Aims. The first metatarsal
Aims. To determine the effectiveness of
A
The aim of this study was to determine the effect
of a Galeazzi fracture on the strength of
Excessive foot
Purpose: To ascertain whether the methods of
Purpose: In slipped capital femoral epiphysis (SCFE) with increasing slip angle and increasing impingement, pain, stiffness, limping and degenerative change may follow. Currently there are no accepted guidelines to guide management in patients with stable SCFE. The main purpose of this study was to evaluate the proximal femoral geometry in stable SCFE using a postero-anterior radiograph of the hip in the extended position and to determine its use in predicting subsequent surgical management. Methods: Over a 7 year period, we evaluated the proximal femoral geometry in a consecutive series of 31 adolescents with stable SCFE using the
We have assessed the influence of isolated and combined rotational malunion of the radius and ulna on the rotation of the forearm. Osteotomies were made in both the radius and the ulna at the mid-diaphyseal level of five cadaver forearms and stabilised with intramedullary metal implants. Malunion about the axis of the respective forearm bone was produced at intervals of 10°. The ranges of
Aims. Comparison of the outcome between the supine or
Most posterior hindfoot procedures have been
described with the patient positioned
Diagnostic interpretation error of paediatric musculoskeletal (MSK) radiographs can lead to late presentation of injuries that subsequently require more invasive surgical interventions with increased risks of morbidity. We aimed to determine the radiograph factors that resulted in diagnostic interpretation challenges for emergency physicians reviewing pediatric MSK radiographs. Emergency physicians provided diagnostic interpretations on 1,850 pediatric MSK radiographs via their participation in a web-based education platform. From this data, we derived interpretation difficulty scores for each radiograph using item response theory. We classified each radiograph by body region, diagnosis (fracture/dislocation absent or present), and, where applicable, the specific fracture location(s) and morphology(ies). We compared the interpretation difficulty scores by diagnosis, fracture location, and morphology. An expert panel reviewed the 65 most commonly misdiagnosed radiographs without a fracture/dislocation to identify normal imaging findings that were commonly mistaken for fractures. We included data from 244 emergency physicians, which resulted in 185,653 unique radiograph interpretations, 42,689 (23.0%) of which were diagnostic errors. For humerus, elbow, forearm, wrist, femur, knee, tibia-fibula radiographs, those without a fracture had higher interpretation difficulty scores relative to those with a fracture; the opposite was true for the hand, pelvis, foot, and ankle radiographs (p < 0 .004 for all comparisons). The descriptive review demonstrated that specific normal anatomy, overlapping bones, and external artefact from muscle or skin folds were often mistaken for fractures. There was a significant difference in difficulty score by anatomic locations of the fracture in the elbow, pelvis, and ankle (p < 0 .004 for all comparisons). Ankle and elbow growth plate, fibular avulsion, and humerus condylar were more difficult to diagnose than other fracture patterns (p < 0 .004 for all comparisons). We identified actionable learning opportunities in paediatric MSK radiograph interpretation for emergency physicians. We will use this information to design targeted education to referring emergency physicians and their trainees with an aim to decrease delayed and missed paediatric MSK injuries.
