Advertisement for orthosearch.org.uk
Results 1 - 20 of 21
Results per page:
Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 1 - 1
1 Sep 2012
Moideen AN Wolf C Donaldson O O'Doherty D
Full Access

Background. Exeter Trauma Stem (ETS) is a polished tapered collarless monopolar prosthesis used for cemented hemiarthroplasty for fracture neck of femur. Two modular rasps are available on the instrumentation set. The larger rasp, in practice, rarely fits into the femur making trial reduction impossible. Our hypothesis was that the absence of a trial reduction could affect leg length and stability of the prosthesis. Aim. To evaluate the leg length discrepancy following use of Exeter Trauma Stem for intracapsular fracture neck of femur. Methods. All patients who underwent ETS hemiarthroplasty between June 2009 to March 2010 (n = 100) were included in the study. Radiographic assessment of leg length was performed by two independent assessors based on measurements by Woolson et al. Results. Upto half of the patients had equal leg length measurements. Forty four patients had lengthening of the operated leg with a mean of 10mm (5–25). Further complications included four dislocations. There was no statistical significance between leg lengths and dislocations. Conclusion. Care is needed with regards to correct positioning of the ETS prosthesis to achieve equal leg lengths. Following this study a new intermediate sized modular rasp has been introduced to the instrumentation set


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims. The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN). Methods. The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications. Results. The mean length of time between the initial injury and surgery was 4.5 years (3 to 10). The mean operating time was 2.8 hours (2.05 to 4.4)), and the mean blood loss was 850 ml (650 to 1,020). Complications occurred in five patients (21.7%): two with wound necrosis, and three with deep vein thrombosis. The mean coronal deformity was significantly corrected from 17.78° (SD 4.62°) preoperatively to 1.35° (SD 1.72°) postoperatively (p < 0.001), and the mean sagittal deformity was significantly corrected from 20.65° (SD 5.88°) preoperatively to 1.61° (SD 1.95°; p < 0.001) postoperatively. The mean leg length discrepancy was significantly corrected from 3.57 cm (SD 1.27) preoperatively to 1.13 cm (SD 0.76) postoperatively (p < 0.001). All fractures healed at a mean of seven months (4 to 12) postoperatively. The mean Lower Extremity Functional Scale score improved significantly from 45.4 (SD 9.1) preoperatively to 66.2 (SD 5.5) postoperatively (p < 0.001). Partial cortical nonunion in the deformed segment occurred in eight patients (34.8%) and healed at a mean of 2.4 years (2 to 3) postoperatively. Conclusion. A clamshell osteotomy combined with IMN fixation in the treatment of patients with a femoral shaft fracture and a previous post-traumatic femoral malunion achieved excellent outcomes. Partial cortical nonunions in the deformed segment also healed satisfactorily. Cite this article: Bone Joint J 2023;105-B(4):449–454


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_17 | Pages 9 - 9
11 Oct 2024
Zace P Maas Z McIntyre R Khan Z Bailey O
Full Access

Increasing the accuracy of information provided through X-Rays maximises pre-operative planning. Aim of this project is to determine the necessity of calibration probes that would improve the accuracy of pre-operative templating. This is a retrospective study involving leg length and pelvis X-Rays performed across the NHS Lanarkshire from 01/03/2023 until 31/04/2024. A total of 87 leg length X-Rays were identified, 18 had a calibration probe present. Leg length was measured on each and the X-Rays were calibrated against the existing probe. In 66.7% of cases there was a major leg length discrepancy of over 2cm between the pre-calibrated and post-calibrated X-Rays. Pelvic X-Rays of 80 patients that underwent total hip replacement were reviewed. Preoperative templating was compared to the implants inserted. An average of 1.94 discrepancy in the size of the acetabular implant was identified whilst in 30 cases the size of the femoral stem was incorrect by at least 1 size. Magnification of 119.7% on X-Rays was found to provide the most accurate templating. Seventy seven cases of pelvic X-Rays before and after hip hemiarthroplasty were also reviewed. The implant head was templated incorrectly in 74% of cases and the stem in 51%. It was identified that pelvic X-Ray magnification of 121.7% would provide the most accurate results. X-Rays with no calibration probes provide inaccurate measurements leading to faulty preoperative planning. Standardised use of a calibration sphere is strongly suggested and whenever that is not available, we suggest magnification of 121%


