Advertisement for orthosearch.org.uk
Results 1 - 20 of 50
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 371 - 376
1 Mar 2008
Falkinstein Y Ahlmann ER Menendez LR

We report our early experience with a new peri-acetabular reconstruction endoprosthesis used for pelvic reconstruction after tumour resection. The outcome of 21 patients who underwent limb salvage following type II pelvic resection and reconstruction using the peri-acetabular reconstruction prosthesis between 2000 and 2006 was retrospectively reviewed. This prosthesis was designed to use the remaining part of the ilium to support a horizontally placed acetabular component secured with internal fixation and bone cement. Into this device a constrained acetabular liner is positioned which is articulates with a conventional femoral component to which a modular extension and modular head are attached. The mean follow-up was 20.5 months (1 to 77). The most common complications were deep infection, superficial wound infections, and dislocation. The mean musculoskeletal tumor society functional outcome score for the survivors was 20.1(11 to 27). We recommend the use of the peri-acetabular reconstruction prosthesis for reconstruction of large defects after type II pelvic resection, as this design has a greater inherent stability over other available prostheses


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 298 - 298
1 Sep 2005
Beadel G Griffin A Bell R Wunder J Aljassir F Turcotte R Iannuzzi D Isler M
Full Access

Introduction and Aims: The management of bone defects created by Type 1 pelvic resections of large iliac bone tumors remains controversial. We reviewed the functional and oncologic outcome following Type I resection with and without bone reconstruction. Method: A retrospective review of our prospectively collected database was undertaken analysing functional and oncological outcome of 16 patients with Type I pelvic resections. Minimum follow-up was 12 months (range 12–96 months). Outcome data was available on eight of 10 patients managed without reconstruction (WOR), with the residual ilium allowed to collapse back onto the sacrum, and on five of six patients with bone graft reconstruction (WR). Functional outcome was assessed by the Toronto Extremity Salvage score (TESS) and the Musculoskeletal Tumor Society scores (MSTS87 and MSTS93). Results: Average age at surgery was 33 years (WOR) and 48 years (WR), (p=0.04), with average maximal tumor dimensions of 12cm and 9cm respectively (p=0.1). The most frequent diagnosis was chondrosarcoma. The WOR group average TESS, MSTS 87 and MSTS 93 scores were respectively 73%, 18/35 and 58% at an average of 50 months (range 24–96 months) compared to 69%, 21/35 and 51% at an average of 37 months (range 12–60 months) for the WR group. Thirty-three percent of WOR and 20% of WR patients did not require walking aids. Infection or wound necrosis occurred in 40% of WOR patients and 50% of WR patients. No local recurrences were identified. Conclusion: Similar functional and oncologic outcome was achieved in both groups suggesting that bone reconstruction is not justified following Type I pelvic resection


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 89 - 89
1 Mar 2008
Beadel G Griffin A Aljassir F Iannuzzi D Turcotte R Isler M Bell R Wunder J
Full Access

A retrospective review of our prospectively collected database was undertaken and the functional and oncologic outcomes after Type One pelvic resections for bone tumours of the ilium and sacrum were analyzed. Seventeen patients were identified with a minimum followup after resection of twelve months. In seven patients the bone defect was reconstructed, with no reconstruction in the remaining ten patients. The functional/oncologic outcomes of the two groups are similar, however patients without reconstruction had fewer complications and less dependence on walking aids suggesting that reconstruction may not be justified. Management of defects created by Type One pelvic resections of large iliac bone tumours remains controversial. We reviewed the functional/oncologic outcome following resection with and without reconstruction. Similar functional/oncologic outcome was achieved in both groups suggesting that reconstruction is not justified. A retrospective review of our prospectively collected database was undertaken analyzing functional/oncological outcome of seventeen patients with Type One pelvic resection. Minimum follow up was twelve months (12–96). Outcome data was available on 8/10 patients managed without reconstruction (WOR), with residual ilium collapsing back onto sacrum, and on 5/7 patients with bone graft reconstruction (WR). Average age thirty-three years (WOR) and 48yrs (WR), (p=0.04), with average maximal tumour dimensions of 12cm and 9cm (p=0.1). The most frequent diagnosis was chondrosarcoma. The WOR group average TESS, MSTS 87 and MSTS 93 scores were respectively 73%, 18/35 and 58% at an average of 50 months (24–96) compared to 69%, 21/35 and 51% at an average of 37 months (12–60) for the WR group. 33% of WOR and 20% of WR patients did not require walking aids. Infection or wound necrosis occurred in 40% of WOR patients and 57% of WR patients. No local recurrences. The perceived advantages of no reconstruction are shorter operating times, reduced incidence of complications and improved functional outcome due to medialization of the weightbearing axis in the absence of hip abductors. The oncologic/functional outcomes of both groups were similar but in those not reconstructed there was a lower incidence of complications and walking aids


