Advertisement for orthosearch.org.uk
Results 1 - 20 of 20
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 60 - 60
24 Nov 2023
Simon S Frank BJ Hartmann SG Mitterer JA Sujeesh S Huber S Hofstaetter JG
Full Access

Aims. The aim of this study was to assess the incidence the microbiological spectrum and clinical outcome of hip and knee revision arthroplasties with unexpected-positive-intraoperative-cultures (UPIC) at a single center with minimum follow up of 2 years. Methods. We retrospectively analyzed our prospectively maintained institutional arthroplasty registry. Between 2011 and 2020 we performed presumably aseptic rTHA (n=939) and rTKA (n= 1,058). Clinical outcome, re-revision rates and causes as well as the microbiological spectrum were evaluated. Results. In total, 219/939 (23.3%) rTHA and 114/ 1,058 (10.8%) rTKA had a UPIC (p<0.001). Single positive intraoperative cultures were found in 173/219 (78.9%) in rTHA and 99/114 (86.8%) in rTKA, whereas 46/219 (21.0%) rTHA and 15/114 (13.2%) rTKA had positive results in ≥2 intraoperative cultures. A total of 390 microorganisms were found among the 333 cases. Staphylococcus epidermidis 30.9%, CoNS (21.9%), Cutibacterium acnes 21.1%, and Bacillus spp. 7.3% were the most common microorganisms. Overall, detected microorganisms showed high sensitivity to daptomycin (96.6%), vancomycin (97.3%) and linezolid (98.0%). After a minimum follow up of 2 years (rTHA 1,470 (735; 3,738) days; rTKA 1,474 (749; 4,055) days). During the 2-year follow-up, 8 patients died and 5 were lost to follow-up. There were 54/219 (24.7%) re-revision in rTHa and 20/114 (17.5%) in rTKA. Overall, there were 23 (10.5%) septic re-rTHA and 9 (7.9%) septic re-rTKA as well as 31 (14.2%) aseptic re-rTHA and 11 (9.6%) aseptic re-rTKA. Patients with previous septic revisions bevor UPIC procedure showed a significant higher risk for septic re-revision (p<0.05). Moreover, there were less septic re-revisions after single culture positive UPIC (rTHA: 16/173 (9.2%); rTKA 6/99 (6.1%)) compared to ≥2 positive intraoperative cultures UPIC (rTHA: 7/46 (15.2%); rTKA 3/15 (20.0%)). The most common reason for re-revision in the rTHA-group was aseptic loosening of the cup (34.2%) or of the stem (23.3%), dislocation (18.3%) and periprosthetic-fractures (7.8%). In the rTKA-group it was aseptic loosening (40.4%), instability (24.6%) and secondary patella resurfacing (7.9%). There was a higher septic re-revision rate in consecutive revisions than in planned revisions 17.3% vs. 8.5% in the rTHA-group and 14.3% vs. 7.5% in the rTKA-group, p<0.001. Conclusion. UPICs are common in rTJA. The rate was higher in hips which may partly explained by the easier pre op joint aspiration in the knee. UPIC may lead to an increase in subsequent re-revisions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 10 - 10
10 May 2024
Penumarthy R Jennings A
Full Access

Background. Obesity has been linked with increased rates of knee osteoarthritis. Limited information is available on the survival and functional outcome results of rTKR in the obese patients. This registry-based study aimed to identify whether BMI is an independent risk factor for poorer functional outcomes and /or implant survival in rTKA. Methods. New Zealand Joint Registry (NZJR) data of patients who underwent rTKA from 1st January 2010 to January 2023 was performed. Demographics, American Society of Anesthesiologists (ASA), BMI, Operative time, indications for revision and components revised of the patients undergoing rTKA was collected. Oxford knee score (OKS) at 6 months and rates of second revision (re- revision) were stratified based on standardised BMI categories. Results. Of the 2687 revisions, functional outcome scores were available for 1261 patients. Oxford knee scores following rTKA are significantly inferior in higher BMI patients (36.5 vs 31.5 p<0.001). This held true when adjusted for age (35.7 vs 30.9 p<0.001). Tibial component loosening was a more common indication for revision in patients with BMI >40 (31.1% vs 21% for BMI <25), whereas periprosthetic femoral fracture was significantly more commonly seen in patients with BMI <25. Re-revision rates displayed no significant differences between any pairs of BMI groups (2.18/100 component years) and adjusting for age and sex did not alter this (p= 0.462). Indications for re-revision were also not different between BMI categories. Over 50% of the rTKA patients were obese. Significantly more obese patients were ASA grade 3,4 and more were <75 years. Operative time was longer in the obese patients (p<0.001). Conclusions. Although overall re-revision rates are similar between all BMI categories, the functional outcomes favour those with lower BMI. Patients with higher BMI are younger, more comorbid and carry potentially higher perioperative risks. The registry data provides valuable information when providing counsel to patients undergoing rTKA and lends further support to optimising patients prior to pTKA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 38 - 38
10 Feb 2023
Batinica B Bolam S Zhu M D'Arcy M Peterson R Young S Monk A Munro J
Full Access

