Advertisement for orthosearch.org.uk
Results 1 - 20 of 50
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 69 - 69
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Bispo C
Full Access

Radial head fractures are among the most common fractures around the elbow. Radial head arthroplasty is one of the surgical treatment options after complex radial head fractures. This surgery is usually done under general anaesthesia. However, there is a recent anaesthetic technique - wide awake local anaesthesia no tourniquet (WALANT) - that has proven useful in different surgical settings, such as in distal radius or olecranon fractures. It allows a good haemostatic control without the use of a tourniquet and allows the patient to actively collaborate during the surgical procedure. Furthermore, there are no side effects or complications caused by the general anaesthesia and there's an earlier patient discharge. The authors present the case of a seventy-six-year-old woman who presented to the emergency department after a fall from standing height with direct trauma to the left elbow. The radiological examination revealed a complete intra-articular comminuted fracture of the radial head (Mason III). Clinical management: The patient was submitted to surgery with radial head arthroplasty, using WALANT. The surgery was successfully completed without pain. There were no intra or immediate post-operative complications and the patient was discharged on the same day. Six weeks after surgery, the patient had almost full range of motion and was very pleased with the functional outcome, with no limitations on her activities of daily living. The use of WALANT has been expanded beyond the hand and wrist surgery. It is a safe and simple option for patients at high risk of general anaesthesia, allowing similar surgical outcomes without the intraoperative and postoperative complications of general anaesthesia and permitting an earlier hospital discharge. Furthermore, it allows the patient to actively collaborate during the surgery, providing the surgeons the opportunity to evaluate active mobility and stability, permitting final corrections before closing the incision


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 10 - 10
17 Apr 2023
Constant C Moriarty T Pugliese B Arens D Zeiter S
Full Access

Orthopedic device-related infection (ODRI) preclinical models are widely used in translational research. Most models require induction of general anesthesia, which frequently results in hypothermia in rodents. This study aimed to evaluate the impact of peri anesthetic hypothermia in rodents on outcomes in preclinical orthopedic device-related infection studies. A retrospective analysis of all rodents that underwent surgery under general anesthesia to induce an ODRI model with inoculation of Staphylococcus epidermidis between 2016 and 2020 was conducted. A one-way multivariate analysis of covariance was used to determine the fixed effect of peri anesthetic hypothermia (hypothermic defined as rectal temperature <35°C) on the combined harvested tissue and implant colonies forming unit counts, and having controlled for the study groups including treatments received duration of surgery and anesthesia and study period. All animal experiments were approved by relevant ethical committee. A total of 127 rodents (102 rats and 25 mice) were enrolled in an ODRI and met the inclusion criteria. The mean lowest peri-anesthetic temperature was 35.3 ± 1.5 °C. The overall incidence of peri-anesthetic hypothermia was 41% and was less frequently reported in rats (34% in rats versus 68% in mice). Statistical analysis showed a significant effect of peri anesthetic hypothermia on the post-mortem combined colonies forming unit counts from the harvested tissue and implant(s) (p=0.01) when comparing normo- versus hypothermic rodents. Using Wilks’ Λ as a criterion to determine the contribution of independent variables to the model, peri-anesthetic hypothermia was the most significant, though still a weak predictor, of increased harvested colonies forming unit counts. Altogether, the data corroborate the concept that bacterial colonization is affected by abnormal body temperature during general anesthesia at the time of bacterial inoculation in rodents, which needs to be taken into consideration to decrease infection data variability and improve experimental reproducibility


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 109 - 109
1 Nov 2021
Rigney B Casey C Donald CM Pomeroy E Cleary M
Full Access

Introduction and Objective. Wide awake local anaesthetic no tourniquet (WALANT) is being used for a wide variety of hand and wrist surgery. It has recently been used in distal radius fracture fixation. The purpose of this systematic review and meta-analysis was to assess the effectiveness of the WALANT technique in open reduction internal fixation. Materials and Methods. Pubmed, Embase, and Scopus databases were searched on 02/03/21 with the following search terms: radius, WALANT, local anesthetic, wide awake surgery. The primary outcome measure was conversion to general anaesthetic and mean intra-operative visual analogue scale (VAS) pain scores. Secondary measures were operative times, mean intraoperative blood loss, post-operative functional and radiological outcomes. Results. 110 articles were identified; eight studies were deemed eligible with 212 in the WALANT group and 247 in the comparative groups of regional anaesthesia and general Anaesthesia (GA). Two patients in the WALANT group required conversion to general anaesthesia due to anxiety rather than pain. Intra-operative VAS pain scores in the WALANT and regional anaesthetic group were 1.75 and 2.86 respectively (p<0.001). There was no statistically significant difference in Q-DASH scores, range of motion or radiological outcomes. There was a slight increase in mean blood loss in the WALANT group compared with those given a GA or regional anaesthetic with tourniquet (22.5ml vs 12.15ml, p<0.001). Conclusions. The WALANT technique is a viable option for anaesthetic when performing distal radius fracture fixation. It is well tolerated, giving similar post-operative outcomes to other anaesthetic methods. It is a potentially useful technique in a centre with an underresourced anaesthetic department or for patients who may not tolerate regional and general anaesthetic methods. Adequate patient counselling prior to the procedure should be performed with appropriate patient selection