Bone & Joint 360
Vol. 13, Issue 5 | Pages 42 - 44
1 Oct 2024

The October 2024 Oncology Roundup. 360. looks at: Composite reconstruction: is it the answer for pelvic resections?; Can the cartilaginous thickness determine the risk of malignancy in pelvic cartilaginous tumours, and how accurate is the preoperative biopsy of these tumours?; Incidence and survival outcomes of patients with high-grade appendicular bone sarcoma and isolated regional lymph node metastasis; Improved metastatic-free survival after systematic re-excision following complete macroscopic unplanned excision of limb or trunk soft-tissue sarcoma; UK guidelines for the management of soft-tissue sarcomas; Current management of desmoid tumours: a review


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 271 - 275
1 Mar 1987
Thomas I Cole W Waters K Menelaus M

Seven patients with Ewing's sarcoma of the pelvis were treated by chemotherapy followed by wide resection of the primary tumour. Although good function after operation is possible, survival in this series reflects the poor prognosis associated with the disease; two patients died, two are alive with local recurrence and metastases and three patients are alive with no evidence of disease.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 115 - 115
1 Mar 2008
Fawzi A Beadle G Torcotte R Bill R Wounder J Isler M
Full Access

We evaluate the outcome (Functional, Oncological, and complications) after resection of pelvic sarcoma and reconstruction with the saddle prosthesis. Twenty-seven patients with a mean follow up of forty-five months. Fourteen patients were free of disease, eleven patients were deceased, and two patients were alive with disease. MSTS 93 was 51 %, MSTS 87 was15%, and TESS was 64 %. Infection occurred in ten, fracture in six, and dislocation in six patients. Vertical migration stabilized after two years. Five patients were retired, five had full-time employment, six were disabled, and eleven were deceased. Reconstruction with saddle prosthesis following resection for pelvic sarcoma is associated with significant morbidity. Treatment of pelvic sarcoma is difficult. Of many techniques described for reconstruction of the pelvis following tumor resection, limited data exists to compare functional results. To evaluate the outcome after resection of pelvic sarcoma and reconstruction with the saddle prosthesis. This retrospective study includes twenty-seven patients who underwent saddle prosthetic reconstruction for pelvic sarcoma. Functional outcome was assessed with MSTS 1987 & 1993 and the Toronto Extremity Salvage Score (TESS). Oncological outcome parameters and complications were recorded. We reviewed twenty-seven patients with a mean follow up of forty-five months. Seven (26%) patients underwent type II (periacetabular) pelvic resection, twenty had type II & III (periacetabular and pubis). Eleven patients received chemotherapy. None received radiation. Fourteen patients were free of disease, eleven patients were deceased, and two patients were alive with disease. The survival rate was 60%, 22% had local recurrence, and 22% had metastasis. Functional evaluation was completed in seventeen patients and the mean for MSTS 93 was 50.8 %, the MSTS 87 was15.3%, and the TESS was 64.4 %. Infection occurred in ten cases, and there were five nerve palsies. Heterotopic ossification occurred in ten, fracture in six, and dislocation in six patients. Limb shortening was initially progressive but stabilized after two years and ultimately ranged between one and six centimeters. Five patients were retired, five had full-time employment, six were disabled, and eleven were deceased. Reconstruction with saddle prosthesis following resection for pelvic sarcoma is associated with significant morbidity. However the functional results appear to confer an advantage when compared to the significant disability following hemipelvectomy