Little information exists regarding optimal tibial stem usage in revision total knee arthroplasty (rTKA) utilising a tibial trabecular metal (TM) cone. The purpose of this study was to compare 1) functional outcomes, 2) radiographic outcomes, and 3) implant survivorship in rTKA utilising TM cones combined with either short stems (SS) or long stems (LS) at minimum two-years clinical follow-up. In this retrospective, multi-centre study, patients undergoing TM cone utilising rTKA between 2008 and 2019 were included. Patients were divided into: SS group (no diaphyseal engagement), and LS group (diaphyseal engagement). All relevant clinical charts and post-operative radiographs were examined. Oxford Knee Score (OKS) and EuroQol-5D (EQ-5D-5L) data were collected at most recent follow-up. In total, 44 patients were included: 18 in the SS group and 26 in the LS group. The mean time of follow-up was 4.0 years. Failure free survival was 94.5% for the SS group and 92.3% for the LS group. All failures were for prosthetic joint infections managed with debridement, antibiotics, and implant retention. At most recent follow-up, 3 patients demonstrated radiographic signs of lucency (1 SS 2 LS, p = 1) and the mean OKS were 37 ± 4 and 36 ± 6 (p = 0.73) in the SS and LS groups, respectively. Tibial SS combined with TM cones performed as well as LS in rTKA at minimum two-years follow-up. A tibial SS in combination with a TM cone is a reliable technique to achieve stable and durable fixation in rTKA


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 44 - 44
1 Feb 2021
Edwards T Patel A Szyszka B Coombs A Kucheria R Cobb J Logishetty K
Full Access

Background. Revision total knee arthroplasty (rTKA) is a high stakes procedure with complex equipment and multiple steps. For rTKA using the ATTUNE system revising femoral and tibial components with sleeves and stems, there are over 240 pieces of equipment that require correct assembly at the appropriate time. Due to changing teams, work rotas, and the infrequency of rTKR, scrub nurses may encounter these operations infrequently and often rely heavily on company representatives to guide them. In turn, this delays and interrupts surgical efficiency and can result in error. This study investigates the impact of a fully immersive virtual reality (VR) curriculum on training scrub nurses in technical skills and knowledge of performing a complex rTKA, to improve efficiency and reduce error. Method. Ten orthopaedic scrub nurses were recruited and trained in four VR sessions over a 4-week period. Each VR session involved a guided mode, where participants were taught the steps of rTKA surgery by the simulator in a simulated operating theatre. The latter 3 sessions involved a guided mode followed by an unguided VR assessment. Outcome measures in the unguided assessment were related to procedural sequence, duration of surgery and efficiency of movement. Transfer of skills was assessed during a pre-training and post-training assessment, where participants completed multi-step instrument selection and assembly using the real equipment. A pre and post-training questionnaire assessed the participants knowledge, confidence and anxiety. Results. All participants reported orthopaedics as their primary speciality with mean of 6-years experience. 80% reported they are ‘sometimes’ required to scrub for operations in which they do not feel comfortable with the equipment. All participants improved across the 3 unguided sessions reducing their operative time by 47%, assistive prompts by 75%, dominant hand motion by 28% and head motion by 36%. This transferred into the real-world: Participants completed 11.3% of tasks correctly in pre-training compared to 83.5% correct in the timely selection and assembly of rTKA equipment, post-training. All participants reported increased confidence and reduced anxiety after the training. Conclusion. Unfamiliarity with orthopaedic procedures or equipment is common for scrub nurses and can impact surgical performance. VR training improves their understanding, technical skills and efficiency in complex rTKA. These VR-learnt skills translate into the physical environment. This has important implications on how scrub nurses can be trained remotely, asynchronously and safely to perform complex orthopaedic surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 61 - 61
1 Aug 2020
Jean P Belzile E Pelet S Caron J
Full Access

Over the last decade, the number of total knee arthroplasty (TKA) has risen over 125%. Numerous studies have established a relationship between obesity and complications in primary TKA. Interestingly, few studies have investigated medical and orthopaedic complications in obese patients undergoing revision TKA (RTKA). With the increasing number of RTKA and with the prevalence of obesity still on the rise, the study of obesity on complications following RTKA is indicated. We retrospectively reviewed 180 RTKA performed by a single surgeon done between August 2008 and June 2017. All patients who underwent RTKA were included, but revisions done with simultaneous extensor mechanism reconstruction and/or distal femur replacement were excluded since these procedures are technically more demanding. 154 revisions met our inclusion/exclusion criteriaes and were included in the final analysis. 81 patients were included in the non-obese group (BMI . The total number of orthopaedic complications in the obese group (46.6%) was significantly higher than in the non-obese group (27.2%) (OR=1.71) (p = 0.01). The number of infection was higher in the obese group (11%) than in the non-obese (6.2%) but this was not statistically significant (OR=1.77) (p = 0.28). Reoperation rate was also higher in the obese group (23.3%) than in the non-obese group (16%) but this did not reach statistical significance (OR=1.46) (p = 0.26) (Table 3). Medical complications were higher in the obese group (31.5% vs 19.8%) (OR=1.59) (p=0.09). According to the Dindo-Clavien classification, the obese group demonstrated a significantly higher rate of grade 3 or higher complications (p = 0.01). Obesity significantly increases the occurrence of orthopaedic complications following RTKA. Obesity also seems to increase the number of medical complications following RTKA. The obese patient should be informed prior to revision TKA that there is an increased risk of complications when compared with the non-obese patient. Further research with higher power would seem advisable to confirm this trend. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 100 - 100
10 Feb 2023
Mactier L Baker M Twiggs J Miles B Negus J
Full Access

