Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 38 - 38
10 Feb 2023
Batinica B Bolam S Zhu M D'Arcy M Peterson R Young S Monk A Munro J
Full Access

Little information exists regarding optimal tibial stem usage in revision total knee arthroplasty (rTKA) utilising a tibial trabecular metal (TM) cone. The purpose of this study was to compare 1) functional outcomes, 2) radiographic outcomes, and 3) implant survivorship in rTKA utilising TM cones combined with either short stems (SS) or long stems (LS) at minimum two-years clinical follow-up. In this retrospective, multi-centre study, patients undergoing TM cone utilising rTKA between 2008 and 2019 were included. Patients were divided into: SS group (no diaphyseal engagement), and LS group (diaphyseal engagement). All relevant clinical charts and post-operative radiographs were examined. Oxford Knee Score (OKS) and EuroQol-5D (EQ-5D-5L) data were collected at most recent follow-up. In total, 44 patients were included: 18 in the SS group and 26 in the LS group. The mean time of follow-up was 4.0 years. Failure free survival was 94.5% for the SS group and 92.3% for the LS group. All failures were for prosthetic joint infections managed with debridement, antibiotics, and implant retention. At most recent follow-up, 3 patients demonstrated radiographic signs of lucency (1 SS 2 LS, p = 1) and the mean OKS were 37 ± 4 and 36 ± 6 (p = 0.73) in the SS and LS groups, respectively. Tibial SS combined with TM cones performed as well as LS in rTKA at minimum two-years follow-up. A tibial SS in combination with a TM cone is a reliable technique to achieve stable and durable fixation in rTKA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 14 - 14
10 Feb 2023
Vertesich K Staats K Böhler C Koza R Lass R Giurea A
Full Access

The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Aim of this study was to investigate long term results of a new RH prosthesis (EnduRo®, B Braun, Germany), which uses carbon-fiber reinforced poly-ether-ether-ketone (CFR PEEK) as a new bearing material, first time used in knee arthroplasty. Fifty-six consecutive patients, who received the EnduRo® RH prosthesis were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. Min. Follow up was 7 and mean follow up 9,3 years. Clinical examination included Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and range of motion (ROM). Competing risk analysis was assessed for survival with respect to indication and failure mode. KSS, WOMAC, OKS, and ROM significantly improved from the preoperative to the follow up investigations (p < 0.0001). There was no difference in clinical outcome between the primary and the revision group. The overall cumulative incidence for revision for any reason was 23.6% and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). The evaluated RH prosthesis provided reliable and durable results with a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of cases. The use of this RH system in primary patients showed high survival rates. Long-term functional and clinical results proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 100 - 100
10 Feb 2023
Mactier L Baker M Twiggs J Miles B Negus J
Full Access

A primary goal of revision Total Knee Arthroplasty (rTKA) is restoration of the Joint Line (JL) and Posterior Condylar Offsets (PCO). The presence of a native contralateral joint allows JL and PCO to be inferred in a way that could account for patient-specific anatomical variations more accurately than current techniques. This study assesses bilateral distal femoral symmetry in the context of defining targets for restoration of JL and PCO in rTKA. 566 pre-operative CTs for bilateral TKAs were segmented and landmarked by two engineers. Landmarks were taken on both femurs at the medial and lateral epicondyles, distal and posterior condyles and hip and femoral centres. These landmarks were used to calculate the distal and posterior offsets on the medial and lateral sides (MDO, MPO, LDO, LPO respectively), the lateral distal femoral angle (LDFA), TEA to PCA angle (TEAtoPCA) and anatomic to mechanical axis angle (AAtoMA). Mean bilateral differences in these measures were calculated and cases were categorised according to the amount of asymmetry. The database analysed included 54.9% (311) females with a mean population age of 68.8 (±7.8) years. The mean bilateral difference for each measure was: LDFA 1.4° (±1.0), TEAtoPCA 1.3° (±0.9), AAtoMA 0.5° (±0.5), MDO 1.4mm (±1.1), MPO 1.0mm (±0.8). The categorisation of asymmetry for each measure was: LDFA had 39.9% of cases with <1° bilateral difference and 92.4% with <3° bilateral difference, TEAtoPCA had 45.8% <1° and 96.6% <3°, AAtoMA had 85.7% <1° and 99.8% <3°, MDO had 46.2% <1mm and 90.3% <3mm, MPO had 57.0% <1mm and 97.9% <3mm. This study presents evidence supporting bilateral distal femoral symmetry. Using the contralateral anatomy to obtain estimates for JL and PCO in rTKA may result in improvements in intraoperative accuracy compared to current techniques and a more patient specific solution to operative planning