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 13 - 13
1 Dec 2021
Ramesh K Yusuf M Makaram N Milton R Mathew A Srinivasan M
Full Access

Abstract. Objective. To investigate the safety and cost-effectiveness of interscalene brachial plexus block/regional anaesthesia (ISB-RA) in patients undergoing reverse total shoulder replacement. Methods. This retrospective study included 15 patients with symptomatic rotator cuff arthropathy who underwent reverse total shoulder arthroplasty (rTSA) under ISB-RA without general anaesthesia in the beach chair position from 2010 to 2018. The mean patient age was 77 years (range 59–82 years). Patients had associated medical comorbidities: American Society of Anesthesiologists (ASA) grade 2–4. Assessed parameters were: duration of anaesthesia, intra-operative systolic blood pressure variation, sedation and vasopressor use, duration of post-operative recovery, recovery scores, length of stay, and complications. A robust cost analysis was also performed. Results. The mean (range) duration of anaesthesia was 38.66 (20–60) min. Maximum and minimum intra-operative systolic blood pressure ranges were 130–210 and 75–145 mmHg, respectively (mean [range] drop, 74.13 [33–125] mmHg). Mean (range) propofol dose was 1.74 (1–3.0) mg/kg/h. The Median (interquartile range) post-operative recovery time was 30 (20–50) min. The mean (range) postoperative recovery score (local scale, range 5–28 where lower values are superior) was 5.2 (5–8). The mean (range) length of stay was 8 (1–20 days); the two included patients with ASA grade 2 were both discharged within 24 hours. One patient with predisposing history developed pneumonia; however, there were no complications related to ISB-RA. The mean (range) cost per patient was £101.36 (£59.80-£132.20). Conclusions. Our data demonstrate that rTSA under ISB-RA is safe, cost-effective and a potentially viable alternative for patients with multiple comorbidities. Notably, patients with ASA grade 2 who underwent rTSA under ISB-RA had a reduced length of stay and were discharged within 24 hours


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 76 - 76
1 Mar 2021
Peters J Wickramarachchi L Thakrar A Chin K Wong J Mazis G Beckles V
Full Access

Abstract. Objectives. Our objective was to determine the incidence of post-operative COVID-19 infection within the first two weeks following treatment at the COVID-free site. During the COVID-19 pandemic our hospital saw one of the highest rates of COVID-19 infection in the United Kingdom. As a result, our trauma services were relocated to a vacant private elective hospital to provide a ‘COVID-free’ setting for trauma patients. Patients admitted to the COVID-free site were screened for coronavirus infection and only treated at that site if asymptomatic. Those with symptoms were treated at the ‘COVID’ site. Method. We collected data at the COVID-free site during the first seven weeks of its’ establishment. Inclusion criteria were all patients presenting for operative management of limb trauma; however, fragility hip fractures were excluded. All patients were screened for symptoms of COVID-19 infection at their 2-week follow-up appointment. Results. 72 patients presented to our service during the study period. The mean age was 34.9 years (21 to 89). 62 patients had general anaesthesia (86%), 7 patients had regional anaesthesia (10%) and 3 patients had local anaesthesia (4%). One asymptotic patient who was swabbed for COVID-19 on admission returned a positive result. This patient had contracted the infection before surgery and was excluded from further analysis. 71 patients (100%) remained asymptomatic at follow-up and none had required medical attention for suspected COVID-19 infection. Conclusion. A ‘COVID-free’ trauma service was established in a private elective hospital during the pandemic. None of the patients undergoing urgent trauma surgery in this setting developed COVID-19 symptoms as a result of their hospital admission. Establishing a separate site with screening to avoid admission of patients with COVID-19 infection can allow safe emergency surgery. This data can support informed consent and reassure patients of their risks when we resume day case and elective surgery. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 90 - 90
1 Mar 2021
Krticka M Nekuda V Trunec M Brinek A Sedlacek R Lukasova V Göpfrt E Stastny P Kafkova M Ira D Rampichova M Planka L Vojtova L
Full Access