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 267 - 275
1 Feb 2017
Liang H Ji T Zhang Y Wang Y Guo W

Aims

The aims of this retrospective study were to report the feasibility of using 3D-printing technology for patients with a pelvic tumour who underwent reconstruction.

Patients and Methods

A total of 35 patients underwent resection of a pelvic tumour and reconstruction using 3D-printed endoprostheses between September 2013 and December 2015. According to Enneking’s classification of bone defects, there were three Type I lesions, 12 Type II+III lesions, five Type I+II lesions, two Type I+II+III lesions, ten type I+II+IV lesions and three type I+II+III+IV lesions. A total of three patients underwent reconstruction using an iliac prosthesis, 12 using a standard hemipelvic prosthesis and 20 using a screw-rod connected hemipelvic prosthesis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 56 - 56
1 Dec 2017
DePaolis N Romagnoli C Romantini M Frisoni T Donati D
Full Access

Reconstruction of pelvic bone defect after resection for bone tumours is a challenging procedure especially when the hip joint is involved due to the anatomy and the complex biomechanical and structural function of the pelvic ring. This surgery is associated to high complication rate. The additive 3D printing technology allows us to produce trabecular titanium custom based implants with an accurate planning of resection using bone cutting jigs.

From August 2013 to January 2017, we treated 8 patients for bone pelvic sarcoma with custom-made osteotomy jigs (Nylon) and custom-made trabecular titanium prosthesis produced through rapid prototyping technology based on mirroring of the contralateral hemipelvis. Mean follow up time was 18 months (range 2–30) Wide margins were obtained in all cases, in one a local recurrence developed. Surgical time was 4 hours average (from 180 to 250 mins). No postoperative complications were reported.

Rapid prototyping is a promising technique in order to achieve wide surgical margins and restore the anatomy in pelvic bone tumour resection as well as reducing complications.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 27 - 27
1 Nov 2022
Khan S Kapoor L Kumar V
Full Access

Abstract. Background. Conventional periacetabular pelvic resections are associated with poor functional outcomes. Resections through surgical corridors beyond the conventional margins may be helpful in retaining greater function without compromising the oncological margins. Methods. The study included a retrospective review of 82 cases of pelvic resections for pelvic tumors. Outcomes of acetabulum preservation (Group A) were compared with complete acetabular resection (Group B). Also, we compared outcomes of Type I+half resections (Group 1) with Type I+II resections (Group 2), and Type III+half resections (Group 3) with Type II+III resections (Group 4). Results. Group A (n=44) had significantly better functional outcome than Group B(n=38) with average MSTS93 score 22.3 vs 20.1 and average HHS 91.3 vs 82.5 (p<0.001). Group 1(n=14) and Group 2(n=12) had similar functional outcomes (mean MSTS93 score 22.07 vs 21.58 (p=0.597) and mean HHS 90.37 vs 86.51 (p=0.205)). Group 3(n=11) had significantly better functional outcome than Group 4(n=17), with mean MSTS93 score 22.8 vs 19.7 (p<0.001) and mean HHS 92.3 vs 80.1 (p<0.001). Oncological outcomes were similar among the groups. Conclusion. Trans-acetabular pelvic resections provide functional benefit over conventional resections without compromising oncological margins. There is a need to revisit and revise the pelvic resection planes


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 779 - 787
1 Jun 2020
Gupta S Griffin AM Gundle K Kafchinski L Zarnett O Ferguson PC Wunder J

