Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 208 - 208
1 Jan 2013
Anupam K Tudu B Lamay B Maharaj R
Full Access

Background. Open fracture wounds are well known to be associated with infection & prolonged healing. Activity in scientific research to improve wound healing has often provided variable results. This study was done to question the de facto nature of Normal Saline as best irrigant in management of such wounds and to find out a better irrigant, if so, that does exist with due consideration to the mechanism by which saline dressings act. Material and methods. 30 patients with Grade 3 open fracture wounds were assessed over a period of three months according to Ganga Hospital Injury severity Score and were divided equally in study and control groups after adequate matching. A standard dressing protocol consisting of debridement and external fixation within 6 hours, avoidance of any antiseptic or surfactant agent, high-volume low-pressure pulsatile lavage irrigation and saline soaked gamgee pad packings with concerned solutions changed twice daily was done in respective groups. Follow-up was done by colour of healing granulation tissue, pus culture and soft tissue biopsy at Day 1, 3,7,10 & 14. Results. 6 out of 15(40%) wounds in study group were observed to have reached pink healthy granulation with low exudate by Day 14 as compared to only 3 out of 15(20%) in control group. The time taken to traverse from each stage of healing granulation was also observed to be smaller with 3% NaCl as compared to 0.9% NaCl. Although once healthy granulation stage was reached, further dressing with 3% NaCl in study group was shown to have worsening of granulation in about 33% of cases with none such observed in control. Conclusion. 3% NaCl is a better irrigant than 0.9% NaCl for dressing of Open trauma wounds during initial stages of dressing. Their effectivity in maintaining advanced granulation is although questionable, probably owing to its desiccative action


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 22 - 22
23 Feb 2023
Sandow M Cheng Z
Full Access

Arthroscopic electrosurgical tools for ablative, desiccating or coagulative effect are delivered as monopolar or bipolar probes. Monopolar electrosurgery delivers various profiles of heat energy directly to the tissue within a non-conductive irrigant (such as water or glycine) whereas bipolar electrosurgery creates an energy source by producing an electrical arc between the bipolar electrodes on the instrument head within an electro-conductive irrigation solution (saline) - and the heat generated is then transferred to the target tissues. This study investigated the heat generation within the simulated in-vitro test model to review the level of local heat production and potential local tissue heat. In a simulated In-vitro testing environment the local heat generation using bipolar or monopolar electrosurgical probes at standard power setting in either saline or water was tested, both touching and not touching a simulated tissue target, and for variable on-times. Monopolar generated relatively little heat when used in water and not touching the tissue. By contrast the bipolar wand generated potentially damaging local tissue temperature rises when used in saline and not touching the tissue. Both probes generated high local tissue heat when touching the tissue in their recommended irrigation solution. Monopolar electrosurgery delivered high localized temperature to the simulated tissue surface, but produced relatively little heat when not touching the tissue in a water solution. Bipolar however created high local temperature within the fluid adjacent to the probe irrespective if it was touching the tissue or not. Activation of the bipolar probe away from the tissue in saline irrigation may create a potential harmful temperature within the fluid medium without delivering therapeutic thermal effect to the target tissues. Monopolar electrosurgery appears to deliver a more controlled thermal effect, and only when in contact with the target tissues – potentially creating a reduced collateral thermal footprint


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 11 - 11
22 Nov 2024
Taltavull RO Goma-Camps MV Calderer LC Amat C Corona P
Full Access

Aim. This study aims to evaluate the effectiveness of a pre-formulated irrigation solution. 1. (containing ethanol, acetic acid, sodium acetate, benzalkonium chloride, and sterile water) compared to saline solution in managing acute periprosthetic joint infections (A-PJI) during Debridement, Antibiotic, and Implant Retention (DAIR) surgeries. The primary objective is to assess the healing rate using this solution. 1. versus saline in A-PJI patients, with “cure” defined by a set of criteria including no recurrence, wound issues, or need for ongoing suppressive antibiotics after 1 year. Principio del formularioFinal del formulario. Method. This single-center, randomized controlled trial will involve patients with acute periprosthetic infections undergoing standard DAIR surgery, divided into two groups: one receiving saline solution and the other receiving pre-formulated solution. 1. The study is single-blinded, with patients unaware of their group assignment. The study is registered at ISRCTN: https://doi.org/10.1186/ISRCTN10873696. Inclusion criteria include patients over 18 with hip or knee prostheses suffering from acute or hematogenous periprosthetic infections, while exclusion criteria include a history of prior debridement or multiple infected implants, among others. Principio del formularioFinal del formulario A total of 50 subjects are needed for statistical significance, with a 5% dropout rate anticipated. An interim safety analysis will assess early effectiveness and adverse effects, and the results are presented in this study. Data will be managed in online databases and analyzed using SPSS software, with a significance level of p<0.05. Results. Twenty-four patients were eligible for analysis, twelve in each group. The overall average age was 75 years, and the gender distribution was predominantly female (9 F and 3 M in each group). No significant differences were found at the baseline characteristics level between the two groups (p>0.05). The minimum follow-up of 1 year was achieved in all cases except three due to deaths not related to periprosthetic infection. Regarding efficacy, a non-statistically significant difference was observed (p>0.05), with 58% in the serum group and 42% in the pre-formulated irrigation solution. 1. group (X. 2. = 0.17, p=0.683). The average hospital stay was 38.42 days (SD 26.32) in the pre-formulated irrigation solution group. 1. and 24.42 days (SD 18.72) in the serum group, with this difference being not significant (t=1.5, p=0.148). Conclusions. While the current analysis indicates no significant differences between both groups in terms of efficacy, the study's ongoing progress and the inclusion of a larger sample size could potentially yield more definitive results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 22 - 22
24 Nov 2023
Jo S Chao C Khilnani T Bostrom M Carli A
Full Access