Bone & Joint Research
Vol. 5, Issue 1 | Pages 18 - 25
1 Jan 2016
Sims AL Parsons N Achten J Griffin XL Costa ML Reed MR

Background. Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes. Design. This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset. Discussion. Evidence on the optimum choice of prosthesis for hemiarthroplasty of the hip is lacking. National guidance is currently based on expert opinion rather than empirical evidence. The incidence of hip fracture is likely to continue to increase and providing high quality evidence on the optimum treatment will improve patient outcomes and have important health economic implications. Cite this article: A. L. Sims. The World Hip Trauma Evaluation Study 3: Hemiarthroplasty Evaluation by Multicentre Investigation – WH. I. TE 3: HEMI – An Abridged Protocol. Bone Joint Res 2016;5:18–25. doi: 10.1302/2046-3758.51.2000473


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1399 - 1408
1 Oct 2017
Scott CEH MacDonald D Moran M White TO Patton JT Keating JF

Aims. To evaluate the outcomes of cemented total hip arthroplasty (THA) following a fracture of the acetabulum, with evaluation of risk factors and comparison with a patient group with no history of fracture. . Patients and Methods. Between 1992 and 2016, 49 patients (33 male) with mean age of 57 years (25 to 87) underwent cemented THA at a mean of 6.5 years (0.1 to 25) following acetabular fracture. A total of 38 had undergone surgical fixation and 11 had been treated non-operatively; 13 patients died at a mean of 10.2 years after THA (0.6 to 19). Patients were assessed pre-operatively, at one year and at final follow-up (mean 9.1 years, 0.5 to 23) using the Oxford Hip Score (OHS). Implant survivorship was assessed. An age and gender-matched cohort of THAs performed for non-traumatic osteoarthritis (OA) or avascular necrosis (AVN) (n = 98) were used to compare complications and patient-reported outcome measures (PROMs). Results. The mean time from fracture to THA was significantly shorter for patients with AVN (2.2 years) or protrusio (2.2 years) than those with post-traumatic OA (9.4 years) or infection (8.0 years) (p = 0.03). Nine contained and four uncontained defects were managed with autograft (n = 11), bulk allograft (n = 1), or trabecular metal augment (n = 1). Initial fracture management (open reduction and internal fixation or non-operative), timing of THA (> /< one year), and age (> /< 55 years) had no significant effect on OHS or ten-year survival. Six THAs were revised at mean of 12 years (5 to 23) with ten-year all-cause survival of 92% (95% confidence interval 80.8 to 100). THA complication rates (all complications, heterotopic ossification, leg length discrepancy > 10 mm) were significantly higher following acetabular fracture compared with atraumatic OA/AVN and OHSs were inferior: one-year OHS (35.7 versus 40.2, p = 0.026); and final follow-up OHS (33.6 versus 40.9, p = 0.008). . Conclusion . Cemented THA is a reasonable option for the sequelae of acetabular fracture. Higher complication rates and poorer PROMs, compared with patients undergoing THA for atraumatic causes, reflects the complex nature of these cases. Cite this article: Bone Joint J 2017;99-B:1399–1408


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 8 - 8
1 May 2019
Moriarty P Wong L Kearney D Harty J
Full Access

