Advertisement for orthosearch.org.uk
Results 1 - 20 of 87
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 13 - 13
1 Apr 2018
Knowles N Langohr G Athwal G Ferreira L
Full Access

BACKGROUND. Stability of the glenoid component is essential to ensure successful long-term outcomes following Total shoulder arthroplasty (TSA), and may be improved through better glenoid component design. As such, this study assessed identical all-polyethylene glenoid components stability, having various fixation types, using component micromotion under simulated joint loading in an osteoarthritic patient cohort. METHODS. Five all-polyethylene glenoid component designs were compared (Keel, Central-Finned 4-Peg, Peripheral 4-Peg, Cross-Keel, and Inverted-Y). A cement mantle surrounded each fixation type, except the Central-Finned 4-Peg which was surrounded by bone. The humeral component had a non-conforming radius of curvature. Scapular models of six type A1 osteoarthritic male patients (mean: 61 years old, range: 48 to 76 years old) were assigned heterogeneous bone properties based on CT intensity. Each of the 30 scapula models were truncated and fully constrained on the medial scapular border. The bone/cement interface was fully bonded, and the fixation feature/cement interface was frictionally constrained. A ‘worst case’ load magnitude of 125% BW of a 50th percentile male was used. A purely compressive load was applied to the center of the glenoid component, followed by superior, superior-posterior, posterior, inferior-posterior, and inferior loads. Stability of the glenoid component based solely on the fixation type was determined using the mean and maximum normal (liftoff) and tangential (sliding) micromotion in six regions of the glenoid component. RESULTS. The greatest mean normal micromotion occurred for the Inverted-Y (90 ± 36 μm) in the anterior- inferior region of the component under a posterior-superior directed load. The mean normal micromotions were significantly less for the same region and loading direction in the Peripheral 4-peg (48 ± 16 μm; p < .001) and Central-Finned 4-Peg (35 ± 13 μm; p < .001), but not significantly different for the Keel (78 ± 37 μm; p = .029), or Cross-Keel (82 ± 32 μm; p = .143). The same region and loading direction produced the maximum normal micromotion in the Inverted-Y (109 ± 43 μm), which was significantly greater than the other four components (Peripheral 4-peg, 61 ± 25 μm; p < .001, Keel, 89 ± 36 μm; p < .001, Central-Finned 4-Peg, 47 ± 19 μm; p < .001, and Cross-Keel, 92 ± 37 μm; p = .002). The greatest mean tangential micromotion occurred for the Cross-Keel (100 ± 36 μm) in the posterior-superior region of the glenoid component under a posterior-superior directed load. The mean tangential micromotions for all other components were significantly less (p < .001) for the same region and loading direction (Peripheral 4-peg, 73 ± 19 μm, Keel, 73 ± 22 μm, Central-Finned 4-Peg, 73 ± 26 μm, and Inverted-Y, 83 ± 24 μm). The same region and loading direction for the maximum tangential micromotion was also in the Cross-Keel (146 ± 46 μm), which was significantly greater (p < .001) from the other four components (Peripheral 4-peg, 111 ± 21 μm, Keel, 115 ± 34 μm, Central-Finned 4-Peg, 111 ± 39 μm, and Inverted-Y, 117 ± 34 μm). DISCUSSION. This study addressed the contribution of all-polyethylene glenoid component fixation types on component stability under simulated joint loading. Pegged components were significantly more stable than keeled components. An inverse relationship between normal and tangential micromotion was observed, with the greatest sliding (tangential micromotion) occurring in the direction of the applied load, and the greatest liftoff (normal micromotion) occurring opposite the applied load. This likely occurs due to polyethylene deformation of both the fixation features and the component as a whole


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 21 - 21
1 Nov 2015
Romeo A
Full Access

Total shoulder arthroplasty (TSA) is an excellent surgical solution for patients with shoulder arthritis, providing good to excellent results in the vast majority of patients. Complications are rare, however, when they occur, can be devastating for both the patient and surgeon. An increasingly recognised complication of TSA is glenoid component failure. In a recent review of nearly 4000 shoulder arthroplasties, symptomatic glenoid component loosening occurs at a rate of 1.2% per year, while asymptomatic radiolucent lines occur at a rate of 7.3% per year. In addition, keeled glenoid components have been found to have an increased incidence of radiolucent lines compared to pegged glenoid components at both short and longer-term follow-up. Further, pegged glenoid components are associated with a lower risk of revision arthroplasty compared to keeled glenoid components. In a separate study of approximately 4600 shoulder arthroplasties, metal-backed glenoid components were found to have significantly lower rates of radiolucent lines, radiographic loosening, and component failure compared to all-polyethylene glenoid components. Despite these findings, however, metal-backed components are significantly more likely to require revision surgery (3:1) compared to all-polyethylene components. For the failed TSA due to glenoid component failure, revision with glenoid reimplantation may be considered, but is associated with a high rate of recurrent glenoid loosening. Alternatively, revision to a reverse shoulder arthroplasty, is feasible, but is technically demanding with high complication and reoperation rates. This paper will discuss the etiology, work-up, and treatment of patients with glenoid component failure following TSA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 83 - 83
1 May 2016
Karelse A Van Tongel A Verstraeten T Poncet D De Wilde L
Full Access

