Advertisement for orthosearch.org.uk
Results 1 - 20 of 321
Results per page:
Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 215 - 215
1 May 2009
Qureshi AA Roberts A
Full Access

Aim: To assess the Interobserver Reliability of the Sauvegrain Skeletal Age Assessment. Methods and Results: Elbow radiographs requested to exclude injury were anonymised. Sixteen examinations were assessed by ten independent orthopaedic specialist registrars or consultants. The Sauvegrain method as modified by Dimeglio was used to score the radiographs. The observations made were then assessed for interobserver reliability by means of a multiple observer Kappa score and the total scores by intra-class correlation coefficient. Kappa scores for the components of the score were 0.403 for the lateral condyle; 0.492 for the trochlea; 0.354 for the proximal radius and 0.508 for the olecranon. Adding item scores to produce a modified Sauvegrain score had an intra-class reliability of 0.858 (95% CI 0.758 to 0.935). Conclusions: Methods of identifying skeletal maturation and predicting future growth generally depend on the use of an atlas of hand radiographs. Difficulties with poor interobserver reliability associated with these methods have led to a move towards assessments that do not depend upon bone age estimations. Unfortunately plans based on ratios of growth or average patterns produce errors when unusual types of growth disturbance are present. We conclude that use of a scoring system for maturation assessed by elbow radiographs offers a significant advantage when substituted into the straight-line method of growth prediction. The Sauvegrain method as modified by Dimeglio. 1. has demonstrated an excellent level of interobserver reliability. We have used Sauvegrain scores to improve the accuracy of timing when using the Mosely straight-line method. 3.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 670 - 672
1 Jul 1998
Flinkkilä T Nikkola-Sihto A Kaarela O Päakkö E Raatikainen T

Interobserver reliability of the AO system of classification of fractures of the distal radius was assessed using plain radiographs and CT. Five observers classified 30 Colles’-type fractures using only plain radiographs; two months later they were reclassified using CT in addition. Interobserver reliability was poor in both series when detailed classification was used. By reducing the categories to five, interobserver reliability was slightly improved, but was still poor. When only two AO types were used, the reliability was moderate using plain radiographs and good to excellent with the addition of CT. The use of CT as well as plain radiographs brings interobserver reliability to a good level in assessment of the presence or absence of articular involvement, but is otherwise of minor value in improving the interobserver reliability of the AO system of classification of fractures of the distal radius


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 38 - 38
1 Jan 2011
Qureshi A Roberts A
Full Access

The purpose of this study was to assess the Interobserver Reliability of the Sauvegrain Skeletal Age Assessment. Elbow radiographs requested to exclude injury were anonymised. Sixteen examinations were assessed by ten independent orthopaedic specialist registrars or consultants. The Sauvegrain method as modified by Dimeglio was used to score the radiographs. The observations made were then assessed for interobserver reliability by means of a multiple observer Kappa score and the total scores by intra-class correlation coefficient. Kappa scores for the components of the score were 0.403 for the lateral condyle; 0.492 for the trochlea; 0.354 for the proximal radius and 0.508 for the olecranon. Adding item scores to produce a modified Sauvegrain score had an intraclass reliability of 0.858 (95% CI 0.758 to 0.935). Methods of identifying skeletal maturation and predicting future growth generally depend on the use of an atlas of hand radiographs. Difficulties with poor interobserver reliability associated with these methods has led to a move towards assessments that do not depend upon bone age estimations. Unfortunately plans based on ratios of growth or average patterns produce errors when unusual types of growth disturbance are present. We conclude that use of a scoring system for maturation assessed by elbow radiographs offers a significant advantage when substituted into the straight line method of growth prediction. The Sauvegrain method as modified by Dimeglio1 has demonstrated an excellent level of inter observer reliability. We have used Sauvegrain scores to improve the accuracy of timing when using the Mosely straight line method


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_I | Pages 49 - 49
1 Jan 2012
Brunse M Stochkendahl M Vach W Kongsted A Poulsen E Hartvigsen J Christensen H
Full Access

