Radial head fractures are among the most common fractures around the elbow. Radial head arthroplasty is one of the surgical treatment options after complex radial head fractures. This surgery is usually done under
Orthopedic device-related infection (ODRI) preclinical models are widely used in translational research. Most models require induction of
Introduction and Objective. Wide awake local anaesthetic no tourniquet (WALANT) is being used for a wide variety of hand and wrist surgery. It has recently been used in distal radius fracture fixation. The purpose of this systematic review and meta-analysis was to assess the effectiveness of the WALANT technique in open reduction internal fixation. Materials and Methods. Pubmed, Embase, and Scopus databases were searched on 02/03/21 with the following search terms: radius, WALANT, local anesthetic, wide awake surgery. The primary outcome measure was conversion to general anaesthetic and mean intra-operative visual analogue scale (VAS) pain scores. Secondary measures were operative times, mean intraoperative blood loss, post-operative functional and radiological outcomes. Results. 110 articles were identified; eight studies were deemed eligible with 212 in the WALANT group and 247 in the comparative groups of regional
Abstract. Objective. To investigate the safety and cost-effectiveness of interscalene brachial plexus block/regional anaesthesia (ISB-RA) in patients undergoing reverse total shoulder replacement. Methods. This retrospective study included 15 patients with symptomatic rotator cuff arthropathy who underwent reverse total shoulder arthroplasty (rTSA) under ISB-RA without
Abstract. Objectives. Our objective was to determine the incidence of post-operative COVID-19 infection within the first two weeks following treatment at the COVID-free site. During the COVID-19 pandemic our hospital saw one of the highest rates of COVID-19 infection in the United Kingdom. As a result, our trauma services were relocated to a vacant private elective hospital to provide a ‘COVID-free’ setting for trauma patients. Patients admitted to the COVID-free site were screened for coronavirus infection and only treated at that site if asymptomatic. Those with symptoms were treated at the ‘COVID’ site. Method. We collected data at the COVID-free site during the first seven weeks of its’ establishment. Inclusion criteria were all patients presenting for operative management of limb trauma; however, fragility hip fractures were excluded. All patients were screened for symptoms of COVID-19 infection at their 2-week follow-up appointment. Results. 72 patients presented to our service during the study period. The mean age was 34.9 years (21 to 89). 62 patients had
The use of lumbar fusion procedures in the USA and Europe has rapidly increased over the last decade and a large number of these procedures involve the use of bone grafts. Despite of technical progress of spinal surgery and operative materials the risk of vertebral fusion failure occurs in 5 – 35 % of cases. Autografting has been considered the gold standard for bone graft procedures. However, the harvesting from the iliac crest can be associated with short and long-term morbidity in up to 22 % of cases. Main goal of this experimental study was to compare newly developed hybrid biodegradable nanocomposit porous implant (HBNPI) against bone craft from iliac crest as a new and better alternative for lumbar interbody fusion. 24 male pigs 4 months old weighting around 40 Kg were included in our study. These pigs were divided into two study groups depending on fusion method. Group A – 12 pigs underwent lateral lumbal interbody fusion (L2/3) with implantation of iliac crest bonegraft. Group B - 12 pigs underwent lateral lumbal interbody fusion (L2/3) with newly developed HBNPI. Each group were divided into two subgroups from these 6 spines were harvested 8 weeks (subgroup A1, B1) and 6 spines 16 weeks (group A2, B2) after surgery. After sacrifice, the lumbar spines were taking out and micro-CT, biomechanical testing and histomorphological analysis in all groups were performed to evaluate a quality of intervertebral fusion. As controls (group N), 6 cadaveric intact lumbar spines underwent biomechanical, micro-CT and histological testing. All 24 animals recovered from