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 2 - 2
1 Mar 2021
Higuera-Rueda C Emara A Nieves-Malloure Y Klika AK Cooper H Cross M Guild G Nam D Nett M Scuderi G Cushner F Silverman R
Full Access

Aim. This was a multicenter, randomized, clinical trial to compare the 90-day 1) incidence of surgical site complications (SSC); 2) health care utilization (the number of dressing changes, readmission, and reoperation); and 3) the patient-reported outcomes (PRO) in high-risk patients undergoing revision total knee arthroplasty (rTKA) with postoperative closed incision negative pressure wound therapy (ciNPT) versus a standard of care (SOC) silver-impregnated occlusive dressing. Method. A total of 294 rTKA patients (15 centers) at high-risk for wound complications were prospectively randomized to receive either SOC or ciNPT (n = 147 each). The ciNPT system was adjusted at 125 mmHg of suction. Investigated outcomes were assessed weekly up to 90 days after surgery. A preset interim analysis was conducted at 50% of the intended sample size, with planned discontinuation for clear efficacy/harm if a significance of p < 0.005 was attained. Results. A total of 242 patients completed the required follow-up (ciNPT: n = 124 (84.4%); SOC: n = 118 (80.3%)). Demographics, baseline comorbidities, causes of revision (prosthetic joint infection, aseptic loosening, implant-related, and periprosthetic fractures), and duration of treatment were similar in both cohorts (p > 0.05). Intention to treat analysis demonstrated lower rates of SSC with ciNPT (3.4%) compared to SOC (14.3%) (p = 0.0013) (Table 1 – not included in the proceeding). Similar outcomes were obtained with the modified intention to treat analysis (p = 0.0013). The ciNPT cohort exhibited lower readmission rates (p = 0.0208), and number of dressing changes (p = 0.0003). Conversely, differences in the 90-day incidence of SSI and measured patient-reported outcomes did not reach statistical significance (p > 0.05). Conclusions. ciNPT mitigates the risk of SSC and readmission among high-risk rTKA patients. The lower frequency of dressing changes within the ciNPT cohort may provide added value for healthcare utilization without compromising pain and function. For the table, please contact authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 44 - 44
1 Feb 2021
Edwards T Patel A Szyszka B Coombs A Kucheria R Cobb J Logishetty K
Full Access

Background. Revision total knee arthroplasty (rTKA) is a high stakes procedure with complex equipment and multiple steps. For rTKA using the ATTUNE system revising femoral and tibial components with sleeves and stems, there are over 240 pieces of equipment that require correct assembly at the appropriate time. Due to changing teams, work rotas, and the infrequency of rTKR, scrub nurses may encounter these operations infrequently and often rely heavily on company representatives to guide them. In turn, this delays and interrupts surgical efficiency and can result in error. This study investigates the impact of a fully immersive virtual reality (VR) curriculum on training scrub nurses in technical skills and knowledge of performing a complex rTKA, to improve efficiency and reduce error. Method. Ten orthopaedic scrub nurses were recruited and trained in four VR sessions over a 4-week period. Each VR session involved a guided mode, where participants were taught the steps of rTKA surgery by the simulator in a simulated operating theatre. The latter 3 sessions involved a guided mode followed by an unguided VR assessment. Outcome measures in the unguided assessment were related to procedural sequence, duration of surgery and efficiency of movement. Transfer of skills was assessed during a pre-training and post-training assessment, where participants completed multi-step instrument selection and assembly using the real equipment. A pre and post-training questionnaire assessed the participants knowledge, confidence and anxiety. Results. All participants reported orthopaedics as their primary speciality with mean of 6-years experience. 80% reported they are ‘sometimes’ required to scrub for operations in which they do not feel comfortable with the equipment. All participants improved across the 3 unguided sessions reducing their operative time by 47%, assistive prompts by 75%, dominant hand motion by 28% and head motion by 36%. This transferred into the real-world: Participants completed 11.3% of tasks correctly in pre-training compared to 83.5% correct in the timely selection and assembly of rTKA equipment, post-training. All participants reported increased confidence and reduced anxiety after the training. Conclusion. Unfamiliarity with orthopaedic procedures or equipment is common for scrub nurses and can impact surgical performance. VR training improves their understanding, technical skills and efficiency in complex rTKA. These VR-learnt skills translate into the physical environment. This has important implications on how scrub nurses can be trained remotely, asynchronously and safely to perform complex orthopaedic surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 106 - 106
1 Jul 2020
Dion C Lanting B Howard J Teeter M Willing R
Full Access

