Advertisement for orthosearch.org.uk
Results 1 - 20 of 24
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 5 - 5
23 Jan 2024
Awad F Khan F McIntyre J Hathaway L Guro R Kotwal R Chandratreya A
Full Access

Introduction. Anterior cruciate ligament (ACL) injuries represent a significant burden of disease to the orthopaedic surgeon and often necessitate surgical reconstruction in the presence of instability. The hamstring graft has traditionally been used to reconstruct the ACL but the quadriceps tendon (QT) graft has gained popularity due to its relatively low donor site morbidity. Methods. This is a single centre comparative retrospective analysis of prospectively collected data of patients who had an ACL reconstruction (either with single tendon quadrupled hamstring graft or soft tissue quadriceps tendon graft). All surgeries were performed by a single surgeon using the All-inside technique. For this study, there were 20 patients in each group. All patients received the same post-operative rehabilitation protocol and were added to the National Ligament Registry to monitor their patient related outcome scores (PROM). Results. The average age of patients in the QT group was 29 years (16 males, 4 females) and in the hamstring group was 28 years (18 males, 2 females). The most common mechanism of injury in both groups was a contact twisting injury. There were no statistical differences between the two patient groups in regards to PROMS and need for further revision surgery as analysed on the National Ligament Registry. Conclusions. The all soft tissue QT graft seems to be equivocal to quadrupled hamstring graft in terms of patient function and recovery graft characteristics. Further research may be needed to elucidate the long-term results of the all soft tissue QT graft given its recent increase in use


Abstract. Objectives. To determine the effectiveness of LIA compared to ACB in providing pain relief and reducing opiates usage in hamstring graft ACL reconstructions. Materials and Methods. In a consecutive series of hamstring graft ACL reconstructions, patients received three different regional and/or anaesthetic techniques for pain relief. Three groups were studied: group 1: general anaesthetic (GA)+ ACB (n=38); group 2: GA + ACB + LIA (n=31) and group 3: GA+LIA (n=36). ACB was given under ultrasound guidance. LIA involved infiltration at skin incision site, capsule, periosteum and in the hamstring harvest tunnel. Analgesic medications were similar between the three groups as per standard multimodal analgesia (MMA). Patients were similar in demographics distribution and surgical technique. The postoperative pain and total morphine requirements were evaluated and recorded. The postoperative pain was assessed using the visual analogue scores (VAS) at 0hrs, 2hrs, 4hrs, weight bearing (WB) and discharge (DC). Results. There was no statistically significant difference in opiates intake amongst the three groups. When comparing VAS scores; there were no statistical difference between the groups at any of the time intervals that VAS was measured. However, the GA+LIA group hospital's LOS (m=2.31hrs, SD=0.75) was almost half that of GA+ACB group (m=4.24hrs, SD=1.08); (conditions t(72)=8.88; p=0.000). There was no statistical significance in the incidence of adverse effects amongst the groups. Conclusion. The LIA technique provided equally good pain relief following hamstring graft ACL reconstructions when compared to ACB, while allowing for earlier rehabilitation, mobilisation and discharge


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 103 - 103
1 Sep 2012
Leiter JR Elkurbo M McRae S MacDonald PB
Full Access

Purpose. The majority (73%) of orthopaedic surgeons in Canada prefer using semitendinosus-gracilis (STG) autograft for ACL reconstruction. However, there is large variation in tendon size between individuals which makes pre-operative estimation of graft size unpredictable. Inadequate graft size may require an alternative source of graft tissue that should be planned prior to surgery. The purpose of this study is to determine if clinical anthropometric data and MRI measurements of STG tendons can be used to predict hamstring graft size. Method. One-hundred and fourteen patients with ACL deficiency awaiting reconstruction using hamstring autograft were retrospectively evaluated. The following information was obtained from patient charts: height, weight, body mass index (BMI), age, and gender. Cross-sectional area (CSA) of gracilis (G) and semitendinosus (ST) tendons were determined from pre-operative MRI scans using NIH ImageJ analysis software. Actual STG graft diameters were obtained from operative reports. Correlations between patient height, weight, BMI, age, gender, ST-CSA, G-CSA, STG-CSA and intraoperative graft size were calculated to determine the association between these variables. Multiple stepwise regression was performed to assess the predictive value of these variables to intraoperative graft diameter. In addition, three investigators with no radiological experience made independent measurements of the ST and G tendons to determine the inter-rater reliability (ICC) of MRI measurements. Results. All variables were independently correlated with intraoperative graft size (p<0.001). However, based on multiple stepwise regression analysis, only models including STG-CSA (r2=.212; p<.001); STG-CSA and sex (r2=.285; p<.001); and STG-CSA, sex and weight (r2=.294; p<.001) were found to be significant predictors of graft size (when co-variation in other factors was controlled). Inter-class correlation coefficients demonstrated very high agreement between raters for measurements of the ST, G and STG (.816, .827, .863, respectively). Conclusion. Measurement of tendon CSA from MRI images is very reliable. A model including STG-CSA, sex and weight was found to be strongly predictive of hamstring graft diameter for ACL reconstruction. This model may enhance our ability to predict adequate graft size and identify instances that other graft tissues may be a better option. The results of this study may improve pre-operative planning for ACL reconstruction


