Advertisement for orthosearch.org.uk
Results 1 - 20 of 65
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1347 - 1353
1 Oct 2009
Grob D Bartanusz V Jeszenszky D Kleinstück FS Lattig F O’Riordan D Mannion AF

In a prospective observational study we compared the two-year outcome of lumbar fusion by a simple technique using translaminar screws (n = 57) with a more extensive method using transforaminal lumbar interbody fusion and pedicular screw fixation (n = 63) in consecutive patients with degenerative disease of the lumbar spine. Outcome was assessed using the validated multidimensional Core Outcome Measures Index. Blood loss and operating time were significantly lower in the translaminar screw group (p < 0.01). The complication rates were similar in each group (2% to 4%). In all, 91% of the patients returned their questionnaire at two-years. The groups did not differ in Core Outcome Measures Index score reduction, 3.6 (. sd. 2.5) (translaminar screws) vs 4.0 (. sd. 2.8) (transforaminal lumbar interbody fusion) (p = 0.39); ‘good’ global outcomes, 78% (translaminar screws) vs 78% (transforaminal lumbar interbody fusion) (p = 0.99) or satisfaction with treatment, 82% (translaminar screws) vs 86% (transforaminal lumbar interbody fusion) (p = 0.52). The two fusion techniques differed markedly in their extent and the cost of the implants, but were associated with almost identical patient-orientated outcomes. Extensive three-point stabilisation is not always required to achieve satisfactory patient-orientated results at two years


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 2 - 2
1 Sep 2021
Hashmi SM Hammoud I Kumar P Eccles J Ansar MN Ray A Ghosh K Golash A
Full Access

Objectives. This presentation discusses the experience at our Centre with treating traumatic thoracolumbar fractures using percutaneous pedicle screw fixation and also looks at clinical and radiological outcomes as well as complications. Design. This is a retrospective study reviewing all cases performed between Jan 2013 and June 2019. Subjects. In our study there were 257 patients in total, of which there were 123 males and 134 females aged between 17 and 70. Methods. We reviewed the case notes and imaging retrospectively to obtain the relevant data. Results. A total of 257 patients were included, 123 males and 134 females; the mean age was 47.6 years. The majority of injuries were from fall from significant height. In 98 cases the fracture involved a thoracic vertebra and in 159 cases a lumbar vertebra. Percutaneous pedicle screw fixation was performed either one level above and below fracture or Two levels above and below the fracture depending upon the level of injury. Forty two cases were treated with additional short pedicle screws at the level of fracture. More than 15% (39) of patients presented with a neurological deficit on admission and more than 80% (32) of those showed post-operative improvement in their neurology as per Frankel Grading system. The mean Operative time was 117minutes +− 45, and mean length of hospital stay was 7.2 +− 3.8 days, with significant improvement in Visual analogue score. Percutaneous fixation achieved a satisfactory improvement in radiological parameters including sagittal Cobb angle (SCA) post-operatively in all patients. The vast majority of patients achieved a good functional outcome according to modified Macnab criteria. Follow up was for a maximum of two years, with relevant imaging at each stage. Ten (3.8%) patients had wound infection with three patients requiring wound debridement. Four patients had upper level screws pulled out and in Four cases one screw was misplaced. All eight had revision surgery. Conclusions. Percutaneous pedicle screw fixation is a safe surgical option with comparable outcomes to open surgery and a potential reduction in perioperative morbidity. Percutaneous pedicle screw fixation is the primary surgical technique to treat traumatic thoracolumbar fractures at our Centre. There were no major complications in our series, with good functional outcome following surgery


Bone & Joint Research
Vol. 10, Issue 12 | Pages 797 - 806
8 Dec 2021
Chevalier Y Matsuura M Krüger S Traxler H Fleege† C Rauschmann M Schilling C