BACKGROUND. Abnormal glenoid version positioning has been recognized as a cause of glenoid component failure caused by the rocking horse phenomenon. In contrast, the importance of the glenoid inclination has not been investigated. MATERIALS AND METHODS. The computed tomography scans of 152 healthy shoulders were evaluated. A virtual glenoid component was positioned in 2 different planes: the maximum circular plane (MCP) and the inferior circle plane (ICP). The MCP was defined by the best fitting circle of the most superior point of the glenoid and 2 points at the lower glenoid rim. The ICP was defined by the best fitting circle on the rim of the inferior quadrants. The inclination of both planes was measured as the intersection with the scapular plane. We defined the force vector of the rotator force couple and calculated the magnitude of the shear force vector on a virtual glenoid component in both planes during glenohumeral abduction. RESULTS. The inclination of the component positioned in the MCP averaged 95° (range, 84°–108°) and for the ICP averaged 111° (range, 94°–126°). A significant reduction in shear forces was calculated for the glenoid component in the ICP vs the MCP: 98% reduction in 60° of abduction to 49% reduction in 90° of abduction. CONCLUSION. Shear forces are significantly higher when the glenoid component is positioned in the MCP compared with the ICP, and this is more pronounced in early abduction. Positioning the glenoid component in the inferior circle might reduce the risk of a rocking horse phenomenon. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 8 - 8
1 Jul 2014
Flatow E
Full Access

The incidence of total shoulder arthroplasty continues to increase. The most common reason for failure of a total shoulder arthroplasty is the glenoid component. Two styles of cemented all-polyethylene components are commonly implanted. These two styles are pegged glenoid and keel glenoid components. Data regarding the superiority of the styles has focused on radiolucent lines, complete loosening and need for revision procedures. Several retrospective and randomised controlled trials have been published to examine these endpoints. There is a trend in the literature to demonstrate decreased rates of radiolucent lines with pegged glenoid components, but a recent systematic review of available trials did not demonstrate a significant difference in the rate of radiolucent lines between the two styles. A slightly increased rate of revision was noted for the keel components. Overall pegged and keel glenoids both still represent good options in total shoulder arthroplasty


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 70 - 70
1 Apr 2018
Kim S Chae S Kang J
Full Access

Background. Use of a baseplate with a smaller diameter in reverse shoulder arthroplasty has been recommended, especially in patients with a small glenoid or insufficient bony stock due to severe glenoid wear. However, effect of a smaller baseplate on stability of the glenoid component has not been evaluated. The purpose of this study was to determine whether a smaller baseplate (25 mm) is beneficial to the initial primary stability of the glenoid component compared to that with a baseplate of a commonly used size (29 mm) by finite element analysis. Methods. Computed tomography (CT) scans of fourteen scapulae were acquired from cadavers with no apparent deformity or degenerative change. Glenoid diameter corresponding to the diameter of the inferior circle of glenoid was measured using a caliper and classified into the small and large glenoid groups based on 25mm diameter. CT slices were used to construct 3-dimensional models with Mimics (Materialise, Leuven, Belgium). A corresponding 3D Tornier Aequalis® Reversed Shoulder prosthesis model was generated by laser scanning (Rexcan 3D Laser Scanner, Solutionix, Seoul, Korea). Glenoid components with 25mm and 28mm diameter of the baseplate were implanted into the scapular of small and large glenoid group, respectively. Finite element models were constructed using Hypermesh 11.0 (Altair Engineering, Troy, MI, USA) and a reverse engineering program (Rapidform 3D Systems, Inc., Rock Hill, SC, USA). Abaqus 6.10 (Dassault Systemes, Waltham, MA) was used to simulate 30. o. , 60. o. , and 90. o. glenohumeral abduction in the scapular plane. Single axial loads of 686N (1 BW) at angles of 30. o. , 60. o. , and 90. o. abduction were applied to the center of the glenosphere parallel to the long axis of the humeral stem. Relative micromotion at the middle and inferior thirds bone–glenoid component interface, and distribution of bone stress under the glenoid component and around the screws were analyzed. Wilcoxon's rank-sum test was used for statistical comparison and p < 0.05 was considered as a minimum level of statistical significance. Results. In small glenoid group, micromotion at the middle and inferior thirds of the glenoid-glenosphere interface at angles of 30. o. and 60. o. abduction were significantly greater in the 29mm baseplate than in the 25mm baseplate. There was no significant difference in micromotion at angle of 90. o. abduction between 25mm and 29mm baseplate. In large glenoid group, there was no statistically significant difference in micromotion between 25mm and 29mm baseplate at all angles of abduction. In small glenoid group, maximum bone stress was measured at the point of cortical engagement of the inferior screw and was statistically greater in the 29mm baseplate than in the 25mm baseplate. In large glenoid group, there was no statistically significant difference of maximum bone stress around the inferior screw between 25mm and 29mm baseplates. Conclusions. Use of a baseplate with a smaller diameter (25 mm) in reverse shoulder arthroplasty is suitable for improving the primary stability of the glenoid component, especially in small glenoid