Aim. Polypropylene (PPE) synthetic mesh is increasingly used in knee arthroplasty surgery to salvage a disrupted extensor mechanism. Despite its clinical success, it is associated with a high rate of periprosthetic joint infection (PJI), which is hypothesized to be caused by bacterial biofilm. The purpose of the current study is to describe the progression of PPE-based biofilm formation over time and to determine if intraoperative antiseptic solutions could be used to effectively remove biofilm when treating PJI. Method. Commercially available knotted monofilament PPE mesh. 1. was cut into 10mm circular shape, immersed in tryptic soy broth (TSB) with methicillin-sensitive staphylococcus aureus and cultured individually in 48-well plates for 10 days to elucidate the biofilm grown on mesh over time. At every 24 hours, a triplicate of samples was retrieved and biofilm on the mesh was dislodged by sonicating at 52 kHz for 15 minutes and quantified by counting colony-forming units (CFUs) after overnight growth. The biofilm growth was also verified using scanning electron microscopy. The effect of saline and antiseptic solutions was verified by exposing 1) 0.05% chlorohexidine gluconate. 2. , 2) acetic acid-based mixture. 3. , 3) diluted povidone-iodine (0.35%), 4) undiluted povidone-iodine (10%). 4. , and 5) 1:1 combination of 10% povidone-iodine & 3% hydrogen peroxide on immature and mature biofilms for 3 minutes, created by culturing with bacteria for 24 hours and 72 hours respectively. All experiments were performed in quintuples and repeated. Antiseptic treatments that produced a three-log reduction in CFU counts compared to controls were considered clinically significant. Results. PPE-mesh produced reliable CFU counts at 24 hours and reached peak growth at 72 hours. For immature biofilm, all formulations of povidone-iodine produced significant reductions in CFU counts compared to controls. Although not meeting the established threshold, saline irrigation removed 86.5% of CFUs, while formulation based on chlorohexidine and acetic acid removed 99.2% and 99.7% respectively. For mature biofilm, formulations based on povidone-iodine and acetic acid produced significant reductions in CFU counts. Conclusions. Our findings suggest biofilm may form on mesh as early as 24 hours after bacterial exposure. Povidone-iodine formulations were consistently the most effective in removing biofilm on mesh surfaces. We recommend that surgeons consider using an antiseptic solution, preferably povidone-iodine-based, in addition to regular saline lavage when attempting to salvage a PPE mesh in the setting of PJI. 1. Marlex mesh (CR Bard, Davol Inc, Warwick, RI), . 2. Irrisept (Irrimax Corp, Gainesville, FL), . 3. Bactisure (Zimmer-Biomet, Warsaw, IN), . 4. Aplicare (Inc, Meriden, CT)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 29 - 29
1 Dec 2022
Alolabi B Shanthanna H Czuczman M Moisiuk P O'Hare T Khan M Forero M Davis K Moro JK Foster G Thabane L
Full Access

Interscalene brachial plexus block is the standard regional analgesic technique for shoulder surgery. Given its adverse effects, alternative techniques have been explored. Reports suggest that the erector spinae plane block may potentially provide effective analgesia following shoulder surgery. However, its analgesic efficacy for shoulder surgery compared with placebo or local anaesthetic infiltration has never been established. We conducted a randomised controlled trial to compare the analgesic efficacy of pre-operative T2 erector spinae plane block with peri-articular infiltration at the end of surgery. Sixty-two patients undergoing arthroscopic shoulder repair were randomly assigned to receive active erector spinae plane block with saline peri-articular injection (n = 31) or active peri-articular injection with saline erector spinae plane block (n = 31) in a blinded double-dummy design. Primary outcome was resting pain score in recovery. Secondary outcomes included pain scores with movement; opioid use; patient satisfaction; adverse effects in hospital; and outcomes at 24 h and 1 month. There was no difference in pain scores in recovery, with a median difference (95%CI) of 0.6 (-1.9-3.1), p = 0.65. Median postoperative oral morphine equivalent utilisation was significantly higher in the erector spinae plane group (21 mg vs. 12 mg; p = 0.028). Itching was observed in 10% of patients who received erector spinae plane block and there was no difference in the incidence of significant nausea and vomiting. Patient satisfaction scores, and pain scores and opioid use at 24 h were similar. At 1 month, six (peri-articular injection) and eight (erector spinae plane block) patients reported persistent pain. Erector spinae plane block was not superior to peri-articular injection for arthroscopic shoulder surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 78 - 78
24 Nov 2023
Bernaus M Carmona F De Espinosa Vázquez de Sola JML Valentí A Abizanda G Cabodevilla AR Torres D Calero JA Font L Del Pozo JL
Full Access