Revision hip arthroplasty presents a challenge in the setting of femoral bone loss. Tapered stems are susceptible to subsidence which leads to leg length inequality, hip instability and may necessitate repeat femoral revision surgery. The purpose of this study was to compare radiographic outcomes in two modular tapered revision systems with different distal stem geometries. We sought to establish the minimum postoperative stem bi-cortical contact length that predicts subsidence for tapered stems. This study examined revision total hip arthroplasties between 2009 and 2016 in a European university affiliated major trauma center. Modular stem A has a taper of 3 degrees whereas modular stem B has a taper of 2 degrees. Radiologic assessment compared x-rays at two time points: immediately post-surgery and most recent x-ray available at a minimum follow up of two years. Leg length discrepancy, subsidence and postoperative bi cortical contact was assessed. Descriptive summary statistics calculated clinical factors (i.e. age, gender, Paprosky classification). 122 arthroplasties were completed. Complete data was available for 112. Revisions were carried out for Paprovski grade 3a/ 3b femoral deficits. Post-operative bi-cortical contact of the proximal stem < 20mm was associated with higher subsidence rates (P = 0.047). Subsidence rates for implant A and B system were 4.27mm (0.12–25.62mm) and 3.43 mm (0.3–11.1 mm) respectively. Significant subsidence was noted in 9.8% (n=8) in implant A and 5.2%(n=2) in implant B. We conclude that immediate postoperative bi-cortical stem contact of <20mm was associated with significantly higher subsidence rates in this study


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 11 - 11
1 May 2018
Metikala S Madan SS Fernandes JA
Full Access

Background. Ilizarov hip reconstruction is a salvage option traditionally done with fixators, which often face limited compliance. We aimed at reviewing our early results of a novel technique with internal devices. Material and Methods. Retrospective evaluation of 7 patients was done that underwent Milch Batchelor procedure with dual plates followed by a second stage femoral lengthening by retrograde magnetic nail. The mean patient age was 13.8 years. A mean valgus of 410 (range, 300 to 550) and extension of 220 (range, 100 to 300) were created proximally. Results. At their mean recent follow-up of 19 months, all extremities were aligned with a mean Pelvic Mechanical Axis Angle (PMAA) of 83.80 and lateral Mechanical Axis Deviation (MAD) of 25.3 mm. The mean Lower-extremity Length Discrepancy (LLD) improved from 3.7 cm (range, 3 to 5 cm) preoperatively to 0.7 cm (range, 0 to 2 cm). The Trendelenburg sign was eliminated in five and delayed in 2. According to a predesigned clinical scoring system, there were 3 (43%) excellent, 2 (28.5%) good, 2 (28.5%) fair, and no poor results. One patient at 9 weeks broke plates, however went for healing. Conclusion. PSHR with internal devices is a patient-friendly alternative to fixators


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 29 - 29
1 May 2018
Wright J Hill RA Eastwood DM Hashemi-Nejad A Calder P Tennant S
Full Access

Purpose. To review the natural history of posteromedial bowing of the tibia and the outcome of limb reconstruction in this condition. Patients and Methods. 38 patients with posteromedial bowing of the tibia presenting between 2000–2016 were identified. Mean follow up from presentation was 78 months. Seventeen patients underwent lengthening and deformity correction surgery, whilst 3 further patients are awaiting lengthening and deformity correction procedures. Results. The greatest correction of deformity occurred in the first year of life, but after the age of 4 years, remodelling was limited. The absolute leg length discrepancy (LLD) increased throughout growth with a mean 14.3% discrepancy in tibial length. In the lengthening group, mean length gained per episode was 45mm (35–60). Mean duration in frame was 192 days, with a healing index of 42.4 days/cm. Significantly higher rates of recurrence in LLD were seen in those undergoing lengthening under the age of 10 years (p=0.046). Four contralateral epiphysiodeses were also performed. Conclusions. Posteromedial bowing of the tibia improves spontaneously during the first years of life, but in 20/38 (53%) patients, limb reconstruction was indicated for significant residual deformity and/or worsening length discrepancy. For larger discrepancies and persistent deformity, limb reconstruction with a hexapod external fixator is an effective technique and should be considered as part of the treatment options. Level of evidence. Level 4 (Case series)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_19 | Pages 5 - 5
1 Nov 2017
Mackenzie S Wallace R White T Murray A Simpson A
Full Access

