Risk of revision following total knee replacement is relatively high in patients under 55 years of age, but little is reported regarding non-revision outcomes. This study aims to identify predictors of dissatisfaction following TKR in patients younger than 55 years of age. We assessed 177 TKRs (157 consecutive patients) from 2008 to 2013. Data was collected on age, sex, implant, indication, BMI, social deprivation, range of motion, and prior
This paper describes an audit loop. We studied patients undergoing hip and
Background. Improving positioning and alignment by the use of computer assisted surgery (CAS) might improve longevity and function in total knee replacements. This study evaluates the short term results of computer navigated knee replacements based on data from a national register. Patients and Methods. Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The five most common implants and the three most common navigation systems were selected. Cemented, uncemented and hybrid knees were included. With the risk for revision due to any cause as the primary end-point, 1465 computer navigated knee replacements (CAS) were evaluated against 8214 conventionally operated knee replacements (CON). Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous
Introduction. Malrotation following total knee replacement is directly related to poor outcome. The knowledge of proximal and distal rotational axes and angles of the femur is therefore of high importance. The aim of the study was to determine whether the most used proximal and distal femoral angles; femoral anteversion angle (FAA) and posterior condylar angle (PCA) were different within individuals, between right, left and gender. As well, we studied whether the “inferior condylar angle” is correlated to the PCA and therefore useful in determining the rotation of the distal femur. Material and Methods. From 36 cadavers the femora were obtained and after removing the soft tissue a Computed Tomography (CT) scan was made. Three angles were measured: (i) the FAA between femoral columnar line (FHNL) and posterior condylar line (PCL), (ii) the PCA between anatomical transepicondylar line (TEL) and PCL, (iii) the inferior condylar angle (ICA) between the TEL and inferior condylar line (ICL). Statistical analysis of comparative relationships between the different angles was examined by calculating correlation coefficients and a paired t-test. Results. The mean FAA, PCA and ICA for the whole group were respectively 12.0 degrees (range 0.2–31.6, SD 8.3, 95% CI 9.6–14.4), 4.8 degrees (range 0.9–9.6, SD 2.3, 95% CI 4.1–5.4) and 4.5 degrees (range 0.1–9.8, SD 2.1, 95% CI 3.9–5.1). A strong correlation of the FAA was found within the total group and left versus right (r = 0.82; p = 0.00). A weaker relationship was found for the total group of the PCA measurements (r = 0.59; p = 0.00). When FAA compared to the PCA subdivided in only sexes, there is a weak correlation for the female group (r = 0.54; p = 0.00) Despite the small mean difference of the mean ICA and PCA, there was no correlation between these two angles. Conclusion. Considering the weak correlation of the FAA and PCA within the group but also individuals, the importance of development of more individual approaches for determining the optimal rotation of the components in total
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
We investigated whether patients who underwent internal fixation for an isolated acetabular fracture were able to return to their previous sporting activities. We studied 52 consecutive patients with an isolated acetabular fracture who were operated on between January 2001 and December 2002. Their demographic details, fracture type, rehabilitation regime, outcome and complications were documented prospectively as was their level and frequency of participation in sport both before and after surgery. Quality of life was measured using the EuroQol-5D health outcome tool (EQ-5D). There was a significant reduction in level of activity, frequency of participation in sport (both p <
0.001) and EQ-5D scores in patients of all age groups compared to a normal English population (p = 0.001). A total of 22 (42%) were able to return to their previous level of activities: 35 (67%) were able to take part in sport at some level. Of all the parameters analysed, the Matta radiological follow-up criteria were the single best predictor for resumption of sporting activity and frequency of participation.
Intramedullary tibial nailing was performed in ten paired cadavers and the insertion of a medial-to-lateral proximal oblique locking screw was simulated in each specimen. Anatomical dissection was undertaken to determine the relationship of the common peroneal nerve to the cross-screw. The common peroneal nerve was contacted directly in four tibiae and the cross-screw was a mean of 2.6 mm (1.0 to 10.7) away from the nerve in the remaining 16. Iatrogenic injury to the common peroneal nerve by medial-to-lateral proximal oblique locking screws is therefore a significant risk during tibial nailing.