Aims. Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods. Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S. 4. ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results. Experimental pull-out strengths were excellently correlated to the µFE pull-out stiffness of the ROI (R. 2. > 0.87) and FV (R. 2. > 0.84) models. No significant difference due to screw design was observed. Cement augmentation increased pull-out stiffness by up to 94% and 48% for L and R screws, respectively, but only increased bending stiffness by up to 6.9% and 1.5%, respectively. Cementing involving only one screw tip resulted in lower stiffness increases in all tested screw designs and loading cases. The stiffening effect of cement augmentation on pull-out and bending stiffness was strongly and negatively correlated to local bone density around the screw (correlation coefficient (R) = -0.95). Conclusion. This combined experimental, µCT and µFE study showed that regional analyses may be sufficient to predict fixation strength in pull-out and that full analyses could show that cement augmentation around pedicle screws increased fixation stiffness in both pull-out and bending, especially for low-density bone. Cite this article: Bone Joint Res 2021;10(12):797–806


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 545 - 549
1 Apr 2010
Li W Chi Y Xu H Wang X Lin Y Huang Q Mao F

We reviewed the outcome of a retrospective case series of eight patients with atlantoaxial instability who had been treated by percutaneous anterior transarticular screw fixation and grafting under image-intensifier guidance between December 2005 and June 2008. The mean follow-up was 19 months (8 to 27). All eight patients had a solid C1–2 fusion. There were no breakages or displacement of screws. All the patients with pre-operative neck pain had immediate relief from their symptoms or considerable improvement. There were no major complications. Our preliminary clinical results suggest that percutaneous anterior transarticulation screw fixation is technically feasible, safe, useful and minimally invasive when using the appropriate instruments allied to intra-operative image intensification, and by selecting the correct puncture point, angle and depth of insertion


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XX | Pages 14 - 14
1 May 2012
Mehdian H Mehdian R Copas D
Full Access

Objective. The use of all pedicle screw constructs for the management of spinal deformities has gained widespread popularity. However, the placement of pedicle screws in the deformed spine poses unique challenges for the spinal surgeon. The purpose of this study was to evaluate the complications and radiological outcomes of surgery in 124 consecutive patients with spinal deformity. These patients underwent correction of coronal and sagittal imbalance with segmental pedicle screw fixation only. Background. All pedicle screw constructs have been associated with improved correction in all three planes. In patients with severe deformity, such constructs can obviate the need for anterior surgeries, and the higher implant cost is offset by the avoidance of dual anterior and posterior approaches. Pedicle screw fixation enables enhanced correction of spinal deformities, but the technique is still not widely applied for thoracic deformities for fear of neurological complications. This is a retrospective study that was carried out on 124 patients who underwent segmental screw fixation for coronal and sagittal spinal deformities. The purpose of this study was to evaluate the complications and outcomes of this technique and also assess the evidence of enhanced correction. Material and Methods. A total of 124 consecutive patients subjected to pedicle screw fixation for spinal deformities were analysed after a minimum period of follow-up of two years. Etiologic diagnoses were idiopathic scoliosis in 32, neuromuscular scoliosis 48, Scheuermann's kyphosis in 28 and others 16. They were reviewed using the medical records and preoperative, intraoperative and postoperative radiographs. Computed tomography was performed when screw position was questionable. Deformity correction was determined on preoperative and postoperative radiographs. The positions of the screws were evaluated using intraoperative and postoperative radiographs. There were 51 male and 73 female patients with the mean age of 17.2 years (range, 10-25 years). The average cobb angle for scoliosis and kyphosis were 55°(range 45°-85°) and 72° (range 68°-100°) respectively. Results. A total of 2784 pedicle screws were inserted and 1488 screws were inserted in the thoracic spine (18 screws/patient). Screw-related neurological complications occurred in two patients 0.4%; these comprised a transient paraparesis and dural tear. Other complications comprised six intraoperative pedicle fractures, 12 screw loosening, four postoperative infections and one haemothorax. There were no significant screw-related neurological or visceral complications. The average correction was 78% for scoliosis and 51% for kyphosis. The mean estimated blood loss was 653 ml (range, 510-850), the mean operation time was 148 minutes (range, 120-220). Conclusion. We were able to demonstrate that application of pedicle screw construct is safe and advantageous in the management of spinal deformities. Significant correction has been achieved with a single stage posterior surgery in all groups. Scoliosis and kyphotic deformity corrections were 78% and 51% respectively; this is far superior to correction achieved with one stage surgery with other constructs. This study showed that improved derotation has decreased the need for thoracoplasty, thus eliminating its risk of associated morbidity. Superior control of the deformity obviated the need for an anterior approach in severe curves. Improved correction, lower morbidity and shorter hospitalisation has compensated for higher implant cost. We believe using all pedicle screw fixation is a relatively safe procedure and offers an excellent correction. This correction was maintained throughout the follow up period. Despite our safety record in thoracic pedicle screw placement, we believe this technique can be potentially dangerous in inexperienced hands, and requires a long learning curve. Therefore, a thorough anatomical knowledge of pedicle morphology, a detailed analysis of pre-operative imaging coupled with experience is essential to avoid complications. Ethics approval None. Interest Statement None