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 82 - 82
23 Feb 2023
Rossignol SL Boekel P Rikard-Bell M Grant A Brandon B Doma K O'Callaghan W Wilkinson M Morse L
Full Access

Glenoid baseplate positioning for reverse total shoulder replacements (rTSR) is key for stability and longevity. 3D planning and image-derived instrumentation (IDI) are techniques for improving implant placement accuracy. This is a single-blinded randomised controlled trial comparing 3D planning with IDI jigs versus 3D planning with conventional instrumentation. Eligible patients were enrolled and had 3D pre-operative planning. They were randomised to either IDI or conventional instrumentation; then underwent their rTSR. 6 weeks post operatively, a CT scan was performed and blinded assessors measured the accuracy of glenoid baseplate position relative to the pre-operative plan. 47 patients were included: 24 with IDI and 23 with conventional instrumentation. The IDI group were more likely to have a guidewire placement within 2mm of the preoperative plan in the superior/inferior plane when compared to the conventional group (p=0.01). The IDI group had a smaller degree of error when the native glenoid retroversion was >10° (p=0.047) when compared to the conventional group. All other parameters (inclination, anterior/posterior plane, glenoids with retroversion <10°) showed no significant difference between the two groups. Both IDI and conventional methods for rTSA placement are very accurate. However, IDI is more accurate for complex glenoid morphology and placement in the superior-inferior plane. Clinically, these two parameters are important and may prevent long term complications of scapular notching or glenoid baseplate loosening. Image-derived instrumentation (IDI) is significantly more accurate in glenoid component placement in the superior/inferior plane compared to conventional instrumentation when using 3D pre-operative planning. Additionally, in complex glenoid morphologies where the native retroversion is >10°, IDI has improved accuracy in glenoid placement compared to conventional instrumentation. IDI is an accurate method for glenoid guidewire and component placement in rTSA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 53 - 53
1 Aug 2013
Mulder M Boeyens M Honiball R
Full Access

Purpose of study:. Reverse shoulder arthroplasty is effective in the management of symptomatic arthritic shoulders with a non-reconstructable rotator cuff. Optimal orientation and initial fixation of the glenoid component is correlated with improved outcomes. This may be difficult to achieve with distorted glenoid morphology. The authors present a previously undescribed system for accurate, consistent and reliable screw placement for fixation of the glenoid component with the desired version during reverse shoulder arthroplasty. Description of methods:. The pre-operative CT scan images are used to construct a scapula model (Medical Image Processing software, CustomMed Orthopaedics)allowing the surgeon to determine the optimal position for screw placement based on available bone stock. A custom drill guide is made from polyamide, which is sterilized in an autoclave and fitted to the glenoid intra-operatively prior to reaming. The system minimizes the likelihood of malposition of glenoid components and is compatible with all arthroplasty systems. Summary of results:. The technique has been performed on 5 patients after informed consent. Post-operative CT images demonstrate intended component version and screw position in all cases. Patients are being recruited for a multicenter prospective trial. Conclusion:. The authors present a new technique for achieving optimal screw position in fixation of glenoid components. A prospective trial is underway which aims to prove through post-operative imaging that intended glenoid version and screw placement was achieved and show improved long term results


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 125 - 125
1 Sep 2012
Templeton-Ward O Griffiths D Higgs D Falworth M Bayley I Lambert S
Full Access

Reverse polarity total shoulder arthroplasty (RTSA) has gained popularity over recent years for the treatment of the painful cuff deficient shoulder. Although proposed over 20 years ago and despite good clinical outcomes the RTSA has struggled to gain popularity due to reported high levels of complications. One such complication is post-operative instability with frequencies of up to 30% (De Wilde 2002). The Bayley-Walker RTSA was designed specifically for patients with difficult reconstruction problems in whom an unconstrained prosthesis would not offer sufficient stability. It is a reverse anatomy fixed fulcrum constrained prosthesis. The glenoid component has a long HA-coated tapered helical screw, with large pitch and depth, fixation is augmented by a grooved HA coated glenoid plate. The purpose of this study was to review the clinical experience from The Royal National Orthopaedic Hospital Stanmore and to ascertain the rate of glenoid component loosening. We also carried out a radiographic review to correlate loosening with patterns of lucency on post-operative radiographs. One hundred and five B-W TSRs in 103 patients were included, 24% of which were performed as revision of previous failed arthroplasty. In total, 8/105 glenoids required revision. Of those eight patients, two were cases of septic loosening. Of all nine specified areas of glenoid, tip lucency on x-ray appeared to be most strongly associated with need for glenoid revision. 5/9 cases with tip lucency progressed to loosening of the glenoid. Where tip lucency was not seen, 93/96 glenoid components remained secure, giving tip lucency a negative predictive value of 97%. Excluding the two infected cases, the glenoid remained secure in 97/103 patients undergoing BW-TSR with follow-up up to 13 years. The BW-TSR is a satisfactory and durable solution to the cuff-deficient shoulder in variety of challenging groups including younger patients and as a salvage procedure following failed, cuff-deficient arthroplasty