During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium alloy (Ti6Al4V) revision augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of rTKA with this augment in comparison to conventional cemented rTKA. Eleven pairs of thawed fresh-frozen cadaveric tibias (22 tibias) were potted in custom fixtures. Primary total knee arthroplasty (pTKA) surgery was performed on all tibias. Fixation stability testing was conducted using a three-stage eccentric loading protocol. Static eccentric (70% medial/ 30% lateral) loading of 2100 N was applied to the implants before and after subjecting them to 5×103 loading cycles of 700 N at 2 Hz using a joint motion simulator. Bone-implant micromotion was measured using a high-resolution optical system. The pTKA were removed. The proximal tibial bone defect was measured. One tibia from each pair was randomly allocated to the experimental group, and rTKA was performed with a titanium augment printed using selective laser melting. The contralateral side was assigned to the control group (revision with fully cemented stems). The three-stage eccentric loading protocol was used to test the revision TKAs. Independent t-tests were used to compare the micromotion between the two groups. After revision TKA, the mean micromotion was 23.1μm ± 26.2μm in the control group and 12.9μm ± 22.2μm in the experimental group. There was significantly less micromotion in the experimental group (p= 0.04). Prior to revision surgery, the control and experimental group had no significant difference in primary TKA micromotion (p= 0.19) and tibial bone loss (p= 0.37). This study suggests that early fixation stability of revision TKA with the novel 3D printed titanium augment is significantly better then the conventional fully cemented rTKA. The early press-fit fixation of the augment is likely sufficient for promoting bony ingrowth of the augment in vivo. Further studies are needed to investigate the long-term in-vivo fixation of the novel 3D printed augment


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 61 - 61
1 Aug 2020
Jean P Belzile E Pelet S Caron J
Full Access

Over the last decade, the number of total knee arthroplasty (TKA) has risen over 125%. Numerous studies have established a relationship between obesity and complications in primary TKA. Interestingly, few studies have investigated medical and orthopaedic complications in obese patients undergoing revision TKA (RTKA). With the increasing number of RTKA and with the prevalence of obesity still on the rise, the study of obesity on complications following RTKA is indicated. We retrospectively reviewed 180 RTKA performed by a single surgeon done between August 2008 and June 2017. All patients who underwent RTKA were included, but revisions done with simultaneous extensor mechanism reconstruction and/or distal femur replacement were excluded since these procedures are technically more demanding. 154 revisions met our inclusion/exclusion criteriaes and were included in the final analysis. 81 patients were included in the non-obese group (BMI . The total number of orthopaedic complications in the obese group (46.6%) was significantly higher than in the non-obese group (27.2%) (OR=1.71) (p = 0.01). The number of infection was higher in the obese group (11%) than in the non-obese (6.2%) but this was not statistically significant (OR=1.77) (p = 0.28). Reoperation rate was also higher in the obese group (23.3%) than in the non-obese group (16%) but this did not reach statistical significance (OR=1.46) (p = 0.26) (Table 3). Medical complications were higher in the obese group (31.5% vs 19.8%) (OR=1.59) (p=0.09). According to the Dindo-Clavien classification, the obese group demonstrated a significantly higher rate of grade 3 or higher complications (p = 0.01). Obesity significantly increases the occurrence of orthopaedic complications following RTKA. Obesity also seems to increase the number of medical complications following RTKA. The obese patient should be informed prior to revision TKA that there is an increased risk of complications when compared with the non-obese patient. Further research with higher power would seem advisable to confirm this trend. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 101 - 101
1 Apr 2019
Eymir M Unver B Karatosun V
Full Access

