Aims. The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery. Methods. Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines. Results. Current PPE appears to mitigate more than 90% of
Aims. Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to
As an increasing number of female surgeons are choosing orthopaedics, it is important to recognize the impact of pregnancy within this cohort. The aim of this review was to examine common themes and data surrounding pregnancy, parenthood, and fertility within orthopaedics. A systematic review was conducted by searching Medline, Emcare, Embase, PsycINFO, OrthoSearch, and the Cochrane Library in November 2022. The Preferred Reporting Items for Systematic Reviews and Meta Analysis were adhered to. Original research papers that focused on pregnancy and/or parenthood within orthopaedic surgery were included for review.Aims
Methods
Aims. To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Methods. Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of
Aims. To monitor the performance of services for developmental dysplasia of the hip (DDH) in Northern Ireland and identify potential improvements to enhance quality of service and plan for the future. Methods. This was a prospective observational study, involving all infants treated for DDH between 2011 and 2017. Children underwent clinical assessment and radiological investigation as per the regional surveillance policy. The regional radiology data was interrogated to quantify the use of ultrasound and
Introduction. Diagnosis of osteoarthritis relies primarily on image-based analyses. X-ray, CT, and MRI can be used to evaluate various features associated with OA including joint space narrowing, deformity, articular cartilage integrity, and other joint parameters. While effective, these exams are costly, may expose the patient to
Aim of the study was the evaluation of the efficacy of the use of a new wearable AR video see-throught system based on Head Mounted Displays (HMDs) to guide the position of a working cannula into the vertebral body through a transpedicular approach without the use X-Ray images guidance. We describe a head mounted stereoscopic video see-through display that allows the augmentation of video frames acquired by two cameras with the rendering of patient specific 3D models obtained on the basis of pre-operative radiological volumetric images. The system does not employ any external tracker to detect movements of the user or of the patient. User's head movements and the consistent alignment of the virtual patient with the real one, are accomplished through machine vision methods applied on pairs of live images. Our system has been tested on an experimental setup that simulate the reaching of lumbar pedicle as in a vertebral augmentation procedure avoiding the employment of
The nature of the Aneurysmal Bone Cyst (ABC) is still controversial among benign tumor, often identifiable in the “aggressive” form (Enneking stage 3) or pseudotumoral lesion. It is well known instead the very high risk of intraoperative bleeding, indicating a strongly unfavorable relationship between the surgical morbidity and the nature of the disease. Recently, excellent results have been obtained in the treatment of ABC by repeated arterial embolizations (SAE), without any surgery, while initial experiences with administration of denosumab and doxycycline are still under study. This study presents the results of our initial experience in the treatment of vertebral ABC through the use of concentrated autologous mesenchymal stem cells (MSCs). Two teenagers aged 15 years, male, and 14 years, female, came to our attention both with diagnosis of ABC in C2 vertebra which was histologically confirmed. They were both neurologically intact, the girl complained of neck pain. The arteriography showed in both cases close relationships between the pathological ABC vascularization and the vertebral and cervical ascending arteries, making treatment by selective arterial embolization unsuitable. After discussion with the parents of patients, we jointly decided to undertake the treatment by direct injection of MSCs preceded, in the same operative session, by harvesting from the iliac crest of 60 cc of bone marrow (by needle aspiration) and its separation with the use of concentration system Res-Q ™ 60 BMC. In the second case the treatment was repeated two times at distance of 4 months. The clinical and radiological follow-up is to of 30 months from the first treatment in both cases. In the first case the presence of newly formed bone within the ABC appeared as a clear sign of recovery just a month after the first treatment and increased gradually, until the cyst appeared completely ossified one year after the treatment, with associated disappearance of the pain. In the second case an initial sclerotic peripheral margin appeared after the second treatment and later ossification progressed, concurrently with the disappearance of the pain. Treatment with selective serial arterial embolization is considered effective in the treatment of ABC even if not without risks, mainly related to the frequent and repeated exposure to
Aim: Accurate placement of the distal screws into the interlocking nails is a demanding procedure due in part to inaccuracy of the targeting device supplied with the system and to deformation of the nail during insertion. Distal locking can be time consuming and expose the surgeon to unnecessary increased
