Aims. The aim of this study was to assess the incidence the microbiological spectrum and clinical outcome of hip and knee revision arthroplasties with unexpected-positive-intraoperative-cultures (UPIC) at a single center with minimum follow up of 2 years. Methods. We retrospectively analyzed our prospectively maintained institutional arthroplasty registry. Between 2011 and 2020 we performed presumably aseptic rTHA (n=939) and
Background. Obesity has been linked with increased rates of knee osteoarthritis. Limited information is available on the survival and functional outcome results of rTKR in the obese patients. This registry-based study aimed to identify whether BMI is an independent risk factor for poorer functional outcomes and /or implant survival in
Little information exists regarding optimal tibial stem usage in revision total knee arthroplasty (rTKA) utilising a tibial trabecular metal (TM) cone. The purpose of this study was to compare 1) functional outcomes, 2) radiographic outcomes, and 3) implant survivorship in
Aim. It still remains unclear whether postoperative antibiotic treatment is advantageous in presumed aseptic revision-arthroplasties of the hip (rTHA) and knee (rTKA) with unexpected-positive-intraoperative-cultures (UPIC). The aim of this study was to evaluate if there is a difference in the septic and/or aseptic re-revision rate in patients with or without postoperative antibiotics. Method. In this retrospective propensity-score (PS) matched cohort-study we compared the re-revision rate and the microbiological spectrum in rTHA and
Over the last decade, the number of total knee arthroplasty (TKA) has risen over 125%. Numerous studies have established a relationship between obesity and complications in primary TKA. Interestingly, few studies have investigated medical and orthopaedic complications in obese patients undergoing revision TKA (RTKA). With the increasing number of
Background. Revision total knee arthroplasty (rTKA) is a high stakes procedure with complex equipment and multiple steps. For
A primary goal of revision Total Knee Arthroplasty (rTKA) is restoration of the Joint Line (JL) and Posterior Condylar Offsets (PCO). The presence of a native contralateral joint allows JL and PCO to be inferred in a way that could account for patient-specific anatomical variations more accurately than current techniques. This study assesses bilateral distal femoral symmetry in the context of defining targets for restoration of JL and PCO in
Introduction. The purpose of this study is to compare total and rate of caloric energy expenditure between conventional and robotic-arm assisted total knee arthroplasty (TKA) between a high volume “veteran” surgeon (HV) and a lower volume, less experienced surgeon (LV). Methods. Two specialized arthroplasty surgeons wore a biometric-enabled shirt and energy expenditure outcomes were measured (total caloric expenditure, kilocalories per minute, heart rate variability, and surgical duration) during 35 conventional (CTKA) and 29 robotic primary total knee arthroplasty (RTKA) procedures. Results. Overall, the rate of caloric expenditure was similar between
Purpose. Unexpected-positive-intraoperative-cultures (UPIC) in presumed aseptic revision-total-knee-arthroplasties (rTKA) are common, and the clinical significance is not entirely clear. In contrast, in some presumably septic
During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium alloy (Ti6Al4V) revision augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of
INTRODUCTION. As the demographic of the patient population requiring revision total knee arthroplasty (rTKA) continues to expand, varying preoperative conditions and activity levels need to be taken into consideration when analyzing postoperative outcomes. Factoring in preoperative activity levels can help manage the expectations of patients. The purpose of this study was to analyze the outcomes of low and high activity patients receiving a contemporary
Aim. This was a multicenter, randomized, clinical trial to compare the 90-day 1) incidence of surgical site complications (SSC); 2) health care utilization (the number of dressing changes, readmission, and reoperation); and 3) the patient-reported outcomes (PRO) in high-risk patients undergoing revision total knee arthroplasty (rTKA) with postoperative closed incision negative pressure wound therapy (ciNPT) versus a standard of care (SOC) silver-impregnated occlusive dressing. Method. A total of 294
Aim. Serum parameters continue to be a focus of research in diagnosing periprosthetic joint infections (PJI). Several workgroups have recently proposed serum Albumin-Globulin-Ratio (AGR) as a potential new biomarker. Due to controversies in the literature, its usability in clinical practice remains uncertain. The aim of this study was to assess the value of serum AGR in diagnosing PJI preoperatively, especially in comparison with the well-established marker C-reactive Protein (CRP). Method. From January 2015 to June 2022, patients with indicated revision hip (rTHA) and knee (rTKA) arthroplasty were included in this retrospective cohort study of prospectively collected data. A standardized diagnostic workup was performed using the 2021 European Bone and Joint Infection Society (EBJIS) definition of PJI, excluding CRP. Diagnostic accuracies of serum AGR and CRP were calculated by receiver operating characteristic curve (ROC) analysis. A z-test was used to compare the area under the curves (AUC). Results. A total of 275 patients with rTHA and
Aim. Bone loss is a severe problem in septic revision total knee arthroplasty (RTKA). The use of porous coated metaphyseal sleeves is a promising treatment option for extended bone defects. The currently published mid-term results remain limited and no study has been focused exclusively on septic cases. Our aim was to determine the implant survivorship (with special focus on osseointegration) and the clinical and radiological mid-term outcome of metaphyseal sleeve fixation in septic
Aim. One of the most challenging problems in total knee arthroplasty (TKA) is periprosthetic infection. A major problem that arises in septic revision TKA (RTKA) are extended bone defects. In case of extended bone defects revision prostheses with metaphyseal sleeves are used. Only a few studies have been published on the use of metaphyseal sleeves in
Background. Revision total knee arthroplasties (rTKA) are performed with increasing frequency due to the increasing numbers of primary arthroplasties, but very little is known regarding the influence of muscle strength impairments on functional limitations in this population. Objectives. The aim of this study was to assess relationship between muscle strength and functional level in patient with