Background. Revision total knee arthroplasties (rTKA) are performed with increasing frequency due to the increasing numbers of primary arthroplasties, but very little is known regarding the influence of muscle strength impairments on functional limitations in this population. Objectives. The aim of this study was to assess relationship between muscle strength and functional level in patient with rTKA. Design and Methods. Twenty-three patients (8 males, 15 females) were included in the study with mean age 68.4±10 years. Patients performed 3 performance tests (50-Step Walking Test, 10 Meter Walk Test, 30-Second Chair-Stand Test), and one self-report test (HSS) were preferred to assess patients. The maximum isometric muscle strength of quadriceps femoris and hamstring muscles of all the patients was measured using Hand-Held Dynamometer (HHD). Results. While moderate-to-strong significant correlations was found between quadriceps femoris muscle strength and 30- Second Chair-Stand Test (r=0.390, p=0.049), 50-Step Walking Test (r=−0.530, p=0.005), 10 Meter Walk Test (r=−0.587, p=0.002), there were not significant correlation between HSS knee score and all performance-based tests (p>0.05). Also there were not significant correlation between hamstring muscle strength and all other measurement tests (p>0.05). Conclusion. The moderate-to-strong statistical significant correlation between quadriceps femoris muscle strength and functional performance tests suggests that improved postoperative quadriceps strengthening could be important to enhance the potential benefits of rTKA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 42 - 42
1 Dec 2018
Glehr M Klim S Amerstorfer F Bernhardt G Sadoghi P Gruber G Leithner A Radl R
Full Access

Aim. Bone loss is a severe problem in septic revision total knee arthroplasty (RTKA). The use of porous coated metaphyseal sleeves is a promising treatment option for extended bone defects. The currently published mid-term results remain limited and no study has been focused exclusively on septic cases. Our aim was to determine the implant survivorship (with special focus on osseointegration) and the clinical and radiological mid-term outcome of metaphyseal sleeve fixation in septic RTKA surgery (minimum follow-up of 2 years). Method. Between January 2005 and September 2015, 57 patients underwent septic RTKA surgery using metaphyseal sleeves. In 56 patients (98,2 %) who underwent a total of 69 two stage revision procedures, clinical and radiological follow-up examinations were conducted. One patient (1,8 %) was lost to follow-up. The examinations included the American Knee Society Score (KSS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the SF-36 Health survey as well as radiographic measurement to determine if successful osseointegration had been achieved. Results. Thirteen knees (18.8%) had to be re-revised at the time of follow-up (mean 5.3 years, min. 2 – max. 11.2), all due to reinfection (Figure 1). We did not encounter any cases of aseptic loosening. The mean range of motion (92° ± 21°), SSS (7 ± 2), KSS (76 ± 19), WOMAC (70 ± 20), SF-36 MCS (55 ± 14) and SF-36 PCS (35 ± 9) have shown satisfying results. Conclusions. Metaphyseal sleeves have shown very promising mid-term results regarding clinical scores, osseointegration, and aseptic loosening. Our results are the first analysing the performance of metaphyseal sleeves in exclusively septic cases and show that they are a reliable fixation option in septic RTKA patients with severe bone loss


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 58 - 58
1 Apr 2019
Dharia M Armacost J Son Y
Full Access

