Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 5 - 5
1 Mar 2021
Kumar G Debuka E
Full Access

Increasing incidence of osteoporosis, obesity and an aging population have led to an increase in low energy hip fractures in the elderly. Perceived lower blood loss and lower surgical time, media coverage of minimal invasive surgery and patient expectations unsurprisingly have led to a trend towards intramedullary devices for fixation of extracapsular hip fractures. This is contrary to the Cochrane review of random controlled trials of intramedullary vs extramedullary implants which continues recommends the use of a sliding hip screw (SHS) over other devices. Furthermore, despite published literature of minimally invasive surgery (MIS) of SHS citing benefits such as reduced soft tissue trauma, smaller scar, faster recovery, reduced blood loss, reduced analgesia needs; the uptake of these approaches has been poor. We describe a novel technique one which remains minimally invasive, that not only has a simple learning curve but easily reproducible results. All patients who underwent MIS SHS fixation of extracapsular fractures were included in this study. Technique is shown in Figure 1. We collated data on all intertrochanteric hip fractures that were treated by a single surgeon series during period Jan 2014 to July 2015. Data was collected from electronic patient records and radiographs from Picture Archiving and Communication System (PACS). Surgical time, fluoroscopy time, blood loss, surgical incision length, post-operative transfusion, Tip Apex Distance (TAD) were analyzed. There were 10 patients in this study. All fractures were Orthopaedic Trauma Association (OTA) type A1 or A2. Median surgical time was 36 minutes (25–54). Mean fluoroscopy time was similar to standard incision sliding hip screw fixation. Blood loss estimation with MIS SHS can be undertaken safely and expeditiously for extracapsular hip fractures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 33 - 33
11 Apr 2023
Ruksakulpiwat Y Numpaisal P Jeencham R
Full Access

Currently, fibrin glue obtained from fibrinogen and thrombin of human and animal blood are widely investigated to use as injectable hydrogel for tissue engineering which contributes to minimally invasive surgery, superior biodegradability, cell attachment, proliferation and regenerating new tissue. However, most of them fail to achieve to be used for tissue engineering application because of a risk of immune response and poor mechanical properties. To overcome the limitation of fibrin glue and to reduce the usage of products from human and animal blood, the artificial fibrin glue materials were developed. Recently, cellulose nanofiber (CNF) as reinforcing agent has been explored for many tissue engineering applications such as bone and cartilage due to its impressive biological compatibility, biodegradability and mechanical properties. CNF was extracted from cassava pulp. PEO-PPO-PEO diacrylate block copolymer is a biodegradable synthetic polymers which is water insoluble hydrogel after curing by UV light at low intensity. To enhance the cell adhesion abilities, gelatin methacrylate (GelMA), the denature form of collagen was used to incorporate into hydrogel. The aim of this study was to develop the artificial fibrin glue from CNF reinforced PEO-PPO-PEO diacrylate block copolymer/GelMA injectable hydrogel. CNF/PEO-PPO-PEO diacrylate block copolymer/GelMA injectable hydrogels were prepared with 2-hydroxy-1-(4-(hydroxy ethoxy) phenyl)-2-methyl-1-propanone (Irgacure 2959) as a photoinitiator. The physicochemical properties were investigated by measuring various properties such as thickness, gel fraction, mechanical properties and water uptake. At optimal preparation condition, CNF reinforced injectable hydrogel was successful prepared after curing with UV light within 7 minutes. This hydrogel showed gel fraction and water uptake of 81 and 85%, respectively. The cytotoxicity, cell adhesion and proliferation of CNF reinforced injectable hydrogel was presented. Cellulose nanofiber from casava pulp was successfully used to prepare injectable hydrogel as artificial fibrin glue for tissue engineering. The hydrogel showed good physical properties which can be applied to use for tissue engineering application


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 110 - 110
1 Nov 2021
Ahmed M Barrie A Kozhikunnath A Thimmegowda A Ho S Kunasingam K Guryel E Collaborative M
Full Access