Botulinum toxin A (BoNT-A) is a substance that requires repeated application due to its effectiveness being lost 12–16 weeks post application. Performing these intra-muscular injections under anesthesia reduces pain and distress during applications, ensuring effective and successful functional results. This study evaluates motor development of patients undergoing 3 or more repeated BoNT-A application in a tertiary pediatric hospital and the safety as well as effect of 3 different types of anesthesia. 75 children with cerebral palsy who underwent BoNT-A application at least three times consecutively with 6-month intervals and a total of 320 procedures admitted between January 2008 and January 2018 were retrospectively examined. Gross Motor Function Classification System (GMFCS) was employed in motor development evaluation. To observe the improvement in motor development, those with 2-1-0 level decreases in GMFCS classes were grouped and compared in terms of birth time, birth weight, cerebral palsy type and first BoNT-A application age. The 3 types of anesthesia methods (sedation analgesia, larengeal mask anesthesia (LMA) and inhalation mask anesthesia) applied during the procedures were compared in terms of sedation, procedure, recovery and total operation room time. The mean age of the children for all procedures was 45.51 ± 22.40 months. As a result of procedures, significant motor development was observed in 60 (80%) patients (p <0,000∗). No significant difference was observed when the children with cerebral palsy whose GMFCS declined in the form of level 2, 1 and unchanged were compared in terms of first application age, birth weight and gestational age. It was found that 106 (33.1%) were applied sevoflurane with anesthesia mask, 103 (32.1%) were administered sevoflurane with laryngeal mask, and 111 (34.6%) were sedation-analgesia. Only 10 out of 320 procedures were seen to develop side effects (8 vomiting, 2 bronchospasm). In the patients who underwent sedation analgesia during the first 3 BoNT-A procedures, the duration of recovery and total operating room time was seen to be significantly shorter than the others, while there was no difference between the anesthesia methods in the 4th and subsequent procedures. Regardless of the type of anesthesia, the recovery and total operating room times of those having undergone 6 or more procedures were longer than those with less than 6 procedures (p <0.009, p <0.016, respectively). As conclusion, repeated BoNT-A applications in children with CP provides progress in motor steps, it can be applied safely and effectively under anesthesia. Sedation analgesia application provides easier recovery compared to
Thermal osteonecrosis is a side effect when used Kirschner (K) wires and drills in orthopaedic surgeries. This osteonecrosis may endanger the fixation. Orthopaedic surgeons sometimes have to use unsharpened K-wires in emergent surgery. The thermal effect of used and unsharpened K wire is ambiguous to the bone. This experimental study aims to assess the thermal osteonecrosis while drilling bone with three different types of K-wires especially a previously used unsharpened wire and its thermographic measurements correlation. Two different speeds of rotation were chosen to investigate the effect of speed on thermal necrosis to the bone. A total of 16 New Zealand white rabbits weighing a mean of 2.90 kg (2.70 – 3.30 kg) were used. All rabbits were operated under
Implant infection is an increasing problem in orthopedic surgery, especially due to progressive antibiotic resistance and an aging population with rising numbers of implantations. As a consequence, new strategies for infection prevention are necessary. In the previous study it was hypothesized that laser-structured implant surfaces favor cellular adhesion while hindering bacterial ongrowth and therewith contribute to reduce implant infections. Cuboid titanium implants (0.8 × 0.8 × 12 mm. 3. , n=34) were used. Seventeen were laser-structured by ultra-short pulsed laser ablation to create a spike structure; the others were polished and served as controls. In
Summary Statement. Osteonecrosis of the femoral head (ONFH) is a multifactorial skeletal disorder. S100A9 represseses angiogenesis and vessel integrity in ONFH. It also may function as a marker of diagnosis in ONFH. Introduction. Osteonecrosis of the femoral head (ONFH) is a multifactorial skeletal disorder characterised by ischemic deterioration, bone marrow edema and eventually femoral head collapse and joint destruction. Several surgical, pharmaceutical and non-invasive biophysical modalities have been employed to alleviate this joint disorder. Our proteomic analysis showed that ONFH patients displayed increased expression of S100A9 protein when compared with healthy volunteers. This study is designed to evaluate the pathogenesis of S100A9 on the patients of ONFH. Patients & Methods. We collected 56 patients with ONFH including stage I, II, III and IV and 14 health volunteers. 20 ml of peripheral venous blood is drawn from each subject or prior to