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 13 - 13
1 Sep 2012
Glennie RA Giles JW Athwal GS Johnson JA Faber KJ
Full Access

Purpose. Glenoid component loosening is a common reason for failed total shoulder arthroplasty. Multiple factors have been suggested as causes for component loosening that may be related to cement technique. The purpose of the study was to compare the load transfer across a polyethylene glenoid bone construct with two different cementing techniques. Method. Eight cadaveric specimens underwent polyethylene glenoid component implantation. Four had cement around the pegs only (CPEG) and four had cement across the entire back (CBACK) of the implant including around the pegs. Step loading was performed with a pneumatic actuator and a non-conforming humeral head construct capable of applying loads at various angles. Strain gauges were placed at the superior and inferior poles of the glenoid and position trackers were applied to the superior and inferior aspects polyethylene component. Micro CT data were obtained before and after the loading protocol. Results. During compressive loading, greater tension was recorded with the CBACK technique than with the CPEG technique. Compression was recorded superiorly when load was applied at 30 degrees while tension was recorded inferiorly. Greater displacement occurred with the CPEG group. Failure as defined on micro CT occurred more consistently with the CBACK technique than with the CPEG technique. Conclusion. Tension measurements and upward deflection of the polyethylene with compressive loading at lower angles was unexpected. Early failure of fully cemented glenoids may be due to the fragility of the cement mantle around the periphery of the implant. Tension at the bone cement interface and early cement fracture are unfavorable and this may be a mechanism of implant loosening


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 126 - 126
1 Sep 2012
Gheiti AC Molony D Kennedy J Schepens A Mullett H
Full Access

Background

Reverse Geometry shoulder replacement requires fixation of a base plate (called a metaglene) to the glenoid to which a convex glenosphere is attached. Most systems use screws to achieve this fixation. The suprascapular nerve passes close to the glenoid and is known to be at risk of injury when devices and sutures are inserted into the glenoid. We investigate the risk posed to the suprascapular nerve by placement of metaglene fixation screws.

Materials and Methods

Ten cadaveric shoulder specimens were used. A metaglene was inserted and fixed using 4 screws. The suprascapular nerve was dissected and its branches identified. The screw tips and their proximity to the nerve and branches were identified and recorded.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 21 - 21
23 Feb 2023
Sandow M Page R Hatton A Peng Y
Full Access

The 2021 Australian Orthopaedic Association National Joint Replacement Registry report indicated that total shoulder replacement using both mid head (TMH) length humeral components and reverse arthroplasty (RTSA) had a lower revision rate than stemmed humeral components in anatomical total shoulder arthroplasty (aTSA) - for all prosthesis types and diagnoses. The aim of this study was to assess the impact of component variables in the various primary total arthroplasty alternatives for osteoarthritis in the shoulder. Data from a large national arthroplasty registry were analysed for the period April 2004 to December 2020. The study population included all primary aTSA, RTSA, and TMH shoulder arthroplasty procedures undertaken for osteoarthritis (OA) using either cross-linked polyethylene (XLPE) or non-cross-linked polyethylene (non XLPE). Due to the previously documented and reported higher revision rate compared to other anatomical total shoulder replacement options, those using a cementless metal backed glenoid components were excluded. The rate of revision was determined by Kaplan-Meir estimates, with comparisons by Cox proportional hazard models. Reasons for revision were also assessed. For a primary diagnosis of OA, aTSA with a cemented XLPE glenoid component had the lowest revision rate with a 12-year cumulative revision rate of 4.7%, compared to aTSA with cemented non-XLPE glenoid component of 8.7%, and RTSA of 6.8%. The revision rate for TMH was lower than aTSA with cemented non-XLPE, but was similar to the other implants at the same length of follow-up. The reason for revision for cemented aTSR was most commonly component loosening, not rotator cuff deficiency. Long stem humeral components matched with XLPE in aTSA achieve a lower revision rate compared to shorter stems, long stems with conventional polyethylene, and RTSA when used to treat shoulder OA. In all these cohorts, loosening, not rotator cuff failure was the most common diagnosis for revision


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 103 - 103
23 Feb 2023
Gupta V Van Niekerk M Hirner M
Full Access

