeling and reconstruction:. A collection of 110 CT images from patients without glenohumeral arthropathy or large cuff tears was segmented and meshed uniformly to construct a SSM. Point-to-point correspondence between the shapes in the dataset was obtained using non-rigid template registration. Principal component analysis was used to obtain the mean shape and shape variation of the scapula model. Bias towards the template shape was minimized by repeating the non-rigid template registration with the resulting mean shape of the first iteration. Eighty-six CT images from patients with different severities of CTA were analyzed by an experienced shoulder surgeon and classified. CT images were segmented and inspected for signs of glenoid erosion. Remaining healthy parts of the eroded scapulae were partitioned and used as input of the iterative reconstruction algorithm. During an iteration of this algorithm, 30 shape components of the shape model are optimized and the reconstructed shape is aligned with the healthy parts. The algorithm stops when convergence is reached. Measurements. Automatic 3D measurements were performed for both the healthy and reconstructed shapes, including glenoid version, inclination, offset and critical shoulder angle. These measurements were manually performed on the mean shape of the shape model by a surgeon, after which the point-to-point correspondence was used to transfer the measurements to each shape. Results. The critical shoulder angle was found to be significantly larger for the CTA scapulae compared to the references (P<0.01). When analyzing the classified scapulae significant differences were found for the version angle in the scapulae of group 4a/4b and the critical shoulder angle of group 3 when compared to the references (P<0.05). Conclusion. Patients with CTA have a larger critical shoulder angle compared with reference patients. Some significant differences are found between the scapulae from patients in different stages of CTA and healthy references, however the differences are smaller than the accuracy of the SSM reconstruction. Therefore, we are unable to conclude that there is a predisposing anatomy in terms of glenoid version, inclination or offset for CTA


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 22 - 22
1 May 2019
Romeo A
Full Access

Patient perceptions regarding the functional outcomes and return to sports after shoulder replacement are often pessimistic, with many patients presenting for shoulder replacement surgery after months or years of avoiding the procedure so they could continue to live the current life they have, despite the increasing pain and dysfunction. Less common, but becoming more frequent, patients present with expectations that they will be able to return to all activities including heavy resistance training, cross-fit, rock climbing, and other strenuous overhead sports. In the past, little information has been available regarding the activities of shoulder arthroplasty patients after surgery. Typically, the boundaries have been set by the surgeon, with many patients cautioned or even prohibited from overhead sports, weight training, or heavy work responsibilities. A typical set of guidelines may include no repetitive overhead sports, except for recreational swimming, and no lifting over 20 pounds. Golf, jogging, hiking and other activities are allowed. The origin of these restricted guidelines and expectations is unknown, but many believe that since the results of shoulder replacements are less favorable in younger patients, it may be due to the overuse or abuse of the shoulder joint that is more typical at a younger age. Others have suggested that common sense prevails and that an artificial joint made of metal and plastic has a finite number of total movements and tolerance to resistance activities, and therefore keeping these activities at a minimum would extend the longevity of the artificial joint. None of these concepts are backed up by evidence-based literature, essentially reflecting the personal bias of the surgeons who care for patients with these problems. Despite all of the sophisticated research, scoring scales, outcome measures, and value-based metrics, the only outcome that really matters is whether the patient can return back to their normal way of life, at home, at work, during sport, or any activity that is important to them. Recent studies of patients who have had joint replacement surgery have revealed that our patients who participated in sports and work activities before surgery have a strong predilection to returning to those activities after successful shoulder replacement. The most common sports that shoulder arthroplasty patients enjoy including golf, swimming, tennis, but may also include many other choices including fitness activities, rowing, skiing, basketball, and softball. As expected, the return to these sports is less for reverse shoulder arthroplasty patients vs. anatomic shoulder arthroplasty patients. In a systematic review, more than 90% of anatomic shoulder replacement patients returned to sport, while 75% of reverse shoulder arthroplasty patients returned to some sporting activity. This may reflect the constraints of the reverse prosthesis, or, quite possibly reflect the typically older age and more sedentary lifestyle of patients who are indicated for reverse shoulder arthroplasty. In addition, if the patient had a preoperative expectation of return to recreational and sports activities as part of their normal way of life, their final results demonstrated better overall outcomes. Shoulder arthroplasty surgeons should be concerned about the outcomes desired by our patients, and the results that provide true value to their lives. We are now more aware of the activities that they are going to return to, whether we recommend restrictions or not


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 66 - 66
1 Dec 2017
Sabesan V Petersen-Fitts GR Lombardo DJ Liou W
Full Access

Manufacturers of reverse shoulder arthroplasty (RSA) implants have recently designed innovative implants to optimise performance in rotator cuff deficient shoulders. These advancements are not without tradeoff and can have negative biomechanical effects. The objective of this study was to develop an integrated FEA kinematic model to compare the muscle forces and joint reaction force (JRF) of 3 different RSA designs. A kinematic model of a normal shoulder joint was adapted from the Delft model and integrated with the OpenSim shoulder model. Static optimisations then allowed for calculation of the individual muscle forces, moment arms and JRF relative to net joint moments. Three dimensional computer models of humeral lateralised design (HLD), glenoid lateral design (GLD), and Grammont design (GD) RSA were integrated and parametric studies were performed. Overall there were decreases in deltoid and rotator cuff muscle forces for all 3 RSA designs. These decreases were greatest in the middle deltoid of the HLD model for abduction and flexion and in the rotator cuff muscles under both internal and external rotation. The joint reactive forces in abduction and flexion decreased similarly for all RSA designs compared to the normal shoulder model, with the greatest decrease seen in the HLD model. These findings demonstrate that the design characteristics implicit in these modified RSA prostheses result in kinematic differences most prominently seen in the deltoid muscle and overall joint reactive forces. Further research utilising this novel integrated model can help guide continued optimisation of RSA design and clinical outcomes