Diagnostic interpretation error of paediatric musculoskeletal (MSK) radiographs can lead to late presentation of injuries that subsequently require more invasive surgical interventions with increased risks of morbidity. We aimed to determine the radiograph factors that resulted in diagnostic interpretation challenges for emergency physicians reviewing pediatric MSK radiographs. Emergency physicians provided diagnostic interpretations on 1,850 pediatric MSK radiographs via their participation in a web-based education platform. From this data, we derived interpretation difficulty scores for each radiograph using item response theory. We classified each radiograph by body region, diagnosis (fracture/dislocation absent or present), and, where applicable, the specific fracture location(s) and morphology(ies). We compared the interpretation difficulty scores by diagnosis, fracture location, and morphology. An expert panel reviewed the 65 most commonly misdiagnosed radiographs without a fracture/dislocation to identify normal imaging findings that were commonly mistaken for fractures. We included data from 244 emergency physicians, which resulted in 185,653 unique radiograph interpretations, 42,689 (23.0%) of which were diagnostic errors. For humerus, elbow, forearm, wrist, femur, knee, tibia-fibula radiographs, those without a fracture had higher interpretation difficulty scores relative to those with a fracture; the opposite was true for the hand, pelvis, foot, and ankle radiographs (p < 0 .004 for all comparisons). The descriptive review demonstrated that specific normal anatomy, overlapping bones, and external artefact from muscle or skin folds were often mistaken for fractures. There was a significant difference in difficulty score by anatomic locations of the fracture in the elbow, pelvis, and ankle (p < 0 .004 for all comparisons). Ankle and elbow growth plate, fibular avulsion, and humerus condylar were more difficult to diagnose than other fracture patterns (p < 0 .004 for all comparisons). We identified actionable learning opportunities in paediatric MSK radiograph interpretation for emergency physicians. We will use this information to design targeted education to referring emergency physicians and their trainees with an aim to decrease delayed and missed paediatric MSK injuries.
Introduction: Energy storing tendons, such as the human Achilles tendon, suffer a much higher incidence of rupture than non- energy storing positional tendons, such as the anterior tibialis tendon. Similarly, in the horse partial rupture of the energy storing superficial digital flexor tendon (SDFT) and suspensory ligament (SL) occurs much more frequently than to the deep digital flexor tendon (DDFT) and common digital extensor tendon (CDET) which are not involved in energy storage. In order to function effectively, energy storing tendons experience strains during high speed locomotion which are much closer to failure strain than non-energy storing tendons. Therefore, these tendons are likely to sustain high levels of microdamage, hence cell metabolism may also be higher in order to repair damage and maintain matrix integrity. Maintenance of the matrix requires not only synthesis of new matrix components but also degradation of matrix macromolecules which is achieved, in part, by a family of matrix metalloproteinase enzymes (MMPs). In this study we test the hypothesis that the energy storing equine SDFT and SL which are
Aims. First metatarsal Pronation is increasingly recognised as an important component of Hallux valgus (HV) and can contribute towards intraoperative malreduction, postoperative recurrence and patient reported outcome measures (1,2,3). There are numerous radiological ways to measure metatarsal rotation on plain radiographs and weight bearing CT (WBCT), however there are no clinical tests to evaluate metatarsal
Aims. To evaluate how fore- and midfoot coronal plane alignment differs in feet with hallux valgus (HV), using 3DCT when measured in standard weightbearing (SWB) versus sesamoid view (SV) position, and to determine whether first metatarsophalangeal (MTP) dorsiflexion affects the relationship between the first metatarsal (M1) head and the sesamoid bones. Methods. A consecutive series of 34 feet that underwent 3DCT in SWB and SV positions for symptomatic HV was assessed, of which four feet were excluded for distorted or incomplete images. Two foot and ankle clinicians independently digitized a series of points, and measured a series of angles according to a pre-defined protocol. Measurements include navicular
Aims. The distal metatarsal metaphyseal articular angle (DMMA) is a measurement used in the surgical decision making of hallux valgus correction. However, it is difficult to measure on plain radiographs, is subject to projection bias, and its role in pathology is unclear. With the advent of weight-bearing CT (WBCT), our understanding of hallux valgus as a multiplanar deformity has evolved. The aim of this study was to investigate whether there is a relationship between the DMAA and
Aims. The aim of this study was to assess and compare active rotation of the forearm in normal subjects after the application of a short-arm cast (SAC) in the semisupination position and a long-arm cast (LAC) in the neutral position. A clinical study was also conducted to compare the functional outcomes of using a SAC in the semisupination position with those of using a LAC in the neutral position in patients who underwent arthroscopic triangular fibrocartilage complex (TFCC) foveal repair. Methods. A total of 40 healthy right-handed volunteers were recruited. Active