C. Difficile infections in elderly patients with hip fractures is associated with high morbidity and mortality. Antibiotic regimens with penicillin and its derivatives is a leading cause. Antibiotic prophylactic preferences vary across different hospitals within NHS. We compared two antibiotic prophylactic regimens - Cefuroxime only prophylaxis and Teicoplanin with Gentamicin prophylaxis in
Prompt mobilisation after the
Total hip replacement (THR) is an option in a subset of patients with a
The Royal College of Surgeons of England (RCS) Good Surgical Practice guidance identifies essential criteria for surgical operation note documentation. The current quality improvement project aims to identify if using pre-templated operation notes for documenting
Abstract. BACKGROUND. Hemi-arthroplasty (HA) as a treatment for
Abstract. Objectives. Hip instability following total hip arthroplasty in treatment of intracapsular
Background. Fractured neck of femurs cause substantial morbidity and mortality in elderly patients and represent a huge financial burden to the NHS. Hip fracture patients are generally malnourished on admission, often having poor nutritional inpatient intake, hindering recovery and increasing chances of “unfavourable outcome.” Nutritional care is included in intercollegiate guidelines for management of
Introduction. Prosthetic joint infection (PJI) is an uncommon but serious complication of hip replacement. A recent systematic review of patient risk factors for PJI identified male gender, smoking status, increasing BMI, steroid use, previous joint surgery and comorbidities of diabetes, rheumatoid arthritis and depression as risk factors for developing PJI. Limitations of the current literature include the short term follow up of most published studies. We investigated the role of patient, surgical and healthcare factors on the risk of revision of a primary hip replacement for PJI at different time-points in the post-operative follow-up. It is important that those risk factors are identified so that patients can be appropriately counselled according to their individual risk profile prior to surgery and modifiable factors can be addressed to reduce the risk of PJI at an individual and healthcare system level. Materials and Methods. Primary hip replacements and subsequent revision procedures performed for PJI from 2003–2014 were identified from the National Joint Registry (NJR). Patient (age, gender, ASA grade, BMI), perioperative (surgical indication, type of anaesthesia, thromboprophylaxis regime, surgical approach, hip replacement and bearing surface and use of femoral or acetabular bone graft) and healthcare system characteristics (surgeon grade, surgical volume) were linked with data from Hospital Episode Statistics to obtain information on specific ethnicity and comorbidities (derived from the Charlson index). Multilevel piecewise exponential non-proportional hazards models were used to estimate their effects at different post-operative periods (0–3 months, 3–6 months, 6–12 months, 12–24 and >24 months post-operation). Results. The index hip replacements consisted of 623,253 primaries with 2,705 subsequently revised for PJI, 14% within 3 months, 8% between 3–6 months, 14% between 6–12 months, 22% between 1–2 years and 42% ≥2 years after the index procedure. Risk factors for revision of PJI included male gender, high BMI, high ASA grade and younger age. Their effects were period-specific. Patients with chronic pulmonary disease, diabetes or dementia had high early risk of revision for PJI, as did patients operated for a
To report the case of an asymptomatic simultaneous bilateral
Recent NICE guidance recommends use of a well proven cemented femoral stem for hip hemiarthroplasty in management of
Hip fracture is a common and serious injury affecting the elderly. Many patients have co-morbidities which may need to be investigated and treated before surgery but, conversely, delay in surgical management of these patients leads to increased morbidity and mortality. The Scottish Hip Fracture Audit (SHFA). 1. conducted in 2007 showed variations between hospitals in postponement rates for medical reasons. The report referred to 11 major clinical abnormalities described by McLaughlin. 2. that were associated with poor postoperative outcomes and should be corrected before surgery. This prospective audit took place in Monklands hospital for a duration of 6 weeks. All patients admitted to the orthopaedic firm from 14. th. Oct 2012 to 26. th. November 2012 with confirmed
Currently, the cement being used for hemiarthroplasties and total hip replacements by the authors and many other surgeons in the UK is Palacos® (containing 0.5g Gentamicin). Similar cement, Copal® (containing 1g Gentamicin and 1g Clindamycin) has been used in revision arthroplasties, and has shown to be better at inhibiting bacterial growth and biofilm formation. We aim to investigate the effect on SSI rates of doubling the gentamicin dose and adding a second antibiotic (clindamycin) to the bone cement in hip hemiarthroplasty. We randomised 848 consecutive patients undergoing cemented hip hemiarthroplasty for fractured NOF at one NHS trust (two sites) into two groups: Group I, 464 patients, received standard cement (Palacos®) and Group II, 384 patients, received high dose, double antibiotic-impregnated cement (Copal®). We calculated the SSI rate for each group at 30 days post-surgery. The patients, reviewers and statistician were blinded as to treatment group. The demographics and co-morbid conditions (known to increase risk of infection) were statistically similar between the groups. The combined superficial and deep SSI rates were 5 % (20/394) and 1.7% (6/344) for groups I and II respectively (p=0.01). Group I had a deep infection rate 3.3 %(13/394) compared to 1.16% (4/344) in group II (p=0.082). Group I had a superficial infection rate 1.7 % (7/394) compared to 0.58% (2/344) in group II (p=0.1861). 33(4%) patients were lost to follow up, and 77 (9%) patients were deceased at the 30 day end point. There was no statistical difference in the 30 day mortality, C. difficile infection, or the renal failure rates between the two groups. Using high dose double antibiotic-impregnated cement rather than standard low dose antibiotic-impregnated cement significantly reduced the SSI rate (1.7% vs 5%; p=0.01) after hip hemiarthroplasty for