We examined whether somatosensory evoked potentials (SEPs) were detectable after direct electrical stimulation of injured, reconstructed and normal anterior cruciate ligaments (ACL) during arthroscopy under
Regional anaesthetic for foot surgery has been discussed as a method of post operative analgesia. Ankle block as the sole anaesthetic for foot surgery has not been extensively reviewed in the literature. We aimed to describe our experience of forefoot surgery under ankle block. Sixty-six consecutive forefoot procedures (59 patients) were carried out under ankle block. Patients were contacted post operatively and completed a standardised questionnaire including an incremental pain assessment ranging from 0-10 (0 no pain, 10 severe pain). Forty nine female and 10 male patients (age range 20-85y) were included. Procedures included 33 first metatarsal osteotomies, 15 cheilectomies, 3 first MTP joint replacements, 5 fusions, 4 excision of neuroma and 6 other procedures. 22 patients (33% of cases) reported discomfort during the block procedure (average pain score 1.5). 6 patients reported pain during their operation(s), average score 0.26. Average pain scores at 6, 12, 24 and 48 hours following surgery were 2.0, 3.2, 2.7 and 2.1 respectively. All patients were discharged home and walking on the same day. There were no readmissions. Each patient confirmed they would have surgery under regional block rather than
Regional anaesthetic for foot surgery has been discussed as a method of post operative analgesia. Ankle block as the sole anaesthetic for foot surgery has not been extensively reviewed in the literature. We aimed to describe our experience of forefoot surgery under ankle block alone. 21 consecutive forefoot procedures (18 patients) were carried out under ankle block. The blocks were performed by the senior authors. A mixture of 10ml 2% Lidocaine with 10ml 0.5 % Bupivacaine was administered to the superficial peroneal, deep peroneal, sural and saphenous nerves. Ankle tourniquet was employed in all procedures. The patients were contacted post operatively and completed a standardised questionnaire including an incremented pain assessment ranging from 0-10 (0 no pain, 10 severe pain). 17 female and 1 male patients were contacted (age range 33-67y). Procedures included 13 first metatarsal osteotomies, 3 cheilectomies, 2 first MTP joint replacements, and 5 fusions. 14 patients requested a short acting sedative (midazolam). 5 patients (27 %) reported some discomfort during the block procedure (average pain score 1.2). No patients reported any pain during their operation(s). 4 patients (22%) required supplementation of the block. Average pain score at 6, 12, 24 and 48 hours following surgery were 0.66, 2.9, 2.4 and 1.3 respectively. All patients were discharged home and walking on the same day. None complained of nausea or required parenteral analgesia; there were no readmissions. Each patient confirmed they would have surgery under local block rather than
Summary. Our results prove that Demineralised Cortical Bone (DCB) can be used as biological tendon graft substitute, combined with correct surgical technique and the use of suture bone anchor early mobilisation can be achieved. Introduction. Surgical repair of tendon injuries aims to restore length, mechanical strength and function. In severe injuries with loss of tendon substance a tendon graft or a substitute is usually used to restore functional length. This is usually associated with donor site morbidity, host tissue reactions and lack of remodelling of the synthetic substitutes which may result in suboptimal outcome. In this study we hypothesise that DCB present in biological tendon environment with early mobilisation and appropriate tension will result in remodelling of the DCB into ligament tissue rather that ossification of the DCB at traditional expected. Our preparatory cadaveric study (abstract submitted to CORS 2013) showed that the repair model used in this animal study has sufficient mechanical strength needed for this animal study. Methods. 6 mature female sheep undergone surgical resection of the distal 1 cm of the right patellar tendon and osteotomy of patellar tendon attachment at the tibial tuberosity under