Background and purpose. The musculoskeletal system is recognized as a possible source of pain in patients with chest pain. The objectives of the present study were (1) to investigate the interobserver reliability of an overall diagnosis of musculoskeletal chest pain using a standardized examination protocol in a cohort of patients with chest pain suspected to be of non-cardiac origin, (2) to investigate the interobserver reliability of the single components of the protocol, and finally, (3) to investigate the importance of clinical experience on the level of interobserver reliability. Methods and results. Eighty patients with acute chest pain were recruited from a cardiology department. Four observers (two chiropractors and two chiropractic students) performed a physical examination and an extended manual examination of the spine and chest wall. Percentage agreement, Cohen's Kappa and ICC were calculated for observer pairs and overall. Musculoskeletal chest pain was diagnosed in 44.0 % of patients. Interobserver kappa values were substantial for the chiropractors and overall, and moderate for the students. For single items of the protocol, both pairs showed fair to substantial agreement regarding pain provocation tests and poor to fair agreement regarding spinal segmental dysfunction tests. Conclusions. Suspected musculoskeletal chest pain can be identified with substantial interobserver reliability using this standardized protocol if used by experienced and trained observers. Agreement for individual components of the protocol showed, however, considerable variation. Provided training of observers, the examination protocol can be used in selected patients and can be implemented in pre- and post-graduate clinical training


Aims. Classifying trochlear dysplasia (TD) is useful to determine the treatment options for patients suffering from patellofemoral instability (PFI). There is no consensus on which classification system is more reliable and reproducible for the purpose of guiding clinicians’ management of PFI. There are also concerns about the validity of the Dejour Classification (DJC), which is the most widely used classification for TD, having only a fair reliability score. The Oswestry-Bristol Classification (OBC) is a recently proposed system of classification of TD, and the authors report a fair-to-good interobserver agreement and good-to-excellent intraobserver agreement in the assessment of TD. The aim of this study was to compare the reliability and reproducibility of these two classifications. Methods. In all, six assessors (four consultants and two registrars) independently evaluated 100 axial MRIs of the patellofemoral joint (PFJ) for TD and classified them according to OBC and DJC. These assessments were again repeated by all raters after four weeks. The inter- and intraobserver reliability scores were calculated using Cohen’s kappa and Cronbach’s α. Results. Both classifications showed good to excellent interobserver reliability with high α scores. The OBC classification showed a substantial intraobserver agreement (mean kappa 0.628; p < 0.005) whereas the DJC showed a moderate agreement (mean kappa 0.572; p < 0.005). There was no significant difference in the kappa values when comparing the assessments by consultants with those by registrars, in either classification system. Conclusion. This large study from a non-founding institute shows both classification systems to be reliable for classifying TD based on axial MRIs of the PFJ, with the simple-to-use OBC having a higher intraobserver reliability score than that of the DJC. Cite this article: Bone Jt Open 2023;4(7):532–538


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 3 - 3
3 Mar 2023
Roy K Joshi P Ali I Shenoy P Syed A Barlow D Malek I Joshi Y
Full Access

Classifying trochlear dysplasia (TD) is useful to determine the treatment options for patients suffering from patellofemoral instability (PFI). There is no consensus on which classification system is more reliable and reproducible for this purpose to guide clinicians in order to treat PFI. There are also concerns about validity of the Dejour classification (DJC), which is the most widely used classification for TD, having only a fair reliability score. The Oswestry-Bristol classification (OBC) is a recently proposed system of classification of TD and the authors report a fair-to-good interobserver agreement and good-to-excellent intra-observer agreement in the assessment of TD. The aim of this study was to compare the reliability and reproducibility of these two classifications. 6 assessors (4 consultants and 2 registrars) independently evaluated 100 magnetic resonance axial images of the patella-femoral joint for TD and classified them according to OBC and DJC. These assessments were again repeated by all raters after 4 weeks. The inter and intra-observer reliability scores were calculated using Cohen's kappa and Cronbach's alpha. Both classifications showed good to excellent interobserver reliability with high alpha scores. The OBC classification showed a substantial intra-observer agreement (mean kappa 0.628)[p<0.005] whereas the DJC showed a moderate agreement (mean kappa 0.572) [p<0.005]. There was no significant difference in the kappa values when comparing the assessments by consultants to those by registrars, in either classification systems. This large study from a non-founding institute shows both classification systems to be reliable for classifying TD based on magnetic resonance axial images of the patella-femoral joint, with the simple to use OBC having a higher intra-observer reliability score compared to the DJC