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 51 - 51
1 Mar 2021
Larose G McRae S Beaudoin A McCormack R MacDonald P
Full Access

There is increasing evidence that patients with ACL reconstruction using ipsilateral graft harvest are at greater risk of rupture (12.5%) on their contralateral compared to their surgical side (7.9%). The purpose of this study is to re-evaluate patients from a previous study comparing ipsi- versus contralateral graft harvest to compare ACL rupture rate at a minimum 10 year follow-up.

An attempt to contact all participants from a previously published study was made to invite them to return for a follow-up. The assessment included an International Knee Documentation Committee Knee Clinical Assessment (IKDC), isokinetic concentric knee flexion and extension strength testing, as well as the ACL-Quality of life (ACL-QOL). A chart review was conducted to identify or confirm subsequent ipsi- or contralateral knee surgeries.

In patients with ipsilateral graft, 3/34 (8.8%) re-ruptured and 3/34 (8.8%) had contralateral rupture. In the contralateral group, 1/28 (3.6%) re-ruptured and 2/28 (7.1%) had contralateral rupture. The relative risk (RR) of re-rupture with ipsilateral graft was 2.47 compared to using the contralateral site (p=0.42). RR of rupture on the contralateral side when ipsilateral graft was used was 1.23 compared to the alternate approach. Current contact information was unavailable for 21 patients. Of the 47 remaining, 37 were consented (79%). No difference in the ACL-QOL between groups (ipsilateral 68.4±24.4, contralateral 80.1±16.0, p=0.17) was observed. There were no differences in knee flexion strength between groups (peak torque flexion affected leg: ipsilateral 77.8nm/kg±27.4, contralateral: 90.0 nm/kg±35.1; p=0.32; Unaffected leg: ipsilateral: 83.3 nm/kg±30.2 contralateral 81.7 nm/kg±24.4; p= 0.89).

This study suggests that using the contralateral hamstring in ACL rupture is not associated with an increase in ACL rupture on either side. The risk of ACL injury was low in all limbs; therefore, a larger study would be required to definitively state that graft side had no impact.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 27 - 27
1 Jul 2012
Henderson L Johnston A Stokes M Corry I Nicholas R
Full Access

Anterior cruciate ligament (ACL) reconstruction is a commonly performed operation. A variety of graft options are used with the most popular being bone-patellar-tendon-bone and hamstring autograft. There has been an increase in the popularity of hamstring autograft over the past decade.

The aim of the study was to assess the ten year subjective knee function and activity level following four-strand semitendinosis and gracilis (STG) anterior cruciate ligament reconstruction.

86 patients underwent anterior cruciate reconstruction by two knee surgeons over a 12 month period (January 1999 to December 1999). 80 patients meet the inclusion criteria of arthroscopic ACL reconstruction. The same surgical technique was used by both surgeons involving four-strand STG autograft, single femoral and tibial tunnels and aperture graft fixation with the Round headed Cannulated Interference (RCI) screw. Patient evaluation was by completion of a Lysholm Knee Score and Tegner Activity Level Scale at a minimum of ten years from reconstructive surgery. This was by initial postal questionnaire and subsequent telephone follow-up.

80 patients underwent anterior cruciate reconstruction with average age 30.9 years (15 to 58 years). There was a 77.5% (62 patients) response at ten years to the questionnaire.