A primary goal of revision Total Knee Arthroplasty (rTKA) is restoration of the Joint Line (JL) and Posterior Condylar Offsets (PCO). The presence of a native contralateral joint allows JL and PCO to be inferred in a way that could account for patient-specific anatomical variations more accurately than current techniques. This study assesses bilateral distal femoral symmetry in the context of defining targets for restoration of JL and PCO in rTKA. 566 pre-operative CTs for bilateral TKAs were segmented and landmarked by two engineers. Landmarks were taken on both femurs at the medial and lateral epicondyles, distal and posterior condyles and hip and femoral centres. These landmarks were used to calculate the distal and posterior offsets on the medial and lateral sides (MDO, MPO, LDO, LPO respectively), the lateral distal femoral angle (LDFA), TEA to PCA angle (TEAtoPCA) and anatomic to mechanical axis angle (AAtoMA). Mean bilateral differences in these measures were calculated and cases were categorised according to the amount of asymmetry. The database analysed included 54.9% (311) females with a mean population age of 68.8 (±7.8) years. The mean bilateral difference for each measure was: LDFA 1.4° (±1.0), TEAtoPCA 1.3° (±0.9), AAtoMA 0.5° (±0.5), MDO 1.4mm (±1.1), MPO 1.0mm (±0.8). The categorisation of asymmetry for each measure was: LDFA had 39.9% of cases with <1° bilateral difference and 92.4% with <3° bilateral difference, TEAtoPCA had 45.8% <1° and 96.6% <3°, AAtoMA had 85.7% <1° and 99.8% <3°, MDO had 46.2% <1mm and 90.3% <3mm, MPO had 57.0% <1mm and 97.9% <3mm. This study presents evidence supporting bilateral distal femoral symmetry. Using the contralateral anatomy to obtain estimates for JL and PCO in rTKA may result in improvements in intraoperative accuracy compared to current techniques and a more patient specific solution to operative planning


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 1 - 1
1 Oct 2022
Simon S Frank BJH Aichmair A Dominkus M Mitterer JA Hartmann S Kasparek M Hofstätter J
Full Access

Purpose. Unexpected-positive-intraoperative-cultures (UPIC) in presumed aseptic revision-total-knee-arthroplasties (rTKA) are common, and the clinical significance is not entirely clear. In contrast, in some presumably septic rTKA, an identification of an underlying pathogen was not possible, so called unexpected-negative-intraoperative-cultures (UNIC). The purpose of this study was to evaluate alpha defensin (AD) levels in these patient populations. Methods. In this retrospective analysis of our prospectively maintained biobank, we evaluated synovial AD levels from 143 rTKAs. The 2018-Musculoskeletal Infection Society score (MSIS) was used to define our study groups. Overall, 20 rTKA with UPIC with a minimum of one positive intraoperative culture with MSIS 2-≥6 and 14 UNIC samples with MSIS≥6 were compared to 34 septic culture-positive samples (MSIS ≥6) and 75 aseptic culture-negative (MSIS 0–1) rTKAs. Moreover, we compared the performance of both AD-lateral-flow-assay (ADLF) and an enzyme-linked-immunosorbent-assay (ELISA) to test the presence of AD in native and centrifuged synovial fluid. Concentration of AD determined by ELISA and ADLF methods, as well as microbiological, and histopathological results, serum and synovial parameters along with demographic factors were considered. Results. AD was detected in 31/34 (91.2%) samples from the infected-group and in 14/14 (100%) samples in the UNIC group. All UPIC samples showed a negative AD result. Positive AD samples were highly (p<0.001) associated with culture positive and infection related histopathological results. Moreover, we found significantly (p=0.001) more high-virulent microorganisms 19/34 (55.9%) in the infected-group compared to the UPIC-group (0/20). Samples from the infected group with high virulent microorganisms 17/19 (89.5%) showed a positive AD. The presence of methicillin resistant Staphylococcus epidermis (MRSE) led to increased AD (p=0.003) levels when compared to those determined in samples positive for methicillin susceptible S. epidermdis (MSSE). ELISA and ADLF tests were positive with centrifuged (8/8) and native (8/8) synovial fluid. Conclusion. AD showed a solid diagnostic performance in infected and non-infected revisions, and it provided an additional value in the diagnostic of UPIC and UNIC associated to rTKAs. AD levels produced by patients with PJIs caused by high-virulent microorganisms and MRSE are significantly higher compared to those in patients with PJIs caused by either low-virulent or antibiotic susceptible microorganisms. Centrifugation of synovial fluid had no influence in the outcome of ADLF quantification. Keywords: Alpha-defensin, UPIC, UNIC, revision-knee-arthroplasty


