Femoral impaction bone grafting (IBG) may be used to restore bone stock in
This study aimed to quantify self-reported outcomes and walking gait biomechanics in patients following primary and revision THA. The specific goals of this study were to investigate: (i) if primary and revision THA patients have comparable preoperative outcomes; and (2) if revision THA patients have worse postoperative outcomes than primary THA patients. Forty-three patients undergoing primary THA for osteoarthritis and 23 patients undergoing revision THA were recruited and followed longitudinally for their first 12 postoperative months. Reasons for revision were loosening (73%), dislocation (9%), and infection (18%). Patients completed the Hip dysfunction and Osteoarthritis Outcome Score (HOOS), and underwent gait analysis preoperatively, and at 3 and 12 months postoperatively. A 10 camera motion analysis system (V5 Vantage, Vicon, UK) recorded marker trajectories (100 Hz) during walking at self- selected speeds. A generic lower-body musculoskeletal model (Gait2392) was scaled using principal component analysis [1] and the inverse kinematics tool in Opensim 3.3 was used to compute joint angles for the lower limbs in the sagittal plane. Independent samples t-test were used to compare patient reported outcomes between the primary and revision groups at each timepoint. Statistical parametric mapping was used to compare gait patterns between the two groups at each timepoint. Preoperatively, patients undergoing primary THA reported significantly worse pain (p<0.001), symptoms (p<0.001), function (p<0.001), and quality of life (p=0.004). No differences were observed at 3 and 12 months postoperatively between patients who had received a primary or revision THA. The only observed difference in gait pattern was that patients with a revision THA had reduced hip extension at 3 months, but no differences were observed preoperatively and 12 months. Despite the suggestions in the literature that revision THA is bound to have worse outcomes compared to primary THA, we found no differences in in patient-reported outcomes and gait patterns at 12 months postoperatively. This suggests that it may be possible, in some circumstances, for patients following revision THA to achieve similar outcomes to their peers undergoing primary THA.
Repeat revision hip replacements can lead to severe bone loss necessitating salvage procedures such as proximal or total femoral replacement. We present medium term outcomes from our experience of the Limb Preservation System (LPS) in patients with failed revision hip arthroplasties. All patients undergoing proximal femoral or total femoral replacement from 2003–2007 at our unit were reviewed. Data was collected preoperatively and at annual assessment post procedure for a minimum of 5 years. This included clinical review, functional outcome scores (WOMAC, Oxford Hip Score, Harris Hip Score) and radiographic evaluation. A total of 17 patients underwent femoral replacement (13 proximal, 4 total) using the LPS during the study period. Within this cohort there were 13 males and 4 females with a mean age of 64 years (range 47–86). Median follow up was 7 years (range 5–9 years). Primary diagnoses were DDH (7), Primary OA (5), RA (2), proximal femoral fracture (2) and phocomelia (1). Five patients (29%) required further revision surgery for infection (2 patients) or recurrent dislocations (3 patients). No stems required revision due to aseptic loosening or stem failure at 5–9 years. Compared to preoperative assessment, there was significant improvement in median outcome scores at 5 years (WOMAC increased by 33 points, Oxford hip score by16 points and Harris hip score by 43 points). 82% of patients maintained functional independence at latest review. The Limb Preservation System offers a salvage procedure for failed
We performed 83 consecutive cemented
Total hip arthroplasty is well established as a successful treatment modality for end stage arthritis, with a variety of components currently available. However, utilising traditional stemmed implants in patients with distorted proximal femoral geometry can be technically challenging with increased risk of complications. We present seven patients with distorted proximal femoral anatomy or failed hip arthroplasty in whom a technically challenging primary or revision operation was simplified by use of a Proxima stem. This is a short, stemless, metaphyseal loading implant with a pronounced lateral flare. At twelve months follow up there have been no complications with average improvement in Oxford and Harris scores of forty and forty-nine respectively. Radiological analysis shows all stems to be stable and well fixed. Designed primarily as a bone conserving implant for primary hip arthroplasty we propose that the Proxima prosthesis also be considered in cases where a conventional stemmed implant may not be suitable due to challenging proximal femoral anatomy. The use of the stemless Proxima implant provided a simple solution in seven difficult and potentially lengthy complex primary and revision hip arthroplasties with gratifying clinical and radiological outcomes.
