Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:

Instability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability. This is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; SERF, DÉCINES-CHARPIEU, FRANCE) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation. With a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients. The use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years. That's why we also recommend DM cup for all high risk of dislocation situations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 60 - 60
24 Nov 2023
Simon S Frank BJ Hartmann SG Mitterer JA Sujeesh S Huber S Hofstaetter JG
Full Access

Aims. The aim of this study was to assess the incidence the microbiological spectrum and clinical outcome of hip and knee revision arthroplasties with unexpected-positive-intraoperative-cultures (UPIC) at a single center with minimum follow up of 2 years. Methods. We retrospectively analyzed our prospectively maintained institutional arthroplasty registry. Between 2011 and 2020 we performed presumably aseptic rTHA (n=939) and rTKA (n= 1,058). Clinical outcome, re-revision rates and causes as well as the microbiological spectrum were evaluated. Results. In total, 219/939 (23.3%) rTHA and 114/ 1,058 (10.8%) rTKA had a UPIC (p<0.001). Single positive intraoperative cultures were found in 173/219 (78.9%) in rTHA and 99/114 (86.8%) in rTKA, whereas 46/219 (21.0%) rTHA and 15/114 (13.2%) rTKA had positive results in ≥2 intraoperative cultures. A total of 390 microorganisms were found among the 333 cases. Staphylococcus epidermidis 30.9%, CoNS (21.9%), Cutibacterium acnes 21.1%, and Bacillus spp. 7.3% were the most common microorganisms. Overall, detected microorganisms showed high sensitivity to daptomycin (96.6%), vancomycin (97.3%) and linezolid (98.0%). After a minimum follow up of 2 years (rTHA 1,470 (735; 3,738) days; rTKA 1,474 (749; 4,055) days). During the 2-year follow-up, 8 patients died and 5 were lost to follow-up. There were 54/219 (24.7%) re-revision in rTHa and 20/114 (17.5%) in rTKA. Overall, there were 23 (10.5%) septic re-rTHA and 9 (7.9%) septic re-rTKA as well as 31 (14.2%) aseptic re-rTHA and 11 (9.6%) aseptic re-rTKA. Patients with previous septic revisions bevor UPIC procedure showed a significant higher risk for septic re-revision (p<0.05). Moreover, there were less septic re-revisions after single culture positive UPIC (rTHA: 16/173 (9.2%); rTKA 6/99 (6.1%)) compared to ≥2 positive intraoperative cultures UPIC (rTHA: 7/46 (15.2%); rTKA 3/15 (20.0%)). The most common reason for re-revision in the rTHA-group was aseptic loosening of the cup (34.2%) or of the stem (23.3%), dislocation (18.3%) and periprosthetic-fractures (7.8%). In the rTKA-group it was aseptic loosening (40.4%), instability (24.6%) and secondary patella resurfacing (7.9%). There was a higher septic re-revision rate in consecutive revisions than in planned revisions 17.3% vs. 8.5% in the rTHA-group and 14.3% vs. 7.5% in the rTKA-group, p<0.001. Conclusion. UPICs are common in rTJA. The rate was higher in hips which may partly explained by the easier pre op joint aspiration in the knee. UPIC may lead to an increase in subsequent re-revisions


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 41 - 41
1 Oct 2014
Illgen RL Conditt M
Full Access