The median Lysholm Knee Score at ten years was 94 (52 to 100). The median activity level had decreased from 9 to 5 at ten years according to the Tegner Activity Scale. 73% of patients reported a good or excellent outcome on the Lysholm score. The group of patients was further divided into those that required meniscal surgery and those that did not. The patients that did not require meniscal surgery had a median Lysholm score of 94 and those that required meniscal surgery had a similar median Lysholm score of 92.5. However it was noted that 8 patients required medial and lateral partial menisectomies at the time of original reconstruction. This group of patients had a median Lysholm Knee Score of 83.5 and Tegner Activity Scale of 4 at ten years following reconstruction. 17 of the 62 patients (27.4%) required re-operation because of further knee symptoms, with 4 patients requiring revision of the anterior cruciate following re-rupture.

In conclusion anterior cruciate ligament reconstruction with four-strand STG hamstring autograft provides a reliable method of restoring knee function, with a 6% revision rate for re-rupture at ten years. Combined partial medial and lateral menisectomy at the time of the initial reconstruction is a poor prognostic indicator of function at ten years.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 6 - 6
10 Feb 2023
Lawless A Ebert J Edwards P Aujla R Finsterwald M Dalgleish S Malik S Raymond R Giwnewer U Simpson A Grant M Leys T D'Alessandro P
Full Access

Hamstring grafts have been associated with reduced strength, donor site pain and muscle strains following Anterior Cruciate Ligament Reconstruction (ACLR). Traditional graft fixation methods required both semitendinosus and gracilis tendons to achieve a graft of sufficient length and diameter, but newer techniques allow for shorter, broad single tendon grafts. This study seeks to compare the outcomes between Single Tendon (ST) and Dual Tendon (DT) ACLR, given there is no prospective randomised controlled trial (RCT) in the literature comparing outcomes between these options. In this ongoing RCT: (ANZ Clinical Trials Registry ACTRN126200000927921) patients were recruited and randomised into either ST or DT groups. All anaesthetic and surgical techniques were uniform aside from graft technique and tibial fixation. 13 patients were excluded at surgery as their ST graft did not achieve a minimum 8mm diameter. 70 patients (34 ST, 36DT) have been assessed at 6 months, using PROMS including IKDC2000, Lysholm and Modified Cincinnati Knee, visual analog scale for pain frequency (VAS-F) and severity (VAS-S), dedicated donor site morbidity score, KT-1000 assessment, and isokinetic strength. Graft diameters were significantly lesser in the ST group compared to the DT group (8.44mm/9.11mm mean difference [MD],-0.67mm; P<0.001). There was a significant and moderate effect in lower donor site morbidity in the ST group compared to the DT group (effect size [ES], 0.649; P = .01). No differences between groups were observed for knee laxity in the ACLR limb (P=0.362) or any of the patient-reported outcome measures (P>0.05). Between-group differences were observed for hamstrings strength LSI favouring the ST group, though these were small-to-moderate and non-significant (ES, 0.351; P = .147). ST (versus DT) harvest results in significantly less donor site morbidity and this is the first prospective RCT to determine this. There were no differences between ST and DT hamstring ACLR were observed in PROMs, knee laxity and hamstring strength. Younger female patients tend to have inadequate single tendon size to produce a graft of sufficient diameter, and alternative techniques should be considered. Further endpoints include radiological analysis, longer term donor site morbidity, revision rates and return to sport and will continue to be presented in the future


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 4 - 4
1 Jun 2015
Akhtar M Bonner T White L Hui A
Full Access

Recurrent patellar instability is common in young and active patients. Medial patellofemoral ligament (MPFL) reconstruction with a single bundle hamstring graft is one method of surgical treatment for this problem. This is a retrospective case series of patients who underwent MPFL reconstruction by a single specialist knee surgeon between January 2009 and July 2014. Data was collected prospectively for the purpose of service evaluation. Recorded data included gender, age, length of rehabilitation, complications, Knee Injury and Outcome Score (KOOS) and International Knee Documentation Score (IKDC). Data is expressed as mean (range). 108 knees (103 patients) were identified (56 female, 52 male) with a mean age of 24.5 years (12–58). Mean length of rehabilitation was 3.2 months (0–11 months). Three patients required further revision surgery for recurrent instability. KOOS and IKDC scores improved from 44 (4–86) and 38 (2–81), respectively before surgery, to 77 (49–100) and 69 (37–95) after rehabilitation. MPFL reconstruction with a single bundle hamstring graft produces a marked improvement in knee function with a low recurrence of instability