The use of lumbar fusion procedures in the USA and Europe has rapidly increased over the last decade and a large number of these procedures involve the use of bone grafts. Despite of technical progress of spinal surgery and operative materials the risk of vertebral fusion failure occurs in 5 – 35 % of cases. Autografting has been considered the gold standard for bone graft procedures. However, the harvesting from the iliac crest can be associated with short and long-term morbidity in up to 22 % of cases. Main goal of this experimental study was to compare newly developed hybrid biodegradable nanocomposit porous implant (HBNPI) against bone craft from iliac crest as a new and better alternative for lumbar interbody fusion. 24 male pigs 4 months old weighting around 40 Kg were included in our study. These pigs were divided into two study groups depending on fusion method. Group A – 12 pigs underwent lateral lumbal interbody fusion (L2/3) with implantation of iliac crest bonegraft. Group B - 12 pigs underwent lateral lumbal interbody fusion (L2/3) with newly developed HBNPI. Each group were divided into two subgroups from these 6 spines were harvested 8 weeks (subgroup A1, B1) and 6 spines 16 weeks (group A2, B2) after surgery. After sacrifice, the lumbar spines were taking out and micro-CT, biomechanical testing and histomorphological analysis in all groups were performed to evaluate a quality of intervertebral fusion. As controls (group N), 6 cadaveric intact lumbar spines underwent biomechanical, micro-CT and histological testing. All 24 animals recovered from general anesthesia without unusual events. The operations lasted between 50–90 minutes (mean 70) in Group A and between 35–72 minutes (mean 43) in Group B. All of the pigs from group A could stand up and were mobile within 20 hours (range 7–20). When bone graft harvesting was not necessary (group B) this time was shortened, ranging from 1 – 1,5 hour. All pigs from Group A were limping on the first postoperative day. No limping animal was observed in group B. Total body weight of the pigs increased from 37 kg (range 36–40) at the start to 85 (range 80–89) at sacrifice. Biomechanics evaluation shows that extension flexural stiffness values are statistically significantly different between A2 (16 weeks post-implant) and A1 (8 weeks post-implant). Group A2 achieves higher values than Group A1, which is attributed to the adhesion of the implant to the surrounding vertebrae. Similarly, this also applies to groups B2 and B1. The flexural stiffness at group B2 extension is statistically significantly higher than the A2 group and also than the native N group. Biomechanical evaluation supports findings on micro-CT and histological specimens, where both adjacent vertebrae are completely fused in groups B2, unlike in group A2, where there is no or incomplete fusion. Newly developed HBNPI represents new possibility how to do intervertebral fusion, and simultaneous become chance how to improve and accelerate bone healing process against standard procedures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 20 - 20
1 Dec 2020
Sozbilen MC Sahin KE
Full Access

Botulinum toxin A (BoNT-A) is a substance that requires repeated application due to its effectiveness being lost 12–16 weeks post application. Performing these intra-muscular injections under anesthesia reduces pain and distress during applications, ensuring effective and successful functional results. This study evaluates motor development of patients undergoing 3 or more repeated BoNT-A application in a tertiary pediatric hospital and the safety as well as effect of 3 different types of anesthesia. 75 children with cerebral palsy who underwent BoNT-A application at least three times consecutively with 6-month intervals and a total of 320 procedures admitted between January 2008 and January 2018 were retrospectively examined. Gross Motor Function Classification System (GMFCS) was employed in motor development evaluation. To observe the improvement in motor development, those with 2-1-0 level decreases in GMFCS classes were grouped and compared in terms of birth time, birth weight, cerebral palsy type and first BoNT-A application age. The 3 types of anesthesia methods (sedation analgesia, larengeal mask anesthesia (LMA) and inhalation mask anesthesia) applied during the procedures were compared in terms of sedation, procedure, recovery and total operation room time. The mean age of the children for all procedures was 45.51 ± 22.40 months. As a result of procedures, significant motor development was observed in 60 (80%) patients (p <0,000∗). No significant difference was observed when the children with cerebral palsy whose GMFCS declined in the form of level 2, 1 and unchanged were compared in terms of first application age, birth weight and gestational age. It was found that 106 (33.1%) were applied sevoflurane with anesthesia mask, 103 (32.1%) were administered sevoflurane with laryngeal mask, and 111 (34.6%) were sedation-analgesia. Only 10 out of 320 procedures were seen to develop side effects (8 vomiting, 2 bronchospasm). In the patients who underwent sedation analgesia during the first 3 BoNT-A procedures, the duration of recovery and total operating room time was seen to be significantly shorter than the others, while there was no difference between the anesthesia methods in the 4th and subsequent procedures. Regardless of the type of anesthesia, the recovery and total operating room times of those having undergone 6 or more procedures were longer than those with less than 6 procedures (p <0.009, p <0.016, respectively). As conclusion, repeated BoNT-A applications in children with CP provides progress in motor steps, it can be applied safely and effectively under anesthesia. Sedation analgesia application provides easier recovery compared to general anesthesia with LMA and mask only in the first three applications. However, recovery time increases with 4 and more repeated applications as the number of applications increases