Component malposition in total hip arthroplasty (THA) contributes to wear, dislocation, and leg length discrepancy (LLD). Robotic assisted total hip arthroplasty (rTHA) utilises computer-assisted haptically guided bone preparation and implant insertion to improve accuracy. The goal of this study is to compare accuracy and clinical outcome with manual THA (mTHA) and rTHA at minimum 1 year follow-up interval. Consecutive primary THA performed by one fellowship trained surgeon included: the first 100 mTHAs in his clinical practice (Group1- year 2000), the last 100 mTHAs before rTHA use (Group2- year 2010), and the first 100 rTHA (Group3- year 2011). All THAs utilised cementless implants, cross-linked polyethylene, and a posterior approach. Comparisons included age, sex, diagnosis, implant head size, blood loss (EBL), operative time, LLD, early dislocation and infection. Acetabular abduction (AAB), anteversion (AAV), and LLD were measured using validated software (Martell Hip Analysis Suite). The Lewinnek safe zone defined accuracy (AAB- 30°-50°, AAV- 5°-25°). Statistical analysis included ANOVA, Chi squared, and Fisher tests. Power analysis demonstrated adequate sample sizes. No differences were noted regarding group demographics. Average operative times varied: Group 1, 2, and 3- (160, 129, and 143 minutes, respectively). No deep infections occurred in any group. LLD greater than 1.5 cm varied: Groups 1, 2, and 3 (9%, 1%, 1%, respectively). Dislocation rates varied: Groups 1, 2, and 3- (5%, 3%, and 0%, respectively). EBL was less with rTHA than mTHA (Groups 1, 2, 3: 533cc, 437cc, 357cc, respectively). Average implant head size increased comparing Groups 1, 2, and 3 (31mm, 34.6mm, and 35.2mm, respectively). AAB accuracy varied: Groups 1, 2, and 3 (66%, 91%, and 98%, respectively). AAB greater than 55 degrees varied: Groups 1, 2, and 3 (15%, 1%, and 0%, respectively). There was a 3% fractured acetabular liner rate in Group 1, all cases occurred with AAB > 55 degrees, and AAB greater than 55 degrees correlated with increased acetabular liner fracture rate (20% vs. 0%, P < 0.05). No cases of fractured acetabular liners occurred in Group 2 or 3. rTHA improved AAV accuracy compared with mTHA (Group 2- 48%, Group 3- 75%; p<0.0001). Improved acetabular component accuracy with rTHA correlated with lower dislocation rates compared with mTHA (p<0.001). Total hip arthroplasty performed with traditional manual techniques has demonstrated excellent clinical outcomes in the majority of patients with many THA designs if components are placed accurately. Limitations in mTHA remain that alter results if accurate component placement is not achieved. In our study, clinical experience over 10 years improved AAB accuracy with mTHA, but AAV remained problematic. rTHA improved AAB and AAV accuracy compared with mTHA and demonstrated reduced early dislocation rates, improved rate of LLD, and reduced acetabular liner fracture risk compared with mTHA (p<0.05). Average rTHA operative times were 14 minutes longer than mTHA (Group 2), but this was not associated with increased EBL or infection rates. Further study is needed to evaluate whether the short term clinical and radiographic advantages noted with rTHA compared with mTHA will be maintained at longer follow up intervals


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 68 - 68
24 Nov 2023
Luger M Windhager R Sigmund I
Full Access

Aim. Serum parameters continue to be a focus of research in diagnosing periprosthetic joint infections (PJI). Several workgroups have recently proposed serum Albumin-Globulin-Ratio (AGR) as a potential new biomarker. Due to controversies in the literature, its usability in clinical practice remains uncertain. The aim of this study was to assess the value of serum AGR in diagnosing PJI preoperatively, especially in comparison with the well-established marker C-reactive Protein (CRP). Method. From January 2015 to June 2022, patients with indicated revision hip (rTHA) and knee (rTKA) arthroplasty were included in this retrospective cohort study of prospectively collected data. A standardized diagnostic workup was performed using the 2021 European Bone and Joint Infection Society (EBJIS) definition of PJI, excluding CRP. Diagnostic accuracies of serum AGR and CRP were calculated by receiver operating characteristic curve (ROC) analysis. A z-test was used to compare the area under the curves (AUC). Results. A total of 275 patients with rTHA and rTKA were included, 144 joints (52.4%) were identified as septic. Decreased AGR and elevated CRP were strongly associated with PJI, optimal diagnostic thresholds were calculated with 1.253 and 9.4 mg/L, respectively. Sensitivities were 62.5% (95%-confidence interval: 54.3–70.0) and 73.6% (65.8–80.1), and specificities 84.7% (77.5–89.9) and 87.8% (80.9–92.4), respectively. CRP showed a significantly higher AUC than AGR (0.807 (0.761–0.853) and 0.736 (0.686–0.786); p<0.0001). Subgroup analysis of acute versus chronic infections yielded significantly higher diagnostic accuracies in acute PJI for both parameters (p<0.0001). Similar results were observed when focusing on the causative microorganism; a better diagnostic performance was observed in high-virulence PJI compared to low-virulence PJI (p≤0.005). Furthermore, higher AUCs were calculated in knee PJI compared with hip PJI, with a significant difference for AGR (p=0.043). Conclusions. Due to its limited diagnostic accuracy, serum AGR cannot be recommended as an additional marker for diagnosing PJI. Serum parameters are generally unspecific and can be influenced by comorbidities and other foci of infection. Additionally, parameters may remain within normal levels in low-grade PJI. Evaluating AGR, further possible pitfalls must be considered, for example an increased latency until bottom values are reached and the impact of malnutrition