Aims. Iliac wing (Type I) and iliosacral (Type I/IV) pelvic resections for a primary bone tumour create a large segmental defect in the pelvic ring. The management of this defect is controversial as the surgeon may choose to reconstruct it or not. When no reconstruction is undertaken, the residual ilium collapses back onto the remaining sacrum forming an iliosacral pseudarthrosis. The aim of this study was to evaluate the long-term oncological outcome, complications, and functional outcome after pelvic resection without reconstruction. Methods. Between 1989 and 2015, 32 patients underwent a Type I or Type I/IV pelvic resection without reconstruction for a primary bone tumour. There were 21 men and 11 women with a mean age of 35 years (15 to 85). The most common diagnosis was chondrosarcoma (50%, n = 16). Local recurrence-free, metastasis-free, and overall survival were assessed using the Kaplan-Meier method. Patient function was evaluated using the Musculoskeletal Tumour Society (MSTS) and Toronto Extremity Salvage Score (TESS). Results. At a mean follow-up of 159 months (1 to 207), 23 patients were alive without disease, one was alive with lung metastases, one was alive following local recurrence, four were dead of disease, and three had died from other causes. The overall ten-year survival was 77%. There was only one (3%) local recurrence, which occurred at 26 months. There were 18 complications in 17 patients; 13 wound healing complications/infections, three fractures, one pulmonary embolism, and one dislocation of the hip. Most complications occurred early. The mean functional scores were 21.1 (SD 8.1) for MSTS-87, 67.3 (SD 23.9) for MSTS-93 and 76.2 (SD 20.6) for TESS. Conclusion. Patients requiring Type I or Type I/IV pelvic resections can expect a good oncological outcome and a high rate of local control. Complications are generally acute in nature and are easily manageable. These patients achieved a good functional outcome without the need for bony reconstruction. Cite this article: Bone Joint J 2020;102-B(6):779–787


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 382 - 390
1 Feb 2021
Wang H Tang X Ji T Yan T Yang R Guo W

Aims. There is an increased risk of dislocation of the hip after the resection of a periacetabular tumour and endoprosthetic reconstruction of the defect in the hemipelvis. The aim of this study was to determine the rate and timing of dislocation and to identify its risk factors. Methods. To determine the dislocation rate, we conducted a retrospective single-institution study of 441 patients with a periacetabular tumour who had undergone a standard modular hemipelvic endoprosthetic reconstruction between 2003 and 2019. After excluding ineligible patients, 420 patients were enrolled. Patient-specific, resection-specific, and reconstruction-specific variables were studied using univariate and multivariate analyses. Results. The dislocation rate was 9.3% (n = 41). Dislocation was most likely to occur in the first three months after surgery. Four independent risk factors were found, one of which was older age at operation (p = 0.039). The odds ratios (ORs) of those aged ≥ 60 years and 30 to 60 years were 8.50 and 4.64, respectively, compared with those aged < 30 years. The other three risk factors were resection of gluteus maximus (p = 0.010, OR = 5.8), vertical shift of the centre of rotation (COR) of the hip by ≥ 20 mm (p = 0.008, OR = 3.60), and a type I+II+III pelvic resection (p = 0.014, OR = 3.04). Conclusion. Hemipelvic endoprosthetic reconstruction after resection of a periacetabular tumour has a dislocation rate of 9.3% (n = 41). Patients are most likely to dislocate in the first three months after surgery. The risk is increased for older patients (especially those aged > 60 years) and for those with gluteus maximus resection, vertical shift of the COR ≥ 20 mm, and a type I+II+III pelvic resection. Cite this article: Bone Joint J 2021;103-B(2):382–390


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 10 - 10
1 Dec 2022
Rizkallah M Ferguson P Basile G Werier JM Kim P Wilson D Turcotte R
Full Access

The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17–86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 96 - 96
1 Dec 2022
Rizkallah M Ferguson P Basile G Werier JM Kim P Wilson D Turcotte R
Full Access