Kirschner wires are commonly used in paediatric fractures, however, the requirement for removal and the possibility of pin site infection provides opportunity for the development of new techniques that eliminate these drawbacks. Bioabsorbable pins that remain in situ and allow definitive closure of skin at the time of insertion could provide such advantages. Three concurrent studies were performed to assess the viability of bioabsorbable pins across the growth plate. (1) An epidemiological study to identify Kirschner wire infection rates. (2) A mechanical assessment of a bioabsorbable pin compared to Kirschner wires in a simulated supracondylar fracture. (3) The insertion of the implants across the physis of sheep to assess effects of the bioabsorbable implant on the growth plate via macroscopic, pathohistological and micro-CT analysis. An infection rate of 8.4% was found, with a deep infection rate of 0.4%. Mechanically the pins demonstrated comparable resistance to extension forces (p=) but slightly inferior resistance to rotation (p=). The in vivo component showed that at 6 months: there was no leg length discrepancy (p=0.6), with micro-CT evidence of normal physeal growth without tethering, and comparable physeal width (p=0.3). These studies combine to suggest that bioabsorbable pins do not represent a threat to the growth plate and may be considered for physeal fracture fixation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 5 - 5
1 Jun 2017
Reddy G Davies R James L
Full Access

BACKGROUND. Most closed tibial fractures in children can be treated conservatively. On the occasions that surgical intervention is required, there are various options available to stabilise the fracture. We would like to present our experience of using monolateral external fixators in the management of closed tibial fractures. Aim. We sought to assess the time to healing, limb alignment, and complications observed in a cohort of tibial fractures treated with external fixation. METHODS. Our limb reconstruction database was used to identify patients who underwent monolateral external fixation for a closed tibial fracture between January 2008 and December 2016. Radiographs of all patients were assessed to determine the original fracture pattern. Time to union was assessed as the time when the fixator was removed and the patient allowed to mobilise independently without any further support of the limb. The presence or absence of residual deformity was assessed on final follow-up radiographs. RESULTS. 22 patients fulfilled the inclusion criteria. 78% of patients had both tibial and fibular fracture. The mean age at injury was 12 years. The mean time taken for the fracture to heal was 18 weeks. The total duration of follow-up averaged 9 months. The mean Valgus deformity at the final follow up was 4 degrees and the mean Varus deformity was 4 degrees. The mean procurvatum was 4.2 degrees and the mean recurvatum was 6 degrees. 50% of patients had pin site infection. Two patients had tibio fibular synostosis. None of them had leg length discrepancy or refractures. There were no episodes of osteomyelitis. CONCLUSIONS. Five degree of coronal plane deformity and ten degree of sagittal deformity were considered as acceptable in children due to their potential for remodeling. All our patients had acceptable levels of residual deformity. In our opinion monolateral external fixation represents a safe and effective option


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 4 - 4
1 May 2015
Laubscher M Mitchell C Timms A Goodier D Calder P
Full Access

Background:. Leg length discrepancy related to absence of the femoral head with proximal migration of the femur presents a treatment dilemma. Late sequelae of neonatal hip sepsis and chronic hip dislocation due to developmental dysplasia are the most common causes. Traditional teaching dictates that the hip is stabilised prior to limb lengthening. Reconstructive options alter the shape of the proximal femur which complicates future surgery. Methods:. We retrospectively reviewed 3 cases of femoral lengthening with an ‘unstable’ hip without prior stabilization. The aetiology was neonatal hip sepsis in 2 cases and chronic hip dislocation due to developmental dysplasia in 1 case. Lengthening was performed with the use of a retrograde Precice lengthening nail. Results and Discussion:. The desired length (range 5.5 to 6cm) was achieved in all patients without migration of the proximal femur. In all cases patient satisfaction was high with the lengthening and the ability to abort shoe raises. There was an improvement in gait pattern in all patients. Conclusion:. Femoral lengthening is possible without prior stabilisation of the hip in so called ‘unstable’ hip situations. The proximal femoral anatomy is not further altered and future salvage procedures such as a total hip replacement are not compromised