Scapular notching is a common problem following reverse shoulder arthroplasty (RSA). This is due to impingement between the humeral polyethylene cup and scapular neck in adduction and external rotation. Various glenoid component strategies have been described to combat scapular notching and enhance impingement-free range of motion (ROM). There is limited data available detailing optimal glenosphere position in RSA with an onlay configuration. The purpose of this study was to determine which glenosphere configurations would maximise impingement free ROM using an onlay RSA prosthesis. A three-dimensional (3D) computed tomography (CT) scan of a shoulder with Walch A1, Favard E0 glenoid morphology was segmented using validated software. An onlay RSA prosthesis was implanted and a computer model simulated external rotation and adduction motion of the virtual RSA prosthesis. Four glenosphere parameters were tested; diameter (36mm, 41mm), lateralization (0mm, 3mm, 6mm), inferior tilt (neutral, 5 degrees, 10 degrees), and inferior eccentric positioning (0.5mm, 1.5mm. 2.5mm, 3.5mm, 4.5mm). Eighty-four combinations were simulated. For each simulation, the humeral neck-shaft angle was 147 degrees and retroversion was 30 degrees. The largest increase in impingement-free range of motion resulted from increasing inferior eccentric positioning, gaining 15.0 degrees for external rotation and 18.8 degrees for adduction. Glenosphere lateralization increased external rotation motion by 13. 6 degrees and adduction by 4.3 degrees. Implanting larger diameter glenospheres increased external rotation and adduction by 9.4 and 10.1 degrees respectively. Glenosphere tilt had a negligible effect on impingement-free ROM. Maximizing inferior glenosphere eccentricity, lateralizing the glenosphere, and implanting larger glenosphere diameters improves impingement-free range of motion, in particular external rotation, of an onlay RSA prosthesis. Surgeons’ awareness of these trends can help optimize glenoid component position to maximise impingement-free ROM for RSA. Further studies are required to validate these findings in the context of scapulothoracic motion and soft tissue constraints


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 136 - 136
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION. 3D preoperative planning software for anatomic and reverse total shoulder arthroplasty (ATSA and RTSA) provides additional insight for surgeons regarding implant selection and placement. Interestingly, the advent of such software has brought previously unconsidered questions to light on the optimal way to plan a case. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current glenoid implant selection and placement. METHODS. 172 ASES members completed an 18-question survey on their thought process for how they select and place a glenoid implant for both ATSA and RTSA procedures. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into three cohorts based on their responses to usage of 3D preoperative planning software: high users, seldom users, and non-users. Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement. RESULTS. 76 surgeons were grouped into the high user cohort, 66 into the seldom user cohort, and 30 into the non-user cohort. 61.9% of high users and 74.1% of seldom users performed >75 shoulder arthroplasties per year, whereas only 19.9% of non-users performed >75 arthroplasties per year (Figure 1). When questioned on glenoid implant type selection (augmented vs. non-augmented components), 80.3% of high users reported augment usage for both ATSA and RTSA, with using augments >45% of the time in 18.4% of ATSA cases and in 22.3% of RTSA cases. For seldom users, 80.3% reported augment usage in ATSA cases, and 70.3% in RTSA cases. Seldom users reported augment usage >45% of the time in 4.5% of ATSA cases and in 1.6% of RTSA cases. For non-preoperative planning users, 53.3% reported using augments in ATSA cases, and 48.3% for RTSA cases. Non-users used augmented glenoid components >45% of the time in 6.6% of ATSA cases and in 6.8% of RTSA cases. For resultant implant superior inclination in RTSA, 40.8% of high users aim for 0° of inclination, followed by 31.8% for seldom users and 16.7% of non-users (Figure 2). CONCLUSION. The results of this study show that 3D preoperative planning software has an influence on the decision making process when planning a shoulder arthroplasty. High volume shoulder arthroplasty surgeons report higher preoperative planning software usage than low volume surgeons, suggesting the utility of such software. Augmented glenoid component usage for both ATSA and RTSA is also higher for surgeons that use preoperative planning software, which either suggests the utility of augmented glenoid components, or that the use of such software creates the perceived need for augmented glenoid components. Lastly, surgeons who preoperatively plan tend to orient their glenoid components differently, which could suggest either a better understanding of the anatomy through the use of the software, or an influence on mindset regarding implant orientation resulting from software usage. This highlights an area for future work that could correlate clinical outcome data to implant selection and placement to prove what is the optimal plan for a given patient. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 6 - 6
1 May 2019
Jobin C
Full Access

