Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 89 - 89
1 Jan 2016
Nishio Y Onodera T Kasahara Y Seito N Takahashi D Kondo E Iwasaki N Majima T
Full Access

Introduction. Total knee arthroplasty (TKA) is a well-established procedure associated with excellent clinical results. We have previously reported that intraoperative knee kinematics correlate with the clinical outcome in mobile bearing TKA. In addition, the intraoperative knee kinematics pattern does not correlate with the degree of preoperative knee deformity in mobile bearing TKA. However, the relationship among preoperative knee deformity, intraoperative kinematics and clinical outcome in fixed bearing TKA has been unknown. The purpose of this study is to compare the relationship among preoperative knee deformity, knee kinematics after fixed bearing TKA and the clinical outcome including the subjective outcomes evaluated by the new knee society score (KSS). Materials and Methods. A cross-sectional survey of thirty-five consecutive medial osteoarthritis patients who had a primary TKA using a CT-based navigation system was conducted. All knees had a Kellgren-Lawrence grade of 4 in the medial compartment and underwent a primary posterior stabilized TKA (Genesis II, Smith&Nephew) between May 2010 and October 2012. In all cases, a computed tomography-guided navigation system (Brain LAB, Heimstetten, Germany) was used. All surgery was performed by the subvastus approach and modified gap technique. Intraoperative knee kinematics was measured using the navigation system after implantation and closure of the retinaculum and soft tissue except for the skin. Subjects were divided into two groups based on intraoperative kinematic patterns: a medial pivot group (M group, n=19)(Figure 1) and a non-medial pivot group (N group, n=16)(Figure 2). Subjective outcomes with the new KSS and clinical outcomes were evaluated. Statistical analysis to compare the two groups was made using unpaired a Student t test. Result. Regarding the postoperative clinical result (knee flexion angle, knee extension angle, mechanical FTA,% mechanical axis), there were no significant differences between the two groups. Although there were also no significant differences in KSS evaluation between the two groups, there was a tendency for M group to be superior to N group in current knee symptom (M group: 17.3±5.6, N group: 12.9±8.2, p = 0.07) and functional activities (M group: 55.1±21.5, N group: 42.7±22.6, p = 0.10). Regarding preoperative examination, varus knee deformity (mechanical FTA and% mechanical axis) in N group was significantly more severe than that of M group (p=0.04, p=0.04, respectively). Discussion. Over half of patients (54%) could achieve medial pivot kinematics in fixed bearing TKA with the possibility to improve a subjective clinical result. Although we previously could not detect any relationship between preoperative varus knee deformity and intraoperative kinematics in mobile bearing TKA, the preoperative varus knee deformity in the non-medial pivot group was significantly severer than that of the medial pivot group in fixed type TKA. Our results indicate that if a TKA is done to a severe varus knee deformity the postoperative knee kinematics tend to result in a non-medial pivot pattern. In conclusion, because it tends to result in a non-medial pivot pattern, extra care needs to be taken to avoid postoperative abnormal knee kinematics in the performance of a fixed type TKA to a severe varus knee deformity


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 30 - 39
1 Oct 2015
Baldini A Castellani L Traverso F Balatri A Balato G Franceschini V

Primary total knee arthroplasty (TKA) is a reliable procedure with reproducible long-term results. Nevertheless, there are conditions related to the type of patient or local conditions of the knee that can make it a difficult procedure. The most common scenarios that make it difficult are discussed in this review. These include patients with many previous operations and incisions, and those with severe coronal deformities, genu recurvatum, a stiff knee, extra-articular deformities and those who have previously undergone osteotomy around the knee and those with chronic dislocation of the patella. Each condition is analysed according to the characteristics of the patient, the pre-operative planning and the reported outcomes. . When approaching the difficult primary TKA surgeons should use a systematic approach, which begins with the review of the existing literature for each specific clinical situation. Cite this article: Bone Joint J 2015;97-B(10 Suppl A):30–9


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 595 - 595
1 Oct 2010
Joshi Y Bass A Peter V
Full Access