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 2 - 2
1 May 2015
Kendall J Stubbs D McNally M
Full Access

Background:. Closed femoral shortening (CFS) is a recognised procedure for managing leg length discrepancy (LLD). Method:. We report twenty-nine consecutive patients with LLD who underwent CFS using an intramedullary saw and nail. Mean age was 29.2 years (16.1–65.8). The primary outcome was accuracy of correction. Secondary outcomes were complications, union, ASAMI score and re-operation, alongside Patient Reported Outcome Measures (PROMs), using EQ5D-5L and GROC. Results:. Mean pre-operative limb length discrepancy was 3.4 cm (1.5–6.5). Mean planned and achieved shortening was 2.9 cm (1.7–5.0). Mean follow-up was 2.0 years (0.2–8.4). Minimal access surgery was possible in all cases but careful technique is essential. All patients achieved a correction within 5mm of the planned shortening (range 0–5mm). 28 patients (97%) achieved uncomplicated union. One patient had a non-union requiring exchange nailing and subsequent compression plating. 13 patients had nail removal at a mean of 1.7 years and 3 had locking screw removal. Patients had an overall positive experience with 81% reporting high PROM scores. Discussion:. This technique offered accurate limb length correction with few complications. Patients rehabilitated well with good functional outcomes. Conclusion;. CFS with an intramedullary saw is a well-tolerated and effective technique when managing LLD up to 5cm


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 25 - 25
1 May 2015
Aird J Cheesman C Schade A Monsell F
Full Access

Introduction:. Paley et al has developed a multiplier method for calculating both leg length and total height. In the development of this algorithm, they evaluated the effect of factors including bone age and sex. They established that sex had a significant impact, but adjusting for bone age did not improve accuracy. Bone age and menarche have been shown to improve other height prediction models. Purpose:. We used a large prospective cohort to evaluate if the multiplier is independent of physiological age using menarche as a proxy. Methods:. Using the ALSPAC dataset we determined the accuracy of the Paley multiplier for predicting total height and leg length, and assed weather if the date of first menses increased the accuracy of the multiplier. Female patients over the age of 8, with documented final height and final sub-ishial leg length over the age of 15 and a date of first menses were evaluated. Predicted final height was compared with actual final height at all data points. Results:. There were 28332 data points in 3062 girls prior to skeletal maturity in the total height cohort and 8395 data points in 2300 girls in the leg length cohort. When age was corrected using the difference in age at onset of menarche from average, the accuracy of multiplier decreased for both measurements. When a correction of 50% was used, there was an improvement in the accuracy of multiplier predictions, reducing the average error by up to 24%. Conclusions:. Previous studies have failed to demonstrate that the accuracy of the multiplier is improved when adjusted for bone age. We have used the date of first menses as a proxy for bone age and established that making a 50% correction for physiological age improves the accuracy of this method. Significance:. This will potentially allow more accurate prediction of leg length discrepancy, and total height in girls with early menarche


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 28 - 28
1 May 2015
Aird J Cheesman C Schade A Monsell F
Full Access

