First
Abstract. Purpose. Intracanal
Flail chest and multiple
High energy chest trauma resulting in flail chest injury is associated with increased rates of patient morbidity. Operative fixation of acute
To evaluate the efficacy of VEPTR in preventing further progression of scoliosis without impeding spinal growth in the treatment of children with progressive early onset scoliosis (EOS) without
Subjects. A prospective study of 127 patients who underwent posterior spinal arthrodesis and segmental spinal instrumentation with iliac crest bone graft for correction of adolescent idiopathic scoliosis. Patients were divided according to their Cobb angle into two groups. Group 1 (n= 78) with a Cobb angle > 70° who underwent an additional concave
Unstable chest wall injuries have high rates of mortality and morbidity. These injuries can lead to respiratory dysfunction, and are associated with high rates of pneumonia, sepsis, prolonged ICU stays, and increased health care costs. Numerous studies have demonstrated improved outcomes with surgical fixation compared to non-operative treatment. However, an adequately powered multi-centre randomized controlled study using modern fixation techniques has been lacking. We present a multi-centred, prospective, randomized controlled trial comparing surgical fixation of acute, unstable chest wall injuries with the current standard of non-operative management. Patients aged 16–85 with a flail chest (3 or more consecutive, segmental, displaced
Australian Football (AF) is a popular sport in Australia, with females now representing one-third of participants. Despite this, the injury profiles of females versus males in largely unknown. The current study investigated fractures, dislocations and tendon ruptures in females versus males presenting to emergency departments (ED) with an AF injury. All patients, regardless of age, presenting to one of 10 EDs in Victoria, Australia, with an AF injury were included. Data were prospectively collected over a 10-month period, coinciding with a complete AF season. Data were extracted from patient medical records regarding injury-type, body-part injured and treatments required. Female and male data were compared with chi-squared tests. Of the 1635 patients presenting with an AF injury, 595 (36.0%) had a fracture, dislocation or tendon rupture, of whom 85 (14.3%) were female and the average age was 20.5 years (SD 8.0). Fractures accounted for most injuries (n=478, 80.3% of patients had a fracture), followed by dislocations (n=118, 19.8%) and tendon ruptures (n=14, 2.4%). Upper limb fractures were more common than lower limb fractures (71.1% v 11.5% of fractures). Females were more likely to fracture their hands or fingers than males (45.7% v 34.3%). Males were more likely to fracture
There has been a substantial increase in the surgical treatment of unstable chest wall injuries recently. While a variety of fixation methods exist, most surgeons have used plate and screw fixation. Rib-specific locking plate systems are available, however evidence supporting their use over less-expensive, conventional plate systems (such as pelvic reconstruction plates) is lacking. We sought to address this by comparing outcomes between locking plates and non-locking plates in a cohort of patients from a prior randomized trial who received surgical stabilization of their unstable chest wall injury. We used data from the surgical group of a previous multi-centred, prospective, randomized controlled trial comparing surgical fixation of acute, unstable chest wall injuries to non-operative management. In this substudy, our primary outcome was hardware-related complications and re-operation. Secondary outcomes included ventilator free days (VFDs) in the first 28 days following injury, length of ICU and hospital stay, and general health outcomes (SF-36 Physical Component Summary (PCS) and Mental Component Summary (MCS) scores). Categorical variables are reported as frequency counts and percentages and the two groups were compared using Fisher's Exact test. Continuous data are reported as median and interquartile range and the two groups were compared using the Wilcoxon rank-sum test. From the original cohort of 207 patients, 108 had been treated surgically and had data available on the type of plate construct used. Fifty-nine patients (55%) had received fixation with non-locking plates (primarily 3.5 or 2.7 mm pelvic reconstruction plates) and 49 (45%) had received fixation with locking plates (primarily rib-specific locking plates). The two groups were similar in regard to baseline and injury characteristics. In the non-locking group, 15% of patients (9/59) had evidence of hardware loosening versus 4% (2/49 patients) in the locking group (p = 0.1). The rate of re-operation for hardware complications was 3% in the non-locking group versus 0% in the locking group (p = 0.5). No patients in either group required revision fixation for loss of reduction or nonunion. There were no differences between the groups with regard to VFDs (26.3 [19.6 – 28] vs. 27.3 [18.3 – 28], p = 0.83), length of ICU stay (6.5 [2.0 – 13.1] vs 4.1 [0 – 11], p = 0.12), length of hospital stay (17 [10 – 32] vs. 17 [10 – 24], p = 0.94) or SF-36 PCS (40.9 [33.6 – 51.0] vs 43.4 [34.1 – 49.6], p = 0.93) or MCS scores (47.8 [36.9 – 57.9] vs 46.9 [40.5 – 57.4], p = 0.95). We found no statistically significant differences in outcomes between patients who received surgical stabilization of their unstable chest wall injury when comparing non-locking plates versus locking plates. However, the rate of hardware loosening was nearly 4 times higher in the non-locking plate group and trended towards statistical significance, although re-operation related to this was less frequent. This finding is not surprising, given the inherent challenges of