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 114 - 114
1 Dec 2020
Cullu E Olgun H Tataroğlu C Ozgezmez FT Sarıerler M
Full Access

Thermal osteonecrosis is a side effect when used Kirschner (K) wires and drills in orthopaedic surgeries. This osteonecrosis may endanger the fixation. Orthopaedic surgeons sometimes have to use unsharpened K-wires in emergent surgery. The thermal effect of used and unsharpened K wire is ambiguous to the bone. This experimental study aims to assess the thermal osteonecrosis while drilling bone with three different types of K-wires especially a previously used unsharpened wire and its thermographic measurements correlation. Two different speeds of rotation were chosen to investigate the effect of speed on thermal necrosis to the bone. A total of 16 New Zealand white rabbits weighing a mean of 2.90 kg (2.70 – 3.30 kg) were used. All rabbits were operated under general anaesthesia in a sterile operating room. Firstly, 4 cm longitudinal lateral approach was used to the right femur and then the femur was drilled with 1.0 mm trochar tip, spade tip and previously used unsharpened K-wires and 1.0 mm drill bit at 1450 rpm speed. Left femur was drilled with same three type K-wires and drill bit at 330 rpm speed. One cm distance was left among four penetrations on the femur. The thermal changes were recorded by Flir® E6 Thermal Camera from 50 cm distance and 30-degree angle. Thermographic measurements saved for every drilling process and recorded for the highest temperature (°C) during the drilling. All subjects were sacrificed post-operatively on the eighth day and specimens were prepared for the histological examination. The results of osteonecrosis assessment score and thermographic correlation were evaluated statistically. Histological specimens were evaluated by the scoring of osteonecrosis, osteoblastic activity, haemorrhage, microfracture and inflammation. Results were graded semi-quantitatively as none, moderate or severe for osteonecrosis, haemorrhage and inflammation. The microfracture and osteoblastic activity were evaluated as present or absent. There was no meaningful correlation between osteonecrosis and the drilling speed (p=0.108). There was less microfracture zone which was drilled with trochar tip K-wires at 1450 rpm speed (p=0.017). And the drilling temperature of trochar tip K-wires was higher than the others(p=0.001). Despite this evaluation, osteonecrosis zone of spade and unsharpened tip K-wires were more than trochar tip K-wires (p=0.039). The drill bit at 330 rpm caused the least osteonecrosis and haemorrhage and respectfully the lowest drilling temperature (p=0,001). The osteoblastic activity shows no difference between the groups. (p=0,122; 0,636;0.289). On the contrary to the literature, our experiment showed that there is no meaningful correlation between osteonecrosis score and temperature produced by drilling. The histological assessment showed the osteonecrosis during short drilling time but, not clarify the relation with drilling temperature. Eventually, the osteonecrosis showed a positive correlation with drilling time independently of drilling temperature at 330 rpm. (p=0,042) These results show that we need more studies to understand about osteonecrosis and its relationship with drilling heat temperature. Trochar tip K-wires creates higher drilling temperature but less osteonecrosis than a spade and unsharpened cut tip K-wires. Using unsharpened tip K-wire causes more osteonecrosis. Previously used and, unsharpened K-wires should be discarded


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 61 - 61
1 Nov 2018
Reifenrath J Schröder ML Fedeeva E Calliess T Angrisani N
Full Access

Implant infection is an increasing problem in orthopedic surgery, especially due to progressive antibiotic resistance and an aging population with rising numbers of implantations. As a consequence, new strategies for infection prevention are necessary. In the previous study it was hypothesized that laser-structured implant surfaces favor cellular adhesion while hindering bacterial ongrowth and therewith contribute to reduce implant infections. Cuboid titanium implants (0.8 × 0.8 × 12 mm. 3. , n=34) were used. Seventeen were laser-structured by ultra-short pulsed laser ablation to create a spike structure; the others were polished and served as controls. In general anesthesia, implants were inserted in rat tibiae and infected with a S. aureus suspension. During a 21 day postoperative follow-up, daily clinical control was performed. Radiographs were taken at day 14 and day 21. After euthanasia, bacterial load and biofilm formation on the implant surface was evaluated semi quantitatively by confocal laser scanning microscopy and computational acquisition of bacteria and cells by Imaris®-software. Additionally, histology of the surrounding bone was performed. Clinically, no differences were observed between the groups. However, contrary to our hypothesis, bacterial load was increased in the laser-structured implant group although cellular adhesion was even more pronounced. Radiographical and histological evaluations showed increased bone alterations in the group with laser-structured implants compared to the control group. These findings did not confirm prior in vitro studies, where a reduction of bacterial load was found for similar surfaces and demonstrate the necessity of in vivo trials prior to the clinical use of new materials


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 346 - 346
1 Jul 2014
Wang F Wu R
Full Access