INTRODUCTION. Porous metal bone fillers are frequently used to manage bony defects encountered in revision total knee arthroplasty (rTKA). Compared to structural graft, porous metal bone fillers have shown significantly lower loosening and failure rates potentially due to osseointegration and increased material strength [1]. The strength of porous metal bone fillers used in lower extremities is frequently assessed using compression/shear/torsion test methods, adapted from spine standards. However, these basic methods may lack clinical relevance, and do not provide any insight on the relationship between patient activity and anticipated prosthesis performance. The goal of this study was to evaluate the response of bone fillers under different activities of daily living, in order to define physiologically relevant worst case biomechanics for component evaluation. METHODS. A bone filler tibial augment is shown in Figure 1. A test construct for tibial augments (half-block each for medial and lateral sides) is shown in Figure 2, along with compatible rTKA components. An additional void in the bone was filled using bone cement. Loading was applied through the tibiofemoral contact patches created on polyethylene tibial insert. Loading was used for two activities of daily living; walking and deep knee bend [2–3]. During walking, the tibiofemoral contact patch on the anterior tibial post gets loaded due to femoral hyperextension with 1.2xbody weight (BW), whereas the medial and lateral condyles get loaded with 3xBW compressive load. For deep knee bend, only the condyles get loaded with 4.34xBW. Compared to walking, 45% higher compressive load magnitude in deep knee bend located further posterior was anticipated to create a larger bending moment and induce higher stress on the half augments. A finite element analysis (FEA) was performed by modeling this test construct with a medium size tibial augment. All components were modeled using linear elastic material properties. All interfaces, including the augment-bone interface (representing full bony ingrowth construct) were modeled using bonded contact. The inferior surface of the bone analogue was constrained. Linear static analyses were performed and peak von mises stress predicted in the tibial augments was compared between activities. RESULTS. Deep knee bend resulted in 31% higher stresses in the tibial augments than for walking. High von mises stresses were mostly predicted at the superior/posterior aspect of the internal side of the augment and in the corners of the cutouts. Figure 3 presents the von mises stresses in the tibial augments for both loading scenarios. DISCUSSION. This study revealed that the 45% increased posterior compressive load associated with deep knee bend is a more significant factor than the moment applied to the post during walking gait for a hyperextended knee, when considering the stress in bone filler augments in revision TKA. The stress in the augments can depend on multiple factors and the proposed FEA method can be used to compare stresses in different porous material bone fillers to determine worst case for assessing its strength


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 45 - 45
1 Dec 2017
Glehr M Klim S Sadoghi P Bernhardt G Leithner A Radl R Amerstorfer F
Full Access

Aim. One of the most challenging problems in total knee arthroplasty (TKA) is periprosthetic infection. A major problem that arises in septic revision TKA (RTKA) are extended bone defects. In case of extended bone defects revision prostheses with metaphyseal sleeves are used. Only a few studies have been published on the use of metaphyseal sleeves in RTKA - none were septic exclusive. The aim of our study was to determine the implant survival, achieved osseointegration as well as the radiological mid-term outcomes of metaphyseal sleeve fixation in septic two-stage knee revision surgery. Method. Clinical and radiological follow-up examinations were performed in 49 patients (25 male and 24 female). All patients were treated with a two-stage procedure, using a temporary non-articulating bone cement spacer. The spacer was explanted after a median of 12 weeks (SD 5, min. 1 – max. 31) and reimplantation was performed, using metaphyseal sleeves in combination with stem fixation. Bone defects were classified on preoperative radiographs using the Anderson Orthopaedic Research Institute (AORI) classification. During follow-up postoperative range of motion (ROM) was measured and radiographs were performed to analyse: (i) osseointegration (radiolucent lines and spot welds), (ii) leg alignment, (iii) patella tilt and shift. Results. All types of bone defects were found on the tibial (4× type 1, 7× type 2a, 26× type 2b, 9× type 3) as well as on the femoral side (1× type 1, 4× type 2a, 20× type 2b, 6× type 3). Mean follow-up time was 4.7 years (minimum 1 year). In total 12 knees (24.5%) had to be re-revised, all due to re-infection. We did not encounter any case of aseptic loosening. In 3 patients (6.8%) we detected an insufficient osseointegration, but no patient had to be re-revised due to only minimal or to the absence of symptoms and no clinical signs of loosening. The ROM (mean 93°, SD 20.6, min. 25° max. 125°) has shown very satisfying results at the time of follow-up. Malalignment was detected in 4 patients (10.3%), a patella tilt in 7 (19.4%) and a patella shift in 14 (48.3%). Conclusions. Metaphyseal Sleeves have shown very promising mid-term results regarding osseointegration and aseptic implant survival in RTKA with compromised metaphyseal bone stock. Our results indicate that they are a reliable fixation option in septic RTKA patients