We used a biodegradable mesh to convert an acetabular defect into a contained defect in six patients at total hip replacement. Their mean age was 61 years (46 to 69). The mean follow-up was 32 months (19 to 50). Before clinical use, the strength retention and hydrolytic in vitro degradation properties of the implants were studied in the laboratory over a two-year period. A successful clinical outcome was determined by the radiological findings and the Harris hip score. All the patients had a satisfactory outcome and no mechanical failures or other complications were observed. No protrusion of any of the impacted grafts was observed beyond the mesh. According to our preliminary laboratory and clinical results the biodegradable mesh is suitable for augmenting uncontained acetabular defects in which the primary stability of the implanted acetabular component is provided by the host bone. In the case of defects of the acetabular floor this new application provides a safe method of preventing graft material from protruding excessively into the pelvis and the mesh seems to tolerate bone-impaction grafting in selected patients with primary and
Background. Over 96% of primary total hip replacements (THR) recorded in the National Joint Registry (NJR) are performed through a posterior or lateral surgical approach. There is no high quality evidence available to support the use of one approach over the other in primary THR and even less evidence when the outcome of revision THR is considered. Methods. Questionnaires were sent to 267 patients who had revision hip replacements between January 2006 and March 2010 for aseptic loosening. They rated their pain from 0–10, and used the Self-Administered Patient Satisfaction Scale (SAPS), Oxford Hip Score (OHS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and Short form-12 (SF-12). Results. We performed 275
Background. Hip resurfacing has resurged in the last decade due to a renewed interest in metal on metal bearing. One of the proposed advantages is ease of revision of the femoral component. Short term functional results after femoral revision are similar to those after conventional total hip replacement. Survival and function after revision of the acetabular component only or of both components have not been reported. We aimed to assess hip function and implant survival after revision of the acetabular component for failed Birmingham hip resurfacing (BHR). Methods. The Oswestry Outcome Centre collected data prospectively on 5000 patients who underwent hip resurfacing between 1997 and 2002. Of these, 182 hips were revised: 42% had revision of the femoral component only, 8% revision of the acetabular component only, and 50% revision of both components. This study analyzed patients who had revision of the acetabular component, either in isolation or in combination with the femoral component. Results. In the isolated acetabular revision group the median Harris Hip Score was 74 at a mean of 4.5 years post-revision. In the both components revision group the median Harris hip score was 85 at a mean of 4 years. There was no significant difference in function between the groups. Kaplan-Meier survivor ship analysis after revision showed an average survival of 91% at 10 years. There was a significant difference between survival of isolated acetabular revision (75%) and both component revision (96%). Conclusions.
Rivaroxaban has been recommended for routine use as a thromboprophylactic agent in patients undergoing lower-limb arthroplasty. Starting January 2011, our unit has converted from aspirin to Rivaroxaban use routinely following lower-limb arthroplasty for venous thromboembolism (VTE) prophylaxis. The aim of this audit was to retrospectively review its efficacy and the morbidity associated with its use. All patients undergoing primary and revision lower-limb arthroplasty between February 2011 and July 2011 were reviewed. All patients undergoing total knee replacement surgery and total hip replacement surgery received oral rivaroxaban 10 mg daily post-operatively for 14 days and 35 days respectively. Outcome measures recorded were; investigation for DVT/PE, rate of DVT/PE, wound complications (infection, dehiscence, leaking, bleeding), blood transfusion rate and readmission rate within 6 weeks of surgery. Of the 162 patients identified, 19 were excluded due to insufficient information or because they did not receive rivaroxaban as VTE prophylaxis. 141 patients (mean age 71.7 years) were included. 69 primary and 5 revision total knee replacements were performed. 60 primary and 7
Ten acetabular cups coated with hydroxyapatite (HA) had originally been inserted in five primary and five
The use of impacted, morsellised bone grafts has become popular in
The role of bone-graft extenders in impaction revision surgery is becoming increasingly important. Tricalcium phosphate and hydroxyapatite have been shown to be both biocompatible and osteoconductive, yet many surgeons remain reluctant to use them. The difficulty in handling bone-graft extenders can be partly alleviated by using porous particles and adding clotted blood. In an Our findings showed that pure allograft bone particles had significantly higher cohesion than when mixed with extender (p <
0.001). Washing had no effect on cohesion. The addition of clotted blood significantly increased the cohesion of both pure bone (p <
0.019) and mixes with pure bone and with porous graft extender (p <
0.044).