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1101 - 1106
1 Aug 2012
Jindal N Sankhala SS Bachhal V

The purpose of this study was to determine whether patients with a burst fracture of the thoracolumbar spine treated by short segment pedicle screw fixation fared better clinically and radiologically if the affected segment was fused at the same time. A total of 50 patients were enrolled in a prospective study and assigned to one of two groups. After the exclusion of three patients, there were 23 patients in the fusion group and 24 in the non-fusion group. Follow-up was at a mean of 23.9 months (18 to 30). Functional outcome was evaluated using the Greenough Low Back Outcome Score. Neurological function was graded using the American Spinal Injury Association Impairment Scale. Radiological outcome was assessed on the basis of the angle of kyphosis. Peri-operative blood transfusion requirements and duration of surgery were significantly higher in the fusion group (p = 0.029 and p < 0.001, respectively). There were no clinical or radiological differences in outcome between the groups (all outcomes p > 0.05). The results of this study suggest that adjunctive fusion is unnecessary when managing patients with a burst fracture of the thoracolumbar spine with short segment pedicle screw fixation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 66 - 66
1 Jun 2012
König MA Jehan S Balamurali G Seidel U Heini P Boszczyk BM
Full Access

Introduction. Isolated U-shaped sacral fractures are rare entities, mostly seen in polytraumatized patients, and hence, they are difficult to diagnose. While the pelvic ring remains intact across S2/S3, the U-shaped fracture around S1 leads to marked instability between the base of the spine and the pelvis. As severe neurological deficits can occur, timely treatment of these fractures is crucial. We present a novel technique of percutaneous reduction and trans-sacral screw fixation in U-shaped fractures. Material and Methods. 3 multiply injured patients with u-shaped sacral fractures (female, age 21.7±7.23). Two underwent immediate fracture fixation. In the third case delayed reduction and fixation was performed after referral 6 weeks following open decompression. In prone position, a pair of Schanz pins was inserted into pelvis at the PSIS. A second pair of Schanz pins was inserted into S1 or L5. All pins were inserted percutaneously. The fracture was reduced indirectly, using the Schanz pins as levers. After image intensifier control of the reduction result, two trans-sacral screws were inserted for finite fixation. Results. In all three cases, this novel method of percutaneous reduction allowed an anatomical sacral alignment and stabilization with trans-sacral screws was initially sufficient. At 1 year follow-up, both immediately fixed fractures showed an anatomical sacral alignment. Both had no neurological deficits, no signs of screw-loosening and were pain free. Unfortunately the delayed fixation showed a new tilt and hence loss of sacral alignment. This might be due to posterior structural integrity loss after decompression. Conclusion. U-shaped sacral fractures are rare, but correct and immediate treatment is paramount to achieve good outcome. Percutaneous reduction and screw fixation offers a less invasive treatment method. Anatomical alignment and stabilisation is possible and time of surgery can be reduced significantly