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVII | Pages 17 - 17
1 May 2012
Hamer A Metcalfe A Roy S
Full Access

AIMS. To review the results of a single surgeon series using the above implants looking at functional outcome and implant survivorship. BACKGROUND. The outcome of ACL reconstruction is multi-factorial. There are many described ways of securing a 4-srandd hamstring ACL graft with no clear gold standard. METHODS. A prospectively collected database was used to identify patients who had undergone primary ACL reconstruction under a single surgeon. In all cases, a 4 strand hamstring graft was used and secured with Bio-Intrafix and Rigidfix implants (Depuy Mitek). Minimum follow up was 8 months. Those who met the inclusion criteria were contacted via a postal survey using the Lysholm and Tegner questionnaires. RESULTS. In total 77 patients were eligible for inclusion, (10 females, 67 males) with a mean age of 31 (range 16-56). The response rate was 77% with average follow up of 25 months (range 9-44). The mean Lysholm score was 82.1, with 59% ranking their knee as good or excellent. On average patients dropped 1.8 levels on the Tegner activity rating (means of 7.5 to 5.7). There was a 100% survivorship of implants with no revisions undertaken due to implant failure. DISCUSSION. The study has shown that this cohort of patients has self-reported outcomes analogous to findings in the literature, and no obvious problem with implants. The quadrupled hamstring graft using Bio-Intrafix and Rigidfix implants produces mid- term functional and activity levels in keeping with the literature standard


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 104 - 104
1 Feb 2012
Khan R Konyves A Rama K Thomas R Amis A
Full Access

Roentgen stereophotogrammetric analysis (RSA) is the most accurate radiographic technique for the assessment of three-dimensional micromotion in joints. RSA has been used previously to study the kinematics of the anterior cruciate ligament (ACL)-deficient knee and to measure knee laxity after bone-tendon-bone (BTB) reconstructions. There is no published evidence on its use in assessing hamstring grafts in vivo, in comparing hamstring versus BTB reconstruction, or in-depth analyses of graft performance. The aim of this project was to use RSA to measure laxity in both BTB and hamstring reconstructions, and to attempt a detailed analysis of graft behaviour in both reconstructions, with particular attention to graft stretching and slippage of the bony attachments. A prospective study was undertaken on 14 patients who underwent ACL reconstruction. Seven had BTB reconstruction, and seven had four-stranded semitendinosus/gracilis (STG). Tantalum markers were inserted at the time of surgery, into distal femur and proximal tibia, and also directly into the graft itself. Stress radiographs (90N anterior and 90N posterior force) were taken early post-operatively, and then at 6 weeks, and 3, 6 and 12 months. In addition to measuring total anteroposterior knee laxity, a detailed analysis of the graft itself was possible. The BTB grafts had stretched by an average of 1.54%, and the bone plugs had migrated by 0.50 mm at the femoral end and by 0.61mm at the tibial end. The hamstring grafts had stretched on average 3.94%, and the intraosseous ends had migrated by 3.96mm at the femoral end and by 7.10mm at the tibial end. This is believed to be the most detailed application of RSA in analysing the performance of the two commonly used grafts in ACL reconstruction. Details such as graft stretching and fixation slippage have not been available previously; the data obtained in this study may have implications for clinical practice


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 4 - 4
1 Nov 2019
Aujla RS Hansom D Rooney A Wheelton A Wilding C Barwell J Spacey K McMullan M Shaw C Hashim Z Akhtar MA Godsiff S
Full Access

Knee dislocations are a rare but serious cause of trauma. The aim of this study was to establish current demographics and injury patterns/associations in multi-ligament (MLI) knee injuries in the United Kingdom. A National survey was sent out to trauma & orthopaedic trainees using the British Orthopaedic Trainees Association sources in 2018. Contributors were asked to retrospectively collect a data for a minimum of 5 cases of knee dislocation, or multi-ligament knee injury, between January 2014 and December 2016. Data was collected regarding injury patterns and surgical reconstructions. 73 cases were available for analysis across 11 acute care NHS Trusts. 77% were male. Mean age was 31.9 (SD 12.4; range 16–69). Mean Body Mass Index (BMI) was 28.3 (SD 7.0; range 19–52). Early (<3 weeks) reconstruction was performed in 53% with 9 (23%) patients under-going procedures for arthrofibrosis. Late (>12 weeks) reconstruction took place in 37% with one (3.7%) patient under-going arthroscopic arthrolysis. 4% had delayed surgery (3–12 weeks) and 5% had early intervention with delayed ACL reconstruction. For injuries involving 3 or more ligament injuries graft choices were ipsilateral hamstring (38%), bone-patella tendon-bone (20%), allograft (20%), contralateral hamstring (17%) and synthetic grafts in 18%. Multi-ligament knee injuries are increasingly being managed early with definitive reconstructions. This is despite significant risk of arthrofibrosis with early surgery. Ipsilateral and contralateral hamstring grafts make up the bulk of graft choice however allograft (20%) and synthetic grafts (18%) remain popular