Introduction and Objective. Lower limb fractures are amongst the most common surgically managed orthopaedic injuries, with open reduction and internal fixation (ORIF) as the conventional method of treatment of the fibula. In recent years, dedicated intramedullary implants have emerged for fibula fixation in tandem with the move towards minimally invasive surgery in high-risk patients. This is the largest multicentre review to date with the aim of establishing the clinical outcomes following intramedullary nail (IMN) fixation of the fibula and to identify the absolute indication for fibula IMN fixation. Materials and Methods. A retrospective study of adult patients in all UK hospitals, who underwent fibula nail fixation between 01/01/2018 and 31/10/2020 was performed. Primary outcome measures included time to union, infection rate, other post-operative complications associated with the fixation and length of hospital stay. The secondary outcome measure was to identify the indication for fibula nailing. Data tabulation was performed using Microsoft Excel and analysis was performed using SPSS Version 23 (SPSS Statistics). Results. 2 Major Trauma Centres (MTCs) and 9 Trauma Units (TUs) were eligible for inclusion. 102 patients were included and 91% were classified as ankle fractures of 68% (n=69) were Weber B, 24% (n=24) Weber C and 8% (n=9) were either distal tibial fractures with an associated fibula fracture or pilon fractures. The mean age was 64 years of which 45 were male patients and 57 were female. The average BMI was 30.03kg/m. 2. and 44% of patients were ASA 3. 74% of patients had poor pre-op skin condition including swelling and open wounds. The calculated infection rate for fibula nail was 4.9% and metal-work complication rate was 4.9%. The average time to union was 13 weeks and length of inpatient stay was 15 days (SD +/− 12 days). Conclusions. MEFNO has demonstrated that fibula nail is an ideal implant in patients who have a physiologically higher risk of surgery, poor skin condition and a complex fracture pattern. The time to union, complication and infection risks are lower than that reported in literature for ankle ORIFs


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 121 - 121
1 Jan 2017
Girolami M Babbi L Gasbarrini A Barbanti Brodano G Bandiera S Terzi S Ghermandi R Boriani S
Full Access

Spinal infections are rare diseases, whose management highlights the importance of a multidisciplinary approach. Although treatment is based on antibiotics, always selected on coltural and antibiogram tests, surgery is required in case of development of spinal instability or deformity, progressive neurological deficits, drainage of abscesses, or failure of medical treatment. The first step of the algorithm is diagnosis, that is established on MRI with contrast, PET/CT scan, blood tests (CRP and ESR) and CT-guided needle biopsy. Evaluation of response to the specific antibiotic therapy is based on variations in Maximum Standardized Uptake Value (SUVmax) after 2 to 4 weeks of treatment. In selected cases, early minimally invasive surgery was proposed to provide immediate stability and avoid bed-rest. From 1997 to 2014, 182 patients affected by spinal infections have been treated at the same Institution (Istituto Ortopedico Rizzoli – Bologna, Italy) according to the proposed algorithm. Mean age was 56 years (range 1 – 88). Male to female ratio was 1.46. Minimum follow-up was 1 year. Infections were mostly located in the lumbar spine (57%) followed by thoracic (37%) and cervical spine (6%). Conservative treatment based on antibiotics needed surgery (open and/or percuteneous minimally invasive) as an adjuvant in 83 patients out of 182 (46%). Management of spinal infections still remains a challenge in spinal surgery and a multisciplinary approach is mandatory. This algorithm represents the shared decision- making process from diagnosis to the most appropriate treatment and it led to successful outcomes with a low-complication rate. We present this algorithm developed to organize the various professionals involved (orthopaedic surgeons, nuclear medicine and infective disease specialists, interventional radiologists and anaestesiologists) and set a shared pathway of decision making in order to uniform the management of this complex disease


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 25 - 25
1 Jan 2017
Shih K Lin C Lu H Lin C Lu T
Full Access

Total knee replacements (TKR) have been the main choice of treatment for alleviating pain and restoring physical function in advanced degenerative osteoarthritis of the knee. Recently, there has been a rising interest in minimally invasive surgery TKR (MIS-TKR). However, accurate restoration of the knee axis presents a great challenge. Patient-specific-instrumented TKR (PSI-TKR) was thus developed to address the issue. However, the efficacy of this new approach has yet to be determined. The purpose of the current study was thus to measure and compare the 3D kinematics of the MIS-TKR and PSI-TKR in vivo during sit-to-stand using a 3D fluoroscopy technology. Five patients each with MIS-TKR and PSI-TKR participated in the current study with informed written consent. Each subject performed quiet standing to define their own neutral positions and then sit-to-stand while under the surveillance of a bi-planar fluoroscopy system (ALLURA XPER FD, Philips). For the determination of the 3D TKR kinematics, the computer-aided design (CAD) model of the TKR for each subject was obtained from the manufacturer including femoral and tibial components and the plastic insert. At each image frame, the CAD model was registered to the fluoroscopy image via a validated 2D-to-3D registration method. The CAD model of each prosthesis component was embedded with a coordinate system with the origin at the mid-point of the femoral epicondyles, the z-axis directed to the right, the y-axis directed superiorly, and the x-axis directed anteriorly. From the accurately registered poses of the femoral and tibial components, the angles of the TKR were obtained following a z-x-y cardanic rotation sequence, corresponding to flexion/extension, adduction/abduction and internal/external rotation. During sit-to-stand the patterns and magnitudes of the translations were similar between the MIS-TKR and PSI-TKR groups, with posterior translations ranging from 10–20 mm and proximal translations from 29–31mm. Differences in mediolateral translations existed between the groups but the magnitudes were too small to be clinically significant. For angular kinematics, both groups showed close-to-zero abduction/adduction, but the PSI-TKR group rotated externally from an internally rotated position (10° of internal rotation) to the neutral position, while the MIS-TKR group maintained at an externally rotated position of less than 5° during the movement. During sit-to-stand both groups showed similar patterns and magnitudes in the translations but significant differences in the angular kinematics existed between the groups. While the MIS-TKR group maintained at an externally rotated position during the movement, the PSI-TKR group showed external rotations during knee extension, a pattern similar to the screw home mechanism in a normal knee, which may be related to more accurate restoration of the knee axis in the PSI-TKR group. A close-to-normal angular motion may be beneficial for maintaining a normal articular contact pattern, which is helpful for the endurance of the TKR. The current study was the first attempt to quantify the kinematic differences between PSI and non-PSI MIS. Further studies to include more subjects will be needed to confirm the current findings. More detailed analysis of the contact patterns is also needed