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 49 - 49
1 Dec 2013
Domb B El Bitar Y Stone JC Jackson T Lindner D Stake C
Full Access

Background:. Total hip arthroplasty (THA) has been proven to be successful in achieving adequate pain relief and favorable outcomes in patients suffering from hip osteoarthritis (OA). However, leg length discrepancy (LLD) is still a significant cause of morbidities such as nerve damage, low back pain and abnormal gait. Despite most of the reported values of LLD in the literature being within the acceptable threshold of < 10 mm, some patients still report dissatisfaction, leading to litigation against orthopedic surgeons. However, lower extremity lengthening is sometimes necessary to achieve adequate hip joint stability and prevent dislocations. The purpose of this study was to compare LLD in patients undergoing THA using three different techniques: conventional anterior-approach THA (ATHA), conventional posterior-approach THA (PTHA), and robotic-assisted posterior-approach THA (RTHA) using the MAKO™ robotic hip system. Materials and Methods:. All cases of RTHA, ATHA and PTHA that were performed by the senior surgeon between Sep 2008 and Dec 2012 were reviewed. Patients included in this study had a primary diagnosis of hip osteoarthritis, with available and proper post-operative antero-posterior pelvis radiographs. All radiographs were calibrated and measurements done twice by two blinded observers. Results:. After exclusions, 67 RTHA cases, 29 ATHA cases and 59 PTHA cases were included in this study. There was a strong inter- and intra-observer correlation for all LLD measurements (r > 0.9, p < 0.001 in all). Mean LLD in the RTHA, ATHA and PTHA groups was 2.7 ± 1.8 mm (CI. 95. : 2.3, 3.2), 1.8 ± 1.6 mm (CI. 95. : 1.2, 2.4) and 1.9 ± 1.6 mm (CI. 95. : 1.5, 2.4) respectively (p = 0.01). When LLD > 3 mm was set as an outlier, the percentage of patients in the RTHA, ATHA and PTHA groups was 37.3%, 17.2% and 22% respectively (p value range, 0.06–0.78). When LLD > 5 mm was set as an outlier, the percentage of patients in the RTHA, ATHA and PTHA groups was 10.4%, 6.9% and 8.5% respectively (p value range, 0.72–1.0). None of the patients in all three groups had LLD ≥ 10 mm (Figure 1). Conclusion:. The results of the current study demonstrate the accuracy of the MAKO™ system in obtaining minimal LLD compared to the conventional anterior-approach and conventional posterior-approach THA, with no cases having LLD > 10 mm


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 22 - 22
1 Nov 2017
Dabis J Shaw T Hutt J Ward D Field R Mitchell P Sandiford A
Full Access