Background:. Paley et al has developed the multiplier method for predicting leg length. It is a tool that is used clinically to predict leg length discrepancy. The method is also a way of comparing different populations, to identify differences in growth trajectory. This has been done by identifying the differing multipliers for girls and boys. However it has not been used to identify trends in populations separated by time. Tanner showed that in the first half of the twentieth century girls went from an average age of menarche of 15 in 1900, to 13 in 1970, how this has affected growth trajectory over the last 50 years has not been studied. Purpose:. The multiplier method is based on data collected in the 1950's by Anderson and Green, we aim to assess whether there has been a change in growth trajectory between this historical cohort and a contemporary European based cohort. Methods:. The Avon Longitudinal Study of Parents and Children of the 90s (ALSPAC) is a longitudinal cohort study of children recruited antenatally, and followed prospectively. Assessment of sub ischial leg length was made on clinical measurements. There were up to 8 measurements per patient, 2311 girls with a final age at assessment of greater than 15 years and 123 males with a final age of assessment of greater than 16 years were assessed. We used the multiplier method to assess the predicted final leg length and compared this with the actual leg length. Result:. There was no difference between the multiplier in girls, in the contemporary cohort and the historical cohort. The average age of menarche in the contemporary group was 12.7. In boys the data is limited, due to later growth and it is not possible to draw comparisons from this group. Conclusion:. This data provides good evidence that there has not been a significant change in growth trajectory in girls over the last 50 years. Significance:. Implications on the confidence with which we can use the multiplier method in this population


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 9 - 9
1 Feb 2014
Halai M Gupta S Gilmour A Bharadwaj R Khan A Holt G
Full Access

Leg length discrepancy (LLD) can adversely affect functional outcome and patient satisfaction after total hip arthroplasty. We describe a novel intraoperative technique for femoral component insertion. We aimed to determine if this technique resulted in the desired femoral placement, as templated, and if this was associated with a reduced LLD. A series of fifty consecutive primary total hip replacements were studied. Preoperative digital templating was performed on standardised PA radiographs of the hips by the senior surgeon. The preoperative LLD was calculated and the distance from the superior tip of the greater trochanter to the predicted shoulder of the stem was calculated (GT-S). Intraoperatively, this length was marked on the rasp handle and the stem inserted to the predetermined level by the surgeon. This level corresponded to the tip of the greater trochanter and formed a continuous line to the mark on the rasp handle. Three independent blinded observers measured the GT-S on the postoperative radiographs. We assessed the relationship between the senior author's GT-S (preoperative) and the observers' GT-S (postoperative) using a Person correlation. The observers also measured the preoperative and postoperative LLD, and the inter-observer variability was calculated as the intra-class correlation coefficient. There was a strong correlation of preoperative and postoperative GT-S (R=0.87), suggesting that the stem was inserted as planned. The mean preoperative and postoperative LLD were −4.3 mm (−21.4–4) and −0.9 mm (−9.8–8.6), respectively (p<0.001). This technique consistently minimised LLD in this series. This technique is quick, non-invasive and does not require supplementary equipment


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 63 - 63
1 Apr 2013
Kim J Oh C Oh JK Lee HJ
Full Access

Background. Although gradual bone transport may provide a large-diameter bone, complications are common with the long duration of external fixation. To reduce such complications, a new technique of bone transport with a locking plate has been done for tibial bone defect. Methods. In 13 patients (mean age, 38.9 years) of chronic osteomyelitis or traumatic bone defect, segmental transport was done using external fixator with a locking plate. In surgical technique, a locking plate was fixed submuscularly, holding the proximal and distal segments. Then, the external fixator for transport was fixed without contact of the locking plate. After docking, 2 or 3 screws were fixed at the transported segment through the plate holes. At the same time, the external fixator was removed. Results. The mean transported amount was 5.8cm, and the mean external fixation index was 13.3 days/cm. The primary union at the docking site was achieved in all cases. No patients showed angular deformity over 5 degrees. There were 2 patients of leg length discrepancy with less than 1.5cm. Deep infection or recurrence of osteomyelitis was not developed. Except for two patients with pre-existed peroneal nerve injury, all had excellent or good functions according to the criteria of Mekhail. Conclusion. In tibial reconstruction, transport with a locking plate may be a successful method with reducing external fixation time. It may allow patients to return to daily life earlier with relatively few complications


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 3 - 3
1 May 2013
Baliga S Maheshwari R Dougall T Barker S Elliott K
Full Access