Summary Statement. Osteonecrosis of the femoral head (ONFH) is a multifactorial skeletal disorder. S100A9 represseses angiogenesis and vessel integrity in ONFH. It also may function as a marker of diagnosis in ONFH. Introduction. Osteonecrosis of the femoral head (ONFH) is a multifactorial skeletal disorder characterised by ischemic deterioration, bone marrow edema and eventually femoral head collapse and joint destruction. Several surgical, pharmaceutical and non-invasive biophysical modalities have been employed to alleviate this joint disorder. Our proteomic analysis showed that ONFH patients displayed increased expression of S100A9 protein when compared with healthy volunteers. This study is designed to evaluate the pathogenesis of S100A9 on the patients of ONFH. Patients & Methods. We collected 56 patients with ONFH including stage I, II, III and IV and 14 health volunteers. 20 ml of peripheral venous blood is drawn from each subject or prior to general anesthesia for hip arthroplasty. We compared the ELISA of S100A9, Osteocalcin, TRAP-5b, sVCAM-1. Immunohistochemistry of S100A9, vWF and VEGF are compared using femoral head harvested from late stages of ONFH and femoral neck fracture when received hip arthroplasty. In vitro angiogenic assay was performed by tube formation assay. Results. There were significant elevation of S100A9 in the serum of ONFH patients then in healthy volunteers. sVCAM-1 and TRAP-5b were increased and Osteocalcin was decreased in ONFH patient when comapred with healthy volunteers. The expression of S100A9 protein in ONFH tissue was significantly higher than femoral neck fracture tissue. In tube formation assay, we found S100A9 and the serum of ONFH patient supressed angiogenesis in vascular endothelial cell culture. Discussion/Conclusion. The expression of S100A9 significantly increased in the serum and femoral head tissue of patients with ONFH. S100A9 also supressed angiogenesis expression. The results indicated that S100A9 represseses angiogenesis and vessel integrity in ONFH. It also may function as a marker of diagnosis in ONFH


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 902 - 906
1 Sep 1999
Ochi M Iwasa J Uchio Y Adachi N Sumen Y

We examined whether somatosensory evoked potentials (SEPs) were detectable after direct electrical stimulation of injured, reconstructed and normal anterior cruciate ligaments (ACL) during arthroscopy under general anaesthesia. We investigated the position sense of the knee before and after reconstruction and the correlation between the SEP and instability. We found detectable SEPs in all ligaments which had been reconstructed with autogenous semitendinosus and gracilis tendons over the past 18 months as well as in all cases of the normal group. The SEP was detectable in only 15 out of 32 cases in the injured group, although the voltages in the injured group were significantly lower than those of the controls. This was not the case in the reconstructed group. The postoperative position sense in 17 knees improved significantly, but there was no correlation between it and the voltage. The voltage of stable knees was significantly higher than that of the unstable joints. Our findings showed that sensory reinnervation occurred in the reconstructed human ACL and was closely related to the function of the knee


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 16 - 16
1 Jun 2012
Russell D Pillai A Anderson K Kumar C
Full Access

Regional anaesthetic for foot surgery has been discussed as a method of post operative analgesia. Ankle block as the sole anaesthetic for foot surgery has not been extensively reviewed in the literature. We aimed to describe our experience of forefoot surgery under ankle block. Sixty-six consecutive forefoot procedures (59 patients) were carried out under ankle block. Patients were contacted post operatively and completed a standardised questionnaire including an incremental pain assessment ranging from 0-10 (0 no pain, 10 severe pain). Forty nine female and 10 male patients (age range 20-85y) were included. Procedures included 33 first metatarsal osteotomies, 15 cheilectomies, 3 first MTP joint replacements, 5 fusions, 4 excision of neuroma and 6 other procedures. 22 patients (33% of cases) reported discomfort during the block procedure (average pain score 1.5). 6 patients reported pain during their operation(s), average score 0.26. Average pain scores at 6, 12, 24 and 48 hours following surgery were 2.0, 3.2, 2.7 and 2.1 respectively. All patients were discharged home and walking on the same day. There were no readmissions. Each patient confirmed they would have surgery under regional block rather than general anaesthesia and would recommend this technique to family and friends. There are many advantages in being able to perform these relatively small procedures under regional anaesthesia. The anaesthesia obtained permits the majority of forefoot procedures and provides lasting post-operative analgesia. Combined with intra-operative sedation, use of ankle tourniquet and same day discharge; it has very high patient acceptance and satisfaction


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 26 - 26
1 Apr 2012
Russell D Pillai A Kumar C Anderson K
Full Access