The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17-86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1743 - 1751
1 Dec 2020
Lex JR Evans S Cool P Gregory J Ashford RU Rankin KS Cosker T Kumar A Gerrand C Stevenson J

Aims. Malignancy and surgery are risk factors for venous thromboembolism (VTE). We undertook a systematic review of the literature concerning the prophylactic management of VTE in orthopaedic oncology patients. Methods. MEDLINE (PubMed), EMBASE (Ovid), Cochrane, and CINAHL databases were searched focusing on VTE, deep vein thrombosis (DVT), pulmonary embolism (PE), bleeding, or wound complication rates. Results. In all, 17 studies published from 1998 to 2018 met the inclusion criteria for the systematic review. The mean incidence of all VTE events in orthopaedic oncology patients was 10.7% (1.1% to 27.7%). The rate of PE was 2.4% (0.1% to 10.6%) while the rate of lethal PE was 0.6% (0.0% to 4.3%). The overall rate of DVT was 8.8% (1.1% to 22.3%) and the rate of symptomatic DVT was 2.9% (0.0% to 6.2%). From the studies that screened all patients prior to hospital discharge, the rate of asymptomatic DVT was 10.9% (2.0% to 20.2%). The most common risk factors identified for VTE were endoprosthetic replacements, hip and pelvic resections, presence of metastases, surgical procedures taking longer than three hours, and patients having chemotherapy. Mean incidence of VTE with and without chemical prophylaxis was 7.9% (1.1% to 21.8%) and 8.7% (2.0% to 23.4%; p = 0.11), respectively. No difference in the incidence of bleeding or wound complications between prophylaxis groups was reported. Conclusion. Current evidence is limited to guide clinicians. It is our consensus opinion, based upon logic and deduction, that all patients be considered for both mechanical and chemical VTE prophylaxis, particularly in high-risk patients (pelvic or hip resections, prosthetic reconstruction, malignant diagnosis, presence of metastases, or surgical procedures longer than three hours). Additionally, the surgeon must determine, in each patient, if the risk of haemorrhage outweighs the risk of VTE. No individual pharmacological agent has been identified as being superior in the prevention of VTE events. Cite this article: Bone Joint J 2020;102-B(12)1743:–1751


Bone & Joint Open
Vol. 5, Issue 4 | Pages 260 - 268
1 Apr 2024
Broekhuis D Meurs WMH Kaptein BL Karunaratne S Carey Smith RL Sommerville S Boyle R Nelissen RGHH

Aims. Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions. Methods. A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed. Results. CTAC positioning was generally accurate, with minor deviations in cup inclination (mean 2.7°; SD 2.84°), anteversion (mean 3.6°; SD 5.04°), and rotation (mean 2.1°; SD 2.47°). Deviation of the hip centre of rotation (COR) showed a mean vector length of 5.9 mm (SD 7.24). Flange positions showed small deviations, with the ischial flange exhibiting the largest deviation (mean vector length of 7.0 mm; SD 8.65). Overall, 83% of the implants were accurately positioned, with 17% exceeding malpositioning thresholds. CTACs used in tumour resections exhibited higher positioning accuracy than rTHA cases, with significant differences in inclination (1.5° for tumour vs 3.4° for rTHA) and rotation (1.3° for tumour vs 2.4° for rTHA). The use of intraoperative navigation appeared to enhance positioning accuracy, but this did not reach statistical significance. Conclusion. This study demonstrates favourable CTAC positioning accuracy, with potential for improved accuracy through intraoperative navigation. Further research is needed to understand the implications of positioning accuracy on implant performance and long-term survival. Cite this article: Bone Jt Open 2024;5(4):260–268


Bone & Joint Research
Vol. 6, Issue 10 | Pages 577 - 583
1 Oct 2017
Sallent A Vicente M Reverté MM Lopez A Rodríguez-Baeza A Pérez-Domínguez M Velez R