Purpose: The aim of this study was to see if there is any relationship between a positive hamstring shift test, which is a measure of knee flexion deformity after eliminating pelvic tilt with anterior pelvic tilt during the gait cycle. Methods: We included all patients with cerebral palsy who had a gait analysis and a full physical assessment including measurement of the popliteal angle and hamstring shift test between August and December 05. The difference in measurement of knee flexion between the popliteal angle at 90 degrees and the hamstring shift test was termed hamstring length (HL). There were 33 patients of which 9 [18 limbs] were selected who fulfilled the criteria of a significant positive hamstring shift [> 10 degrees difference]. Maximum dynamic hip extension and average pelvic tilt were estimated from the gait analysis graph. SPSS13.0 was used to analyse the data. Results: Mean HL was found to be 15.28 degrees. 6 (33.3%) patients had average pelvic tilt < 5 degrees, 8 (44.4%) was between 5–10 degrees and 4 (22.2%) patients had pelvic tilt of more than 10 degrees. The data had a normal distribution. There was no co relation between HL and pelvis tilt [p value:0.363 and r= −0.228.] or between average anterior pelvic tilt and the hip fixed flexion deformity. (p=0.361). However, it was found that maximum dynamic hip extension had strong negative association with average pelvic tilt (p=0.05, r = −0.455). Conclusion: This study suggests that hamstring shift test does not have any correlation with pelvic tilt. In patients with a positive hamstring shift test, correcting the pelvic tilt will not correct the flexion deformities of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 471 - 473
1 May 1994
Aspden R Porter R

We report the case of a child with cerebral palsy and spastic diplegia treated for bilateral fixed flexion of the knee by bilateral hamstring lengthening. An attempt to straighten the legs from 90 degrees to 20 degrees flexion damaged the sciatic nerve. There are no objective means of estimating how much deformity can be reduced safely. We present a method of calculating the extra strain in the sciatic nerve produced by reducing a flexion deformity. The result, combined with clinical judgement, provides guidelines for safe corrective surgery.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 42 - 45
1 Dec 2023

The December 2023 Children’s orthopaedics Roundup. 360. looks at: A comprehensive nonoperative treatment protocol for developmental dysplasia of the hip in infants; How common are refractures in childhood?; Femoral nailing for paediatric femoral shaft fracture in children aged eight to ten years; Who benefits from allowing the physis to grow in slipped capital femoral epiphysis?; Paediatric patients with an extremity bone tumour: a secondary analysis of the PARITY trial data; Split tibial tendon transfers in cerebral palsy equinovarus foot deformities; Liposomal bupivacaine nerve block: an answer to opioid use?; Correction with distal femoral transphyseal screws in hemiepiphysiodesis for coronal-plane knee deformity


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 19 - 19
19 Aug 2024
Macheras G Kostakos T Tzefronis D
Full Access

Total hip arthroplasty (THA) for congenital hip dysplasia (CDH) presents a challenge. In high-grade CDH, key surgical targets include cup placement in the anatomical position and leg length equality. Lengthening of more than 4 cm is associated with sciatic nerve injury, therefore shortening osteotomies are necessary. We present our experience of different shortening osteotomies including advantages and disadvantages of each technique. 89 hips, in 61 pts (28 bilateral cases), for high CDH were performed by a single surgeon from 1997 to 2022. 67 patients were female and 22 were male. Age ranged from 38 to 68 yrs. In all patients 5–8cm of leg length discrepancy (LLD) was present, requiring shortening femoral osteotomy. 12 patients underwent sequential proximal femoral resection with trochanteric osteotomy, 46 subtrochanteric, 6 midshaft, and 25 distal femoral osteotomies with simultaneous valgus correction were performed. All acetabular prostheses were placed in the true anatomical position. We used uncemented high porosity cups. Patients were followed up for a minimum of 12 months. All osteotomies healed uneventfully except 3 non-unions of the greater trochanter in the proximal femur resection group. No femoral shaft fractures in proximally based osteotomies. No significant LLD compared to the unaffected or reconstructed side. 2 patients suffered 3 and 5 degrees malrotation of the femur in the oblique sub-trochanteric group. 3 patients suffered transient sciatic nerve palsies. Shortening femoral osteotomies in the treatment of DDH are necessary to avoid injury to the sciatic nerve. In our series, we found transverse subtrochanteric osteotomies to be the most technically efficient, versatile and predictable in their clinical outcome, due to the ability to correct rotation and preserve the metaphyseal bone integrity, allowing for better initial stem stability. Distal femoral osteotomies allowed for controllable correction of valgus knee deformity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 12 - 12
17 Apr 2023
Van Oevelen A Burssens A Krähenbühl N Barg A Audenaert E Hintermann B Victor J
Full Access