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 242 - 246
1 Feb 2018
Ghoshal A Enninghorst N Sisak K Balogh ZJ

Aims. To evaluate interobserver reliability of the Orthopaedic Trauma Association’s open fracture classification system (OTA-OFC). Patients and Methods. Patients of any age with a first presentation of an open long bone fracture were included. Standard radiographs, wound photographs, and a short clinical description were given to eight orthopaedic surgeons, who independently evaluated the injury using both the Gustilo and Anderson (GA) and OTA-OFC classifications. The responses were compared for variability using Cohen’s kappa. Results. The overall interobserver agreement was ĸ = 0.44 for the GA classification and ĸ = 0.49 for OTA-OFC, which reflects moderate agreement (0.41 to 0.60) for both classifications. The agreement in the five categories of OTA-OFC was: for skin, ĸ = 0.55 (moderate); for muscle, ĸ = 0.44 (moderate); for arterial injury, ĸ = 0.74 (substantial); for contamination, ĸ = 0.35 (fair); and for bone loss, ĸ = 0.41 (moderate). Conclusion. Although the OTA-OFC, with similar interobserver agreement to GA, offers a more detailed description of open fractures, further development may be needed to make it a reliable and robust tool. Cite this article: Bone Joint J 2018;100-B:242–6


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 151 - 151
1 Feb 2003
Al-lami M Fourie B Koreli A Finn P Wilson S Gregg P
Full Access

The Department of Health and the Public Health Laboratory Service established the Nosocomial Infection National Surveillance Scheme (NINSS) in response to the need to standardise the collection of information about infections acquired in hospital. This would provide national data that could be used as a ‘benchmark’ by hospitals to measure their own performance. The definition of superficial incisional infection (skin and subcutaneous tissue), set by Centers of Disease Control (CDC), should meet at least one of the following criteria: I: Purulent drainage from the superficial incision. II: The superficial incision yields organisms from the culture of aseptically aspirated fluid or tissue, or from a swab, and pus cells are present. III: At least two of the following symptoms and signs of inflammation: pain or tenderness, localized swelling, redness or heat, and a. the superficial incision is deliberately opened by a surgeon to manage the infection, unless the incision is culture-negative or b. clinician’s diagnosis of superficial incisional infection. This study assessed the interobserver reliability of the superficial incisional infection criteria, set by the CDC, in current practice. The incisional site of 50 consecutive patients, who underwent elective primary joint arthroplasty (Hips & Knees), were evaluated independently by four observers. The most significant results of the study I: All four observers achieved absolute agreement (kappa=1) for Purulent wound discharge and clinical diagnosis of wound infection. II: The four observers obtained good agreement for pain criteria (kappa=0.76, III: There was significant disagreement (fair to poor) between all four observers for the following criteria: Localized swelling (kappa=0.34), Redness (kappa=0.33) and tenderness (kappa = 0.05). This is the first study to assess the reliability of the criteria, as set by the CDC and recommended by NINSS, for the diagnosis of superficial incisional infection and shows the Criterion III is not reliable and we recommend it should be revised. Failure to do so could lead to inaccurate statistics regarding hospital wound infection and detrimental effect on hospital trusts in the setting of league table


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 187 - 187
1 Mar 2006
Maguire M Mohil R Ng A Hodgson S
Full Access

The AO, Frykman, Mayo and Fernandez classification system for distal radius fractures were evaluated for interobserver reliability and intraobserver reproducibility using plain radiographs. Five orthopaedic consultants, five orthopaedic registras and five orthopaedic senior house officers classified 20 sets of distal radius fractures on two seperate occasions. There were 2400 induvidual observations. Kappa statistics were used to establish a relative level of agreement between observers for the two readings and between seperate readings by the same observer. Our results for intraobserver reproducibility showed Fernandez Kappa value of 0.49, Frykman 0.47, Mayo 0.45 and AO 0.33. A 0.4 result shows good consistecy accorcing to well reconised staistical boundries and is significant. That is reproducibility happened at a level greater than by chance. Interobserver Kappa values were poor in all classification systems. We also sought to look at varibles within grade of surgeon and developed Kappa values for these also


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 12 - 12
4 Jun 2024
Chapman J Choudhary Z Gupta S Airey G Mason L
Full Access

Introduction

Treatment pathways of 5th metatarsal fractures are commonly directed based on fracture classification, with Jones types for example, requiring closer observation and possibly more aggressive management.