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 69 - 69
1 Apr 2019
Blevins K Danoff J Goel R Foltz C Chen AF Hozack W
Full Access

Introduction. The purpose of this study is to compare total and rate of caloric energy expenditure between conventional and robotic-arm assisted total knee arthroplasty (TKA) between a high volume “veteran” surgeon (HV) and a lower volume, less experienced surgeon (LV). Methods. Two specialized arthroplasty surgeons wore a biometric-enabled shirt and energy expenditure outcomes were measured (total caloric expenditure, kilocalories per minute, heart rate variability, and surgical duration) during 35 conventional (CTKA) and 29 robotic primary total knee arthroplasty (RTKA) procedures. Results. Overall, the rate of caloric expenditure was similar between RTKA (5.60 ±2.50 kcal/min) and CTKA (4.79cal/min ±1.79, p=0.25). With 6.15 minute longer operative times, the total energy expenditure (TEE) for RTKA (239.31±96.79 kcal) was higher thanCTKA(181.54 ±80.90 kcal, p<0.001). The HV surgeon's TEE (p<0.001) and rate of energy expenditure (REE) (p<0.001) were significantly higher in RTKA (261.53cal; 6.499cal/min) versus CTKA (71.00cal; 3.759cal/min). However, the LV surgeon's TEE and REE for RTKA (207.83cal; 4.32cal/min) and CTKA (195.81cal; 4.92cal/min) were not significantly different (p>0.05). Both surgeons (HV; LV) had significantly longer surgical durations (p<0.001) in RTKA (40.41 ±4.94min; 48.91 ±8.45min) compared to CTKA surgeries (18.75±4.27min; 40.4 ±8.34min), respectively. Conclusion. While REE did not varybetween CTKA and RTKA for the LV surgeon, it did vary significantly for the HV surgeon. Additionally, RTKA took longer and increased TEE, but one less operating room assistant was needed. Surgeons with less experience in TKA may be less likely to notice a difference in energy expenditure when utilizing robotic-arm assisted technology. It is possible that more experience with using the robotic arm could create efficiencies over time that may also reduce TEE


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 106 - 106
1 Jul 2020
Dion C Lanting B Howard J Teeter M Willing R
Full Access

During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium alloy (Ti6Al4V) revision augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of rTKA with this augment in comparison to conventional cemented rTKA. Eleven pairs of thawed fresh-frozen cadaveric tibias (22 tibias) were potted in custom fixtures. Primary total knee arthroplasty (pTKA) surgery was performed on all tibias. Fixation stability testing was conducted using a three-stage eccentric loading protocol. Static eccentric (70% medial/ 30% lateral) loading of 2100 N was applied to the implants before and after subjecting them to 5×103 loading cycles of 700 N at 2 Hz using a joint motion simulator. Bone-implant micromotion was measured using a high-resolution optical system. The pTKA were removed. The proximal tibial bone defect was measured. One tibia from each pair was randomly allocated to the experimental group, and rTKA was performed with a titanium augment printed using selective laser melting. The contralateral side was assigned to the control group (revision with fully cemented stems). The three-stage eccentric loading protocol was used to test the revision TKAs. Independent t-tests were used to compare the micromotion between the two groups. After revision TKA, the mean micromotion was 23.1μm ± 26.2μm in the control group and 12.9μm ± 22.2μm in the experimental group. There was significantly less micromotion in the experimental group (p= 0.04). Prior to revision surgery, the control and experimental group had no significant difference in primary TKA micromotion (p= 0.19) and tibial bone loss (p= 0.37). This study suggests that early fixation stability of revision TKA with the novel 3D printed titanium augment is significantly better then the conventional fully cemented rTKA. The early press-fit fixation of the augment is likely sufficient for promoting bony ingrowth of the augment in vivo. Further studies are needed to investigate the long-term in-vivo fixation of the novel 3D printed augment


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 2 - 2
1 Mar 2021
Higuera-Rueda C Emara A Nieves-Malloure Y Klika AK Cooper H Cross M Guild G Nam D Nett M Scuderi G Cushner F Silverman R
Full Access

Aim. This was a multicenter, randomized, clinical trial to compare the 90-day 1) incidence of surgical site complications (SSC); 2) health care utilization (the number of dressing changes, readmission, and reoperation); and 3) the patient-reported outcomes (PRO) in high-risk patients undergoing revision total knee arthroplasty (rTKA) with postoperative closed incision negative pressure wound therapy (ciNPT) versus a standard of care (SOC) silver-impregnated occlusive dressing. Method. A total of 294 rTKA patients (15 centers) at high-risk for wound complications were prospectively randomized to receive either SOC or ciNPT (n = 147 each). The ciNPT system was adjusted at 125 mmHg of suction. Investigated outcomes were assessed weekly up to 90 days after surgery. A preset interim analysis was conducted at 50% of the intended sample size, with planned discontinuation for clear efficacy/harm if a significance of p < 0.005 was attained. Results. A total of 242 patients completed the required follow-up (ciNPT: n = 124 (84.4%); SOC: n = 118 (80.3%)). Demographics, baseline comorbidities, causes of revision (prosthetic joint infection, aseptic loosening, implant-related, and periprosthetic fractures), and duration of treatment were similar in both cohorts (p > 0.05). Intention to treat analysis demonstrated lower rates of SSC with ciNPT (3.4%) compared to SOC (14.3%) (p = 0.0013) (Table 1 – not included in the proceeding). Similar outcomes were obtained with the modified intention to treat analysis (p = 0.0013). The ciNPT cohort exhibited lower readmission rates (p = 0.0208), and number of dressing changes (p = 0.0003). Conversely, differences in the 90-day incidence of SSI and measured patient-reported outcomes did not reach statistical significance (p > 0.05). Conclusions. ciNPT mitigates the risk of SSC and readmission among high-risk rTKA patients. The lower frequency of dressing changes within the ciNPT cohort may provide added value for healthcare utilization without compromising pain and function. For the table, please contact authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 55 - 55
1 Feb 2017
Brozyniak C Hitt K Della Valle C Campbell D
Full Access