Regional anaesthetic for foot surgery has been discussed as a method of post operative analgesia. Ankle block as the sole anaesthetic for foot surgery has not been extensively reviewed in the literature. We aimed to describe our experience of forefoot surgery under ankle block alone. 21 consecutive forefoot procedures (18 patients) were carried out under ankle block. The blocks were performed by the senior authors. A mixture of 10ml 2% Lidocaine with 10ml 0.5 % Bupivacaine was administered to the superficial peroneal, deep peroneal, sural and saphenous nerves. Ankle tourniquet was employed in all procedures. The patients were contacted post operatively and completed a standardised questionnaire including an incremented pain assessment ranging from 0-10 (0 no pain, 10 severe pain). 17 female and 1 male patients were contacted (age range 33-67y). Procedures included 13 first metatarsal osteotomies, 3 cheilectomies, 2 first MTP joint replacements, and 5 fusions. 14 patients requested a short acting sedative (midazolam). 5 patients (27 %) reported some discomfort during the block procedure (average pain score 1.2). No patients reported any pain during their operation(s). 4 patients (22%) required supplementation of the block. Average pain score at 6, 12, 24 and 48 hours following surgery were 0.66, 2.9, 2.4 and 1.3 respectively. All patients were discharged home and walking on the same day. None complained of nausea or required parenteral analgesia; there were no readmissions. Each patient confirmed they would have surgery under local block rather than general anaesthesia and would recommend this technique to family and friends. Forefoot surgery under ankle block alone is safe and effective. Anaesthesia obtained permits the majority of forefoot procedures and provides lasting post-operative analgesia. Combined with intraoperative sedation, use of ankle tourniquet and same day discharge, it has very high patient acceptance and satisfaction


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 158 - 158
1 Jul 2014
Elnikety S Pendegrass C Holden C Blunn G
Full Access

Summary. Our results prove that Demineralised Cortical Bone (DCB) can be used as biological tendon graft substitute, combined with correct surgical technique and the use of suture bone anchor early mobilisation can be achieved. Introduction. Surgical repair of tendon injuries aims to restore length, mechanical strength and function. In severe injuries with loss of tendon substance a tendon graft or a substitute is usually used to restore functional length. This is usually associated with donor site morbidity, host tissue reactions and lack of remodelling of the synthetic substitutes which may result in suboptimal outcome. In this study we hypothesise that DCB present in biological tendon environment with early mobilisation and appropriate tension will result in remodelling of the DCB into ligament tissue rather that ossification of the DCB at traditional expected. Our preparatory cadaveric study (abstract submitted to CORS 2013) showed that the repair model used in this animal study has sufficient mechanical strength needed for this animal study. Methods. 6 mature female sheep undergone surgical resection of the distal 1 cm of the right patellar tendon and osteotomy of patellar tendon attachment at the tibial tuberosity under general anaesthesia. Repair was done using DCB with 2 suture bone anchor. Animals were allowed immediate mobilisation after surgery and were sacrificed at 12 weeks. The force passing through the operated and non-operated legs was assessed preoperatively and at week 3, week 6, week 9 and week 12 bay walking the animals over a force plate. Radiographs were taken immediately after euthanasia, the Patella-Tendon-tibia constructs were retrieved and pQCT scan was done. Histological analysis included tenocytes and chondrocytes cell counts, semi-quantitative scoring of the neo-enthesis and polarised microscopy. Result. In this study, none of the retrieved specimens showed any evidence of ossification of the DCB as proved by the pQCT analysis. One animal failed to show satisfactory progress after week 3, X-rays showed patella alta, on specimen retrieval no damage to the DCB was found, sutures and stitches were intact and no evidence of anchor pullout was found. Force plate analysis of the other 5 animals showed satisfactory progression over time with 44% functional weight bearing at week 3 progressing to 79% at week 12. There was full range of movement of the stifle joint after 12 weeks. Histological analysis proved formation of neo-enthesis with evidence of cellulisation, vascularisation and remodelling of the collagen leading to ligamentisation of the DCB. Discussion. Surgical reconstruction of damaged tendons is technically challenging, patellar tendon injuries presents even more challenging situation as it involves weight bearing joint. It is generally accepted that a period of immobilisation with passive range of movement exercises and protected weight bearing for up to 6 weeks post operatively is usually advised. Some surgeons use offloading metal wire to protect the repair for 6 weeks involving second surgical procedure to remove the wire. Demineralised bone is usually used in orthopaedics to utilise its osteogenic properties as bone graft substitute and to enhance osteogenesis in load bearing situations. In our study we explored a potential new use of the demineralised bone as tendon graft substitute, it acts as collagen scaffold allowing host cells to remodel its fibres into ligament like structure


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 196 - 196
1 Jul 2014
Lozano D López-Herrradón A Portal-Núñez S Ardura J Vila M Sánchez-Salced S Mulero F Gómez-Barrena E Vallet-Regí M Esbrit P
Full Access