Primary objective

To investigate the reliability of assessment of subtypes of 5th metatarsal fractures by different observers.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 27 - 27
23 Jun 2023
Chen K Wu J Xu L Han X Chen X
Full Access

To propose a modified approach to measuring femoro-epiphyseal acetabular roof (FEAR) index while still abiding by its definition and biomechanical basis, and to compare the reliabilities of the two methods. To propose a classification for medial sourcil edges.

We retrospectively reviewed a consecutive series of patients treated with periacetabular osteotomy and/or hip arthroscopy. A modified FEAR index was defined. Lateral center-edge angle, Sharp's angle, Tonnis angle on all hips, as well as FEAR index with original and modified approaches were measured. Intra- and inter-observer reliability were calculated as intraclass correlation coefficients (ICC) for FEAR index with both approaches and other alignments. A classification was proposed to categorize medial sourcil edges. ICC for the two approaches across different sourcil groups were also calculated.

After reviewing 411 patients, 49 were finally included. Thirty-two patients (40 hips) were identified as having borderline dysplasia defined by an LCEA of 18 to 25 degrees. Intra-observer ICC for the modified method were good to excellent for borderline hips; poor to excellent for DDH; moderate to excellent for normal hips. As for inter-observer reliability, modified approach outperformed original approach with moderate to good inter-observer reliability (DDH group, ICC=0.636; borderline dysplasia group, ICC=0.813; normal hip group, ICC=0.704). The medial sourcils were classified to 3 groups upon its morphology. Type II(39.0%) and III(43.9%) sourcils were the dominant patterns. The sourcil classification had substantial intra-observer agreement (observer 4, kappa=0.68; observer 1, kappa=0.799) and moderate inter-observer agreement (kappa=0.465). Modified approach to FEAR index possessed greater inter-observer reliability in all medial sourcil patterns.

The modified FEAR index has better intra- and inter-observer reliability compared with the original approach. Type II and III sourcils accounts for the majority to which only the modified approach is applicable.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 478 - 484
1 Apr 2020
Daniels AM Wyers CE Janzing HMJ Sassen S Loeffen D Kaarsemaker S van Rietbergen B Hannemann PFW Poeze M van den Bergh JP

Aims

Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture.

Methods

Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 116 - 121
1 Apr 2016
Leow JM Clement ND Tawonsawatruk T Simpson CJ Simpson AHRW

Objectives

The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison.

Methods

A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 962 - 970
4 Nov 2024
Suter C Mattila H Ibounig T Sumrein BO Launonen A Järvinen TLN Lähdeoja T Rämö L

Aims. Though most humeral shaft fractures heal nonoperatively, up to one-third may lead to nonunion with inferior outcomes. The Radiographic Union Score for HUmeral Fractures (RUSHU) was created to identify high-risk patients for nonunion. Our study evaluated the RUSHU’s prognostic performance at six and 12 weeks in discriminating nonunion within a significantly larger cohort than before. Methods. Our study included 226 nonoperatively treated humeral shaft fractures. We evaluated the interobserver reliability and intraobserver reproducibility of RUSHU scoring using intraclass correlation coefficients (ICCs). Additionally, we determined the optimal cut-off thresholds for predicting nonunion using the receiver operating characteristic (ROC) method. Results. The RUSHU demonstrated good interobserver reliability with an ICC of 0.78 (95% CI 0.72 to 0.83) at six weeks and 0.77 (95% CI 0.71 to 0.82) at 12 weeks. Intraobserver reproducibility was good or excellent for all analyses. Area under the curve in the ROC analysis was 0.83 (95% CI 0.77 to 0.88) at six weeks and 0.89 (95% CI 0.84 to 0.93) at 12 weeks, indicating excellent discrimination. The optimal cut-off values for predicting nonunion were ≤ eight points at six weeks and ≤ nine points at 12 weeks, providing the best specificity-sensitivity trade-off. Conclusion. The RUSHU proves to be a reliable and reproducible radiological scoring system that aids in identifying patients at risk of nonunion at both six and 12 weeks post-injury during non-surgical treatment of humeral shaft fractures. The statistically optimal cut-off values for predicting nonunion are ≤ eight at six weeks and ≤ nine points at 12 weeks post-injury