INTRODUCTION. As the demographic of the patient population requiring revision total knee arthroplasty (rTKA) continues to expand, varying preoperative conditions and activity levels need to be taken into consideration when analyzing postoperative outcomes. Factoring in preoperative activity levels can help manage the expectations of patients. The purpose of this study was to analyze the outcomes of low and high activity patients receiving a contemporary rTKA. METHODS. One hundred and eighty rTKA patients enrolled in a prospective, multicenter study were evaluated through 2 years postoperative. Patients were divided into groups based on preoperative activity level using the Lower Extremity Activity Scale (LEAS). Patients scoring between 1–7 were classified as ‘Low Activity’ (LA, N=104) and patients scoring 8–18 were classified as ‘High Activity’ (HA, N=76). Clinical and patient-reported outcomes were evaluated, with an additional quality of life analysis completed utilizing SF-6D scores obtained by transforming SF-36 scores through a method described by Brazier et al. and analyzed for effect size. RESULTS. No differences were seen in age or BMI between the groups, with more females in the LA group (64%) and majority males in the HA group (58%). Both groups displayed statistically significant improvements through 2 years; however the degree of improvement varied based on outcome measure. Postoperative improvement in both groups were similar in the KSS, but patients in the LA group showed larger increases in the KSS Functional assessment at 6 weeks and 2 years (Figure 1). The effect of rTKA was analyzed through an SF-6D analysis (Figure 2). There was a statistically significant large effect seen in the LA group at 1 year (0.96), which was in conjunction with a higher SF-6D outcome (Figure 2). CONCLUSION. The current study population displayed significant improvement in functional patient outcomes following rTKA regardless of preoperative activity level and function. Patients with lower preoperative activity levels demonstrated not only greater cumulative functional improvements, but also had significant improvements in quality of life following rTKA. This suggests that the preoperative lower activity level may be in part related to the poorly functioning knee and that revision surgery has the potential to improve overall activity levels and function


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 42 - 42
1 Dec 2018
Glehr M Klim S Amerstorfer F Bernhardt G Sadoghi P Gruber G Leithner A Radl R
Full Access

Aim. Bone loss is a severe problem in septic revision total knee arthroplasty (RTKA). The use of porous coated metaphyseal sleeves is a promising treatment option for extended bone defects. The currently published mid-term results remain limited and no study has been focused exclusively on septic cases. Our aim was to determine the implant survivorship (with special focus on osseointegration) and the clinical and radiological mid-term outcome of metaphyseal sleeve fixation in septic RTKA surgery (minimum follow-up of 2 years). Method. Between January 2005 and September 2015, 57 patients underwent septic RTKA surgery using metaphyseal sleeves. In 56 patients (98,2 %) who underwent a total of 69 two stage revision procedures, clinical and radiological follow-up examinations were conducted. One patient (1,8 %) was lost to follow-up. The examinations included the American Knee Society Score (KSS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the SF-36 Health survey as well as radiographic measurement to determine if successful osseointegration had been achieved. Results. Thirteen knees (18.8%) had to be re-revised at the time of follow-up (mean 5.3 years, min. 2 – max. 11.2), all due to reinfection (Figure 1). We did not encounter any cases of aseptic loosening. The mean range of motion (92° ± 21°), SSS (7 ± 2), KSS (76 ± 19), WOMAC (70 ± 20), SF-36 MCS (55 ± 14) and SF-36 PCS (35 ± 9) have shown satisfying results. Conclusions. Metaphyseal sleeves have shown very promising mid-term results regarding clinical scores, osseointegration, and aseptic loosening. Our results are the first analysing the performance of metaphyseal sleeves in exclusively septic cases and show that they are a reliable fixation option in septic RTKA patients with severe bone loss


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 68 - 68
24 Nov 2023
Luger M Windhager R Sigmund I
Full Access

