Throughout the 20th Century, it has been postulated that the knee moves on the basis of a four-bar link mechanism composed of the cruciate ligaments, the femur and the tibia. As a consequence, the femur has been thought to roll back with flexion, and total knee arthroplasty (TKA) prostheses have been designed on this basis. Recent work, however, has proposed that at a position of between 0° and 120° the medial femoral condyle does not move anteroposteriorly whereas the lateral femoral condyle tends, but is not obliged, to roll back – a combination of movements which equates to tibial internal/ femoral external rotation with flexion. The aim of this paper was to assess if the articular geometry of the GMK Sphere TKA could recreate the natural knee movements The pattern of knee movement was studied in 15 patients (six male: nine female; one male with bilateral TKAs) with 16 GMK Sphere implants, at a mean age of 66 years (53 to 76) with a mean BMI of 30 kg/m2 (20 to 35). The motions of all 16 knees were observed using pulsed fluoroscopy during a number of weight-bearing and non-weight-bearing static and dynamic activities.Objectives
Methods
Introduction. Currently, knee and hip implants are evaluated experimentally using mechanical simulators or clinically using long-term follow-up. Unfortunately, it is not practical to mechanically evaluate all patient and surgical variables and predict the viability of implant success and/or performance. More recently, a validated mathematical model has been developed that can theoretically simulate new implant designs under in vivo conditions to predict joint forces kinematics and performance. Therefore, the objective of this study was to use a validated forward solution model (FSM) to evaluate new and existing implant designs, predicting mechanics of the hip and knee joints. Methods. The model simulates the four quadriceps muscles, the complete hamstring muscle group, all three gluteus muscles, iliopsoas group, tensor fasciae latae, and an adductor muscle group. Other soft tissues include the patellar ligament, MCL, LCL, PCL, ACL, multiple ligaments connecting the patella to the femur, and the primary hip capsular ligaments (ischiofemoral, iliofemoral, and pubofemoral). The model was previously validated using telemetric implants and fluoroscopic results and is now being used to analyze multiple implant geometries. Virtual implantation allows for various surgical alignments to determine the effect of surgical errors. Furthermore, the model can simulate resecting, weakening, or tightening of soft tissues based on surgical errors or technique modifications. Results. The model revealed PCL weakening leads to paradoxical anterior slide of both femoral condyles. This paradoxical slide reduces maximum flexion and increases knee forces as seen in TKA fluoroscopic studies. Cam/post kinematics in posterior-stabilized designs were also analyzed, revealing cam/post forces increasing linearly with flexion. While cam/post engagement should ideally occur superiorly on the post and move inferiorly throughout
Backgrounds. Most of in vivo kinematic studies of total knee arthroplasty (TKA) have reported on varus knee. TKA for the valgus knee deformity is a surgical challenge. The purposes of the current study are to analyze the in vivo kinematic motion and to compare kinematic patterns between weight-bearing (WB) and non-weight-bearing (NWB) knee flexion in posterior-stabilized (PS) fixed-bearing TKA with pre-operative valgus deformity. Methods. A total of sixteen valgus knees in 12 cases that underwent TKA with Scorpio NRG PS knee prosthesis operated by modified gap balancing technique were evaluated. The mean preoperative femorotibial angle (FTA) was 156°±4.2°. During the surgery, distal femur and proximal tibia was cut perpendicular to the mechanical axis of each bone. After excision of the menisci and cruciate ligaments, balancer (Stryker joint dependent kinematics balancer) was inserted into the gap between both bones for evaluation of extension gap. Lateral release was performed in extension. Iliotibial bundle (ITB) was released from Gerdy tubercle then posterolateral capsule was released at the level of the proximal tibial cut surface. If still unbalanced, pie-crust ITB from inside-out was added at 1 cm above joint line until an even lateral and medial gap had been achieved. Flexion gap balance was obtained predominantly by the bone cut of the posterior femoral condyle. Good postoperative stability in extension and flexion was confirmed by stress roentgenogram and axial radiography of the distal femur. We evaluated the in vivo kinematics of the
Many nonoperative techniques exist to alleviate pain in unicompartmental osteoarthritic knees including physical therapy, heel wedges and off-loading knee braces [. 1. ]. Arthritic knee braces are particularly effective since they can be used on a regular basis at home, work, etc. Previous knee brace studies focused on their ability to stabilize anterior cruciate ligament (ACL) deficient knees. A standard technique for analyzing brace effectiveness is the use of an athrometer to look at the range-of-motion. Although this is helpful, it is more useful to use X-ray or fluoroscopy techniques to analyze the in vivo 3-D conditions of the femur and tibia. One method for doing this is Roentgen Steroephotogrammetric Analysis, which uses a calibration object and two static X-rays to perform 3-D registration of the femur and tibia. This technique is limited to static and typically non-weight bearing analysis. We have analyzed five patients with moderate to severe osteoarthritis in both step up and step down activities with two different knee braces and also without a
Outcome measures must be valid, reliable and responsive to change criteria. The most common clinical outcome measures are Knee Society Scores, SF-36 quality of life scores, HAQ and DAS scores. However, performance based measures of functioning may not be dependent on patient report or observer judgment. Examples of objective pre- and post-operative performance outcome measures are surface Electromyography (EMG) of muscles, kinematics and kinetics (gait analysis). For the evaluation of implant survival after joint arthroplasty, Roentgen Stereophotogrammetric Analysis (RSA) is the golden standard to assess micro-motion of the implants. Surface EMG can be used to asses the stability of joints before and after intervention. Calibrating of raw EMG data is necessary to compare the data between subjects. It was shown that calibration of EMG data by means of isokinetic contractions on a dynamometer during flexion and extension was more reliable and repeatable than using a Maximum Voluntary Contraction in patients after total knee arthroplasty. After total knee arthroplasty RA patients have a lower net knee joint moment and a higher co-contraction than controls, indicating avoidance of net joint load and an active stabilization of the