Severe glenoid bone loss in patients with osteoarthritis with intact rotator cuff is associated with posterior glenoid bone loss and posterior humeral subluxation. Management of severe glenoid bone loss during shoulder arthroplasty is controversial and technically challenging and options range from humeral hemiarthroplasty, anatomic shoulder replacement with glenoid bone grafting or augmented glenoid component implantation, to reverse replacement with reaming to correct version or structural bone grafting or metallic augmentation of the bone deficiency. Shoulder replacement with severe glenoid bone loss is technically challenging and characterised by higher rates of complications and revisions. Hemiarthroplasty has limited benefit for pain relief and function especially if eccentric glenoid wear exists. Bone loss with >15 degrees of retroversion likely requires version correction include bone-grafting, augmented glenoid components, or reverse total shoulder replacement. Asymmetric reaming may improve version but is limited to 15 degrees of version correction in order to preserve subchondral bone and glenoid bone vault depth. Bone-grafting of glenoid wear and defects has had mixed results with graft-related complications, periprosthetic radiolucent lines, and glenoid component failure of fixation. Implantation of an augmented wedge or step polyethylene glenoid component improves joint version while preserving subchondral bone, but is technically demanding and with minimal short term clinical follow-up. A Mayo study demonstrated roughly 50% of patients with posteriorly augmented polyethylene had radiolucent lines and 1/3 had posterior subluxation. Another wedge polyethylene design had 66% with bone ingrowth around polyethylene fins at 3 years. Long term outcomes are unknown for these new wedge augmented glenoid components. Reverse shoulder arthroplasty avoids many risks of anatomic replacement glenoid component fixation and stability but is associated with a high complication rate (15%) including neurologic and baseplate loosening and often requires structural bone grafting behind the baseplate with suboptimal outcomes or metallic augmented baseplates with limited evidence and short term outcomes. Reverse replacement with baseplate bone grafting or metal augmentation is technically challenging due to limited native glenoid bone stock available for baseplate component ingrowth and long term fixation. Failure to correct glenoid superior inclination and restore neutral version within 10 degrees increases the risks of reverse baseplate failure of fixation, pull out, and failure of reverse replacement. Reverse baseplate failure rates in patients with severe glenoid bone loss and concomitant glenoid bone grafting range from 5–11%. The minimum native glenoid bony contact with the baseplate is unknown but likely is approximately 1cm of native bone contacting a central ingrowth post and a minority (∼15–25%) of native glenoid contacting the backside of the baseplate. Failure to correct posterior bone loss can lead to retroversion of the baseplate, reduced external rotation, posterior scapular notching, and posteromedial polyethylene wear. In summary, shoulder replacement with severe glenoid bone loss is technically challenging and characterised by higher rates of complication and revision


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 10 - 10
1 Apr 2019
De Biase C Fiorentino G Catellani F Ziveri G Banci L Meoli A Bloch HR
Full Access

Background. The current use of a spherical prosthetic humeral head in total shoulder arthroplasty results in an imprecise restoration of the native geometry and improper placement of the center of rotation, maintained in a constant position, in comparison to the native head and regardless of glenoid component conformity. A radially-mismatched spherical head to allow gleno-humeral translation is a trade-off that decreases the contact area on the glenoid component, which may cause glenoid component wear. This finding suggests that the use of a non-spherical head with a more conforming glenoid component may reduce the risk of glenoid component wear by allowing gleno-humeral translation while increasing the contact area. A non-spherical prosthetic head more accurately replicates the head shape, rotational range of motion and gleno-humeral joint kinematics than a spherical prosthetic head, compared with the native humeral head. The combination of inversion of the bearing materials with the non-spherical configuration of the humeral head may thus decrease polyethylene wear. Aim of the present study is to evaluate in vitro wear behaviour of an all-polyethylene elliptical humeral head component against a metallic glenoid component in an anatomic configuration. Material and methods. The prosthetic components tested are from the Mirai. ®. Modular Shoulder System by Permedica S.p.A.. The prosthetic bearing components were tested in their anatomic configuration: the humeral head rubbing against the glenoid inlay, assembled over the glenoid base-plate. The glenoid insert is made of Ti6Al4V alloy coated with TiNbN. The glenoid insert, as the glenoid base-plate have the same shape which reproduce the native shape of the glenoid. Moreover, the glenoid insert has a concave articular surface described by two different radii on orthogonal planes. The vitamin E-blended UHMWPE humeral head is not spherical but elliptic-shaped with an articular surface described by two different profiles in sagittal and coronal plane. The component sizes combination tested have the greatest radial mismatches allowed between humeral head and glenoid insert. The test was performed up to 2.5 million of cycles applying a constant axial load of 756 N. Results. After 2.500.000 cycles the mean mass loss from the humeral head was 0.68 mg. The mean wear rate of the humeral head was 0.28 mg/Mc (SD 0.45 mg/Mc). The surface of the humeral heads showed an elliptical worn area with matt and polished areas with scratching. The surface of the TiNbN-coated glenoid insert counterparts did not show wear signs. Conclusion. The tested prosthetic humeral head has a non-spherical shape with an elliptical base and 2 different radii on sagittal and coronal plane. Also the tested glenoid insert has 2 different radii on sagittal and coronal planes. This components geometry leads to a radial mismatch between head and glenoid on sagittal and coronal planes. A different kinematics, allowing gleno-humeral translation while increasing the contact area, radial mismatch in different planes and the inversion of bearing materials may have a role in reducing component wear and may explain the extremely low wear rate found in the present study


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 64 - 64
1 Apr 2019
Greene A Cheung E Polakovic S Hamilton M Jones R Youderian A Wright T Saadi P Zuckerman J Flurin PH Parsons I
Full Access