Most types of bone tumor surgery require intra-operative imaging or measurement to control margins and prevent unnecessary bone loss. Computer Assisted Surgery (CAS) has been used as a replacement of fluoroscopy or direct measurement tools in four specific types of oncological orthopaedic surgical approaches. There are intralesional treatments, image-based resections, image-based resections with image-based reconstructions and image-based resections with imageless tumor prostheses reconstruction. Since 2006 we have performed 130 oncological surgeries with CAS. Most cases were excochleations, 64, where CAS replaces fluoroscopy as an intra-operative imaging modality. Advantages over fluoroscopy are real time three dimensional feedback, high-res image and no use of
Non-invasive, in vivo measurement of the three-dimensional (3-D) motion of the tibiofemoral joint is essential for the study of the biomechanics and functional assessment of the knee. Real-time magnetic resonance imaging (MRI) techniques enable the measurement of dynamic motions of the knee with satisfactory image quality and free of radiation exposures but are limited to planar motions in selected slice(s). The aims of the current study were to propose a slice-to-volume registration (SVR) method in conjunction with dual-slice, real-time MRI for measuring 3-D tibiofemoral motion; and to evaluate its repeatability during passive knee flexion. Eight healthy young adults participated in the current study, giving informed written consent as approved by the Institutional Research Board. A 3-T MRI system (Verio, Siemens, Erlangen, Germany) incorporated with a neck matrix coil was used to collect the MRI data. A 3-D scanning using the VIBE sequence was used to collect the volumetric data of the knee at fully extended position (TR = 4.64 ms, TE = 2.3 ms, flip angle = 15°, in-plane resolution = 0.39 × 0.39 mm. 2. and slice thickness = 0.8 mm). A real-time MRI using the refocused radial FLASH sequence (TR = 4.3 ms, TE = 2.3 ms, flip angle = 20°, in-plane resolution = 1.0 × 1.0 mm. 2. , slice thickness = 6 mm) was used to acquire a pair of image slices of the knee at a frame rate of 3 fps during passive flexion. The volumetric MRI data sets were segmented for the femur and tibia/fibula to isolate the sub-volumes containing bone segments. A slice-to-volume registration method was then performed to determine the 3-D poses of the bones based on the spatial matching between sub-volume of the bones and the real-time image slices. The bone poses for all frames were used to calculate the rigid-body kinematics of the tibiofemoral joint in terms of the flexion/extension (FE), internal/external rotation (IR/ER), abduction/adduction (Abd/Add) and joint center translations along three anatomical axis of the tibia. The procedures were carried out five times for repeatability analysis. The standard deviation (SD) of the rigid-body kinematics for each frame from the five trials were calculated and then averaged across all frames to give quantitative measures of the repeatability of the kinematic variables. The repeatability analysis showed that the mean±SD of the averaged SD in FE, Abd/Add and IR/ER components across all subjects were 0.25±0.09, 0.46±0.13 and 0.77±0.16 degrees, respectively. The corresponding values for the joint translations in anterior/posterior, proximal/distal and medial/lateral directions were 0.21±0.04, 0.11±0.03 and 0.43±0.09 mm. An SVR method in conjunction with dual-slice real-time MRI has been successfully developed and its repeatability in measuring 3-D motion of the tibiofemoral joint evaluated. The results show that the proposed method is capable of providing rigid-body kinematics with sub-millimeter and sub-degree precision (repeatability). The proposed SVR method using real-time MRI will be a valuable tool for non-invasive, functional assessment of the knee without involving
Introduction: The Ganz periacetabular osteotomy aims to improve femoral head coverage in dysplastic hips. It is joint preserving procedure and therefore is ideally preformed before significant articular cartilage degeneration. One proposed advantage of this procedure is that it partially preserves the posterior column and does not disrupt the vascular supply of the main fragment. This study aims to 1) assess the role of MR imaging in the perioperative evaluation of articular cartilage and labrial tissues prior to Ganz osteotomies and 2) to document any alteration in the vascularity of the acetabular fragment post operatively. Patient and Methods: Twenty patients (all female, average age 18.2 years) under consideration for peracetabular osteotomy for hip dysplasia and MR Studies of the pelvis as part of the perioperative assessment. Sixteen patients had follow-up imaging at 4, 12 and 26 weeks post surgery, at which time evidence of healing, oedema, vascularity and femoral head coverage were assessed. Discussion: MR imaging has proven to be a reliable method of assessing articular cartilage health before considering pelvic osteotomy. Hopefully this will allow more appropriate selection of patients likely to benefit from this procedure. In addition MRI scanning allows clearer assessment of other articular elements, such as labium and ligamentum teres, that are difficult to visualize with plain radiographs and CT scans. A further benefit of MR scanning is that, as this study has shown the vast majority of patients who are potential candidates are female of childbearing age and it voids the use of