Aim. Serum parameters continue to be a focus of research in diagnosing periprosthetic joint infections (PJI). Several workgroups have recently proposed serum Albumin-Globulin-Ratio (AGR) as a potential new biomarker. Due to controversies in the literature, its usability in clinical practice remains uncertain. The aim of this study was to assess the value of serum AGR in diagnosing PJI preoperatively, especially in comparison with the well-established marker C-reactive Protein (CRP). Method. From January 2015 to June 2022, patients with indicated revision hip (rTHA) and knee (rTKA) arthroplasty were included in this retrospective cohort study of prospectively collected data. A standardized diagnostic workup was performed using the 2021 European Bone and Joint Infection Society (EBJIS) definition of PJI, excluding CRP. Diagnostic accuracies of serum AGR and CRP were calculated by receiver operating characteristic curve (ROC) analysis. A z-test was used to compare the area under the curves (AUC). Results. A total of 275 patients with rTHA and rTKA were included, 144 joints (52.4%) were identified as septic. Decreased AGR and elevated CRP were strongly associated with PJI, optimal diagnostic thresholds were calculated with 1.253 and 9.4 mg/L, respectively. Sensitivities were 62.5% (95%-confidence interval: 54.3–70.0) and 73.6% (65.8–80.1), and specificities 84.7% (77.5–89.9) and 87.8% (80.9–92.4), respectively. CRP showed a significantly higher AUC than AGR (0.807 (0.761–0.853) and 0.736 (0.686–0.786); p<0.0001). Subgroup analysis of acute versus chronic infections yielded significantly higher diagnostic accuracies in acute PJI for both parameters (p<0.0001). Similar results were observed when focusing on the causative microorganism; a better diagnostic performance was observed in high-virulence PJI compared to low-virulence PJI (p≤0.005). Furthermore, higher AUCs were calculated in knee PJI compared with hip PJI, with a significant difference for AGR (p=0.043). Conclusions. Due to its limited diagnostic accuracy, serum AGR cannot be recommended as an additional marker for diagnosing PJI. Serum parameters are generally unspecific and can be influenced by comorbidities and other foci of infection. Additionally, parameters may remain within normal levels in low-grade PJI. Evaluating AGR, further possible pitfalls must be considered, for example an increased latency until bottom values are reached and the impact of malnutrition


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 45 - 45
1 Dec 2017
Glehr M Klim S Sadoghi P Bernhardt G Leithner A Radl R Amerstorfer F
Full Access

Aim. One of the most challenging problems in total knee arthroplasty (TKA) is periprosthetic infection. A major problem that arises in septic revision TKA (RTKA) are extended bone defects. In case of extended bone defects revision prostheses with metaphyseal sleeves are used. Only a few studies have been published on the use of metaphyseal sleeves in RTKA - none were septic exclusive. The aim of our study was to determine the implant survival, achieved osseointegration as well as the radiological mid-term outcomes of metaphyseal sleeve fixation in septic two-stage knee revision surgery. Method. Clinical and radiological follow-up examinations were performed in 49 patients (25 male and 24 female). All patients were treated with a two-stage procedure, using a temporary non-articulating bone cement spacer. The spacer was explanted after a median of 12 weeks (SD 5, min. 1 – max. 31) and reimplantation was performed, using metaphyseal sleeves in combination with stem fixation. Bone defects were classified on preoperative radiographs using the Anderson Orthopaedic Research Institute (AORI) classification. During follow-up postoperative range of motion (ROM) was measured and radiographs were performed to analyse: (i) osseointegration (radiolucent lines and spot welds), (ii) leg alignment, (iii) patella tilt and shift. Results. All types of bone defects were found on the tibial (4× type 1, 7× type 2a, 26× type 2b, 9× type 3) as well as on the femoral side (1× type 1, 4× type 2a, 20× type 2b, 6× type 3). Mean follow-up time was 4.7 years (minimum 1 year). In total 12 knees (24.5%) had to be re-revised, all due to re-infection. We did not encounter any case of aseptic loosening. In 3 patients (6.8%) we detected an insufficient osseointegration, but no patient had to be re-revised due to only minimal or to the absence of symptoms and no clinical signs of loosening. The ROM (mean 93°, SD 20.6, min. 25° max. 125°) has shown very satisfying results at the time of follow-up. Malalignment was detected in 4 patients (10.3%), a patella tilt in 7 (19.4%) and a patella shift in 14 (48.3%). Conclusions. Metaphyseal Sleeves have shown very promising mid-term results regarding osseointegration and aseptic implant survival in RTKA with compromised metaphyseal bone stock. Our results indicate that they are a reliable fixation option in septic RTKA patients


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 101 - 101
1 Apr 2019
Eymir M Unver B Karatosun V
Full Access

Background. Revision total knee arthroplasties (rTKA) are performed with increasing frequency due to the increasing numbers of primary arthroplasties, but very little is known regarding the influence of muscle strength impairments on functional limitations in this population. Objectives. The aim of this study was to assess relationship between muscle strength and functional level in patient with rTKA. Design and Methods. Twenty-three patients (8 males, 15 females) were included in the study with mean age 68.4±10 years. Patients performed 3 performance tests (50-Step Walking Test, 10 Meter Walk Test, 30-Second Chair-Stand Test), and one self-report test (HSS) were preferred to assess patients. The maximum isometric muscle strength of quadriceps femoris and hamstring muscles of all the patients was measured using Hand-Held Dynamometer (HHD). Results. While moderate-to-strong significant correlations was found between quadriceps femoris muscle strength and 30- Second Chair-Stand Test (r=0.390, p=0.049), 50-Step Walking Test (r=−0.530, p=0.005), 10 Meter Walk Test (r=−0.587, p=0.002), there were not significant correlation between HSS knee score and all performance-based tests (p>0.05). Also there were not significant correlation between hamstring muscle strength and all other measurement tests (p>0.05). Conclusion. The moderate-to-strong statistical significant correlation between quadriceps femoris muscle strength and functional performance tests suggests that improved postoperative quadriceps strengthening could be important to enhance the potential benefits of rTKA