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 67 - 67
1 Apr 2012
Kabir S Casey A
Full Access

To describe a modification of the existing technique for C2 translaminar screw fixation that can be used for salvage in difficult cases. Bilateral crossing C2 laminar screws have recently become popular as an alternative technique for C2 fixation. This technique is particularly useful in patients with anomalous anatomy, as a salvage technique where other modes of fixation have failed or as a primary procedure. However, reported disadvantages of this technique include breach of the dorsal lamina and spinal canal, early hardware failure and difficulty in bone graft placement due to the position of the polyaxial screw heads. To address some of these issues, a modified technique is described. In this technique, the upper part of the spinous process of C2 is removed and the entry point of the screw is in the base of this removed spinous process. From October 2008 to March 2009, 6 patients underwent insertion of unilateral translaminar screws using our technique. The indications were: basilar invagination(three cases), C1/C2 fracture (two cases), tumour (one case). Age varied from 22 to 81 years (mean 48 years). All patients had post-operative x-ray and CT scan to assess position of the screws. Mean follow-up was 6 months. The screw position was satisfactory in all patients. There were no intraoperative or early postoperative complications. Our modification enables placement of bone graft on the C2 lamina and is also less likely to cause inadvertent cortical breach. Because of these advantages, it is especially suitable for patients with advanced rheumatoid arthritis with destruction of the lateral masses of C2 or as part of a hybrid construct in patients with unilateral high riding vertebral artery. This technique is not suitable for bilateral translaminar screw placement


Introduction. We report the outcomes of minimally invasive technique for posterior lumbar interbody fusion (PLIF) procedure using Hollow Modular Anchorage (HMA) screws supplemented by routine pedicle screw fixation (Dynesis). Patients and Methods. Seventy-nine patients, who had undergone PLIF procedure using HMA screws supplemented by pedicle screw fixation, were included. Patients deemed suitable for surgery following discography under sedation, with Marcaine instillation establishing reducibility of the listhesis and temporary relief of symptoms. Clinical outcome included visual analogue scale scores for leg pain and back pain, Oswestry Disability Index (ODI) and SF-36 questionnaires. Results. Average age was 59 (range: 27-85). Mean follow- up was 5 years (range: 1-10). All cases went into union. None were lost to follow-up. Average length of stay was 24 hours (18-72 hours). All clinical parameters improved except SF-36. Mean ODI improved from 54 (range: 44-89) preoperatively to 33 (17-55) postoperatively (statistically significant, p=0.004). Back pain relief improved in visual analogue scale from average of 68 (range: 60-100) preoperatively to 37 postoperatively (range: 8:46) (statistically significant, p= 0.022). Leg pain relief improved from 53 (range: 31-100) preoperatively to 28 postoperatively (range: 4:60) (statistically significant, p= 0.007). Although mean SF-36 score improved from 37 (range: 10-41) preoperatively to 47 (range: 53-94) postoperatively (statistically insignificant, p=0.592). Complications included: one infection required removal of implant; two temporary motor weaknesses related to L5 nerve root; four required removal of the pedicle screw due to pain or loosening. Discussion. Our results are encouraging. Interbody HMA screws are porous hollow titanium screws with favourable biomechanical characteristics. Rather than square cages, they permit accurate placement of implant. Dynesys offers the option of extension and flexible support for the adjacent segment. Conclusion. PLIF supplemented with pedicle fixation is a reliable and safe procedure for degenerative spondylolisthesis. SF-36 is less sensitive for assessing spinal surgery outcome


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_6 | Pages 9 - 9
1 Feb 2016
Wilson L Altaf F Tyler P Sedra F
Full Access

Many operations have been recommended to treat Pars Interarticularis fractures that have separated and are persistently symptomatic, but little other than conservative treatment has been recommended for symptomatic incomplete fractures.