Aim. To provide proof of concept in an in vivo animal model for the prevention of prosthetic joint infection prevention using electric fields along with conventional antibiotic prophylaxis. Corresponding Author: Marti Bernaus. Method. First, we standardized the animal model to simulate implant contamination during the surgical procedure. We then implanted cobalt-chrome prostheses adapted to both knees of two New Zealand White rabbits, under standard aseptic measures and antibiotic prophylaxis with cefazolin. Prior to implantation, we immersed the prostheses in a 0.3 McFarland inoculum of S. aureus (ATCC 25923) for 30 seconds. In the first animal (control), the joint was directly closed after washing with saline. In the second animal (case), both prostheses were treated with electric current pulses for 30 seconds, washed with saline, and the joint was closed. After 72 hours, both animals were reoperated for the collection of periprosthetic tissue and bone samples, and prosthesis removal. In all samples, we performed quantitative cultures prior to vortexing and sonication, as well as prolonged cultures of the sonication broth. We confirmed the absence of contamination by identification with MALDI-TOF (VITEK-MS) and automated antibiotic susceptibility testing of the isolated colonies (VITEK-2). Results. In the “control” animal, we isolated S. aureus in all studied samples. The bacterial count expressed as log10 (cfu/cm2) in the prostheses of the right and left legs was 9.38 and 8.86, respectively. The bacterial count expressed as log10 (cfu/mL) in bone and periprosthetic tissue biopsies was 2.70 and 2.72 in the right leg and 3.24 and 3.87 in the left leg, respectively. In the “case” animal, where an electric field was applied to the implant after placement in addition to cefazolin prophylaxis, all samples (prosthesis, bone, and periprosthetic tissue) were negative, and no isolation of the inoculated strain of S. aureus was obtained after incubation of the sonication broth for 14 days. Conclusions. This in vivo model suggests the potential effectiveness of applying an electric field to a prosthetic implant in combination with cefazolin for the prevention of PJI development, after exposure of the implant to an inoculum of S. aureus (ATCC 25923). Our findings need to be confirmed using a larger sample size


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 16 - 16
24 Nov 2023
Siverino C Gens L Ernst M Buchholz T Windolf M Richards G Zeiter S Moriarty F
Full Access

Aim. Debridement, Antibiotics, Irrigation, and implant Retention (DAIR) is a surgical treatment protocol suitable for some patients with fracture related infection (FRI). Clinically relevant pre-clinical models of DAIR are scarce and none have been developed in large animals. Therefore, this project aimed to develop a large animal model for FRI including a DAIR approach and compare outcomes after 2 or 5 weeks of infection. Method. Swiss Alpine sheep (n=8), (2–6 years, 50–80 kg) were included in this study. This study was approved by cantonal Ethical authorities in Chur, Switzerland. A 2 mm osteotomy was created in the tibia and fixed with a 10-hole 5.5 mm steel plate. Subsequently, 2.5 mL of saline solution containing 10. 6. CFU/mL of Staphylococcus aureus MSSA (ATCC 25923) was added over the plate. Sheep were observed for 2 (n=3) or 5 weeks (n=5) until revision surgery, during which visibly infected or necrotic tissues were removed, and the wound flushed with saline. All samples were collected for bacterial quantification. After revision surgery, the sheep were treated systemically for 2 weeks with flucloxacillin and for 4 weeks with rifampicin and cotrimoxazole. After 2 further weeks off antibiotics, the animals were euthanized. Bacteriological culture was performed at the end of the study. Bone cores were isolated from the osteotomy site and processed for Giemsa & Eosin and Brown and Brenn staining. A radiographical examination was performed every second week. Results. Bacteriological evaluation of the retrieved samples during revision surgery showed no significant difference between the 2 vs 5 weeks infection periods in term of total CFU counts. At the end of the study, radiographical examination showed callus formation over the osteotomy site in both groups, although the osteotomy was not completely healed in either group. At euthanasia, the 2 weeks infection group showed a higher soft tissue burden compared to the 5 weeks group, whereby the infection in the 5 weeks group was primarily located in the bone and bone marrow. Conclusions. The large animal model of FRI and DAIR was successfully established. Bacteriological outcomes highlight that the increasing duration of the infection does not change the outcome but the location of the infection from a predominantly soft tissue infection to a deeper bone and intramedullary (IM) channel infection. The debridement of the IM channel could potentially reduce the infection burden by eliminating those bacteria not easily reached by systemic antibiotics, though is not practical using conventional techniques