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 19 - 19
1 Nov 2019
Vijayan S Kulkarni MS Shetty S Naik AM Rao SK
Full Access

Anterior cruciate ligament (ACL) injuries are one of the most common ligament injury occurring in young and active individuals. Reconstruction of the torn ligament is the current standard of care. Of the many factors which determine the surgical outcome, fixation of the graft in the bony tunnels has significant role. This study compared the clinical and functional outcome in patients who underwent ACL reconstruction by standard anteromedial portal technique with single bundle hamstring graft anchored in the femoral tunnel using rigidfix and cortical button with adjustable loops. The tibial fixation and rehabilitation protocol were same in both groups. 107 patients underwent ACL reconstruction over a two-year period (87 males, 20 females, 44 after motor vehicle accident, 34 after sports injuries, 79 isolated ACL tear, 21 associated medial meniscus tear, 16 lateral meniscus tear and 11 both menisci). Rigid fix group had 47 patients and adjustable loop 60 patients. Clinical evaluation at end of one year showed better stability in rigid fix group regarding Lachman, anterior drawer, pivot shift tests, KT 1000 arthrometer side to side difference and hop limb symmetry index. However, the differences were not statistically significant. Functional evaluation using IKDC 2000 subjective score and Lysholm score showed better results in rigidfix group than variable loop, but was not statistically significant. However, lower scores were noted in patients with concomitant meniscal injury than in isolated acl tear patients and this was statistically significant in both groups. Rigidfix seems to give better graft fixation on femoral side than variable loop, but by the end of one year the functional outcome is comparable in isolated acl reconstructions


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 31 - 31
1 Oct 2015
Sabat D
Full Access

The purpose of this study was to evaluate the results of selective anatomic augmentation of partial anterior cruciate (ACL) ligament tears in 36 consecutive patients with mean 3years follow-up. Our hypothesis is that this selective augmentation of partial ACL tears could restore knee stability and function. In a consecutive series of 314 ACL reconstructions, 40 patients in which intact ACL fibers remained in the location corresponding to the anteromedial or posterolateral bundle were diagnosed perioperatively. All patients underwent selective augmentation of the torn bundle, while keeping the remaining fibers intact using autogenous hamstring graft. 38 patients (28 males, 10 females) were available with minimum 3 year follow- up. 26 cases had AM bundle tears and 12 cases had PL bundle tears respectively. Patients were assessed with International Knee Documentation Committee (IKDC) 2000 Knee Evaluation Form, Lysholm score; instrumented knee testing was performed with the arthrometer (KT 2000). Statistical analysis was performed to compare the preoperative and postoperative objective evaluation. At 3 year follow-up, 12 (31.6%) patients were graded A, 25 (65.8%) graded B and 1 C (2.6%) at IKDC objective evaluation. Lysholm's score and mean side to side instrumental laxity improved significantly. The results of anatomic single bundle augmentation in partial ACL tears are encouraging with excellent side to side laxity


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 23 - 23
1 Dec 2015
Kursumovic K Charalambous C
Full Access