Summary Statement. Parathytorid hormone-related protein (107–111) loaded onto biopolymer-coated nanocrystalline hydroxyapatite (HA. Glu. ) improves the bone repair in a cavitary defect in rat tibiae. Introduction. Biopolymer-coated nanocrystalline hydroxyapatite (HA. Glu. ) made as macroporous foams are promising candidates as scaffolds for bone tissue engineering applications. They exhibit optimal features, promoting internalization, proliferation and differentiation of osteoprogenitors, with an adequate cell colonization over the entire scaffold surface. Parathyroid hormone-related protein (PTHrP) is an important modulator of bone formation. Its 107–111 epitope (osteostatin) exhibits osteogenic properties at least in part by directly acting on osteoblasts. The main aim of this study was to evaluate whether osteostatin loading into HA. Glu. scaffolds might improve their bone regeneration capacity. Materials and Methods. HA. Glu. scaffolds were prepared as previously described (Sánchez-Salcedo S et al. J. Mater. Chem. 2010; 20:6956-61). Osteostatin was adsorbed onto HA. Glu. material by dipping into a solution containing this peptide at 100 nM (in phosphate-buffered saline, pH 7.4), following a standard protocol. We performed a cavitary defect (2 mm in diameter and 3 mm in depth) in both distal tibial metaphysis using a drill under
Crown copyright 2009. Published with the (permission of the Defence Science and Technology Laboratory on behalf of the Controller of HMSO. Introduction. The optimum strategy for the care of war wounds is yet to be established. A need exists to model complex extremity injury, allowing investigation of wound management options. Aim. To develop a model of militarily relevant extremity wounding. Study Design. Laboratory study with New Zealand White Rabbits. Methods. Phase 1. Development of injury. Following induction of
To compare the therapeutic potential of tissue-engineered constructs (TECs) combining mesenchymal stem cells (MSCs) and coral granules from either Bone marrow-derived, autologous MSCs were seeded on Objectives
Materials and Methods
Osteophytes are products of active endochondral and intramembranous ossification, and therefore could theoretically provide significant efficacy as bone grafts. In this study, we compared the bone mineralisation effectiveness of osteophytes and cancellous bone, including their effects on secretion of growth factors and anabolic effects on osteoblasts. Osteophytes and cancellous bone obtained from human patients were transplanted onto the calvaria of severe combined immunodeficient mice, with Calcein administered intra-peritoneally for fluorescent labelling of bone mineralisation. Conditioned media were prepared using osteophytes and cancellous bone, and growth factor concentration and effects of each graft on proliferation, differentiation and migration of osteoblastic cells were assessed using enzyme-linked immunosorbent assays, MTS ((3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium)) assays, quantitative real-time polymerase chain reaction, and migration assays.Objectives
Methods
We sought to determine if a durable bilayer implant composed of trabecular metal with autologous periosteum on top would be suitable to reconstitute large osteochondral defects. This design would allow for secure implant fixation, subsequent integration and remodeling. Adult sheep were randomly assigned to one of three groups (n = 8/group): 1. trabecular metal/periosteal graft (TMPG), 2. trabecular metal (TM), 3. empty defect (ED). Cartilage and bone healing were assessed macroscopically, biochemically (type II collagen, sulfated glycosaminoglycan (sGAG) and double-stranded DNA (dsDNA) content) and histologically.Objectives
Materials and Methods
An experimental piglet model induces avascular necrosis (AVN)
and deformation of the femoral head but its secondary effects on
the developing acetabulum have not been studied. The aim of this
study was to assess the development of secondary acetabular deformation
following femoral head ischemia. Intracapsular circumferential ligation at the base of the femoral
neck and sectioning of the ligamentum teres were performed in three
week old piglets. MRI was then used for qualitative and quantitative
studies of the acetabula in operated and non-operated hips in eight
piglets from 48 hours to eight weeks post-surgery. Specimen photographs and
histological sections of the acetabula were done at the end of the
study. Objectives
Methods