Abstract. In the pediatric population, scoliosis is classified into congenital, syndromic, idiopathic, and neuromuscular in aetiology. Syndromic scoliosis represents a wide range of systemic anomalies associated with scoliosis. The primary challenge for a clinician is to think beyond the scoliotic curve, as the underlying pathology is multisystemic. The aim of this review is to identify the systemic anomalies, associated with syndromic scoliosis. MEDLINE, EMBASE, and CINAHL databases were searched, dating from 1990–2020, relevant to the purpose of our study. Keywords used: “scoliosis”+ “syndrome” + “genetic”. Retrospective, prospective studies were included. Case reports that had fewer than 4 patients were not included. Delineating 60 articles, we found a total of 41 syndromes to be associated with scoliosis. Thoracic region was the most common level of scoliosis curve, being noted in 28 syndromes. Mental retardation, seizures, and ataxia were the commonly noticed CNS anomalies. VSD, ASD, and TGA were the anomalies associated with CVS; Hypotonia,
The purpose of this study was to determine if the use of a new 4 Dimensional CT scan aids the clinician in defining the size and area of the scapular bone to be removed arthroscopically in patients with Snapping Scapular Syndrome. From January 2009 – January 2011 nine consecutive patients with Snapping Scapular Syndrome were included. In six patients, (mean age 21±5 years, range 15–27) conservative treatment failed. These patients were positioned prone and demonstrated their snapping motion during the 7 seconds duration of the scan. The 4D CT machine scans 16 cm volumes in 0.3 seconds. It also scans motion, allowing a 3D reconstruction of the scapulothoracic joint, its’ movements and the dynamic area of impingement of the scapula on the surrounding structures. This scan has already improved arthroscopic removal of the supero-medial angle of the scapula. The scan showed in one case not only snapping of the superior medial angle of the scapula on the 2nd
Introduction. Originally, the vertical expandable titanium
Objectives. Surgical treatment is standard for advanced osteochondritis dissecans (OCD) of the humeral capitellum. When cartilage is seen to be separated or completely detached, this fragment fixation is not usually applied. There have been reports of cases in which advanced OCD of the humeral capitellum progressed to osteoarthritis (Fig), particularly in cases which involved the lateral wall. In these cases, every attempt should be made to reconstruct the lateral wall to avoid osteoarthritis. In this study, we followed up cases with
Cementless stem fixation is a widely used method of stem revision in North America and elsewhere in the world. There is abundant literature in its support. Most of the reports from 1985 to 2005 related to proximally or extensively porocoated designs, the former falling into disfavor with time because of unpredictable outcomes. With few exceptions (e.g. S-ROM) the modularity of these designs was limited to the head/neck junction. But this generation of designs was associated with some issues such as insertional fractures, limited control of anteversion (and risk of dislocation), limited applicability in the setting of severe bone loss (Paprosky Type 4 osteolysis or Vancouver Type B3 periprosthetic fracture), as well as ongoing concern relating to severe proximal stress shielding. In the past decade we have seen the mounting use of a new design concept: tapered fluted titanium stems (TFTS), which incorporate the advantages of titanium (for less flexural rigidity), conical taper (for vertical taper-lock stability), longitudinal
Introduction. Hip-Spine syndrome has various clinical aspects. For example, schoolchild with severe congenital dislocation of the hip have unfavorable standing posture and disadvantageous motions in ADL. Hip-Spine syndrome is closely related closely as the adjacent lumbar vertebrae and the hip joint. Furthermore, not only the pelvis and the lumbar spine, but also the neck position might influence on the maximum hip flexion angle. In this study, we examined the maximum hip flexion angle and pelvic movement angle by observing the lumbar spine, the pelvis and the neck in three different positions. Subjects and Methods. The participants were five healthy volunteers (three males and two females) and ranged in age from 16 to 49 years. We measured the hip flexion angle (=∠X) and the pelvic tilt angle (=∠Y), using Zebris WinData and putting the six markers on skin. The positions of the marker are Femur lateral condyle (M1), Greater trochanter (M2), Lateral margin of 10th
Retroversion, also referred to as posterior wear of the glenoid, can make resurfacing the glenoid challenging. However, careful pre-operative planning with three dimensional CT scanning can allow central placement of the glenoid component through removal of some of the anterior bone to allow contained placement and secure fixation within the glenoid vault. Since the scapula is not a fixed skeletal structure and moves substantially on the chest wall, the actual degree of posterior wear (retroversion) frequently is the result of extraneous biomechanical forces and structures. For example, the degree of kyphosis and shape of the