10 consecutive patients aged 15–28 [mean 21.7 years] were treated operatively between 2010–2014. All but one were either professional athletes [3 cricketers, 2 athletics, 1 soccer] or academy cricketers [3 patients]. 8 patients had unilateral fractures, and two had bilateral fractures at the same level. The duration of pre-operative pain and disability with exercise ranged from 4–24 months [mean 15.4 months].

The operation consists of a percutaneous compression screw inserted through a 1.5cm midline skin incision under fluoroscopic guidance: 6 cases were also checked with the O-arm intra-operatively. Post-operation the patients were mobilised with a simple corset and discharged the following day with a customised rehabilitation program.

All 12 fractures in 10 patients healed as demonstrated on post-operative CT scans at between 3–6 months. One patient had the screw revised at 24 hours for an asymptomatic breach, and one patient developed a halo around the fracture site without screw loosening, and had a successful revision operation to remove the screw and graft the pars from the screw channel. All patients achieved a full return to asymptomatic activity, within a timescale of 4–12 months post-surgery, depending on the sport.

Athletes that have persistent symptoms from incomplete pars interarticularis fractures should consider percutaneous fixation rather than undergoing prolonged or repeated periods of rest.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 93 - 97
1 Jan 2012
Lee JH Lee J Park JW Shin YH

In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis.


Bone & Joint Research
Vol. 9, Issue 10 | Pages 653 - 666
7 Oct 2020
Li W Li G Chen W Cong L

Aims

The aim of this study was to systematically compare the safety and accuracy of robot-assisted (RA) technique with conventional freehand with/without fluoroscopy-assisted (CT) pedicle screw insertion for spine disease.

Methods

A systematic search was performed on PubMed, EMBASE, the Cochrane Library, MEDLINE, China National Knowledge Infrastructure (CNKI), and WANFANG for randomized controlled trials (RCTs) that investigated the safety and accuracy of RA compared with conventional freehand with/without fluoroscopy-assisted pedicle screw insertion for spine disease from 2012 to 2019. This meta-analysis used Mantel-Haenszel or inverse variance method with mixed-effects model for heterogeneity, calculating the odds ratio (OR), mean difference (MD), standardized mean difference (SMD), and 95% confidence intervals (CIs). The results of heterogeneity, subgroup analysis, and risk of bias were analyzed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 33 - 33
1 Jun 2012
Saxena A Alakandy L
Full Access

Purpose. Posterior lumbar fusion using minimally invasive surgical (MIS) techniques are reported to minimise postoperative pain, soft tissue damage and length of hospital stay when compared to the traditional open procedure. Methods. This is a review of patients who underwent MIS for posterolateral lumbar fusion in a single practice over a 2-year period. Results. Twenty-eight patients underwent this procedure. The median age was 57 (range 34-80). Male:female ratio was 1:1. The most common symptom was radicular pain (n=26). Two patients had back pain without radicular symptoms. Primary degenerative spondylolisthesis was seen in 22 patients and post-laminectomy spondylolisthesis in 3 patients. Transforaminal interbody fusion (TLIF) with pedicle screw fixation was the commonest procedure (20) while the rest had pedicle screw fixation and inter-transverse fusion. Along with fusion, nerve root decompression alone was performed in 19, while 5 had decompression of the central spinal canal. Intra-operative navigation was used to assist screw placement in 5 patients. The typical hospital stay was 3 days. All but two patients were mobilised the same or the following day. Twenty-one patients with radiculopathy (80%) reported improvement in VAS at 6-months. One patient suffered irreversible nerve root injury (L5). Significant pedicle breach without nerve injury by a screw was seen in one patient. Conclusion. Minimally invasive TLIF and pedicle screw fixation lumbar degenerative condition is a safe procedure with complications comparable to traditional open techniques. Minimal muscle dissection and soft tissue damage allows for earlier ambulation and reduced hospital stay. The procedure however required longer operative time and increased exposure to intra-operative x-rays


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1222 - 1226
1 Sep 2016
Joestl J Lang N Bukaty A Platzer P