The 8-plate (Orthofix, SRL, Italy) is a titanium extraperiosteal plate with 2 screws which acts as a hinge at the outer limits of the physis. It has been used for correction of both angular and sagittal deformity around the knee. To our knowledge this is the first study describing the use of 8-plates in leg length discrepancy (LLD) correction. We aimed to evaluate outcomes of temporary 8-plate epiphysiodesis in LLD, and to assess the complications associated with its usage. This retrospective study included 30 patients between 2007 and 2010 whom underwent 8-plate epiphysiodesis to address LLD. Leg length measurements were recorded using erect full leg length scanograms and comparison made between pre-operative, interval and final scanograms. Any deviations of the mechanical axis were also recorded. During the study period 34 epiphysiodeses were performed on 30 patients. There were 17 males and 14 females. The average age at the time of procedure was 10.7 years (range 3–15). Average time to final follow-up was 24 months (range 52–10). The average pre-operative LLD was 2.5 cm (range 1.5–6 cm). The mean overall rate of correction was 1.0 cm per year. The mean residual LLD at end of treatment was 1.1 cm (range 0–4.5 cm). Two patients experienced genu recurvatum deformity. This was associated with placement of distal femoral plates anterior to the mid-lateral line. Based on our experience 8-plate epiphysiodesis is a reversible, minimally invasive procedure with reliable results in length correction. However, careful device placement is required to prevent deformity


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 350 - 350
1 Sep 2012
Aksahin E Guzel A Yuksel H Celebi L Erdogan A Aktekin C Bicimoglu A
Full Access

Aim. The purpose of this study was to analyze the patellofemoral kinematics in neglected adult developmental dysplasia of the hip patients with patellofemoral symptoms and tried to clarify the affect of the severity of dislocation, the amount of limb length discrepancy, the deviation of mechanical axis and the changes in femoral anteversion on patellofemoral alignment. Methods. The dynamic patellofemoral CT results of 39 patients with DDH suffering from knee pain were reviewed. The mean age was 40.07 (range: 22–61). 14 of them were bilateral and 25 were unilateral neglected DDH patients. The CT results of 12 patients suffering from unilateral patellofemoral pain following the treatment of locked intramedullary nailing was taken as control group. In this patients atraumatic and asymptomatic normal site was taken as control group. Results. In unilateral neglected DDH patients there was significantly higher medial patellar displacement in 0, 15, 30, 60 degrees flexion in the knee at the site of dislocation. Again in uninvolved site medial patellar displacement in 15, 30, 60 degrees flexion was higher with respect to control group. In the involved extremity the PTA angle in 0, 15, 30, 60 degrees flexion were significantly higher than in control group. This increase in PTA angle corresponding to medial patellar tilt was observed only in involved extremity. In the knees of patients with bilateral DDH there was significant medial patellar displacement in every flexion degrees with respect to control group. Besides in bilateral DDH patients, the PTA angle in 15, 30, 60 degrees flexion were significantly higher than control group corresponding to medial patellar tilt. The amount of leg length discrepancy and the severity of dislocation as well as mechanical axis deviation were not affecting the patellofemoral parameters in both unilateral and bilateral DDH patients. Conclusion. Both in unilateral and bilateral DDH patients there are major changes in patellar tracking on femur during knee flexion. Increased medial shift and medial patellar tilt were seen in these patient groups. The neglected DDH patients suffering from knee pain should be analyzed not only for tibiofemoral abnormalities but also for patellofemoral malignment


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 128 - 133
1 Jan 2017
Socci AR Casemyr NE Leslie MP Baumgaertner MR

Aims

The aim of this paper is to review the evidence relating to the anatomy of the proximal femur, the geometry of the fracture and the characteristics of implants and methods of fixation of intertrochanteric fractures of the hip.

Materials and Methods

Relevant papers were identified from appropriate clinical databases and a narrative review was undertaken.