External fixator knee arthrodesis is a salvage procedure mainly used in cases of end-stage infected total knee replacement (iTKR). A stable fixation combined with bone-ends compression is basic to achieve knee fusion in such a scenario but providing enough stability can be challenging in the presence of severe bone loss after multiple previous procedures. Compared with monoplanar configuration, a biplanar frame achieves improved coronal stiffness, while providing the advantages of good access to the wound and allowance of early ambulation. Our primary hypothesis stated that a biplanar frame would achieve higher and quicker fusion rate than a monolateral configuration. We conducted a retrospective cohort study examining patients managed with biplanar external fixator knee fusion due to non-revisable iTKR between 2014 and 2018. We compared this group of patients with a historical cohort-control patient who had been previously published by our unit in 2013, since we switched from a monoplanar to a biplanar configuration for the management of this kind of complex end-stage iTKR. Primary end-points were fusion rate, time to achieve bone fusion and infection eradication rate. Limb-length discrepancy, pain level, patient satisfaction, and health-related quality of life were also evaluated.Aim
Method
Aim. This study assessed quality of life (QoL) in patients having external fixation for treatment of osteomyelitis and fracture-related infection (OM/FRI). Method. Patients who had surgery for OM/FRI and who completed the EuroQoL EQ-5D-5L or EQ-5D- 3L questionnaires, were identified between 2010 and 2020. Patients were followed-up for 2 years after surgery. QoL was compared between patients who had either an Ilizarov frame or a
The aim of this paper is to describe the technique and evaluate the effectiveness of the RIA system in the first cases of bone loss treated by the authors with this technique. Between January 2010 and January 2011, ten patients were treated with an average age of fourty six years, with infected bone loss as a result of open fractures in various bone segments, with multiple failed treatment attempts, including three humeri, four femurs and three tibiae. The average size of the initial bone loss was 4 cm, varying from 1 to 8 cm. In 4 patients it was used simultaneously a Ilizarov apparatus with acute compression of the focus, in two patients a Ender pin and
Malformation and hypoplasia of the clavicle can result in pain, impaired function, restricted shoulder movement, subjective feeling of instability and cosmetic deformity. There are no reports of clavicle lengthening by osteotomy and distraction osteogenesis (DO). This is a retrospective review of 5 patients (7 clavicles) who underwent clavicle lengthening by DO using a
Excision of chronic osteomyelitic bone creates a dead space which must be managed to avoid early recurrence of infection. Systemic antibiotics cannot penetrate this space in high concentrations, so local treatment has become an attractive adjunct to surgery. The aim of this study was to present the mid- to long-term results of local treatment with gentamicin in a bioabsorbable ceramic carrier. A prospective series of 100 patients with Cierny-Mader Types III and IV chronic ostemyelitis, affecting 105 bones, were treated with a single-stage procedure including debridement, deep tissue sampling, local and systemic antibiotics, stabilization, and immediate skin closure. Chronic osteomyelitis was confirmed using strict diagnostic criteria. The mean follow-up was 6.05 years (4.2 to 8.4).Aims
Methods
The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients. A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications.Aims
Patients and Methods
Lengthening of the humerus is now an established
technique. We compared the complications of humeral lengthening
with those of femoral lengthening and investigated whether or not
the callus formation in the humerus proceeds at a higher rate than
that in the femur. A total of 24 humeral and 24 femoral lengthenings
were performed on 12 patients with achondroplasia. We measured the
pixel value ratio (PVR) of the lengthened area on radiographs and
each radiograph was analysed for the shape, type and density of
the callus. The quality of life (QOL) of the patients after humeral
lengthening was compared with that prior to surgery. The complication
rate per segment of humerus and femur was 0.87% and 1.37%, respectively.
In the humerus the PVR was significantly higher than that of the
femur. Lower limbs were associated with an increased incidence of
concave, lateral and central callus shapes. Humeral lengthening
had a lower complication rate than lower-limb lengthening, and QOL
increased significantly after humeral lengthening. Callus formation
in the humerus during the distraction period proceeded at a significantly
higher rate than that in the femur. These findings indicate that humeral lengthening has an important
role in the management of patients with achondroplasia.
Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications. Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult.
Femoral lengthening using the Intramedullary Skeletal Kinetic Distractor is a new technique. However, with intramedullary distraction the surgeon has less control over the lengthening process. Therefore, 33 femora lengthened with this device were assessed to evaluate the effect of operative variables under the surgeon’s control on the course of lengthening. The desired lengthening was achieved in 32 of 33 limbs. Problems encountered included difficulty in achieving length in eight femora (24%) and uncontrolled lengthening in seven (21%). Uncontrolled lengthening was more likely if the osteotomy was placed with less than 80 mm of the thick portion of the nail in the distal fragment (p = 0.052), and a failure to lengthen was more likely if there was over 125 mm in the distal fragment (p = 0.008). The latter problem was reduced with over-reaming by 2.5 mm to 3 mm. Previous intramedullary nailing also predisposed to uncontrolled lengthening (p = 0.042), and these patients required less reaming. Using the Intramedullary Skeletal Kinetic Distractor, good outcomes were obtained; problems were minimised by optimising the position of the osteotomy and the amount of over-reaming performed.