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 55 - 55
1 Feb 2017
Brozyniak C Hitt K Della Valle C Campbell D
Full Access

INTRODUCTION. As the demographic of the patient population requiring revision total knee arthroplasty (rTKA) continues to expand, varying preoperative conditions and activity levels need to be taken into consideration when analyzing postoperative outcomes. Factoring in preoperative activity levels can help manage the expectations of patients. The purpose of this study was to analyze the outcomes of low and high activity patients receiving a contemporary rTKA. METHODS. One hundred and eighty rTKA patients enrolled in a prospective, multicenter study were evaluated through 2 years postoperative. Patients were divided into groups based on preoperative activity level using the Lower Extremity Activity Scale (LEAS). Patients scoring between 1–7 were classified as ‘Low Activity’ (LA, N=104) and patients scoring 8–18 were classified as ‘High Activity’ (HA, N=76). Clinical and patient-reported outcomes were evaluated, with an additional quality of life analysis completed utilizing SF-6D scores obtained by transforming SF-36 scores through a method described by Brazier et al. and analyzed for effect size. RESULTS. No differences were seen in age or BMI between the groups, with more females in the LA group (64%) and majority males in the HA group (58%). Both groups displayed statistically significant improvements through 2 years; however the degree of improvement varied based on outcome measure. Postoperative improvement in both groups were similar in the KSS, but patients in the LA group showed larger increases in the KSS Functional assessment at 6 weeks and 2 years (Figure 1). The effect of rTKA was analyzed through an SF-6D analysis (Figure 2). There was a statistically significant large effect seen in the LA group at 1 year (0.96), which was in conjunction with a higher SF-6D outcome (Figure 2). CONCLUSION. The current study population displayed significant improvement in functional patient outcomes following rTKA regardless of preoperative activity level and function. Patients with lower preoperative activity levels demonstrated not only greater cumulative functional improvements, but also had significant improvements in quality of life following rTKA. This suggests that the preoperative lower activity level may be in part related to the poorly functioning knee and that revision surgery has the potential to improve overall activity levels and function


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 146 - 146
1 Jan 2016
Lee MC Lee S Park IW Ro DH Kim KB Chung KY Seong SC
Full Access

Purpose. Although the use of stems in revision total knee arthroplasty (RTKA) enhances survival by improving the stability of implant, questions as to the optimal fixation method as well as the vertical extent of the cement, remain unanswered. This study aimed 1) to determine the correlation between the vertical extent of cement and implant loosening; and 2) to determine the minimum cementing extent for a stable implant in revision TKA with a hybrid technique. Materials and Methods. We retrospectively analyzed 109 stemmed RTKAs with average follow-up of 63 months. In each case, a single varus-valgus constrained implant was used and fixed with a hybrid technique. During surgery, stem was partially covered with cement beyond stem-implant junction. Stability of implant was evaluated according to the modified Knee Society Radiographic Scoring System. Cementing extent was defined as length from implant base to the end of the radiopaque line around the stem. The correlation between the vertical cementing extent and implant stability was analyzed, and the minimal vertical cementing extent for a stable implant was evaluated with a scatter plot. Results. The vertical cementing extent was longer in stable implants (femur: P=.002, tibia:P=.007) and the correlation between the vertical cementing extent and implant stability was significant (femur:P<.001, tibia:P=.001). Logistic regression analysis found that the risk of loosening was 8.7 times higher if the cementing extent was less than 40mm (tibia=16.1 times). The minimal vertical cementing extent for a stable implant in femur was estimated to be 65mm for middle stem (40% of total implant length) and 50mm for long stem (25% of total implant length). For tibia, it was 55mm for middle stem (45% of total implant length) and 40mm for long stem (25% of total implant length). Conclusion. We confirmed that a negative correlation exists between the radiolucent line and the cementing extent in stemmed revision TKA with a hybrid fixation technique. We could expect a durable implant in revision TKA with a minimal vertical cementing extents and it was 65mm for the femur and 55mm for the tibia. Level of Evidence. IV, Cases series