Aims. We performed a retrospective, comparative study of elderly patients with an increased risk from anaesthesia who had undergone either anterior screw fixation (ASF) or halo vest immobilisation (HVI) for a type II odontoid fracture. Patients and Methods. A total of 80 patients aged 65 years or more who had undergone either ASF or HVI for a type II odontoid fracture between 1988 and 2013 were reviewed. There were 47 women and 33 men with a mean age of 73 (65 to 96; standard deviation 7). All had an American Society of Anesthesiologists score of 2 or more. Results. Patients who underwent ASF had a significantly better outcome than those who were treated by HVI. There was a rate of nonunion of 10% after ASF and 23% after HVI. Failure of reduction or fixation occurred in 11 patients (15%) but there was no significant difference between the two groups. Mortality rates were also similar: 9% (n = 3) after ASF and 8% (n = 4) after HVI. Conclusion. We conclude that ASF is the preferred method of treatment in this group of elderly patients, having a significantly higher rate of fusion, better clinical outcome and a similar rate of general and treatment-related complications. Cite this article: Bone Joint J 2016;98-B:1222–6


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 53 - 61
1 Jan 2024
Buckland AJ Huynh NV Menezes CM Cheng I Kwon B Protopsaltis T Braly BA Thomas JA

Aims

The aim of this study was to reassess the rate of neurological, psoas-related, and abdominal complications associated with L4-L5 lateral lumbar interbody fusion (LLIF) undertaken using a standardized preoperative assessment and surgical technique.

Methods

This was a multicentre retrospective study involving consecutively enrolled patients who underwent L4-L5 LLIF by seven surgeons at seven institutions in three countries over a five-year period. The demographic details of the patients and the details of the surgery, reoperations and complications, including femoral and non-femoral neuropraxia, thigh pain, weakness of hip flexion, and abdominal complications, were analyzed. Neurological and psoas-related complications attributed to LLIF or posterior instrumentation and persistent symptoms were recorded at one year postoperatively.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_15 | Pages 13 - 13
1 Oct 2014
Ohlin A Abul-Kasim K
Full Access

During the last decade or more, the anchors used for instrumentation in scoliosis surgery are predominantly transpedicular screws, according to Suk. The long term radiographical feature of screw fixation after scoliosis surgery is not previously studied. A consecutive series of 81 cases with AIS operated on with an all screw construct has been studied by means of low dose CT postoperatively and at 2 years postoperatively. There were 67 females and 14 males, with a mean age of 18.3 ± 3 years. In 26 / 81 (32 %) there were signs of loosing of one or more screws, at a maximum 3 screws. We observed loosened screws in the upper thoracic region in 16 cases, in the thoracolumbar 6 and in lumbar area in 4. Mean pre-op Cobb angle was 56 in cases of loosening and 53 of intact screw fixation (n.s.), the correction rate was 69% in loosened vs 70% among intact screws (n.s.). In males there were signs of loosening in 8/14 (57%) and in females 18/67 (27%). Among cases with loosening, 14% had suboptimal screw positioning postoperatively, in intact cases it was observed in 11% (n.s.). In the whole group there were signs of suboptimal screw positioning 12%. Clinically, 1 case had a loosened L4 screw replaced; and at all 21/26 had no complaints and 5/26 reported minor pain or discomfort. 1/26 had a minor proximal junctional kyphosis about 10°, in 3/26 there was a pull-out of some few mms. With plain radiography loosening could be observed in 11/26 cases; 5 were in the lumbar region. In a consecutive series of 81 adolescents with idiopathic scoliosis who had underwent scoliosis surgery according to Suk, one third showed, 2 years after the intervention, some minor screw loosening, assessed by low dose CT. One patient had one lumbar screw replaced and only 5 patients reported minor discomfort. Males were more prone to develop screw loosening


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXI | Pages 19 - 19
1 Jul 2012
Ohlin A
Full Access