Several emerging reports suggest an important involvement of the hindfoot alignment in the outcome of knee osteotomy. At present, studies lack a comprehensive overview. Therefore, we aimed to systematically review all biomechanical and clinical studies investigating the role of the hindfoot alignment in the setting of osteotomies around the knee. A systematic literature search was conducted on multiple databases combining “knee osteotomy” and “hindfoot/ankle alignment” search terms. Articles were screened and included according to the PRISMA guidelines. A quality assessment was conducted using the Quality Appraisal for Cadaveric Studies (QUACS) - and modified methodologic index for non-randomized studies (MINORS) scales. Three cadaveric, fourteen retrospective cohort and two case-control studies were eligible for review. Biomechanical hindfoot characteristics were positively affected (n=4), except in rigid subtalar joint (n=1) or talar tilt (n=1) deformity. Patient symptoms and/or radiographic alignment at the level of the hindfoot did also improve after knee osteotomy (n=13), except in case of a small pre-operative lateral distal tibia- and hip knee ankle (HKA) angulation or in case of a large HKA correction (>14.5°). Additionally, a pre-existent hindfoot deformity (>15.9°) was associated with undercorrection of lower limb alignment following knee osteotomy. The mean QUACS score was 61.3% (range: 46–69%) and mean MINORS score was 9.2 out of 16 (range 6–12) for non-comparative and 16.5 out of 24 (range 15–18) for comparative studies. Osteotomies performed to correct knee deformity have also an impact on biomechanical and clinical outcomes of the hindfoot. In general, these are reported to be beneficial, but several parameters were identified that are associated with newly onset – or deterioration of hindfoot symptoms following knee osteotomy. Further prospective studies are warranted to assess how diagnostic and therapeutic algorithms based on the identified criteria could be implemented to optimize the overall outcome of knee osteotomy. Remark: Aline Van Oevelen and Arne Burssens contributed equally to this work


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 26 - 26
1 Apr 2022
Parnami V Shah V Ranmuthuge S Giles S Fernandes J
Full Access

Introduction. To evaluate the results of correction of knee deformities based on deformity analysis in Achondroplasia, the commonest skeletal dysplasia as some have concomitant ligamentous deformities. Materials and Methods. Retrospective study from a prospective database (2007–2020) of achondroplasts who underwent growth modulation. Analysis of medical records with objective measurement of mechanical axis radiographs was done (Traumacad). Satisfactory alignment was defined as neutral to slightly varus (0–15 mm MAD) so that the MCL/LCL laxity is not revealed. Results. 23 patients, 41 limbs, 34 bilateral, 6 unilateral underwent multiple growth modulation procedures. 2 had valgus knees. 15 patients underwent proximal fibular epiphysiodesis in addition for LCL laxity with one isolated fibular epiphysiodesis. Mechanical axis deviation (MAD) improved or normalised in 16 patients (70%). 4 patients were still undergoing correction. 4 patients needed further surgery out of which 2 patients were over 13 years when growth modulation was attempted and 2 needed correction of ankle varus. JLCA improved/ normalised in 12 patients (75%) with evidence of indirect LCL tightening and no improvement was seen in 4. The rate of correction was MAD 0.61mm/month, LDFA 0.29°/month and MPTA 0.13°/month; expectedly lower in achondroplasia due to lower growth velocity. Conclusions. This study highlights the pathology, application of growth modulation as per deformity analysis unlike previous studies. Proximal fibular epiphysiodesis improves LCL laxity in a majority of these children and is a simple procedure compared to our published series with indirect LCL tightening with frames