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 34 - 34
1 Mar 2012
Hasegawa M Kawamura G Wakabayashi H Sudo A Uchida A
Full Access

Introduction. Standard surgical exposure reduces blood flow to the patella during total knee arthroplasty (TKA). Reduction of patellar blood flow has resulted in patellofemoral complications including osteonecrosis and patellar fracture, necessitating revision surgery. Eversion of the patella is typically used to gain access to the knee joint in most TKA surgical approaches. More recently, the development of minimally invasive surgery (MIS) techniques has avoided patellar eversion by subluxing the patella. The present study is the first to measure patellar blood flow during MIS TKA with the knee in both extension and 90 degrees of flexion followed by lateral retraction and then eversion of the patella. Methods. Patellar blood flow was measured using laser Doppler flowmetry in 40 patients during MIS TKA. Patients included 32 women and 8 men who had a mean age of 73 years (range, 52 to 88 years) and a mean weight of 59 kg (39 to 85 kg). The pre-operative diagnoses were osteoarthritis in 36 patients and rheumatoid arthritis in four patients. All patients underwent MIS TKA using the mini-midvastus approach. After initial blood flow was assessed with the leg in full extension, further measurements were performed after lateral retraction and after eversion of the patella. Then, blood flow was assessed with the knee in 90 degrees of flexion followed by lateral retraction and then eversion of the patella. Results. For measurements made during knee extension, a significant reduction in flow was observed during eversion of the patella compared with the neutral patellar position (P < 0.001). However, no significant difference was found between lateral retraction of the patella and the neutral patellar position. A significant reduction in flow was noted when the leg was flexed from full extension to 90 degrees (P < 0.001). For measurements made with the knee in 90 degrees of flexion, a significant reduction in flow was observed during eversion of the patella (P = 0.002) and a significant increase was noted during lateral retraction of the patella compared with the neutral position (P < 0.001). Conclusion. Patella eversion may result in traction both on medial vessels and those within the quadriceps mechanism, whereas, lateral retraction reduces the force exerted on the arteries within the quadriceps after the medial blood supply was interrupted by medial arthrotomy. In addition, the position of the leg had a great impact on patellar blood flow. MIS TKA without patellar eversion may be useful for preventing a reduction in patellar blood flow


Bone & Joint Research
Vol. 6, Issue 8 | Pages 481 - 488
1 Aug 2017
Caruso G Bonomo M Valpiani G Salvatori G Gildone A Lorusso V Massari L

Objectives

Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years.

Methods

A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1317 - 1324
1 Sep 2010
Solomon LB Lee YC Callary SA Beck M Howie DW

We dissected 20 cadaver hips in order to investigate the anatomy and excursion of the trochanteric muscles in relation to the posterior approach for total hip replacement. String models of each muscle were created and their excursion measured while the femur was moved between its anatomical position and the dislocated position. The position of the hip was determined by computer navigation.

In contrast to previous studies which showed a separate insertion of piriformis and obturator internus, our findings indicated that piriformis inserted onto the superior and anterior margins of the greater trochanter through a conjoint tendon with obturator internus, and had connections to gluteus medius posteriorly. Division of these connections allowed lateral mobilisation of gluteus medius with minimal retraction. Analysis of the excursion of these muscles revealed that positioning the thigh for preparation of the femur through this approach elongated piriformis to a maximum of 182%, obturator internus to 185% and obturator externus to 220% of their resting lengths, which are above the thresholds for rupture of these muscles.

Our findings suggested that gluteus medius may be protected from overstretching by release of its connection with the conjoint tendon. In addition, failure to detach piriformis or the obturators during a posterior approach for total hip replacement could potentially produce damage to these muscles because of over-stretching, obturator externus being the most vulnerable.