No consensus exists regarding the optimal graft choice between allogenic and autologous graft. Incidence of septic arthritis following ACL reconstruction is rare but may dependent on the graft type. Our meta-analysis assesses the difference in incidence of septic arthritis after ACL reconstruction across three groups of grafts: hamstring autografts, bone patellar tendon bone (BPTB) autografts and allografts of any type. A literature search was performed without language restriction on PubMed and EMBASE databases. We identified 245 infected ACL grafts across 15 included studies that provided a breakdown of infection incidence by graft type. A meta-analysis was performed using a random-effects model to estimate the overall infection rates and those for different graft types. Summary risk ratios and 95% confidence intervals (CIs) were calculated and reported for each outcome. Publication bias with respect to infection rates was estimated using a funnel plot. Our meta-analysis shows an overall ACL graft infection rate of 0.6% (CI 0.3% – 1.3%). The incidence was highest in autologous hamstring grafts at 1.1% at (CI 0.8% – 1.6%). That of allografts and autologous BPTB grafts was similar at 0.5% (CI 0.2%–1.0%) and 0.4% (CI 0.2% – 0.7%), respectively. Full breakdown of the meta-analysis results by study and graft type is reported in Figure 1. Septic arthritis after ACL reconstruction remains a rare (<1%) but a serious complication. Allograft rates of infection were not higher than those the autografts, contrary to the theoretical concerns. Therefore a higher infection risk should not be cited as a reason for not using it. The reason for the apparently higher infection rate with hamstring autografts is unclear and requires further research. The results of our meta-analysis may aid informed discussions between surgeons and patients about the risk of infection after ACL reconstructive surgery and graft choice


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 102 - 102
1 Feb 2012
Spalding T McGee A Gallie P Dalton P Siddiqui A
Full Access

The aim of this paper is to evaluate the Linvatec SE graft tensioner system in obtaining predictable initial tension during ACL reconstruction using hamstring grafts. The gracilis and semitendinosus grafts were tensioned individually prior to fixation distally to a combined tension of 80N. The knees were then cycled through full range of motion and the tension recorded at 90 degrees and in full flexion and extension. Experience on the first 22 patients indicated that 41% required 10 cycles of the knee to remove pre-conditioning and equalise tension at 80N combined, while the remaining 50% required 15 cycles. 90% reached stable tension after 15 cycles. In 54% the tension increased at full extension and graft tension was adjusted to 80N in extension to avoid overconstraining the graft. Twenty-two patients studied following this initial protocol underwent outcome assessment after minimum 6 months. Mean KT1000 arthrometry manual maximum side to side difference was 1.5mm. Femoral fixation was achieved using the Endobutton (Smith and Nephew) and Tibial fixation using the Extralok bioabsorbable screw (Linvatec). A subsequent shortened protocol of initial over-tensioning to 60N and 40N for the semitendinosus and gracilis double bundles respectively, followed by 15 cycles of the knee resulted in stable 80N combined tension with no further drop with more cycling. We conclude that the new tensioner system allows for accurate and predictable initial tension of hamstring reconstructed ACL grafts and that its use can be simplified by using the second technique protocol


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 15 - 15
1 Oct 2012
Sasaki S Daher S Hernandez A Albuquerque R Resende M Queiroz R Moscovich H
Full Access

The purpose of the study was to compare prospectively and randomly two ACL reconstruction single bundle techniques, one referred to as traditional and the other referred to as anatomical, where the coronal angulation of the femoral tunnel aimed a more horizontal position at 2 and 10 o'clock. Orthopilot® System (Aesculap, Tuttlingen, Germany) was used to assist tunnel positioning in order to obtain and register translational and rotational stability. Eighteen patients (14 men and 4 women), average age 33.8 years (range 18 to 49), with isolated ACL lesion were randomized in two groups, A (Conventional) and B (Anatomical). All patients were submitted to ACL navigated arthroscopic reconstruction with quadruple hamstrings grafts. Anteromedial portal access for femoral tunnel drilling was used in all patients. The tibial and femoral tunnels drillings were monitored by the Aesculap® Orthopilot Navigation System. In Group A, the femoral tunnel positioning aimed isometricity. In Group B, femoral tunnel was drilled at 25% of Blumensaat's line length from the posterior cortex, and 30° orientation in coronal plane. Initial and final Maximum Anterior tibial Displacement (MATD), Internal Tibial Rotation (ITR) and External Tibial Rotation (ETR) at 30° knee flexion data were recorded intra operatively by the navigation system. No horizontal or rotational stability differences were found for MATD (p = 0.68), ITR (p = 014) and ETR (0.13). This study did not support the hypothesis that a more anatomical positioning leads to better rotational or anterior stability


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 105 - 105
1 Sep 2012
Pinczewski L Gordon D Sri-Ram K Kok A Linklater J Salmon L
Full Access

Bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been shown to be associated with femoral tunnel widening and cyst formation. To compare a poly-L-lactide–hydroxyapatite screw (PLLA-HA) with a titanium screw with respect to clinical and radiological outcomes over a 5 year period. 40 patients were equally randomized into 2 groups (PLLA-HA vs titanium) and ACLR performed with a 4 strand hamstring graft with femoral tunnel drilling via the anteromedial portal. Evaluation at 2 and 5 years was performed using the International Knee Documentation Committee assessment (IKDC), Lysholm knee score, KT 1000 arthrometer, single-legged hop test. Magnetic resonance imaging was used to evaluate tunnel and screw volume, ossification around the screws, graft integration and cyst formation. There was no difference in any clinical outcome measure at 2 or 5 years between the 2 groups. At 2 years, the PLLA-HA femoral tunnel was significantly smaller than the titanium screw tunnel (p=0.015) and at 5 years, there was no difference. At 2 years the femoral PLLA-HA screw was a mean 76% of its original volume and by 5 years, 36%. At 2 years the tibial PLLA-HA screw mean volume was 68% of its original volume and by 5 years, 46%. At 5 years, 88% of femoral tunnels and 56% of tibial tunnels demonstrated a significant ossification response. There was no increase in cyst formation in the PLLA-HA group and no screw breakages. The PLLA-HA screw provides adequate aperture fixation in ACLR with excellent functional outcomes. It was not associated with femoral tunnel widening or increased cyst formation when compared with the titanium screw. The resorbtion characteristics appear favourable and the hydroxyapatite component of the screw may stimulate osteoconduction, contributing to these results. The PLLA-HA screw is a good alternative to a titanium screw in ACLR, which may aid revision procedures and allow for imaging without artifact


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 14 - 14
1 Jul 2012
Hamer A Roy S Metcalfe A
Full Access

The use of a quadrupled hamstring graft in ACL reconstruction is well established. There are many described techniques in securing graft fixation, the optimal method is not yet established. The aim of this study was to review the results of a single surgeon series using the above implants looking at functional outcome for the patient and implant survivorship. Patients were recruited for the study who had completed 8 months of post-op rehabilitation following primary ACL reconstruction and that had received the same surgical technique using the same implants from one surgical team. Patients undergoing a revision procedure were excluded. All patients received the same post-operative rehabilitation. Those who met the inclusion criteria were contacted via a postal survey using the Lysholm and Tegner questionnaires. In total 77 patients were eligible for inclusion, consisting of 10 females and 67 males with a mean age of 31 (range 16-56). A 77% survey return rate was achieved with average follow up of 25 months (range 9-44). The mean Lysholm score was 82.1, with 59% ranking their knee as good or excellent. On average patients dropped 1.8 levels on the Tegner activity rating from a pre-injury average of 7.5 to post rehabilitation average of 5.7. There was a 100% survivorship of implants with no revisions undertaken due to implant failure. The study has shown that this cohort of patients has produced self reported outcomes analogous to findings in the current literature. No obvious problem with implants was observed. It has highlighted the multiple factors associated with the outcome of ACL reconstruction and demonstrates that the quadrupled HT graft using Bio-Intrafix and Rigidfix implants produces short to mid-term functional and activity levels in keeping with the literature standard


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 181 - 181
1 May 2012
Sasahara J Takeda H Matsushita T Kurata T Koguchi A Oguro K Samejima Y Watarai K
Full Access

Tibial and femoral bone tunnel widening (TW) has been observed following anterior cruciate ligament (ACL) reconstruction. We developed a χ12 mm cannulated cancellous screw (Intercondylar Ligament Screw, ICLS) for femoral fixation to reduce TW. The purpose of this study is to introduce our surgical method and its results. We employed an original ICLS system developed to reduce the needed distance between the tibial and femoral-fixation points (distance between fixation points, DbF) in ACL reconstruction. Five-strand (sometimes four or six-strand) hamstring grafts are connected to the ICLS. Tibial fixation is achieved with a Ligament Tension Screw, which had been developed by Murase et al. rom 2001 to 2008, 169 knees underwent ACL reconstruction at our hospitals using our ICLS system. TW was evaluated by radiographs at least three months postoperatively. An enlargement of more than 2 mm was considered TW. The following was also evaluated: range of motion, the limb symmetry index (LSI, injured leg divided by uninjured and multiplied by 100), value of knee extension power in OKC, anterior knee laxity, Lysholm score, and DbF. The average length of DbF was 38.1 mm (n=132). Only 6.7% (n=104) of cases showed more than 2 mm of TW. Mean LSI was 83.3%(n=77) four months postoperatively. The mean Lysholm score was 96.2(n=68) at three months after ACL reconstruction. The mean side-to-side difference in anterior tibial translation, measured with use of a KT-2000 or Knee Lax, was 1.60 mmï1/4N=57ï1/4‰. We were able to reduce TW after ACL reconstruction using our ICLS system with good results