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 27 - 27
23 Feb 2023
Hassanein M Hassanein A Hassanein M Khaled M Oyoun NA
Full Access

This study was performed at Assiut University, Assiut, Egypt. Anterior distal femoral hemiepiphysiodesis (ADFH) using intra-articular plates for the correction of paediatric fixed knee flexion deformities (FKFD) has two main documented complications: postoperative knee pain and implant loosening. This study describes a biomechanical analysis and a preliminary report of a novel extra-articular technique for ADFH. Sixteen femoral sawbones were osteotomized at the level of the distal femoral physis and fixed by rail frames to allow linear distraction simulating longitudinal growth. Each sawbone was tested twice: first using the conventional technique with medial and lateral parapatellar eight plates (group A) and then with the plates inserted in the proposed novel location at the most anterior part of the medial and lateral surfaces of the femoral condyles with screws in the coronal plane (group B). Gradual distraction was performed, and the resulting angular correction was measured. Strain gauges were attached to the plates, and the amount of strain (and equivalent stress) over the plates was recorded. This technique was then applied to 9 paediatric FKFDs of different aetiologies. The preoperative FKFD and the amount of subsequent angular correction were measured. The amount of angular correction was higher in group B at 5, 10-, and 15-mm of distraction (p<0.001). The maximum and overall stresses measured throughout the distraction process were higher in group A (p<0.001). The mean FKFD improved from 24 ± 9° preoperatively to 9 ± 7° after 10 ± 3° months (p<0.001). The correction rate was 1.81 ± 0.65° per month. During ADFH, the fixation of the eight plates in the coronal plane at the anterior part of the femoral condyles may produce greater correction and lower stresses over the implants as compared to the conventional technique. Preliminary results from our initial series seem to support the effectiveness of this technique with respect to the degree of angular correction achieved


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 16 - 16
1 Feb 2020
Dagneaux L Karl G Michel E Canovas F Rivière C
Full Access

Introduction. The constitutional knee anatomy in the coronal plane includes the distal femoral joint line obliquity (DFJLO) which in most patients is in slight valgus positioning. Despite this native anatomy, the mechanical positioning of the femoral component during primary total knee arthroplasty (TKA) often ignores the native DFJLO opting to place the femur in a set degree of valgus that varies upon the practitioner's practice and experience. Unfortunately, this technique is likely to generate high rate of distal lateral femoral overstuffing. This anatomical mismatch might be a cause of anterior knee pain and therefore partly explain the adverse functional outcomes of mechanically aligned (MA) TKA. Our study aims at assessing the relationship between constitutional knee anatomy and clinical outcomes of MA TKA. We hypothesized that a negative relationship would be found between the constitutional frontal knee deformity, the distal femoral joint line obliquity, and functional outcomes of MA TKA with a special emphasize on patellofemoral (PF) specific outcomes. Methods. One hundred and thirteen patients underwent MA TKA (posterior-stabilized design) for primary end-stage knee osteoarthritis. They were prospectively followed for one year using the New KSS 2011 and HSS Patella score. Residual anterior knee pain was also assessed. Knee phenotypes using anatomical parameters (such as HKA, HKS, DFJLO and LDFA (Lateral distal femoral angle)) were measured from preoperative and postoperative lower-limb EOS® images (Biospace, Paris, France). We assessed the relationship between the knee anatomical parameters and the functional outcome scores at 1 year postoperatively. Results. We investigated four groups according to the preoperative obliquity of the distal femur and HKA. The group with high DFJLO and varus knee deformity demonstrated lower HSS scores (drop>10%, p=0.03) and higher rate of anterior knee pain (p=0.03). Higher postoperative variation of LDFA was associated with lower HSS scores (r = −0.2367, p=0.03) and with higher preoperative DFJLO (p=0.0001) due to the MA technique. Knee phenotypes with LDFA<87° presented higher risk of variation of LDFA. No correlation was found using New KSS 2011 outcomes at one-year follow-up. Discussion/Conclusion. Disregard of the constitutional knee anatomy (LDFA and DFJLO) when performing a MA TKA may generate a non-physiologic knee kinematics that impact patellofemoral outcomes and resulting in residual anterior knee pain. While these results are restricted to modern posterior-stabilized TKA design, recent in silico and in vitro studies supported the negative effect of the lateral overstuffing of the femoral component in the coronal plane during knee flexion. This study provides further evidence that suggest patient-specific anatomical considerations are needed to optimize component position and subsequent outcomes following primary TKA. Additional studies are needed to integrate the rotational status of the femoral component in this analysis. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 108 - 108
1 Feb 2020
Aggarwal A Sharif D Prakash M Saini U
Full Access

