Abstract
Introduction
Recently published results suggest insertion of shorter screws in L5/S1 stand-alone anterior interbody fusion, fearing S1 nerve root violation. However, insertion of shorter screws led to screw fixation failure and new onset of S1 body fractures.
Material and Methods
Retrospective review of patients with L5/S1 stand-alone anterior interbody fusion, focussing on screw length, radiological outcomes (especially metal work failure, screw fixation and S1 body fractures) and new onset of S1 nerve root irritation.
Results
38 patients were included (mean age 46.2±13.3 years, 21 females, 17 males). Fusion of the L5/S1 segment was performed in between 2003-2010; postoperative follow-up ranged from 2-24 months. 15 patients had multilevel surgery (7 multiple segmental fusion, 8 hybrid procedures). Screw length ranged from 20-30 mm.
No patient had new postoperative S1 nerve root irritation. Interestingly, 2 patients out of the hybrid group had a new onset of L5 radiculopathy, concordant to the level of disc-replacement.
Follow-up x-ray review showed no fracture of S1 body fractures in all patients. No evidence of screw loosening, migration or metal work failure was reported.
Conclusion
In our opinion, this review showed that insertion of longer screws for stand-alone anterior interbody fusion in L5/S1 is safe. Longer screws offer better stabilization and seem to minimize risks like S1 body fractures. Short and long-term follow-ups were satisfactory regarding screw placement, migration and positioning of implants in all patients.