Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 14 - 14
2 May 2024
Menakaya C Durand-Hill M Carrington R Hart A Donaldson J Miles J Briggs T Skinner J
Full Access

The management of femoral bone loss is challenging during revision hip arthroplasty. In patients with Paprosky grade IIIB and IV defects, obtaining fixation and rotational stability using traditional surgical constructs is difficult. The use of a custom-made internal proximal femoral replacement prostheses has been proposed as a solution in patients, with severe femoral bone stock loss. However, there is a paucity in the literature on their use and long-term outcomes. We report on the clinical and radiological results of our cohort. We retrospectively reviewed all patients who underwent internal proximal femoral replacement for revision hip arthroplasty between April 1996 and April 2019. All patients had at least 2 years of follow-up time. 160 patients underwent limb salvage at our institution using internal proximal femoral replacement. The mean follow-up was 79.7 months (S.D 41.3). Indications for revision included periprosthetic fractures, aseptic loosening, and deep infection. The mean Oxford hip score increased from 13.8 (0–22) to 31.5 (18–43) (paired t-test, p < 0.001). Kaplan-Meier prosthesis survival analysis with revision as the endpoint was 87% at 5 years. None required revision of the femoral stem. There were four dislocations (5%) and there was failure to eradicate the deep infection in four. This technique allows instant distal fixation, allowing for early mobilisation. Long-term clinical and radiological outcomes are encouraging and the complication rates are acceptable for this patient group


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1149 - 1157
1 Sep 2006
Khoo PPC Michalak KA Yates PJ Megson SM Day RE Wood DJ

Iontophoresis is a novel technique which may be used to facilitate the movement of antibiotics into the substance of bone using an electrical potential applied externally. We have examined the rate of early infection in allografts following application of this technique in clinical practice. A total of 31 patients undergoing revision arthroplasty or surgery for limb salvage received 34 iontophoresed sequential allografts, of which 26 survived for a minimum of two years. The mean serum antibiotic levels after operation were low (gentamicin 0.37 mg/l (0.2 to 0.5); flucloxacillin 1 mg/l (0 to 1) and the levels in the drains were high (gentamicin 40 mg/l (2.5 to 131); flucloxacillin 17 mg/l (1 to 43). There were no early deep infections. Two late infections were presumed to be haemotogenous; 28 of the 34 allografts were retained. In 12 patients with pre-existing proven infection further infection has not occurred at a mean follow-up of 51 months (24 to 82)


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 12 - 12
1 Jan 2018
De Martino I D'Apolito R Nocon A Sculco P Sculco TP Bostrom M
Full Access

Proximal femoral replacements are commonly used in oncologic limb salvage procedures. Recently, these megaprostheses have been utilized in complex revision arthroplasties where proximal femoral bone is compromised. The purpose of this study is to evaluate the clinical and radiographic survivorship of proximal femoral replacements as a salvage treatment for bone loss after hip arthroplasty. We retrospectively reviewed the clinical and radiographic outcomes of 31 proximal femoral replacements of a single design between 2004 and 2013 at a single institution. The mean age at time of index surgery was 62 years, 58% were female, and mean BMI was 28.1 Kg/m. 2. The indications and complications associated with megaprosthesis implantation were collected. Average follow-up was 60 months (range 24–120 months). Kaplan-Meier survivorship assessed clinical and radiographic survivorship. Indication for revision, use of a constrained liner and construct length were assessed as risk factors for construct failure. The indications for proximal femoral replacement were periprosthetic infection (n=12, 38.7%), aseptic loosening (n=10, 32.3%), periprosthetic fracture (n=6, 19.3%), and non-union (n=3, 9.7%). A constrained liner was used in 22 hips (71%). The average length of bone resection was 148 cm (range 81–240 cm). There were nine revisions (29.2%): 3 for infection (9.7%) 2 for dislocation (6.5%), 2 for aseptic loosening (6.5%), and 2 for periprosthetic fracture (6.5%). Two of the 3 infections were in patients treated for infection. Overall survivorship was at 70.8%. There was no relation between the length of the bone resection, indication for revision and failure rate. Proximal femoral replacement in non-oncologic revision hip arthroplasty demonstrated a high failure rate at 2–10 year follow-up. Despite the high failure rate, the benefits of this salvage construct are that they allow full weight-bearing and allow rapid mobilization with minimal morbidity


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 47 - 47
1 Jun 2016
Grammatopoulos G Alvand A Martin H Taylor A Whitwell D Gibbons M
Full Access

The management of proximal femoral bone loss is a significant challenge in revision hip arthroplasty. A possible solution is the use of a modular proximal femur endoprosthesis (EPR). Although the survivorship and functional outcome of megaprostheses used in tumour surgery has been well described, outcome of EPRs used in revision hip surgery has received less attention. The aim of this study was to determine the 5-year outcome following proximal femur EPR and determine factors that influence it. This was a retrospective consecutive case series of all EPRs (n=80) performed for non-neoplastic indications, by 6 surgeons, in our tertiary referral centre, between 2005–2014. Patient demographics and relevant clinical details were determined from notes. The most common indications for the use of EPRs included infection (n=40), peri-prosthetic fracture (n=12) and failed osteosynthesis of proximal femoral fractures/complex trauma (n=11). Outcome measures included complication and re-operation rates, implant survival and assessment of functional outcome using the Oxford-Hip-Score (OHS). The mean age at surgery was 69 years and mean follow-up was 4 (0 – 11) years. The mean number of previous hip operations was 2.4 (range: 0 – 17). Twenty-five patients sustained a complication (31%), the most common being infection (n=9) and dislocation (n=4). By follow-up, further surgery was required in 18 (22%) hips, 9 of which were EPR revisions. 5-yr implant survivorship was 87% (95%CI: 76 – 98%). Mean OHS was 28 (range: 4 – 48). Inferior survival and outcome were seen in EPRs performed for the treatment of infection. Infection eradication was achieved in 34/41 with the index EPR procedure and in 40/41 hips by follow-up. Limb salvage was achieved in all cases and acceptable complication- and re-operation rates were seen. EPRs for periprosthetic fractures and failed osteosynthesis had best outcome. We recommend the continued use of proximal femur EPR in complex revision surgery


Bone & Joint Open
Vol. 3, Issue 3 | Pages 229 - 235
11 Mar 2022
Syam K Unnikrishnan PN Lokikere NK Wilson-Theaker W Gambhir A Shah N Porter M

Aims

With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases.

Methods

A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS).


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 22 - 30
1 Jan 2018
Brown TS Salib CG Rose PS Sim FH Lewallen DG Abdel MP

Aims

Reconstruction of the acetabulum after resection of a periacetabular malignancy is technically challenging and many different techniques have been used with varying success. Our aim was to prepare a systematic review of the literature dealing with these techniques in order to clarify the management, the rate of complications and the outcomes.

Patients and Methods

A search of PubMed and MEDLINE was conducted for English language articles published between January 1990 and February 2017 with combinations of key search terms to identify studies dealing with periacetabular resection with reconstruction in patients with a malignancy. Studies in English that reported radiographic or clinical outcomes were included. Data collected from each study included: the number and type of reconstructions, the pathological diagnosis of the lesions, the mean age and follow-up, gender distribution, implant survivorship, complications, functional outcome, and mortality. The results from individual studies were combined for the general analysis, and then grouped according to the type of reconstruction.