Introduction. Patients undergoing total knee arthroplasty (TKA) with end-stage osteoarthritis of knee have secondary foot and ankle pathology. Some compensatory changes occur at ankle and subtalar joint secondary to malalignment and deformity at the knee joint. Purpose was to evaluate the changes in hindfoot malalignment and foot deformities in patients with advanced osteoarthritis of knee requiring TKA and effect of correction of knee deformities post TKA on foot/Ankle alignment. Methods. 61 consecutive patients with Kellgren-Lawrence grade IV osteoarthritis knee undergoing TKA were enrolled in a prospective blinded study. Demographic data, deformities at knee and ankle, hindfoot malalignment and functional outcome scores such as VAS, KSS, WOMAC scores, Foot and Ankle Disability Index (FADI) and Foot posture index (FPI) were recorded preoperatively and postoperatively at 6, 12 weeks and final follow up (range: 6–21 months; mean: 14.2months). Results. Statistically significant improvement was observed in KSS score, WOMAC score, FADI and FPI after TKA. There was improvement in ankle valgus after correction of knee varus deformity. Hind foot changes mainly occured at subtalar joint. Hallux valgus (10 patients), and Pesplanus (5 patients) were associated with advanced osteoarthritis of knee. Gait profile score and Gait deviation index improved significantly after TKA. There was increased stance phase and decreased stride length in knee osteoarthritis patients which improved after TKA. Conclusion. Hind foot malalignment with foot deformities (hind foot valgus) occur secondary to knee malalignment and deformities (varus deformity) in advanced osteoarthritis of knee which subsequently improve following TKA


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 57 - 57
1 Dec 2020
Ateş YB Çullu E Çobanoğlu M
Full Access

Aim. To investigate the effect of the eight plate position in sagittal plane on tibial slope in temporary epiphysiodesis technique applied to the proximal tibia and whether there is a rebound effect after removing the plate. Method. Forty New Zealand rabbits (6 weeks old) were divided into four groups. In all groups, two 1.3 mm mini plates and cortical screws implantation were placed on both medial and lateral side of the proximal epiphysis of the right tibia. In Group 1 and 3, the plates were placed on anterior of the proximal tibial anatomical axis in the sagittal plane, and placed posteriorly in Group 2 and 4. The left tibia was examined as control in all groups. Group 1 and Group 2 were sacrificed after four week-follow-up. In Group 3 and Group 4, the implants were removed four weeks after index surgery and the rabbits were followed four more weeks to investigate the rebound effect. The tibial slope was measured on lateral X-rays every two weeks. Both medial and lateral plateau slopes were evaluated on photos of the dissected tibia. Results. In Group 1, right MTPA (medial tibial plateau angle) and left MTPA, right LTPA (lateral tibial plateau angle) and left LTPA, and right 4wTPPA (the tibial proximal posterior angle at 4th week) and left 4wTPPA values were compared with each other. There was a significant difference in MTPA, LTPA, and 4wTPPA in Group 1 (p: 0.003, 0.006, 0.004). In Group 1, the medial and lateral slope significantly decreased after 4 weeks. There was no significant difference in MTPA, LTP and 4wTPPA measurements in Group 2 (p= 0.719, 0.306, 0.446, respectively). In Group 2, the slope did not change in four weeks. There was a significant difference in MTPA, LTPA, 4wTPPA, and 8wTPPA (tibial proximal posterior angle at 8th week) in Group 3 (p= 0.005, 0.002, <0.001, <0.001, respectively). In Group 3, the slope decreased at 4th week and remained stabile during the next four week-follow up and no rebound effect was observed. There was no significant difference in MTPA, LTPA, 4wTPPA, and 8wTPPA measurements in Group 4 (p= 0.791, 0.116, 0.232, 0.924), respectively. In group 4, slope did not change at 4th week of index surgery and no rebound effect was observed in the next four week-follow up. Conclusion. If eight plates were placed on anterior of lateral proximal tibia axis on both medial and lateral side, the tibial slope would reduce, and remain stabile after implant removal. Care should be taken to place the plates on the line of proximal tibial axis in sagittal plane in temporary epiphysiodesis technique performed due to angular knee deformities. Changing the slope due to plate placement can be used as a secondary gain for patients who will benefit from slope change, such as adolescent ACL surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 79 - 79
1 Jul 2020
Legault J Beveridge T Johnson M Howard J MacDonald S Lanting B
Full Access