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 9 - 9
1 Apr 2013
Pankaj A Sharma G
Full Access

Introduction. Transportal technique of femoral drilling allows the femoral tunnel to be placed in anatomic location. The study was conducted to evaluate the orientation of ACL graft performed by two different techniques and compared to orientation of native ACL. Materials/Methods. 50 patients (Group A) underwent ACL reconstruction with transtibial technique using transfix on the femoral side and 30 patients (Group B) underwent ACL reconstruction with transportal technique using endobutton. We used quadrupled hamstrings graft and tibial fixation was achieved with bio-absorbable screws. All patients were evaluated with 3 Tesla MRI at 6 months post-operatively and femoral tunnel angle in coronal plane (FTA), tibial tunnel angle (TTA) in sagittal plane, graft angle in coronal plane (GA coronal), graft angle in sagittal plane (GA sagittal), and graft- Blumensaat line angle (GBLA) were measured. A control group of patients (Group C, n=50)was also included to evaluate the orientation of native ACL. Results. The femoral tunnel angle (FTA) was significantly lower in group B as compared to group A, 54.03±5.05 vs 71.6±6.02, p<0.05. The tibial tunnel angle (TTA) was similar in group A and B, 65±5.2 vs. 62.9±4.5, p>0.05. Graft angle in coronal plane (GA coronal) was significantly lower in group B when compared to group A, 62.4±5.6 vs 72.5±5.5, p<0.05, and there was no significant difference between group B and C. Similarly graft angle in sagittal plane (GA sagittal) in group B was found to be significantly lower as compared to group A and similar to group C, 51.2±4.3 vs 65.3±3.6, p<0.05. The graft-Blumensaat line angle (GBLA) was significantly lower in group B as compared to Group A, 8.6±1.4 vs 13.5±1.2, p<0.05. Conclusions. The orientation of the reconstructed ligament was found to be closer to the native ACL in transportal technique of femoral drilling


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 120 - 120
1 Sep 2012
Roe J Sri-Ram K Salmon L Pinczewski L
Full Access

To determine the relationship between advancing months from ACL rupture and the incidence of intra-articular meniscal and chondral damage. From a prospectively collected database 5086 patients undergoing primary ACL reconstruction, using hamstring graft, carried out between January 2000 and August 2010 were identified. Data collected included the interval between injury and surgery, type and location of meniscal tears (requiring meniscectomy) and location and severity of chondral damage (ICRS grading system). Patients were grouped according to time interval and age. The median time from ACL injury to ACL reconstruction was 3 months (range 0.25 to 480). Overall, an increasing incidence of medial meniscal injury and chondral damage occurred with advancing chronicity of ACL deficiency. The incidence of medial meniscal injury requiring meniscectomy increased from 18% of patients undergoing ACL reconstruction within 4 months of injury to 59% of patients if ACL reconstruction was delayed more than 12 months (p<0.001). The incidence of lateral meniscal tears did not increase significantly over time. The increasing incidence of secondary pathology with advancing chronicity was more pronounced in the younger age groups. The risk of a medial meniscal tear requiring resection was significantly less if surgery was performed before 5 months in the <17 years group (Odds Ratio 2) and 17–30 years group (OR 1.9), but less so in the 31–50 years group (OR 1.5) and >50 years group (OR 1.5). Advancing age was associated with a greater incidence of chondral damage and medial meniscal injury, but not lateral meniscal injury. Males had a greater incidence of lateral meniscal tears (34% vs. 20%), but not medial (28% vs. 25%) or chondral damage (35% vs. 36%), compared to females. The incidence of chondral damage and medial meniscal tears increases with advancing time after ACL injury. Particularly in younger patients, ACL reconstruction should be performed within 4 months of ACL injury in order to minimise the risk of irreversible damage to meniscal and chondral structures