Introduction. Instability accounts for one third of revision total hip arthroplasty(rTHA) performed in the United Kingdom. Removal of well-fixed femoral stems in rTHA is challenging with a risk of blood loss and iatrogenic damage to the femur. The Bioball Universal Adaptor (BUA) (Merete, Germany), a modular head neck extension adaptor, provides a mechanism for optimisation of femoral offset, leg length and femoral anteversion. This can avoid the need for femoral stem revision in selected cases. There is a relative paucity of clinical data available with the use of this device. Aim. The aim of this study is to present the clinical results and rate of instability following revision with this head neck adaptor at a minimum of two years' follow up. Patients and Methods. A review of our prospectively collected database was performed. All patients treated with the Bioball device were included. Clinical and radiologic review were performed pre- and post-surgery. Specific enquiry for instability was made. The Oxford Hip Score (OHS), Euro-Quol (EQ-5D) score and WOMAC scores were calculated pre-and post-operatively. Complications were recorded. Statistical analysis using a Students t-test with a significance level of p<0.05 was considered to be statistically significant. Results. Thirty-two rTHA procedures were performed using the Bioball device between 2013 and 2016. Four patients did not wish to complete post-operative questionnaires. These had no complaints regarding their revised hips and were functioning well. Two patients (2/28, 7%) complained of recurrent dislocations following their rTHA procedure. One patient complained of instability but no dislocation. The median pre-operative EQ-5D was 0.195 (range −0.07 to 0.85), OHS was 20 (range 5 to 43) and WOMAC was 29.8 (range 15.5 to 52.3). The median EQ-5D was 0.85 (range 0.59 to 1), OHS was 39 (range 21 to 48) and WOMAC was 91.1 (range 44.5 to 99.2) at final follow up. There were significant improvements in the EQ-5D (p = 0.0009), OHS (p = 0.0004) and WOMAC (p = 0.0001). Conclusion. The Bioball Head Neck Adaptor is associated with significant functional improvement and relatively low dislocation rates in revision THA. It is a viable option for use in the revision setting


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 26 - 26
1 Apr 2019
Smulders K Bongers J Nijhof M
Full Access

Aim. The aim of this study is to evaluate if obesity negatively affects: (1) complication rate, (2) reoperation and revision rate and (3) functional outcome (based on patient reported outcome measures, PROMs) in revision total hip arthroplasty (rTHA). To our knowledge this is the only recent study to prospectively review these three aspects in what might be considered challenging rTHA. Methods. 444 rTHAs (cup, stem, both, n= 265, 57, 122 respectively), performed in a specialized high-volume orthopaedic center from 2013 to 2015, were prospectively followed. Complications and Oxford Hip Score (OHS) were evaluated at 4 months, 1 year and 2 years. Thirtyfour patients had a BMI >35 kg/m2 (obese), of which thirteen patients with a BMI >40 kg/m2 (morbidly obese). Results. Infection following rTHA was more common in obese patients (8/34: 24%) and in morbidly obese patients (5/13: 38%) than in non-obese patients (15/410: 4%; p's < 0.001). No differences between obese and non-obese groups for other complications were observed (aseptic loosening, dislocation, periprosthetic fractures, thromboembolic events). Reoperation and revision rates were similar overall (p = 0.067 / 0.303 respectively) and due to infection (p = 0.469 / 0.879 respectively) for obese and non-obese groups. Scores on the OHS improved from 42 ±13 at baseline to 27±12 at 1 and 2 year follow-up (p < 0.001). Obese patients had overall poorer OHS scores than non-obese patients (p < 0.001), but improvement of OHS did not differ between obese and non-obese patients (p = 0.198). Conclusion. Obesity is associated with an increased risk of infection following revision THA. Patients with high BMI should be counselled appropriately before surgery


Bone & Joint Open
Vol. 2, Issue 9 | Pages 721 - 727
1 Sep 2021
Zargaran A Zargaran D Trompeter AJ

Aims

Orthopaedic infection is a potentially serious complication of elective and emergency trauma and orthopaedic procedures, with a high associated burden of morbidity and cost. Optimization of vitamin D levels has been postulated to be beneficial in the prevention of orthopaedic infection. This study explores the role of vitamin D in orthopaedic infection through a systematic review of available evidence.

Methods

A comprehensive search was conducted on databases including Medline and Embase, as well as grey literature such as Google Scholar and The World Health Organization Database. Pooled analysis with weighted means was undertaken.