With the success of the medial parapatellar approach (MPA) to total knee arthroplasty (TKA), current research is aimed at reducing iatrogenic microneurovascular and soft tissues damage to the knee. In an effort to avoid disruption to the medial structures of the knee, we propose a novel quadriceps-sparing, subvastus lateralis approach (SLA) to TKA. The aim of the present study is to compare if a SLA can provide adequate exposure of the internal compartment of the knee while reducing soft tissue damage, compared to the MPA. Less disruption of these tissues could translate to better patient outcomes, such as reduced post-operative pain, increased range of motion, reduced instances of patellar maltracking or necrosis, and a shorter recovery time. To determine if adequate exposure could be achieved, the length of the skin incision and perimeter of surgical exposure was compared amongst 22 paired fresh-frozen cadaveric lower limbs (five females/six males) which underwent TKA using the SLA or MPA approach. Additionally, subjective observations which included the percent of visibility of the femoral condyles and tibial plateau, as well as the patellar tracking, were noted in order to qualify adequate exposure. All procedures were conducted by the same surgeon. Subsequently, to determine the extent of soft tissue damage associated with the approaches, an observational assessment of the dynamic and static structures of the knee was performed, in addition to an examination of the microneurovascular structures involved. Dynamic and static structures were assessed by measuring the extent of muscular and ligamentus damage during gross dissection of the internal compartment of the knee. Microneurovascular involvement was evaluated through a microscopic histological examination of the tissue harvested adjacent to the capsular incision. Comparison of the mean exposure perimeter and length of incision was not significantly different between the SLA and the MPA (p>0.05). In fact, on average, the SLA facilitated a 5 mm larger exposure perimeter to the internal compartment, with an 8 mm smaller incision, compared to the MPA, additional investigation is required to assert the clinical implications of these findings. Preliminary analysis of the total visibility of the femoral condyles were comparable between the SLA and MPA, though the tibial plateau visibility appears slightly reduced in the SLA. Analyses of differences in soft tissue damage are in progress. Adequate exposure to the internal compartment of the knee can be achieved using an incision of similar length when the SLA to TKA is performed, compared to the standard MPA. Future studies should evaluate the versatility of the SLA through an examination of specimens with a known degree of knee deformity (valgus or varus)


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 195 - 202
1 Feb 2024
Jamshidi K Kargar Shooroki K Ammar W Mirzaei A

Aims

The epiphyseal approach to a chondroblastoma of the intercondylar notch of a child’s distal femur does not provide adequate exposure, thereby necessitating the removal of a substantial amount of unaffected bone to expose the lesion. In this study, we compared the functional outcomes, local recurrence, and surgical complications of treating a chondroblastoma of the distal femoral epiphysis by either an intercondylar or an epiphyseal approach.