Pedicle screws as the principal anchors of instrumentation in correction of scoliosis as described by Suk 15 years ago have now gained a wide acceptance among deformity surgeons. Pedicles in the concavity of the major as well as compensatory curves are often dysplastic making screw placement occasionally problematic. In cases of dural ectasia with dystrophic pedicles, the transpedicular screw anchorage is sometimes impossible. In 2009 Gardner et al. presented a case of NF-1 with a troublesome cervico-thoracic kyphosis where they created distal anchors by means of laminar screw fixation. In the presentation of this case, the idea is further developed. Case. A 14 year old girl without any obvious syndromic feature underwent surgery for a 70 degree thoracic scoliosis. A preoperatively MRI showed a dural ectasia. A preoperative low dose–CT revealed dystrophic pedicles from Th4 to L4, making transpedicular screw placement problematical. The operation was performed with the aid of an O-arm. At all levels from Th2 – L2 laminar screw fixation was used. Postoperatively, low-dose CT showed excellent screw positioning with the exceptiuon of one proximal screw which compromised a foramem but, without any symptoms. The postoperative course was quite uneventful and the patient was discharged at day 5days postoperatively. The correction rate was 70%. Conclusion. In cases of scoliosis with severe dystrophic pedicles, the use of laminar screws is a good alternative to problematic transpedicular screw placement


Bone & Joint Research
Vol. 12, Issue 4 | Pages 245 - 255
3 Apr 2023
Ryu S So J Ha Y Kuh S Chin D Kim K Cho Y Kim K

Aims

To determine the major risk factors for unplanned reoperations (UROs) following corrective surgery for adult spinal deformity (ASD) and their interactions, using machine learning-based prediction algorithms and game theory.

Methods

Patients who underwent surgery for ASD, with a minimum of two-year follow-up, were retrospectively reviewed. In total, 210 patients were included and randomly allocated into training (70% of the sample size) and test (the remaining 30%) sets to develop the machine learning algorithm. Risk factors were included in the analysis, along with clinical characteristics and parameters acquired through diagnostic radiology.


Aims

The optimal procedure for the treatment of ossification of the posterior longitudinal ligament (OPLL) remains controversial. The aim of this study was to compare the outcome of anterior cervical ossified posterior longitudinal ligament en bloc resection (ACOE) with posterior laminectomy and fusion with bone graft and internal fixation (PTLF) for the surgical management of patients with this condition.

Methods

Between July 2017 and July 2019, 40 patients with cervical OPLL were equally randomized to undergo surgery with an ACOE or a PTLF. The clinical and radiological results were compared between the two groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 64 - 64
1 Jun 2012
König MA Balamurali G Ebrahimi FV Grevitt MP Mehdian H Boszczyk BM
Full Access

Introduction. Recently published results suggest insertion of shorter screws in L5/S1 stand-alone anterior interbody fusion, fearing S1 nerve root violation. However, insertion of shorter screws led to screw fixation failure and new onset of S1 body fractures. Material and Methods. Retrospective review of patients with L5/S1 stand-alone anterior interbody fusion, focussing on screw length, radiological outcomes (especially metal work failure, screw fixation and S1 body fractures) and new onset of S1 nerve root irritation. Results. 38 patients were included (mean age 46.2±13.3 years, 21 females, 17 males). Fusion of the L5/S1 segment was performed in between 2003-2010; postoperative follow-up ranged from 2-24 months. 15 patients had multilevel surgery (7 multiple segmental fusion, 8 hybrid procedures). Screw length ranged from 20-30 mm. No patient had new postoperative S1 nerve root irritation. Interestingly, 2 patients out of the hybrid group had a new onset of L5 radiculopathy, concordant to the level of disc-replacement. Follow-up x-ray review showed no fracture of S1 body fractures in all patients. No evidence of screw loosening, migration or metal work failure was reported. Conclusion. In our opinion, this review showed that insertion of longer screws for stand-alone anterior interbody fusion in L5/S1 is safe. Longer screws offer better stabilization and seem to minimize risks like S1 body fractures. Short and long-term follow-ups were satisfactory regarding screw placement, migration and positioning of implants in all patients