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 73 - 73
1 Dec 2021
Cho J Goswami K Sukhonthamarn K Parvizi J Arnold W
Full Access

Aim. The efficacy of various irrigation solutions in removing microbial contamination of a surgical wound and reducing the rate of subsequent surgical site infection (SSI), has been demonstrated extensively. However, it is not known if irrigation solutions have any activity against established biofilm. This issue is pertinent as successful management of patients with periprosthetic joint infection (PJI) includes the ability to remove biofilm established on the surface of implants and necrotic tissues. The purpose of this study was to evaluate the efficacy of various irrigation solutions in eradicating established biofilm, as opposed to planktonic bacteria, in a validated in vitro model. Method. Established biofilms of Staphylococcus aureus and Escherichia coli were exposed to different irrigation solutions that included Polymyxin 500,000U/L plus bacitracin 50,000U/L, Vancomycin 1g/L, Gentamicin 80mg/L, Normal saline 0.9%, off-the-shelf Betadine 0.3%, Chlorhexidine 0.05%, Benzalkonium 1.3g/L, Sodium hypochlorite 0.125%, and Povidone-iodine 0.5%. Each experiment was conducted in a 96-well microtiter plate with a peg lid and standardized per the MBEC assay manufacturer's protocol. Following 2 minutes of solution exposure to the irrigation solution, residual biofilms were recovered by sonication. Outcome measures for antibiofilm efficacy were residual colony forming units (CFU) and optical density (690nm). Experiments were conducted in 24 replicates and the observations recorded by two blinded observers. Statistical analysis involved t-tests with Bonferonni adjustment. Results. Povidone-iodine 0.5%, Betadine 0.3%, Benzalkonium 1.3g/L, and Sodium hypochlorite 0.125% were significantly more efficacious against S.aureus biofilm versus all other solutions (p<0.001). Against E.coli biofilm, Povidone-iodine-0.5%, Benzalkonium-1.3g/L and Sodium hypochlorite-0.125% were also most effective compared to other irrigation solutions (p<0.001). Polymyxin-bacitracin, Gentamicin, Vancomycin, and Saline solutions had minimal activity against both E.coli and S.aureus biofilms (p<0.001). Similar trends were observed using both experimental endpoints (CFU and Turbidity) and both investigators (interrater reliability; r=0.99). Conclusion. This in vitro study observed that topical antibiotic solutions do not have any activity against established biofilms. Irrigations solutions containing adequate amount of povidone-iodine, betadine, sodium hypochlorite, and benzalkonium appear to have activity against established biofilm by gram positive and gram negative organisms. The use of these irrigation solutions may need to be considered in patients with established PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 12 - 12
22 Nov 2024
Wang L Trampuz A Zhang X
Full Access

Aim. Treatment of prosthetic joint infection (PJI) by systemic administration of high doses of long-term antibiotics often proves ineffective, causing severe side effects. Thus, we presented the phage Sb-1, which coding extracellular polymeric substances (EPS) degradation depolymerases, conjugated with rifampicin-loaded liposomes (Lip-RIF@Phage) by bio-orthogonal functionalization strategy to target biofilm (Figure1). Method. Methicillin-resistant Staphylococcus aureus (MRSA) biofilm was grown on porous glass beads for 24 h in vitro. After the biofilm formation, beads were exposed to 0.9% saline, then sonication. Quantitative and qualitative biofilm analyses were performed by colony counting, scanning electron microscopy and isothermal microcalorimetry. A rat model of total knee arthroplasty infected with the bioluminescent MRSA strain was developed as the PJI model to evaluate the efficacy of Lip-RIF@Phage anti-biofilm therapy in vivo, then the creatinine, alanine transaminase, and aspartate transaminase values were evaluated throughout the entire treatment process. Results. After treatment with Lip-RIF@Phage, no bacterial colonies were observed, consistent with findings from scanning electron microscopy. Similarly, isothermal microcalorimetry revealed no detectable heat following Lip-RIF@Phage treatment, aligning with these observations. In vivo experiments demonstrated a significant reduction in biofilm cell load compared to all other tested conditions, with no evidence of systemic toxicity on renal and liver functions attributed to Lip-RIF@Phage. Conclusions. The innovative depolymerase-phagobot nanosystem (Lip-RIF@Phage) exhibits remarkable efficacy in completely eliminating biofilm cells in vitro. It serves as an excellent carrier for antibiotic delivery, enhancing antibiotic penetration through biofilms and improving biofilm eradication efficacy. Furthermore, it enables personalized treatment strategies against biofilm-associated multidrug-resistant (MDR) infections by maximizing the effectiveness of any remaining sensitive antibiotics. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 18 - 18
10 May 2024
Joseph R Callon K Lin J Matthews B Irwin S Williams D Ashton N Crawford H Wen J Swift S Cornish J
Full Access