Methods

A total of 30 children with a chondroblastoma of the distal femur who had been treated by intraregional curettage and bone grafting were retrospectively reviewed. An intercondylar approach was used in 16 patients (group A) and an epiphyseal approach in 14 (group B). Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and Sailhan’s functional criteria.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 336 - 336
1 Mar 2013
Song I Lee C
Full Access

Background. We have performed total knee arthroplasties for valgus and varus in the knees of one person and investigate the clinical characteristics of these patients and the relationship between the kind of deformity and postoperative result. Methods. From March 2002 to February 2010, 25 patients who had simultaneous varus and valgus knee deformities underwent total knee arthroplasties and followed more than 12 months were included. The average age was 66.9 years and the average follow-up period was 61.1 months. Follow-up imaging assessments were taken and clinical outcome were evaluated using HSS score at last follow-up. Results. 11 cases had more pain in varus knee and 8 cases had more pain in valgus knee preoperatively. In 11 cases, degenerative scoliosis were associated with the knee deformity and among the cases, 10 cases had valgus deformities in concave side of scoliosis. In three cases, hip deformities were noted in ipsilateral side of the valgus deformity. One case showed both hip deformities with ankylosing spondylitis. Preoperative mean valgus angle was 11.4 degree and varus angle was 7.5 degree. Postoperative valgus and varus angle improved to 6.3 and −5.7 degree. HSS score improved from 64.3 to 84.7 point in valgus deformities and from 62.1 to 85.1 point in varus deformities. Postoperative patellar clunk syndrome was identified in one valgus knee, but resolved by arthroscopic debridement. And postoperatively, one case showed out-toeing gait caused by equinovarus deformity in varus knee, but resolved by correction of foot deformity. Conclusions. Simultaneous or staged total knee arthroplasties in patients with simultaneous varus with contralateral valgus knee deformities brought satisfactory outcomes with regard to objective orthopedic criteria such as radiographic and clinical results. Concave aspect of scoliosis and hip deformity correlate with valgus knee in statistically. But rheumatoid factor and VDRL do not correlate with valgus deformity. And we found no significant difference between the kind of deformity and postoperative result


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 32 - 32
1 May 2019
Gross A
Full Access

An osteochondral defect greater than 3cm in diameter and 1cm in depth is best managed by an osteochondral allograft. If there is an associated knee deformity, then an osteotomy is performed. In our series of osteochondral allografts for large post-traumatic knee defects realignment osteotomy is performed about 60% of the time in order to off-load the transplant. To correct varus we realign the proximal tibia with an opening wedge osteotomy. To correct valgus, we realign the distal femur with a closing wedge osteotomy. Our results with osteochondral allografts for the large osteochondral defects of the knee both femur and tibia, have been excellent in 85% of patients at an average follow-up of 10 years. The Kaplan-Meier survivorship at 15 years is 72%. At an average follow-up of 22 years in 58 patients with distal femoral osteochondral allograft, 13 have been revised (22%). The 15-year survivorship was 84%. Retrieval studies of 24 fresh osteochondral grafts obtained at graft revision or conversion total knee replacement at an average of 12 years (5 – 25) revealed the following. In the areas where the graft was still intact, the cartilage was of normal thickness and architecture. Matrix staining was normal except in the superficial and upper mid zones. Chondrocytes were mostly viable but there was chondrocyte clusters and loss of chondrocyte polarity. Host bone had extended to the calcified cartilage but variable remnants of dead bone surrounded by live bone persisted. With a stable osseous base the hyaline cartilage portion of the graft can survive for up to 25 years


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 59 - 59
1 Feb 2020
Zhang J Bhowmik-Stoker M Yanoso-Scholl L Condrey C Marchand K Marchand R
Full Access