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1345 - 1350
1 Aug 2021
Czubak-Wrzosek M Nitek Z Sztwiertnia P Czubak J Grzelecki D Kowalczewski J Tyrakowski M

Aims. The aim of the study was to compare two methods of calculating pelvic incidence (PI) and pelvic tilt (PT), either by using the femoral heads or acetabular domes to determine the bicoxofemoral axis, in patients with unilateral or bilateral primary hip osteoarthritis (OA). Methods. PI and PT were measured on standing lateral radiographs of the spine in two groups: 50 patients with unilateral (Group I) and 50 patients with bilateral hip OA (Group II), using the femoral heads or acetabular domes to define the bicoxofemoral axis. Agreement between the methods was determined by intraclass correlation coefficient (ICC) and the standard error of measurement (SEm). The intraobserver reproducibility and interobserver reliability of the two methods were analyzed on 31 radiographs in both groups to calculate ICC and SEm. Results. In both groups, excellent agreement between the two methods was obtained, with ICC of 0.99 and SEm 0.3° for Group I, and ICC 0.99 and SEm 0.4° for Group II. The intraobserver reproducibility was excellent for both methods in both groups, with an ICC of at least 0.97 and SEm not exceeding 0.8°. The study also revealed excellent interobserver reliability for both methods in both groups, with ICC 0.99 and SEm 0.5° or less. Conclusion. Either the femoral heads or acetabular domes can be used to define the bicoxofemoral axis on the lateral standing radiographs of the spine for measuring PI and PT in patients with idiopathic unilateral or bilateral hip OA. Cite this article: Bone Joint J 2021;103-B(8):1345–1350


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims. Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Methods. Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system. Results. At a mean follow-up of 90 months (64 to 130), only two out of 245 cases failed due to aseptic loosening. Intraoperative grading yielded mean scores of 1.87 (95% confidence interval (CI) 1.82 to 1.92) for the femur and 1.96 (95% CI 1.92 to 2.0) for the tibia. Only 3.7% of femoral and 1.7% of tibial reconstructions fell below the 1.5-point threshold, which included the two cases of aseptic loosening. Interobserver reliability for postoperative radiological grading was 0.97 for the femur and 0.85 for the tibia. Conclusion. A minimum score of 1.5 points for each skeletal segment appears to be a reasonable cut-off to define sufficient fixation in rTKA. There were no revisions for aseptic loosening at mid-term follow-up when this fixation threshold was achieved or exceeded. When assessing first-time revisions, this novel grading system has shown excellent intra- and interobserver reliability. Cite this article: Bone Joint J 2024;106-B(5):468–474


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1339 - 1344
1 Aug 2021
Jain S Mohrir G Townsend O Lamb JN Palan J Aderinto J Pandit H

Aims. This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Methods. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs. Results. Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement. Conclusion. This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339–1344


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1380 - 1385
2 Aug 2021
Kim Y Ryu J Kim JK Al-Dhafer BAA Shin YH

Aims. The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function. Methods. We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis. Results. According to Eaton-Glickel classification, 11, 17, 17, and eight hands were stage 0 to I, II, III, and IV, respectively. The interobserver reliability for determining the stage of arthritis was moderate for radiographs (k = 0.41) and substantial for CT scans (k = 0.67). In a binary categorical analysis using SUVmax, pain (p < 0.001) and PRWHE scores (p = 0.004) were significantly higher in hands with higher SUVmax. Using multivariate linear regression to estimate the pain VAS, only SUVmax (B 0.172 (95% confidence interval (CI) 0.065 to 0.279; p = 0.002) showed a significant association. Estimating the variation of PRWHE scores using the same model, only SUVmax (B 1.378 (95% CI, 0.082 to 2.674); p = 0.038) showed a significant association. Conclusion. The CT scans of SPECT/CT provided better interobserver reliability than routine radiographs for evaluating the severity of arthritis. A higher SUVmax in SPECT/CT was associated with more pain and functional disabilities of basal joint arthritis of the thumb. This approach could be used to complement radiographs for the evaluation of patients with this condition. Cite this article: Bone Joint J 2021;103-B(8):1380–1385