Background: The late effect of
We evaluated the accuracy of a Magnetic Resonance Imaging (MRI)-based method to measure three-dimensional patellar tracking during loaded knee flexion. This method determines the relative positions of the knee bones by shape matching high-resolution three-dimensional geometric models of these bones to fast low-resolution scans taken during loaded flexion. The accuracy of the method’s assessment of patellar position and orientation was determined by comparing test measurements in four cadaver specimens to measurements made in the same specimens using Roentgen Stereophotogrammetric Analysis (RSA). This MRI-based method is more accurate than current two-dimensional imaging methods. The purpose of this study was to determine the accuracy of a MRI-based technique for measuring patellar tracking in loaded flexion. This novel, noninvasive, MRI-based method measures three-dimensional patellar tracking during loaded knee flexion with sufficient accuracy to detect clinically significant changes. Although abnormal patellar tracking is widely believed to be associated with pain and cartilage degeneration at the patella, these relationships have not been clearly established because most current methods assess only the two-dimensional alignment of the patella at one position. Measurements possible with this method should be sufficiently accurate to yield new insights into these relationships. Four cadaver knee specimens were flexed through seventy-five degrees of flexion in an MRI-compatible knee loading rig. A high-resolution image was acquired with each knee in extension and then a series of low-resolution scans (in two slice directions: axial and sagittal) were acquired through a flexion cycle. Segmenting bone outlines from high-resolution scans generated models of the femur, tibia and patella. These models were shape matched to the segmented bone outlines in the low resolution scans. Patellar attitude and position were determined and compared to measurements made using RSA. The mean measurement error in every kinematic parameter was lower for “fast” sagittal plane slices than for “fast” axial plane slices. In general, the mean measurement error was increased by decreasing the number of low-resolution slices. This method is more accurate than many two-dimensional methods, exposes participants to no
Introduction: Accurate and quantitative measurements of the spine are essential for deformity diagnosis and assessment of curve progression. There is much concern related to the multiple exposures to
Summary Statement. DNA damage induced by systemic drugs or local γ-irradiation drives disc degeneration and DNA repair ability is extremely important to help prevent bad effects of genotoxins (DNA damage inducing agents) on disc. Introduction. DNA damage (genotoxic stress) and deficiency of intracellular DNA repair mechanisms strongly contribute to biological aging. Moreover, aging is a primary risk factor for loss of disc matrix proteoglycan (PG) and intervertebral disc degeneration (IDD). Indeed, our previous evidences in DNA repair deficient Ercc1−/Δ mouse model strongly suggest that systemic aging and IDD correlate with nuclear DNA damage. Thus the aim of the current study was to test whether systemic or local (spine) genotoxic stress can induce disc degeneration and how DNA repair ability could help prevent negative effects of DNA damage on IDD. To test this hypothesis a total of twelve Ercc1−/Δ mice (DNA repair deficient) and twelve wild-type mice (DNA repair competent) were challenged with two separate genotoxins to induce DNA damage, i.e. chemotherapeutic crosslinking agent mechlorethamine (MEC) and whole-body gamma irradiation. Local effects of gamma irradiation were also tested in six wild-type mice. Methods. Ercc1. −/Δ. mice (n=6) and their wild-type littermates were chronically exposed to genotoxic stress beginning at 8 wks of age by subcutaneous administration of a subtoxic dose of MEC (8 μg/kg once per week for 6 weeks). Similarly, six Ercc1. −/Δ. mice and their wild-type littermates were exposed to genotoxic stress by whole-body administration of ∼10% radiotherapeutic dose of
Highly cross-linked polyethylene (HXLPE) greatly reduces wear in total hip arthroplasty, compared to conventional polyethylene (CPE). Cross-linking is commonly achieved by irradiation. This study aimed to compare the degree of cross-linking and in vitro wear rates across a cohort of retrieved and unused polyethylene cups/liners from various brands. Polyethylene acetabular cups/liners were collected at one centre from 1 April 2021 to 30 April 2022. The trans-vinylene index (TVI) and oxidation index (OI) were determined by Fourier-transform infrared spectrometry. Wear was measured using a pin-on-disk test.Aims
Methods
Recurrent dislocation is both a cause and consequence of glenoid bone loss, and the extent of the bony defect is an indicator guiding operative intervention. Literature suggests that loss greater than 25% requires glenoid reconstruction. Measuring bone loss is controversial; studies use different methods to determine this, with no clear evidence of reproducibility. A systematic review was performed to identify existing CT-based methods of quantifying glenoid bone loss and establish their reliability and reproducibility A Preferred Reporting Items for Systematic reviews and Meta-Analyses-compliant systematic review of conventional and grey literature was performed.Aims
Methods