Introduction. Valgus deformity in an end stage osteoarthritic knee can be difficult to correct with no clear consensus on case management. Dependent on if the joint can be reduced and the degree of medial laxity or distension, a surgeon must use their discretion on the correct method for adequate lateral releases. Robotic assisted (RA) technology has been shown to have three dimensional (3D) cut accuracy which could assist with addressing these complex cases. The purpose of this work was to determine the number of soft tissue releases and component orientation of valgus cases performed with RA total knee arthroplasty (TKA). Methods. This study was a retrospective chart review of 72 RATKA cases with valgus deformity pre-operatively performed by a single surgeon from July 2016 to December 2017. Initial and final 3D component alignment, knee balancing gaps, component size, and full or partial releases were collected intraoperatively. Post-operatively, radiographs, adverse events, WOMAC total and KOOS Jr scores were collected at 6 months, 1 year and 2 year post-operatively. Results. Pre-operatively, knee deformities ranged from reducible knees with less than 5mm of medial laxity to up to 12° with fixed flexion contracture. All knees were corrected within 2.5 degrees of mechanical neutral. Average femoral component position was 0.26. o. valgus, and 4.07. o. flexion. Average tibial component position was 0.37. o. valgus, and 2.96. o. slope, where all tibial components were placed in a neutral or valgus orientation. Flexion and extension gaps were within 2mm (mean 1mm) for all knees. Medial and lateral gaps were balanced 100% in extension and 93% in flexion. The average flexion gap was 18.3mm and the average extension gap was 18.7mm. For component size prediction, the surgeon achieved their planned within one size on the femur 93.8% and tibia 100% of the time. The surgeon upsized the femur in 6.2% of cases. Soft tissue releases were reported in one of the cases. At latest follow-up, radiographic evidence suggested well seated and well fixed components. Radiographs also indicated the patella components were tracking well within the trochlear groove. No revision and re-operation is reported. Mean WOMAC total scores were improved from 24±8.3 pre-op to 6.6±4.4 2-year post-op (p<0.01). Mean KOOS scores were improved from 46.8±9.7 pre-op to 88.4±13.5 2-year post-op (p<0.01). Discussion. In this retrospective case review, the surgeon was able to balance the knee with bone resections and avoid disturbing the soft tissue envelope in valgus knees with 1–12° of deformity. To achieve this balance, the femoral component was often adjusted in axial and valgus rotations. This allowed the surgeon to open lateral flexion and extension gaps. While this study has several limitations, RATKA for valgus knees should continue to be investigated. For any figures or tables, please contact authors directly


Bone & Joint 360
Vol. 12, Issue 2 | Pages 42 - 44
1 Apr 2023

The April 2023 Research Roundup360 looks at: Ear protection for orthopaedic surgeons?; Has arthroscopic meniscectomy use changed in response to the evidence?; Time to positivity of cultures obtained for periprosthetic joint infection; Bisphosphonates for post-COVID-19 osteonecrosis of the femoral head; Missing missed fractures: is AI the answer?; Congenital insensitivity to pain and correction of the knee; YouTube and paediatric elbow injuries.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 16 - 19
1 Apr 2023

The April 2023 Knee Roundup360 looks at: Does bariatric surgery reduce complications after total knee arthroplasty?; Mid-flexion stability in total knee arthroplasties implanted with kinematic alignment: posterior-stabilized versus medial-stabilized implants; Inflammatory response in robotic-arm-assisted versus conventional jig-based total knee arthroplasty; Journey II bicruciate stabilized (JII-BCS) and GENESIS II total knee arthroplasty: the CAPAbility, blinded, randomized controlled trial; Lifetime risk of revision and patient factors; Platelet-rich plasma use for hip and knee osteoarthritis in the USA; Where have the knee revisions gone?; Tibial component rotation in total knee arthroplasty: CT-based study of 1,351 tibiae.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 109 - 116
8 Feb 2024
Corban LE van de Graaf VA Chen DB Wood JA Diwan AD MacDessi SJ

Aims

While mechanical alignment (MA) is the traditional technique in total knee arthroplasty (TKA), its potential for altering constitutional alignment remains poorly understood. This study aimed to quantify unintentional changes to constitutional coronal alignment and joint line obliquity (JLO) resulting from MA.

Methods

A retrospective cohort study was undertaken of 700 primary MA TKAs (643 patients) performed between 2014 and 2017. Lateral distal femoral and medial proximal tibial angles were measured pre- and postoperatively to calculate the arithmetic hip-knee-ankle angle (aHKA), JLO, and Coronal Plane Alignment of the Knee (CPAK) phenotypes. The primary outcome was the magnitude and direction of aHKA, JLO, and CPAK alterations.