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 1 - 1
1 Mar 2021
Warren J Anis H Klika AK Bowers K Pannu T Villa J Piuzzi N Colon-Franco J Higuera-Rueda C
Full Access

Aim. Despite several synovial fluid biomarkers for diagnosis of periprosthetic joint infection (PJI) have being investigated, point-of-care (POC) tests using these biomarkers are not widely available. Synovial calprotectin has recently been reported to effectively exclude diagnosis of PJI and a novel lateral flow POC test using it has shown potential to be effective. Thus, the aims of this study were to 1) validate calprotectin POC with enzyme linked immunosorbet assay (ELISA) 2) at 2 separate thresholds for PJI diagnosis in total knee arthroplasty (TKA) patients using the 2013 Musculoskeletal Infection Society (MSIS) PJI diagnosis criteria as the gold standard. Method. Intraoperative synovial fluid samples were prospectively collected from 123 patients who underwent revision TKAs (rTKA) at two academic hospitals within the same healthcare system from October 2018 to January 2020. The study was conducted under IRB approval. Included patients followed the hospital standard for their PJI diagnostic work-up. Data collection included demographic, clinical, and laboratory data in compliance with MSIS criteria. Synovial fluid samples were analysed by calprotectin POC and ELISA tests in accordance with manufacturer's instructions. Patients were categorized as septic or aseptic using MSIS criteria by two independent reviewers blinded to calprotectin assay results. The calprotectin POC and ELISA test performance characteristics were calculated with sensitivities, specificities, positive, and negative predicted values (PPV and NPV, respectively) and areas under the curve (AUC) for 2 different PJI diagnosis scenarios: (1) a threshold of >50 mg/L and (2) a threshold of >14 mg/L. Results. According to MSIS criteria, 53 rTKAs were septic while 70 rTKA were aseptic. In the (1) >50 mg/mL threshold scenario, the calprotectin POC and ELISA performance showed 100% agreement with sensitivity, specificity, PPV, NPV, and AUC, respectively, of 98.1%, 95.7%, 94.5%, 98.5%, and 0.969. In the (2) >14 mg/mL threshold scenario, the POC slightly outperformed the ELISA with sensitivity, specificity, PPV, NPV and AUC of 98.1%, 87.1%, 85.2%, 98.4%, and 0.926, respectively (ELISA values were 98.1%, 82.9%, 81.3%, 98.3%, and 0.905, respectively). Conclusions. The calprotectin POC test performed as well as the ELISA at the >50mg/L threshold and was slightly better at the >14 mg/L threshold. The >50 mg/L threshold had a better specificity while maintaining the same sensitivity as the >14 mg/L threshold. This test could be effectively implemented as a rule out test. However, further investigations with larger cohorts are necessary to validate these results


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 58 - 58
1 Apr 2019
Dharia M Armacost J Son Y
Full Access

INTRODUCTION. Porous metal bone fillers are frequently used to manage bony defects encountered in revision total knee arthroplasty (rTKA). Compared to structural graft, porous metal bone fillers have shown significantly lower loosening and failure rates potentially due to osseointegration and increased material strength [1]. The strength of porous metal bone fillers used in lower extremities is frequently assessed using compression/shear/torsion test methods, adapted from spine standards. However, these basic methods may lack clinical relevance, and do not provide any insight on the relationship between patient activity and anticipated prosthesis performance. The goal of this study was to evaluate the response of bone fillers under different activities of daily living, in order to define physiologically relevant worst case biomechanics for component evaluation. METHODS. A bone filler tibial augment is shown in Figure 1. A test construct for tibial augments (half-block each for medial and lateral sides) is shown in Figure 2, along with compatible rTKA components. An additional void in the bone was filled using bone cement. Loading was applied through the tibiofemoral contact patches created on polyethylene tibial insert. Loading was used for two activities of daily living; walking and deep knee bend [2–3]. During walking, the tibiofemoral contact patch on the anterior tibial post gets loaded due to femoral hyperextension with 1.2xbody weight (BW), whereas the medial and lateral condyles get loaded with 3xBW compressive load. For deep knee bend, only the condyles get loaded with 4.34xBW. Compared to walking, 45% higher compressive load magnitude in deep knee bend located further posterior was anticipated to create a larger bending moment and induce higher stress on the half augments. A finite element analysis (FEA) was performed by modeling this test construct with a medium size tibial augment. All components were modeled using linear elastic material properties. All interfaces, including the augment-bone interface (representing full bony ingrowth construct) were modeled using bonded contact. The inferior surface of the bone analogue was constrained. Linear static analyses were performed and peak von mises stress predicted in the tibial augments was compared between activities. RESULTS. Deep knee bend resulted in 31% higher stresses in the tibial augments than for walking. High von mises stresses were mostly predicted at the superior/posterior aspect of the internal side of the augment and in the corners of the cutouts. Figure 3 presents the von mises stresses in the tibial augments for both loading scenarios. DISCUSSION. This study revealed that the 45% increased posterior compressive load associated with deep knee bend is a more significant factor than the moment applied to the post during walking gait for a hyperextended knee, when considering the stress in bone filler augments in revision TKA. The stress in the augments can depend on multiple factors and the proposed FEA method can be used to compare stresses in different porous material bone fillers to determine worst case for assessing its strength