Introduction. Major trauma during military conflicts involve heavily contaminated open fractures. Staphylococcus aureus (S. aureus) commonly causes infection within a protective biofilm. Lactoferrin (Lf), a natural milk glycoprotein, chelates iron and releases bacteria from biofilms, complimenting antibiotics. This research developed a periprosthetic biofilm infection model in rodents to test an Lf based lavage/sustained local release formulation embedded in Stimulin beads. Method. Surgery was performed on adult rats and received systemic Flucloxacillin (Flu). The craniomedial tibia was exposed, drilled, then inoculated with S. aureus biofilm. A metal pin was placed within the medullary cavity and treatments conducted. Lf in lavage solutions: The defect was subject to 2× 50 mL lavage with 4 treatment groups (saline only, Lf only, Bactisure with Lf, Bactisure with saline). Lf embedded in Stimulin beads: 4 bead types were introduced (Stimulin only, Lf only, Flu only, Lf with Flu). At day 7, rats are processed for bioluminescent and X-ray imaging, and tibial explants/pins collected for bacterial enumeration (CFU). Results. Rats without treatments established a mean infection of 2×106 CFU/tibia. 4 treatment groups with a day 0, one-off lavage demonstrated >95% reduction in bacterial load 7 days post-op, with a reduction in CFU from 1×106/tibia down to 1×104/tibia. There was no statistically significant difference between each group (p = 0.55 with one way ANOVA). The stimulin bead experiments are ongoing and complete results will be obtained in the end of July. Conclusions. This research demonstrated a clinically relevant animal model of implanted metalware that establishes infection. No additional benefit was observed with a one-off, adjuvant Lf lavage during the initial decontamination of the surgical wound, compared with saline alone, and in combination with the antiseptic Bactisure. This animal model provides the foundation for future antibiofilm therapies


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 64 - 64
1 Dec 2022
Orloff LE Carsen S Imbeault P Benoit D
Full Access

Anterior cruciate ligament (ACL) injuries have been increasing, especially amongst adolescents. These injuries can increase the risk for early-onset knee osteoarthritis (OA). The consequences of late-stage knee OA include structural joint change, functional limitations and persistent pain. Interleukin-6 (IL-6) is a pro-inflammatory biomarker reflecting knee joint healing, and increasing evidence suggests that IL-6 may play a critical role in the development of pathological pain. The purpose of this study was to determine the relationship between subjective knee joint pain and function, and synovial fluid concentrations of the pro-inflammatory cytokine IL-6, in adolescents undergoing anterior cruciate ligament reconstruction surgery. Seven youth (12-17 yrs.) undergoing anterior cruciate ligament (ACL) reconstruction surgery participated in this study. They completed the Pedi International Knee Documentation Committee (Pedi-IKDC) questionnaire on knee joint pain and function. At the time of their ACL reconstruction surgery, synovial fluid samples were collected through aspiration to dryness with a syringe without saline flushing. IL-6 levels in synovial fluid (sf) were measured using enzyme linked immunosorbent assay. Spearman's rho correlation coefficient was used to determine the correlation between IL-6 levels and scores from the Pedi-IKDC questionnaire. There was a statistically significant correlation between sfIL-6 levels and the Pedi-IKDC Symptoms score (-.929, p=0.003). The correlations between sfIL-6 and Pedi-IKDC activity score (.546, p = .234) and between sfIL-6 and total Pedi-IKDC score (-.536, p = .215) were not statistically significant. This is the first study to evaluate IL-6 as a biomarker of knee joint healing in an adolescent population, reported a very strong correlation (-.929, p=0.003) between IL-6 in knee joint synovial fluid and a subjective questionnaire on knee joint pain. These findings provide preliminary scientific evidence regarding the relationship between knee joint pain, as determined by a validated questionnaire and the inflammatory and healing status of the patient's knee. This study provides a basis and justification for future longitudinal research on biomarkers of knee joint healing in patients throughout their recovery and rehabilitation process. Incorporating physiological and psychosocial variables to current return-to-activity (RTA) criteria has the potential to improve decision making for adolescents following ACL reconstruction to reduce premature RTA thereby reducing the risk of re-injury and risk of early-onset knee OA in adolescents


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 14 - 14
22 Nov 2024
Gómez MM Guembe M Díaz-Navarro M Peinado LP Matas-Díaz J Ruiz PS
Full Access