Osteoporosis (OP) results in a reduction in the mechanical competence of the bone tissue of the sufferers. In skeletal sites such as the proximal femur and the vertebrae, OP manifests itself in low trauma fragility fractures which are debilitating for the patient. The relationships between the compressive strength of cancellous tissue and its apparent density are well established in studies of the past. Recently the authors have presented a method able to assess the fracture toughness properties of cancellous bone (1), a challenging cellular material which can exhibit large elasto-plastic deformations. The in-vitro measurement of fracture toughness alongside the customary compressive strength can provide a comprehensive assessment of the mechanical capacity of cancellous bone, which will reflect closer its ability to resist crack initiation. The aims of the present study were: (1) to examine whether the observed fracture toughness deterioration can also be detected by non-invasive quantitative ultrasound (QUS); and (2) to provide rational evidence for the well proven ability of QUS to predict directly ‘risk of fracture’. 20 femoral heads were obtained from donors undergoing emergency surgery for a
Despite the development of skeletal or mesenchymal stem cell (MSC) constructs aimed at creating viable cartilage and bone, few studies have examined the effects of cytokines present in rheumatoid arthritis (RA) and osteoarthritis (OA) synovial tissues, or inhibition of these, on such constructs. This work addresses these issues using both in vitro and in vivo approaches and examines potential ways of overcoming the effects of cytokines on the integrity of cartilage and bone constructs. Synovial samples were obtained from RA or OA (n=10) patients undergoing elective hip or knee arthroplasty at Southampton General Hospital. Full ethical approval was obtained. Control bone marrow-derived stromal cells were obtained from patients undergoing emergency
Bone related adverse events including failure of implant osseo-integration, periprosthetic
The renewed interest in the clinically proven low wear of the metal-on-metal bearing combined with the capacity of inserting a thin walled cementless acetabular component has fostered the reintroduction of hip resurfacing. As in other forms of conservative hip surgery, i.e. pelvic osteotomies and impingement surgery, patient selection will help minimize complications and the need for early reoperation. Patient Selection and Hip Resurfacing. Although hip resurfacing was initially plagued with high failure rates, the introduction of metal on metal bearings as well as hybrid fixation has shown excellent survivorships of 97 to 99% at 4 to 5 years follow-up. However, it is important to critically look at the initial published results. In all of these series there was some form of patient selection. For example, in the Daniel and associates publications, only patients with osteoarthritis with an age less than 55 were included with 79% of patients being male. Treacy and associates stated that: “the operation was offered to men under the age of 65 years and women under the age of 60 years, with normal bone stock judged by plain radiographs and an expectation that they would return to an active lifestyle, including some sports”. However in the materials and methods, although the mean age is 52 years, the range is from 17 to 76 years including some patients with rheumatoid arthritis as well as osteonecrosis. Obviously, some form of patient selection is needed; but how one integrates them is where the Surface Arthroplasty Risk Index (SARI) is useful. With a maximum score of 6, points are assigned accordingly: femoral head cyst >1cm: 2 points; patient weight <82kg: 2 points; previous hip surgery: 1 point; UCLA Activity level >6: 1 point. A SARI score >3 represented a 4 fold increase risk in early failure or adverse radiological changes and with a survivorship of 89% at four years. The SARI index also proved to be relevant in assessing the outcome of the all cemented McMinn resurfacing implant (Corin¯, Circentester, England) at a mean follow-up of 8.7 years. Hips which had failed or with evidence of radiographic failure on the femoral side had a significantly higher SARI score than the remaining hips, 3.9 versus 1.9. Finally, one must consider the underlying diagnosis when evaluating a patient for hip resurfacing. In cases of dysplasia, acetabular deficiencies combined with the inability of inserting screws through the acetabular component may make initial implant stability unpredictable. This deformity in combination with a significant leg length discrepancy or valgus femoral neck could compromise the functional results of surface arthroplasty, and in those situations a stem type total hip replacement may provide a superior functional outcome. In respect to other diagnoses (osteonecrosis, inflammatory arthritis), initial analyses have not demonstrated any particular diagnostic group at greater risk of earlier failure. The only reservation we have is in patients with compromised renal function since metal ions generated from the metal-on-metal bearing are excreted through the urine and the lack of clearance of these ions may lead to excessive levels in the blood. Surgical Technique. Because resurfacing has not been within the training curriculum of orthopaedic surgeons for the last 2 decades, there will most likely be a learning curve in the integration of this implant within clinical practice. This data was confirmed for hip resurfacing when looking at the Canadian Academic Experience where in the first 50 cases of five arthroplasty surgeons only a 3.2% failure rate was noted of which 1.6% were due to neck
Maintaining femoral neck cortical thickness may help prevent hip fracture. Fracture initiation probably starts superiorly at flaws, ie where the cortex is thinnest. Whole body computed tomography (QCT) is now being used to study cortical thickness but limited resolution (> 300 micrometers) makes in vivo estimates imprecise, whereas microscopy s resolution approaches 1 micrometer. We have therefore extended our microscopic studies on femoral neck biopsies to include men (14 cases, 26 controls) and women (50 cases, 23 controls), and here provide data on true cortical thickness in subjects with and without hip