INTRODUCTION. Preoperative planning software for reverse total shoulder arthroplasty (RTSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. While anatomical studies have defined the range of normal values for glenoid version and inclination, there is no clear consensus on glenoid component selection and position for RTSA. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in RTSA. METHODS. CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided four glenoid baseplate implant types: a standard non-augmented component, an 8° posterior augment wedged component, a 10° superior augment wedged component, and a combined 8° posterior and 10° superior wedged augment component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior-posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case. RESULTS. Two cases were excluded due to extreme deformity and consensus that a feasible RTSA may not be possible. For resultant implant version, a bimodal distribution was observed with a local maxima occurring at 0°, and a bell-shaped distribution at −5° of version. Upon individual surgeon analysis, it was revealed that certain surgeons had a preference to correct to 0 degrees, whereas others were more accepting of residual version. As well, the surgeons accepting residual retroversion removed less bone on average per implant type than the surgeons who aimed to correct to 0°. For resultant implant inclination, surgeons consistently tried to plan for 0 degrees of inclination. CONCLUSION. This study indicates that while there was limited consensus on the optimal reconstruction in any one case, there appear to be thresholds of retroversion and inclination that favor the use of augmented glenoid components based on frequency of selection. Our results indicate a wide variability in terms of what experienced shoulder surgeons consider to be an optimal reconstruction despite the common goal of attempting to restore anatomy, maximize implant fixation in bone and minimize bone removal. High frequency of augmented glenoid component use raises questions about how much retroversion and inclination is optimal and whether this technology allows surgeons to potentially focus more on a quantitative reconstruction relative to the Friedman axis versus a qualitative implant placement relative to what may be normal anatomy for a patient


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 63 - 63
1 Apr 2019
Greene A Cheung E Polakovic S Hamilton M Jones R Youderian A Wright T Saadi P Zuckerman J Flurin PH Parsons I
Full Access

INTRODUCTION. Preoperative planning software for anatomic total shoulder arthroplasty (ATSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in ATSA. METHODS. CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided three implant types: a standard non-augmented glenoid component, and an 8° and 16° posterior augment wedge glenoid component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior- posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case. RESULTS. Five cases were excluded due to extreme glenoid wear. For resultant implant version, a bimodal distribution was observed with a local maxima occurring at 0 degrees, and a bell-shaped distribution at −5° of version. Upon individual surgeon analysis, it was revealed that certain surgeons had a preference to correct to 0 degrees, whereas others were more accepting of residual version. Shoulders ranged in native version from 0° to −27° with an average of −11°, indicating a high frequency of posterior glenoid wear. The frequency of different implants used for each degree of version shows that standard implants were never used when version was > −11°. Conversely, 16° augmented glenoids were never used when the version was < −9°. Based on this distribution, version was divided into 3 ranges: < −6°, −7 to −14°, and > −15°. Standard glenoids were used 79% of the time when the version was <−6°. 8° augmented glenoids were used 80% of the time when the version was between −7° and −14°, and 75% of the time when the version was > −15°. In the latter case, 16° augments were used in the other 25%. For inclination in ATSA, the same trends of a bimodal distribution seen for version were less pronounced. A local maxima of plans were focused around zero degrees, with some surgeons being more accepting of superior inclination in ATSA. CONCLUSION. While there was limited consensus on the optimal reconstruction in any one case, there appear to be thresholds of retroversion that favor the use of augmented glenoid components based on frequency of selection. Our data suggests when retroversion exceeds −7°, some degree of augmentation is helpful in achieving the goals of version correction while limiting bone loss through corrective reaming. Longer term clinical outcomes on specific implant positions will help to define true optimal implant placement


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 73 - 73
1 Jul 2020
Yeoh J Chin P Regan WD Lim B Sasyniuk T Sayre E
Full Access