Aim. Chemical debridement is a fundamental step during Periprosthetic joint infection (PJI) surgery. Antiseptic solutions are commonly used, but evidence on the optimal antiseptic, concentration, and irrigation time is lacking. The aim of this study is to analyze and compare the anti-biofilm capacity of povidone iodine, H. 2. 0. 2. , acetic acid and Bactisure™ after different exposure times, as well as their combinations. Method. Surgical steel discs inoculated with methicillin susceptible (MSSA) and resistant S. aureus (MRSA), P. aeruginosa, and S. epidermidis were exposed to the following antiseptic solutions: 0.3% (PI0.3) and 10% povidone iodine (PI10), H. 2. 0. 2. , 3% Acetic acid (AA3) and Bactisure™. Combinations included AA3, H. 2. 0. 2. , and PI10 in various orders. Exposure time for the antiseptics solutions was 1, 3 and 5 minutes, while combinations had a 9-minute total exposure, 3 minutes per antiseptic sequentially. All experiments were performed in triplicate and with a sterile saline control. nThe reduction in colony-forming units (CFU) was measured after sonication, and biofilm structure was analyzed via scanning electron microscopy. Results. PI showed the highest antibiofilm activity. PI0.3 eradicated bacteria on the discs after 3 and 5 minutes of exposure, but only achieved a 77.1% reduction after 1 minute. After PI10 treatment, we did not recover any bacteria regardless of exposure time. H. 2. 0. 2. , AA3, and Bactisure™ reached a significantly lower bacterial decrease at all exposure times compared to PI0.3 and PI10. AA3 was less effective against MSSA and S. epidermidis. H. 2. 0. 2. showed less activity against MRSA than PI0.3, PI10, and Bactisure™. Combinations of antiseptics starting with AA3 showed the best results in terms of CFU reduction and cell viability. Conclusions. We propose a sequential combination of AA3 + H. 2. 0. 2. + PI10 with an exposure time of 9 minutes for the chemical debridement in PJI surgery. First, AA3 performs debridement and disruption of the biofilm. Then, H. 2. 0. 2. has a bactericidal effect and increases the porosity of the cell wall, and PI10 has a final bactericidal effect. If combinations are unavailable, PI is a cost-effective alternative


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 70 - 70
22 Nov 2024
Jacob A Onsea J Bessems L Spoormans P Vles G Metsemakers W Depypere M
Full Access

Aim. The primary objective is to evaluate the diagnostic performance of inoculating homogenized tissue and bone biopsies in blood culture bottles (BCB) for patients with (suspected) orthopaedic device-related infections. As secondary objective the time to positivity (TTP) of BCB and Wilkins-Chalgren broth (conventional method) will be evaluated. Method. Patients undergoing revision surgery due to suspected or proven fracture-related infection (FRI) or periprosthetic joint infection (PJI) according to respectively Consensus definition and EBJIS definition are included. 1,2. A minimal of three macroscopic infected/inflamed tissue/bone samples are collected in a container with saline and glass beads. 1.5 mL of the homogenized suspension is inoculated in BacT/ALERT FA and FN Plus bottles for 14 days. The remaining suspension is inoculated in Wilkins-Chalgren broth for 10 days and subcultured when cloudy or after 10 days. TTP is defined as the time until definite identification of the pathogen in the Laboratory Information System. Results. Up to now, 25 patients have been included, 11 (44%) had concordant results in BCB and the CM. In 11 patients cultures showed negative results for both methods. Three patients tested positive with BCB but remained negative with the same pathogen in CM. In the first patient, the CM failed to identify anaerobic bacteria (i.e. Fusobacterium nucleatum). In the second patient, three BCB were positive with Staphylococcus capitis. The third patient showed an infection with Escherichia coli, which was detected in all samples from the BCB, while all cultures obtained with the CM remained negative. A possible explanation for this discrepancy could be that this patient already received antibiotic therapy. BCB contain resins, which are capable of neutralizing antibiotic activity. Another case illustrating superiority of BCB involved an infection with Cutibacterium acnes, which showed positivity in six BCB, while only three were positive using the CM. We observed the shortest TTP with BCB. The median TTP of BCB was 32.0 hours (IQR 29.8) compared to a median TTP of 77.5 hours (IQR 107.6) when culturing with the CM. Contamination was seen in three patients with both methods, in eight patients contamination was only seen with the CM. For the remaining 14 patients no contamination was found. Conclusions. The results in this ongoing study indicate that the recovery of pathogens and TTP is better using BCB compared to CM. In addition, contamination occurs less frequently with the BCB method. Culturing tissue or bone biopsies in BCB seems a promising and faster detection method


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 21 - 21
24 Nov 2023
Hartmann KT Nielsen RL Mikkelsen F Ingmer H Kvich LA Aalbaek B Odgaard A Jensen HE Lichtenberg M Bjarnsholt T Jensen LK
Full Access