Summary Statement. Parathytorid hormone-related protein (107–111) loaded onto biopolymer-coated nanocrystalline hydroxyapatite (HA. Glu. ) improves the bone repair in a cavitary defect in rat tibiae. Introduction. Biopolymer-coated nanocrystalline hydroxyapatite (HA. Glu. ) made as macroporous foams are promising candidates as scaffolds for bone tissue engineering applications. They exhibit optimal features, promoting internalization, proliferation and differentiation of osteoprogenitors, with an adequate cell colonization over the entire scaffold surface. Parathyroid hormone-related protein (PTHrP) is an important modulator of bone formation. Its 107–111 epitope (osteostatin) exhibits osteogenic properties at least in part by directly acting on osteoblasts. The main aim of this study was to evaluate whether osteostatin loading into HA. Glu. scaffolds might improve their bone regeneration capacity. Materials and Methods. HA. Glu. scaffolds were prepared as previously described (Sánchez-Salcedo S et al. J. Mater. Chem. 2010; 20:6956-61). Osteostatin was adsorbed onto HA. Glu. material by dipping into a solution containing this peptide at 100 nM (in phosphate-buffered saline, pH 7.4), following a standard protocol. We performed a cavitary defect (2 mm in diameter and 3 mm in depth) in both distal tibial metaphysis using a drill under general anesthesia in male Wistar rats (n=8) of 6 months of age. Unloaded HA. Glu. material (7 mg) was implanted into left tibial defects, whereas rigth tibial defects received the osteostatin-loaded material. Animals were sacrificed after 4 weeks for histological, μ-computerised tomography and gene expression analysis of the callus. Our protocol was approved by the Institutional Animal Care and Use Committee at the IIS-FJD. Mouse osteoblastic MC3T3-E1 cells were grown in differentiation medium (α-MEM with 10% fetal bovine serum, 50 µg/ml ascorbic acid, and 10 mM β-glycerolphosphate), in the presence or absence of HA. Glu. material with or without osteostatin. Cell viability (assessed by trypan blue staining), alkaline phosphatase (ALP) activity and mineralization (alizarin red) were analyzed at different culture times. Results. The mean uptake of osteostatin by HA. Glu. scaffolds was about 60 % (representing 0.7 μg/implanted scaffold) after 24 h of loading, and they released a mean of 80 % of loaded peptide to the surrounding medium within 1–24 h. At 4 weeks, this osteostatin-containing HA. Glu. material significantly increased the bone volumen fraction and trabecular thickness of regenerating bone in the tibial methaphysis, compared to those observed with unloaded HAGlu scaffolds. In addition, osteostatin-coated HA. Glu. scaffolds increased (2-fold) the gene expression of osteocalcin and vascular cell adhesion molecule 1, but decreased (2-fold) that of the Wnt inhibitors, SOST and Dickkopf homolog 1 (DKK-1) in the fracture callus. In MC3T3-E1 cell cultures, osteostatin-loaded HA. Glu. material increased cell viability and ALP activity (each by 30%), and matrix mineralization (by 50%) at days 4 and 10, respectively. Conclusions. These results indicate that osteostatin loading improves the bone regeneration capacity of HA. Glu. scaffolds. Our findings suggest that these scaffolds might be promising implants in orthopaedic applications. This work has been supported by a grant from Comunidad Autónoma de Madrid (S-2009/MAT/1472)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 40 - 40
1 May 2012
Eardley W Clasper J Midwinter M Watts S
Full Access

Crown copyright 2009. Published with the (permission of the Defence Science and Technology Laboratory on behalf of the Controller of HMSO. Introduction. The optimum strategy for the care of war wounds is yet to be established. A need exists to model complex extremity injury, allowing investigation of wound management options. Aim. To develop a model of militarily relevant extremity wounding. Study Design. Laboratory study with New Zealand White Rabbits. Methods. Phase 1. Development of injury. Following induction of general anaesthesia, a muscle belly on the flexor aspect of the forelimb of the rabbit was exposed. This was achieved by creating a fascial tunnel under the belly of flexor carpi ulnaris (FCU). Utilising a custom built drop test rig a high energy, short duration impact was delivered. To replicate casualty evacuation timelines, the animal was maintained under anaesthesia for three hours and recovered. The wound was dressed with saline soaked gauze and supportive bandaging. 48 hrs later, the animal was culled and the muscle harvested for histological analysis. Analgesia was administered once a day. Animals were checked by experienced staff at least twice a day and body temperature recorded by a subcutaneous transponder. Phase 2. Contamination of muscle injury. Sequential animals had inoculums of 1×102/100μl, 1×106/100μl and 1×108/100μl of Staphylococcus aureus administered to the muscle immediately after injury. Animals were recovered from anaesthetic and monitored as per phase 1. Delivery was evaluated by droplet spread and via injection by fine bore needle into the muscle belly. At the 48 hour point, the animals were culled, dressings removed, the muscle harvested and auxiliary lymph nodes sampled. Quantitative microbiological analysis was performed to determine colony forming unit counts (CFU) at 24 hours post-collection. Results. Phase 1. Six animals were exposed to a loading of 0.5kg. Histological analysis demonstrated a consistent injury pattern with 20% of the muscle belly becoming necrotic. Following discussion with subject matter experts this was found to be representative of the nature of injury from ballistic limb trauma and was adopted as standard. Phase 2. Twenty-two animals were exposed to the standardised injury and then inoculated at the prescribed challenge doses and delivery methods. A challenge dose of 1×106/100μl S. aureus delivered by droplet provided the greatest consistency. A group of six animals with an average challenge dose of 3.3×106/100μl yielded growth at 48hrs on average of 9.2×106 CFU. There were no adverse effects on animal welfare throughout, with body temperatures within normal limits at all times. Discussion. The use of rabbits in the investigation of musculoskeletal injury and infection is well established. No study to date however has addressed high energy complex soft tissue wounding, contamination and its optimum management. Considering the current burden of such wounds the need for this question to be answered in a research setting is transparent. This model enables a significant, reproducible, contaminated soft tissue injury to be delivered in vivo. It will allow the investigation of complex wound management options including wound coverage and fracture fixation