Glenoid failure remains the most common mode of total shoulder arthroplasty failures. Porous tantalum metal (Trabecular Metal™, Zimmer) have grown in popularity in hip and knee arthroplasty. First-generation porous tantalum metal-backed glenoid components demonstrated metal debris, resulted in failure, and were revised to second-generation glenoid implants. Evidence for second-generation porous tantalum metal implants in shoulder arthroplasty is sparse.1–4 The purpose of this study was to assess clinical and radiographic outcomes in a series of patients with second-generation porous tantalum glenoid components at a minimum two-years postoperative. We retrospectively reviewed the clinical and radiographic outcomes of patients who received a second-generation porous tantalum glenoid component anatomic shoulder arthroplasty between May 2009 and December 2017 with minimum 24 months follow-up. The shoulder arthroplasties were performed by one of two senior fellowship-trained surgeons. We collected postoperative clinical outcome indicators: EQ5D visual analog scale (VAS), Western Ontario Osteoarthritis of the Shoulder (WOOS) Index, American Shoulder and Elbow Surgeons (ASES) Score, and Constant Score (CS). Radiographic review was performed by an independent fellowship-trained surgeon. The Endrizzi metal debris grading system1 was utilized to grade metal debris. We computed descriptive statistics and compared outcome scores between groups via the non-parametric Wilcoxon rank-sum test, with group-wise comparisons defined by: metal debris and humeral head migration (secondary analyses). Thirty-five patients [23 male (65.7%) and 12 female (34.3%)] with 40 shoulder replacements participated in the study. Forty of 61 shoulders (65.6%) had an average of 64 ± 20.3 months follow-up (range 31 to 95). Average BMI was 27.5 ± 4.4 kg/m2 (range 19.5 to 39.1). The average postoperative EQ5D VAS at final follow-up was 74.6 ± 22.5, WOOS Index 87.9 ± 16.6, ASES Score 88.3 ± 10.9, and CS 80.4 ± 13. At final follow-up, 18 of 40 shoulders (45%) had metal debris [15 of 40 (37.5%) Endrizzi grade 1 and three of 40 (7.5%) Endrizzi grade 2], and 22 of 40 shoulders (55%) did not show evidence of metal debris. There was one non-revision reoperation (open subscapularis exploration), one shoulder with anterosuperior escape, three shoulders with glenoid radiolucencies indicative of possible glenoid loosening, and nine shoulders with superior migration of the humeral head (>2mm migration at final follow-up compared to immediate postoperative). When comparing postoperative scores between patients with vs without metal debris, we found no statistically significant difference in the EQ5D VAS, WOOS Index, ASES Score and CS. On further analyses, when comparing superior migration of the humeral head and postoperative outcomes scores, we found no statistically significant difference. We report the longest published follow-up with clinical and radiographic outcomes of second-generation porous tantalum glenoid anatomic shoulder arthroplasties. In this series of patients, 45% of total shoulder arthroplasties with a second-generation porous tantalum glenoid implant had radiographic evidence of metal debris. This metal debris was not statistically associated with poorer postoperative outcomes. Further investigation and ongoing follow-up are warranted


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 30 - 30
1 Dec 2022
Lohre R Lobo A Bois A Pollock J Lapner P Athwal G Goel D
Full Access

Glenoid baseplate orientation in reverse shoulder arthroplasty (RSA) influences clinical outcomes, complications, and failure rates. Novel technologies have been produced to decrease performance heterogeneity of low and high-volume surgeons. This study aimed to determine novice and experienced shoulder surgeon's ability to accurately characterise glenoid component orientation in an intra-operative scenario. Glenoid baseplates were implanted in eight fresh frozen cadavers by novice surgical trainees. Glenoid baseplate version, inclination, augment rotation, and superior-inferior centre of rotation (COR) offset were then measured using in-person visual assessments by novice and experienced shoulder surgeons immediately after implantation. Glenoid orientation parameters were then measured using 3D CT scans with digitally reconstructed radiographs (DRRs) by two independent observers. Bland-Altman plots were produced to determine the accuracy of glenoid orientation using standard intraoperative assessment compared to postoperative 3D CT scan results. Visual assessment of glenoid baseplate orientation showed “poor” to “fair” correlation to 3D CT DRR measurements for both novice and experienced surgeon groups for all measured parameters. There was a clinically relevant, large discrepancy between intra-operative visual assessments and 3D CT DRR measurements for all parameters. Errors in visual assessment of up to 19.2 degrees of inclination and 8mm supero-inferior COR offset occurred. Experienced surgeons had greater measurement error than novices for all measured parameters. Intra-operative measurement errors in glenoid placement may reach unacceptable clinical limits. Kinesthetic input during implantation likely improves orientation understanding and has implications for hands-on learning


We compared the rate of revision of two classes of primary anatomic shoulder arthroplasty, stemmed (aTSA) and stemless (sTSA) undertaken with cemented all polyethylene glenoid components. A large national arthroplasty registry identified two cohort groups for comparison, aTSA and sTSA between 1. st. January 2011 and 31. st. December 2020. A sub-analysis from 1 January 2017 captured additional patient demographics. The cumulative percentage revision (CPR) was determined using Kaplan-Meier estimates of survivorship and hazard ratios (HR) from Cox proportional hazard models adjusted for age and gender. Of the 7,533 aTSA procedures, the CPR at 8 years was 5.3% and for 2,567 sTSA procedures was 4.0%. There was no difference in the risk of revision between study groups (p=0.128). There was an increased risk of revision for aTSA and sTSA undertaken with humeral head sizes <44mm (p=0.006 and p=0.002 respectively). Low mean surgeon volume (MSV) (<10 cases per annum) was a revision risk for aTSA (p=0.033) but not sTSA (p=0.926). For primary diagnosis osteoarthritis since 2017, low MSV was associated with an increased revision risk for aTSA vs sTSA in the first year (p=0.048). Conversely, low MSV was associated with a decreased revision risk for sTSA in the first 6 months (p<0.001). Predominantly aTSA was revised for loosening (28.8%) and sTSA for instability/dislocation (40.6%). Revision risk of aTSA and sTSA was associated with humeral head size and mean surgeon volume but not patient characteristics. Inexperienced shoulder arthroplasty surgeons experience lower early revision rates with sTSA in the setting of osteoarthritis. Revision of aTSA and sTSA occurred for differing reasons