Aim. To make an inoculum for induction of Implant-Associated Osteomyelitis (IAO) in pigs based on bacterial aggregates resembling those found on the human skin, i.e. aggregates of 5–15 µm with low metabolic activity. The aggregates were evaluated and compared to a standard planktonic bacterial inoculum. Method. The porcine Staphylococcus aureus strain S54F9 was cultured in Tryptone Soya Broth for seven days. Subsequently, the culture was filtered through cell strainers with pore sizes of 15 µm and 5 µm, respectively. The fraction of 5–15 µm aggregates in the top of the 5 µm filter was collected as the aggregate-inoculum. The separation of aggregates into different size fractions was evaluated by light microscopy. The metabolism of the aggregate-inoculum and a standard overnight planktonic inoculum was evaluated with isothermal microcalorimetry. In total, six female minipigs were allocated into three groups (n=2), receiving different inoculums. Group A: overnight planktonic inoculum; 10. 4. CFU S. aureus (S54F9), Group B: seven days old 5–15 µm aggregate-inoculum; 10. 4. CFU S. aureus (S54F9), Group C: saline. All inoculums were placed in a pre-drilled implant cavity in the right tibia of the pig and a sterile stainless-steel implant was inserted. The pigs were euthanized seven days after surgery. Postmortem macroscopic pathology, microbiology, computed tomography and histopathology were performed. Results. The separation of aggregates into different size fractions was done successfully by the filtering method. Isothermal microcalorimetry showed, a delayed Time-to-peak metabolic activity of the aggregate-inoculum compared to the planktonic inoculum. S. aureus was isolated from subcutis, bone and implants from all animals in groups A and B. Both group A animals showed osteomyelitis at gross inspection with suppuration and sequestration, while groups B and C animals had no macroscopic lesions. From CT scans, both group A animals also showed positive signs of osteomyelitis, i.e., osteolysis, while only one animal in group B did, and none in group C. Histopathological examination of the bones showed more extensive inflammation in group A animals compared to those in group B, which showed more osteoid formation. Conclusions. Formation and separation of low metabolism bacterial aggregates into different size fractions was possible. The aggregates can be used as inoculum in the porcine IAO model, with microbiological re-isolation from both implants and tissue. Furthermore, the aggregates caused a less aggressive IAO, than the planktonic counterparts. Using aggregated bacteria as inoculum appears to be more relevant to the clinical situation of infecting bacteria


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 79 - 79
1 Oct 2022
Bernaus M Cubillos YL Soto S Bermúdez A Calero JA Torres D Veloso M Font-Vizcarra L
Full Access

Aim. To evaluate the efficiency of pulse lavage combined with electrical fields to remove biofilm from a metallic surface. Method. Using a 12-well culture plate designed for the application of electrical fields, strains of S. epidermidis were incubated at each well for 24 hours at 37ºC. After incubation, supernatant culture medium was removed, and each well was filled with 3ml of normal saline. Six different models were compared: a) control, b) low-pressure pulse lavage, c) high-pressure pulse lavage, d) pulsed electrical fields, e) low-pressure pulse lavage in combination with pulsed electrical fields, and f) high-pressure pulse lavage in combination with pulsed electrical fields. In all cases, exposure time was set to 25 seconds. In the electrical field models, 50 pulses were applied. After exposure, each bottom electrode was scraped carefully to release adhered bacteria. Subsequently, different dilutions of biofilm removed were spread onto Müller Hinton agar plates and incubated for 24h at 37 ºC, and colony-forming units (CFU) per milliliters were counted. Bacterial counts were then compared to the control model. Results. High-pressure pulse lavage combined with pulsed electrical fields showed the greatest biofilm removal with reductions of up to 11.9 logarithms when compared to the control group. The lowest reduction was achieved by low-pressure pulsed lavage (4.7 logs). All reductions showed statistically significant differences. Conclusion. The results of our comparative study between different models demonstrates high reduction rates for biofilm removal. Further in vivo studies are needed to evaluate the capacity of the combination of high-pressure pulse lavage with pulsed electrical fields in removing bacterial biofilm in real conditions


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 27 - 27
1 Dec 2022
Suter T Old J McRae S Woodmass J Marsh J Dubberley J MacDonald PB
Full Access

Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 5 - 5
1 Dec 2022
McRae S Suter T Old J Zhang Y Woodmass J Marsh J Dubberley J MacDonald P
Full Access

Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 22 - 22
1 May 2018
Penn-Barwell J Peleki A Chen Y Bishop J Midwinter M Rickard R
Full Access

We present the first systematic review conducted by the UK Defence Medical Services in conjunction with the Cochrane Collaboration. Irrigation fluids are used to remove contamination during the surgical treatment of traumatic wounds in order to prevent infection. This review aims to determine whether there is evidence that one wound irrigation fluid is superior to another at reducing infection. A pre-published methodology was used and two reviewers independently assessed the search results. The search produced 917 studies, of which three met the inclusion criteria. All were studies in open fractures, incorporating a total of 2,903 patients. Each RCT involved a distinct comparison, precluding meta-analysis: i) sterile saline vs. distilled/boiled water; ii) antibiotic solution vs. soap solution; iii) saline vs. soap solution. The odds ratios of infection following irrigation with various fluids was as follows: i) saline vs. distilled or boiled water 0.25 (95%CI 0.08–0.73); ii) antibiotic solution vs. soap 1.42 (95%CI 0.82–2.46); iii) saline vs. soap solution 1.00 (95%CI 0.80–1.26). These results suggest that neither soap nor antibiotic solution is superior to saline and that saline is inferior to distilled or boiled water


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 52 - 52
1 Oct 2022
Müller N Trampuz A Gonzalez-Moreno M
Full Access