Aim. Despite several synovial fluid biomarkers for diagnosis of periprosthetic joint infection (PJI) have being investigated, point-of-care (POC) tests using these biomarkers are not widely available. Synovial calprotectin has recently been reported to effectively exclude diagnosis of PJI and a novel lateral flow POC test using it has shown potential to be effective. Thus, the aims of this study were to 1) validate calprotectin POC with enzyme linked immunosorbet assay (ELISA) 2) at 2 separate thresholds for PJI diagnosis in total knee arthroplasty (TKA) patients using the 2013 Musculoskeletal Infection Society (MSIS) PJI diagnosis criteria as the gold standard. Method. Intraoperative synovial fluid samples were prospectively collected from 123 patients who underwent revision TKAs (rTKA) at two academic hospitals within the same healthcare system from October 2018 to January 2020. The study was conducted under IRB approval. Included patients followed the hospital standard for their PJI diagnostic work-up. Data collection included demographic, clinical, and laboratory data in compliance with MSIS criteria. Synovial fluid samples were analysed by calprotectin POC and ELISA tests in accordance with manufacturer's instructions. Patients were categorized as septic or aseptic using MSIS criteria by two independent reviewers blinded to calprotectin assay results. The calprotectin POC and ELISA test performance characteristics were calculated with sensitivities, specificities, positive, and negative predicted values (PPV and NPV, respectively) and areas under the curve (AUC) for 2 different PJI diagnosis scenarios: (1) a threshold of >50 mg/L and (2) a threshold of >14 mg/L. Results. According to MSIS criteria, 53 rTKAs were septic while 70
INTRODUCTION. Porous metal bone fillers are frequently used to manage bony defects encountered in revision total knee arthroplasty (rTKA). Compared to structural graft, porous metal bone fillers have shown significantly lower loosening and failure rates potentially due to osseointegration and increased material strength [1]. The strength of porous metal bone fillers used in lower extremities is frequently assessed using compression/shear/torsion test methods, adapted from spine standards. However, these basic methods may lack clinical relevance, and do not provide any insight on the relationship between patient activity and anticipated prosthesis performance. The goal of this study was to evaluate the response of bone fillers under different activities of daily living, in order to define physiologically relevant worst case biomechanics for component evaluation. METHODS. A bone filler tibial augment is shown in Figure 1. A test construct for tibial augments (half-block each for medial and lateral sides) is shown in Figure 2, along with compatible
INTRODUCTION. The functional and anatomical results of TKA revisions are less good than a primary TKA. The TKA revision frequency increases and we must improve our surgeries and prepare the next standard of these surgeries. The aim of this study was to evaluate the CAOS / one stage strategie to treat the knee PJIs. MATERIALS. In this prospective study, between September 2011 and December 2014, 41 patients treated for chronic knee PJI in a one stage revision. For all of them, an imageless CAOS system (ExactechGPS, Blue- Ortho, Gieres) was used. A personalised profile of revision was created. All surgeries were performed with the same protocole and by using the same Optetrak CC knee components (Exactech, Gainesville, FL). All operations were performed by a single senior surgeon. Indications for the revision TKA were (1) revision of a primary TKA or unicondylar knee arthroplasty (n=27) or (2) revision of revisionTKA (n=15). The measurement of the HKA angle, the Oxford score and the ROM were evaluated pre and post- operatively. RESULTS. 27 males and 14 females with an average age of 71 years old (55–87) were treated for a PIJ (1 unicompartimental prosthesis, 26 TKA and 15 RTKA). The mean follow-up was 41 months (30 months − 6 years). The average time of surgery was 135 mn (120–195) for an average hospitalisation duration of 10 days (7–16). No postoperative outliers were reported (mean preop.: −1,6°+/_−5,1° − Post- op. −0,3°+/_ −1,4°). The average ROM were 115° (90–130°) (Fig. 1). The rate of success for the infection was 92,7%. We report no specific CAS complications and all the navigations were finalised. In this series of complex cases, the rate of infection healing is 92,7%. DISCUSSION. Using CAOS is a safe option with no specific complication. Combined with one stage procedures, it should be an optimal medico-economical strategy for Knee revisions. This first series initiated the « GPS
Introduction. It is well established that diabetic patients undergoing total knee arthroplasty (TKA) are more susceptible to infection, problematic wound healing, and have overall higher complication rates. However there is a paucity in current literature investigating the effects of hypoglycemia on TKA. The purpose of this study was to determine the effect of hypoglycemia on TKA revision (rTKA) incidence analyzing a national private payer database for procedures performed between 2007 and 2015 Q1. Methods. A retrospective review of a national private payer database within the PearlDiver Supercomputer application (Warsaw, IN, USA) for patients undergoing TKA with blood glucose levels ranging from 20 to 219 mg/ml, in increments of 10 mg/ml, was conducted. Patients who underwent TKA were identified by Current Procedural Terminology (CPT)-27447 and International Classification of Disease (ICD) code 81.54. Glucose ranges were identified by filtering for lab identifier values unique to the PearlDiver database. Revision TKA and causes for revision, including mechanical loosening, failure/break, periprosthetic fracture, osteolysis, infection, pain, arthrofibrosis, instability, and trauma) were identified with CPT and ICD-9 Codes. Statistical analysis of this study was primarily descriptive. Results. Our query returned a total of 244,153 TKAs, of which 11,767 (4.8%) were revised. Most TKAs were performed with a glucose range of 70–99 mg/ml (26.3%), followed by 100–109 mg/ml (18.6%). Patients with TKAs performed with a glucose range of 20–29 mg/ml had the highest rate of revision (15.2%) (p<0.001) following the index procedure. Infection was the most common cause of revision among all studied glucose ranges (p<0.001). Conclusion. Infection remains one of the most common causes of