Objectives. To assess the accuracy of patient-specific instruments (PSIs) versus standard manual technique and the precision of computer-assisted planning and PSI-guided osteotomies in pelvic tumour resection. Methods. CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student’s t-test and Mann–Whitney U test were used. Results. Compared with the manual technique, PSI-guided osteotomies improved accuracy by a mean 9.6 mm (p < 0.008) in the sacroiliac osteotomies, 6.2 mm (p < 0.008) and 5.8 mm (p < 0.032) in the biplanar supra-acetabular, 3 mm (p < 0.016) in the ischial and 2.2 mm (p < 0.032) and 2.6 mm (p < 0.008) in the parallel iliopubic osteotomies, with a mean linear deviation of 4.9 mm (p < 0.001) for all osteotomies. Of the manual osteotomies, 53% (n = 16) had a linear deviation > 5 mm and 27% (n = 8) were > 10 mm. In the PSI cases, deviations were 10% (n = 3) and 0 % (n = 0), respectively. For angular deviation from pre-operative plans, we observed a mean improvement of 7.06° (p < 0.001) in pitch and 2.94° (p < 0.001) in roll, comparing PSI and the standard manual technique. Conclusion. In an experimental study, computer-assisted planning and PSIs improved accuracy in pelvic tumour resections, bringing osteotomy results closer to the parameters set in pre-operative planning, as compared with standard manual techniques. Cite this article: A. Sallent, M. Vicente, M. M. Reverté, A. Lopez, A. Rodríguez-Baeza, M. Pérez-Domínguez, R. Velez. How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study. Bone Joint Res 2017;6:577–583. DOI: 10.1302/2046-3758.610.BJR-2017-0094.R1


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 321 - 322
1 Sep 2005
Yuen A Ek E Powell G Choong P
Full Access

Introduction and Aims: Improved survival has motivated aggressive surgery with musculoskeletal tumors. Pelvic resection is challenging because of the constraints of adjacent vital anatomy, and the considerable impact on limb and visceral function. The aims of this study was to assess the functional, oncologic and surgical outcomes following resections of the bony pelvis. Method: Between 1996 and 2003, 49 patients underwent tumor resections of the pelvic ring. The mean age was 43 (range 15–72) years. There were 44 primary (36 bone, nine soft tissue) and five secondary tumors. Of the bone tumors, there were six osteosarcomas, five Ewings sarcomas, 12 chondrosarcomas and 13 others. Of the soft tissue tumors, nine were of neural origin. Tumor locations included the ilium, periacetabulum, pubic bones, sacrum or combinations of these. Neoadjuvant chemotherapy (seven patients) and pre-operative radiotherapy (eight patients) were also used. Function was assessed using the American Musculoskeletal Tumor Society Functional scoring system. No patient had metastases at presentation. Results: Surgery – There were 40 limb sparing resections and nine hindquarter amputations. The surgical margins were intralesional (four), marginal (12), wide (28) and radical (five). Of the limb sparing surgery, prosthetic reconstructions were used in nine patients, biologic reconstructions in seven patients a combination of biologic and prosthetic reconstructions in three cases and no reconstructions in the others. The mean operating time was five (range 1.5–10) hours. The mean intra-operative blood loss was 10 (range 2–26) units. The average length of stay was 22 (range 2–110) days. Fifty percent of patients developed acute complications. Survival – There was one intra-operative death. There were nine local recurrences and 16 metastases. Death from disease occurred at a mean time of 13 (range 1–51) months. Mean follow-up was 28 (range 1–90) months. Functional assessment – Hind quarter amputation and periacetabular resections had the worse functional outcome. These accounted for almost 40% of all cases. Surprisingly, patients with periacetabular resections had the best score for emotional acceptance. Conclusion: Pelvic resections are complex, demanding and accompanied by a high complication rate. Surgery significantly affects functional outcome. Disease control is similar to limb tumors and medium to long-term survival is possible. Emotional acceptance of surgery in survivors was surprisingly high. Major pelvic resection for malignancy appears justifiable