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 82 - 82
19 Aug 2024
Courington R Ferreira R Shaath MK Green C Langford J Haidukewych G
Full Access

When treating periprosthetic femur fractures (PPFFs) around total hip arthroplasty (THA)], determining implant fixation status preoperatively is important, since this guides treatment regarding ORIF versus revision. The purpose of this study was to determine the accuracy of preoperative implant fixation status determination utilizing plain films and CT scans. Twenty-four patients who underwent surgery for Vancouver B type PPFF were included in the study. Two joint surgeons and two traumatologists reviewed plain films alone and made a judgment on fixation status. They then reviewed CT scans and fixation status was reassessed. Concordance and discordance were recorded. Interobserver reliability was assessed using Kendall's W and intraobserver reliability was assessed using Cohen's Kappa. Ultimately, the “correct” response was determined by intraoperative findings, as we routinely test the component intraoperatively. Fifteen implants were found to be well-fixed (63%) and 9 were loose. Plain radiographs alone predicted correct fixation status in 53% of cases. When adding the CT data, the correct prediction only improved to 55%. Interestingly, concordance between plain radiographs and CT was noted in 82%. In concordant cases, the fixation status was found to be correct in 55% of cases. Of the 18% of cases with discordance, plain films were correct in 43% of cases, and the CT was correct in 57%. Interobserver reliability demonstrated poor agreement on plain films and moderate agreement on CT. Intraobserver reliability demonstrated moderate agreement on both plain films and CT. The ability to determine fixation status for proximal PPFFs around uncemented femoral components remains challenging. The addition of routine CT scanning did not significantly improve accuracy. We recommend careful intraoperative testing of femoral component fixation with surgical dislocation if necessary, and the surgeon should be prepared to revise or fix the fracture based on those findings


Bone & Joint Research
Vol. 13, Issue 1 | Pages 19 - 27
5 Jan 2024
Baertl S Rupp M Kerschbaum M Morgenstern M Baumann F Pfeifer C Worlicek M Popp D Amanatullah DF Alt V

Aims. This study aimed to evaluate the clinical application of the PJI-TNM classification for periprosthetic joint infection (PJI) by determining intraobserver and interobserver reliability. To facilitate its use in clinical practice, an educational app was subsequently developed and evaluated. Methods. A total of ten orthopaedic surgeons classified 20 cases of PJI based on the PJI-TNM classification. Subsequently, the classification was re-evaluated using the PJI-TNM app. Classification accuracy was calculated separately for each subcategory (reinfection, tissue and implant condition, non-human cells, and morbidity of the patient). Fleiss’ kappa and Cohen’s kappa were calculated for interobserver and intraobserver reliability, respectively. Results. Overall, interobserver and intraobserver agreements were substantial across the 20 classified cases. Analyses for the variable ‘reinfection’ revealed an almost perfect interobserver and intraobserver agreement with a classification accuracy of 94.8%. The category 'tissue and implant conditions' showed moderate interobserver and substantial intraobserver reliability, while the classification accuracy was 70.8%. For 'non-human cells,' accuracy was 81.0% and interobserver agreement was moderate with an almost perfect intraobserver reliability. The classification accuracy of the variable 'morbidity of the patient' reached 73.5% with a moderate interobserver agreement, whereas the intraobserver agreement was substantial. The application of the app yielded comparable results across all subgroups. Conclusion. The PJI-TNM classification system captures the heterogeneity of PJI and can be applied with substantial inter- and intraobserver reliability. The PJI-TNM educational app aims to facilitate application in clinical practice. A major limitation was the correct assessment of the implant situation. To eliminate this, a re-evaluation according to intraoperative findings is strongly recommended. Cite this article: Bone Joint Res 2024;13(1):19–27