Aim. The rise of multidrug-resistant bacteria and the decreasing efficacy of antibiotic therapy in successfully treating biofilm-associated infections are prompting the exploration of alternative treatment options. This study investigates the efficacy of different bioactive glass (BAG) formulations - alone or combined with vancomycin - to eradicate biofilm. Further, we study the influence of BAG on pH and osmotic pressure as important factors limiting bacterial growth. Method. Different BAG-S53P4 formulations were used for this study, including (a) BAG-powder (<45 μm), (b) BAG-granules (500–800 μm), (c) a cone-shaped BAG-scaffold and (d) two kinds of BAG-putty containing granules, with no powder (putty-A) or with additional powder (putty-B), and a synthetic binder. Inert glass beads were included as control. All formulations were tested in a concentration of 1750 g/ml in Müller-Hinton-Broth. Targeted bacteria included methicillin-resistant Staphylococcus aureus (MRSA) and epidermidis (MRSE). Vancomycin was tested at the minimum-inhibitory-concentration for each strain (1 µg/ml for MRSA; 2 μg/ml for MRSE). To investigate the antibiofilm effect of BAG alone or combined with vancomycin, 3 hour-old MRSA or MRSE biofilms were formed on porous glass beads and exposed to BAG ± vancomycin for 24h, 72h and 168h. After co-incubation, biofilm-beads were deep-washed in phosphate-buffered saline and placed in glass vials containing fresh medium. Recovering biofilm bacteria were detected by measuring growth-related heat production at 37°C for 24h by isothermal microcalorimetry. Changes in pH and osmotic pressure over time were assessed after co-incubation of each BAG formulation in Müller-Hinton-Broth for 0h, 24h, 72h and 168h. Results. All BAG formulations showed antibiofilm activity against MRSA and MRSE in a time-dependent manner, where longer incubation times revealed higher antibiofilm activity. BAG-powder and BAG-putty-B were the most effective formulations suppressing biofilm, followed by BAG-granules, BAG-scaffold and finally BAG-putty-A. The addition of vancomycin had no substantial impact on biofilm suppression. An increase in pH and osmotic pressure over time could be observed for all BAG formulations. BAG-powder reached the highest pH value of 12.5, whereas BAG-putty-A resulted in the lowest pH of 9. Both BAG-putty formulations displayed the greatest increase on osmotic pressure. Conclusions. BAG-S53P4 has demonstrated efficient biofilm suppression against MRSA and MRSE, especially in powder-containing formulations. Our data indicates no additional antibiofilm improvement with addition of vancomycin. Moreover, high pH appears to have a larger antimicrobial impact than high osmolarity. Acknowledgements. This work was supported by PRO-IMPLANT Foundation (Berlin, Germany). The tested materials were provided by Bonalive Biomaterials Ltd (Turku, Finland)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 30 - 30
1 Oct 2022
Jensen LK Jensen HE Blirup SA Bue M Hanberg P Soto S Aalbaek B Arkas M Vardavoulias M
Full Access

Aim. To develop a new system for antibacterial coating of joint prosthesis and osteosynthesis material. The new coating system was designed to release gentamicin immediately after insertion to eradicate surgical contamination. Method. Steel implants (2×15mm) were coated with a solid nanocomposite xerogel made from silica and the dendritic polymer, hyperbranched polyethyleneimine. The xerogel was anchored inside a porous surface made by pre-coating with titanium microspheres. Finally, gentamicin was encapsulated in the xerogel, i.e. no chemical binding. A total of 50 µg gentamicin was captured into each implant. The efficacy of the new coating was evaluated in a porcine model of implant associated osteomyelitis. In total, 30 female pigs were randomized into 3 study groups (n=10). Group A; plain implants + saline, Group B; plain implants + 10. 4. CFU of Staphylococcus aureus, and Group C; coated implants + 10. 4. CFU of S. aureus. Implant + inoculum was placed into a pre-drilled implant cavity of the right tibia and the pig was euthanized 5 days afterwards. Postmortem microbiology and pathology were performed. Two additional pigs were used in a pharmacokinetic study where microdialysis (MD) catheters were placed alongside coated implants. Extracellular fluid was sampled regularly for 24 hours from the MD catheters and analyzed for gentamicin content. Results. Within Groups A and C, all implants were found sterile by sonication and bacteria could not be identified within the surrounding bone tissue. In contrast, all Group B animals had S. aureus positive implant and tissue microbiology. Macroscopic and microscopic pathological examinations confirmed that Group A and C animals were complete identic, i.e. no pus around implants and only minor peri-implant inflammation related to insertion of implants per se. All Group B animals had pus around their implants and a massive peri-implant inflammatory response dominated by neutrophil granulocytes. Maximum gentamicin release (35 µg /mL) was measured in the first obtained MD sample, i.e. after 30 min, and the concentration stayed above the MIC level for the used S. aureus strain for 8 hours. Conclusions. The new xerogel coating prevented development of osteomyelitis. Prevention was due to a fast gentamicin release immediately following insertion and antimicrobial active concentrations were detectable several hours after implantation. This means that the critical time point of most relevant surgical procedures potentially could be protected by the novel coating. The new coating will be investigated on larger scale implants and full-size prosthesis in the future