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 57 - 57
1 Apr 2018
Hettwer W Petersen M
Full Access

Background. In certain clinical situations, complex local anatomy and limitations of surgical exposure can make adequate and bone tumor ablation, resection and reconstruction very challenging. We wished to review our clinical experience and accuracy achieved with entirely virtually planned single stage tumor ablation/resection and reconstructions. Methods. We report 6 cases of bone tumors in which tumor removal (by radio-frequency (RF) ablation and/or resection) and subsequent reconstruction were based entirely on pre-operative virtual analysis and planning. All interventions were accomplished with specifically designed and pre-operatively manufactured 3D-printed drill & resection guides. Immediate subsequent defect reconstruction was either performed with a precisely matching allograft (n=1) or composite metal implant (n=5) consisting of a defect specific titanium scaffold and multiple integrated fixation features to provide optimal immediate stability as well as subsequent opportunity for osseointegration. We reviewed the sequence of all procedural steps as well as the accuracy of each saw blade or drill trajectory by direct intra-operative measurement, post-operative margin status and virtual comparison of pre- and post-operative CT scans. Results. Intra-operative application/assembly of the resection guides could be accomplished with relative ease in all cases, permitting quick and efficient reproduction of the planned osteotomies as well as RF-probe trajectories with a high degree of accuracy. Histologically all resection margins were negative as planned except in one case where one pelvic resection was extended due to intraoperative concern of possible local tumor progression. All implants could be placed as planned, with post-operative imaging demonstrating satisfactory implant position. Virtual analysis of post-operative CT scans confirmeded minimal deviation of final implant position from the pre-operative plan. Conclusion. Reliable, accurate placement of tumor biopsy/ablation tracts and resection planes and their optimal alignment with respect to critical structures, tumor extent and desired preservation of unaffected bone is the most challenging and time consuming step during the analysis and planning phase. However it is also the crucial step with regard to subsequent design and production of clinically and oncologically meaningful case-specific drill/resection guides and implants. If these prerequisites are met, computer assisted virtual planning along with 3Dprinting-technology can afford high intraoperative accuracy, contribute to increased intra-operative surgeon confidence and decreased operative time


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 93 - 98
1 Jan 2024
Broida SE Tsoi KM Rose PS Ferguson PC Griffin AM Wunder JS Houdek MT

Aims

The sacroiliac joint (SIJ) is the only mechanical connection between the axial skeleton and lower limbs. Following iliosacral resection, there is debate on whether reconstruction of the joint is necessary. There is a paucity of data comparing the outcomes of patients undergoing reconstruction and those who are not formally reconstructed.

Methods

A total of 60 patients (25 females, 35 males; mean age 39 years (SD 18)) undergoing iliosacral resection were reviewed. Most resections were performed for primary malignant tumours (n = 54; 90%). The mean follow-up for surviving patients was nine years (2 to 19).


Bone & Joint 360
Vol. 13, Issue 2 | Pages 38 - 41
1 Apr 2024

The April 2024 Oncology Roundup360 looks at: Midterm outcomes of total hip arthroplasty after internal hemipelvectomy and iliofemoral arthrodesis; Intraosseous conventional central chondrosarcoma does not metastasize irrespective of grade in pelvis, scapula, and in long bone locations; Oncological and functional outcomes after resection of malignant tumours of the scapula; Reconstruction following oncological iliosacral resection – a comparison of techniques; Does primary tumour resection improve survival for patients with sarcomas of pelvic bones, sacrum, and coccyx who have metastasis at diagnosis?; Older patients with Ewing’s sarcoma: an analysis of the National Cancer Database; Diagnostic challenges in low-grade central osteosarcoma; Effect of radiotherapy on local recurrence, distant metastasis, and overall survival in 1,200 limb soft-tissue sarcoma patients: a retrospective analysis using inverse probability of treatment weighting-adjusted models.