Bone & Joint Research
Vol. 6, Issue 4 | Pages 208 - 215
1 Apr 2017
Decambron A Manassero M Bensidhoum M Lecuelle B Logeart-Avramoglou D Petite H Viateau V

Objectives

To compare the therapeutic potential of tissue-engineered constructs (TECs) combining mesenchymal stem cells (MSCs) and coral granules from either Acropora or Porites to repair large bone defects.

Materials and Methods

Bone marrow-derived, autologous MSCs were seeded on Acropora or Porites coral granules in a perfusion bioreactor. Acropora-TECs (n = 7), Porites-TECs (n = 6) and bone autografts (n = 2) were then implanted into 25 mm long metatarsal diaphyseal defects in sheep. Bimonthly radiographic follow-up was completed until killing four months post-operatively. Explants were subsequently processed for microCT and histology to assess bone formation and coral bioresorption. Statistical analyses comprised Mann-Whitney, t-test and Kruskal–Wallis tests. Data were expressed as mean and standard deviation.


Bone & Joint Research
Vol. 6, Issue 2 | Pages 73 - 81
1 Feb 2017
Ishihara K Okazaki K Akiyama T Akasaki Y Nakashima Y

Objectives

Osteophytes are products of active endochondral and intramembranous ossification, and therefore could theoretically provide significant efficacy as bone grafts. In this study, we compared the bone mineralisation effectiveness of osteophytes and cancellous bone, including their effects on secretion of growth factors and anabolic effects on osteoblasts.

Methods

Osteophytes and cancellous bone obtained from human patients were transplanted onto the calvaria of severe combined immunodeficient mice, with Calcein administered intra-peritoneally for fluorescent labelling of bone mineralisation. Conditioned media were prepared using osteophytes and cancellous bone, and growth factor concentration and effects of each graft on proliferation, differentiation and migration of osteoblastic cells were assessed using enzyme-linked immunosorbent assays, MTS ((3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium)) assays, quantitative real-time polymerase chain reaction, and migration assays.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 403 - 411
1 Sep 2016
Mrosek EH Chung H Fitzsimmons JS O’Driscoll SW Reinholz GG Schagemann JC

Objectives

We sought to determine if a durable bilayer implant composed of trabecular metal with autologous periosteum on top would be suitable to reconstitute large osteochondral defects. This design would allow for secure implant fixation, subsequent integration and remodeling.

Materials and Methods

Adult sheep were randomly assigned to one of three groups (n = 8/group): 1. trabecular metal/periosteal graft (TMPG), 2. trabecular metal (TM), 3. empty defect (ED). Cartilage and bone healing were assessed macroscopically, biochemically (type II collagen, sulfated glycosaminoglycan (sGAG) and double-stranded DNA (dsDNA) content) and histologically.


Bone & Joint Research
Vol. 3, Issue 4 | Pages 130 - 138
1 Apr 2014
Shapiro F Connolly S Zurakowski D Flynn E Jaramillo D

Objectives

An experimental piglet model induces avascular necrosis (AVN) and deformation of the femoral head but its secondary effects on the developing acetabulum have not been studied. The aim of this study was to assess the development of secondary acetabular deformation following femoral head ischemia.

Methods

Intracapsular circumferential ligation at the base of the femoral neck and sectioning of the ligamentum teres were performed in three week old piglets. MRI was then used for qualitative and quantitative studies of the acetabula in operated and non-operated hips in eight piglets from 48 hours to eight weeks post-surgery. Specimen photographs and histological sections of the acetabula were done at the end of the study.