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 67 - 67
1 Dec 2017
Giordano G
Full Access

INTRODUCTION. The functional and anatomical results of TKA revisions are less good than a primary TKA. The TKA revision frequency increases and we must improve our surgeries and prepare the next standard of these surgeries. The aim of this study was to evaluate the CAOS / one stage strategie to treat the knee PJIs. MATERIALS. In this prospective study, between September 2011 and December 2014, 41 patients treated for chronic knee PJI in a one stage revision. For all of them, an imageless CAOS system (ExactechGPS, Blue- Ortho, Gieres) was used. A personalised profile of revision was created. All surgeries were performed with the same protocole and by using the same Optetrak CC knee components (Exactech, Gainesville, FL). All operations were performed by a single senior surgeon. Indications for the revision TKA were (1) revision of a primary TKA or unicondylar knee arthroplasty (n=27) or (2) revision of revisionTKA (n=15). The measurement of the HKA angle, the Oxford score and the ROM were evaluated pre and post- operatively. RESULTS. 27 males and 14 females with an average age of 71 years old (55–87) were treated for a PIJ (1 unicompartimental prosthesis, 26 TKA and 15 RTKA). The mean follow-up was 41 months (30 months − 6 years). The average time of surgery was 135 mn (120–195) for an average hospitalisation duration of 10 days (7–16). No postoperative outliers were reported (mean preop.: −1,6°+/_−5,1° − Post- op. −0,3°+/_ −1,4°). The average ROM were 115° (90–130°) (Fig. 1). The rate of success for the infection was 92,7%. We report no specific CAS complications and all the navigations were finalised. In this series of complex cases, the rate of infection healing is 92,7%. DISCUSSION. Using CAOS is a safe option with no specific complication. Combined with one stage procedures, it should be an optimal medico-economical strategy for Knee revisions. This first series initiated the « GPS RTKA » project to create a dedicated software evaluated since January 2016 with immediate very good functional results and no complications. For figures and tables, please contact authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 125 - 125
1 Mar 2017
Roche M Law T Triplet J Hubbard Z Kurowicki J Rosas S
Full Access

Introduction. It is well established that diabetic patients undergoing total knee arthroplasty (TKA) are more susceptible to infection, problematic wound healing, and have overall higher complication rates. However there is a paucity in current literature investigating the effects of hypoglycemia on TKA. The purpose of this study was to determine the effect of hypoglycemia on TKA revision (rTKA) incidence analyzing a national private payer database for procedures performed between 2007 and 2015 Q1. Methods. A retrospective review of a national private payer database within the PearlDiver Supercomputer application (Warsaw, IN, USA) for patients undergoing TKA with blood glucose levels ranging from 20 to 219 mg/ml, in increments of 10 mg/ml, was conducted. Patients who underwent TKA were identified by Current Procedural Terminology (CPT)-27447 and International Classification of Disease (ICD) code 81.54. Glucose ranges were identified by filtering for lab identifier values unique to the PearlDiver database. Revision TKA and causes for revision, including mechanical loosening, failure/break, periprosthetic fracture, osteolysis, infection, pain, arthrofibrosis, instability, and trauma) were identified with CPT and ICD-9 Codes. Statistical analysis of this study was primarily descriptive. Results. Our query returned a total of 244,153 TKAs, of which 11,767 (4.8%) were revised. Most TKAs were performed with a glucose range of 70–99 mg/ml (26.3%), followed by 100–109 mg/ml (18.6%). Patients with TKAs performed with a glucose range of 20–29 mg/ml had the highest rate of revision (15.2%) (p<0.001) following the index procedure. Infection was the most common cause of revision among all studied glucose ranges (p<0.001). Conclusion. Infection remains one of the most common causes of rTKA irrespective of glucose level. Our results suggest that hypoglycemia may increase revision rates among TKA patients. Tight glycemic control prior to and during surgery may be warranted


Bone & Joint Open
Vol. 2, Issue 9 | Pages 721 - 727
1 Sep 2021
Zargaran A Zargaran D Trompeter AJ

Aims

Orthopaedic infection is a potentially serious complication of elective and emergency trauma and orthopaedic procedures, with a high associated burden of morbidity and cost. Optimization of vitamin D levels has been postulated to be beneficial in the prevention of orthopaedic infection. This study explores the role of vitamin D in orthopaedic infection through a systematic review of available evidence.

Methods

A comprehensive search was conducted on databases including Medline and Embase, as well as grey literature such as Google Scholar and The World Health Organization Database. Pooled analysis with weighted means was undertaken.