Cementless stem fixation is a widely used method of stem revision in North America and elsewhere in the world. There is abundant literature in its support. Most of the reports from 1985 to 2005 related to proximally or extensively porocoated designs, the former falling into disfavor with time because of unpredictable outcomes. With few exceptions (eg S-ROM) the modularity of these designs was limited to the head/neck junction. But this generation of designs was associated with some issues such as insertional fractures, limited control of anteversion (and risk of dislocation), limited applicability in the setting of severe bone loss (Paprosky Type 4 osteolysis or Vancouver Type B3 periprosthetic fracture), as well as ongoing concern relating to severe proximal stress shielding. In the past decade we have seen the mounting use of a new design concept: tapered fluted titanium stems (TFTS), which incorporate the advantages of titanium (for less flexural rigidity), conical taper (for vertical taper-lock stability), longitudinal
Failure of the femoral component after a primary or revision THA is commonly associated with some degree of femoral bone loss. Depending on the quantity and quality of the remaining host bone, femoral stem revision can be challenging. Twenty patients with severe proximal femoral bone loss due to prosthetic loosening were treated by Wagner cementless self-locking revision stems with a mean follow up of 24 months (range 18–36 months). The indication of revision surgery was aseptic loosening in 16 patients and septic loosening in 4 cases. At the end of the follow up the mean Harris hip score increased from 35 to 86 points. Definite radiographic evidence of bone regeneration in the bony defects was achieved within 3 months in all patients. Implantation of a Wagner cementless selflocking revision stem provided satisfactory results. The Wagner SL Revision prosthesis, firmly and rotationally stable fixed in the medullary cavity of the healthy bone distal from the original prosthetic bed, with its conical longitudinal
OBJECTIVE OF THE STUDY. The objective of this study is to establish the medium-term clinical and radiological results with the cementless three-dimensional Vektor-Titan stem compared with conventional cementless stem, such as PerFix stem. The latter stem has a double-wedge design with a rounded distal portion for canal filling (Fig. 1). MATERIALS AND METHODS. From July, 2004, to May, 2010, fifty seven Vektor-Titan stems and 150 PerFix stems were implanted for the patients with osteoarthritis, avascular necrosis, femoral neck fracture, and rheumatoid arthritis in our hospital. The results were evaluated clinically using Japanese Orthopedic Association (JOA) scores and the Merle d’Aubigne and Postel (M&P) scores. Radiographs were analyzed retrospectively. The criteria used for determining loosening were migration or a total radiolucent zone between the prosthesis/bone cement and host bone, wherein the width increased progressively or change of position, i.e., migration or subsidence of the prosthesis. Migration of the socket seen on the radiograph was defined as either the presence of a ≥2-mm position change or rotation. Position changes of the stem seen on the radiograph were defined as the presence of a progressive subsidence of ≥2 mm or change of position, e.g., varus or valgus. The follow-up period was 9.2 ± 2.6 (range, 5.0–14.0) years. RESULTS. One patient had intraoperative femoral shaft fracture and healed by conservative treatment. The mean JOA and M&P scores improved from preoperative 39.3 and 6.8 points to postoperative 90.9 and 17.2 points, respectively. Thigh pain was less frequent for Vektor-Titan stems (Table 1). Radiolucent lines was far less likely to appear for Vektor-Titan stems evaluated by Gruen's zonal analyses (Table 2). On the other hand, there were radiolucent zones of more than 90% in zone 4 with cementless PerFix stems (Table 2). There was no cases of loosening or postoperative infection. Although signs of bone atrophy were found in the proximal femur and the trochanters in 66.7 % of all cases, bone structure was radiologically normal without stress shielding in most cases (Table 2). On the contrary, there was evidence of an even denser bone structure, such as trabeculae, at the tip of the stem and the lateral implant fixation within the greater trochanter in Vektor-Titan stem cases. These findings remained unchanged over observation periods. DISCUSSION AND CONCLUSIONS. The cementless Vektor-Titan stem is made of Ti6AI7Nb, has got the shape of a straight three-dimensional cone. It has a high proximal volume in the form of a three-dimensional taper with longitudinal
Introduction. Although total hip replacement (THR) has been described as the operation of the century, there is still room for improvement. There is therefore continued effort for advanced implants and bearing surfaces, moreover so, for the younger patient with a longer life expectancy and increased needs. Objectives. This prospective case-series study aims to present the preliminary, minimum three-years, results of a novel uncemeted stem, the Leader StemÒ (Vadin Implants Ltd, London, U.K.). The Leader StemÒ is a titanium, tapered stem for immediate three-point fixation. There is a metaphyseal porous-coating with titanium microspheres for bone in-growth. It has anti-rotational