Aims. Total
Aims. The aim of this study was to investigate the rate of revision for distal
Aims. Endoprosthetic reconstruction with a distal
Aims. Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal
There is a paucity of data available for the use of Total
Aims. The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal
The December 2023 Trauma Roundup. 360. looks at: Distal
Patellofemoral replacement is an established intervention in selected patients with severe isolated patellofemoral osteoarthritis. FPV (Wright Medical, UK) is a third generation patellofemoral arthroplasty implant and is the second most used after AVON in National Joint Registry for England and Wales. Reports of survivorship and functional of this implant are scarce in literature. Evaluation of functional outcome and survivorship following FPV patellofemoral arthroplasty.Background
Aim
Isolated patellofemoral arthritis occurs in up to 10% of patients suffering osteoarthritis of the knee. Previous reports of several different patellofemoral designs have given indifferent results. The Lubinus prosthesis has been shown to have a 50% failure rate at eight years in a study of 76 cases. The main reasons for failure were mal-alignment, wear, impingement and disease progression. As a result of these studies, a new prosthesis was designed to solve some of these problems. The Avon patellofemoral arthroplasty was first implanted in September 1996. The cases have been entered into a prospective review with evaluations at eight months, two years and five years. The outcome was assessed using pain scores, Bartlett’s patella score and the Oxford knee score. To date, 186 knees have been treated; over 100 knees have been reviewed at two years and 20 knees at five years. The main pain score improved from a pre-operative level of 13.5 points out of 40 to 33.5 points at two years and 36 at five years. The mean pre-operative movement was 109° and this increased to 120° at five years. The Bartlett patella score improved from a pre-operative level of 10.5 points out of 30 pre-operatively to 23 points at two years and 25 at five years. The Oxford knee score was 20 points out of 48 pre-operatively and this improved to 35 points at two years and 40 points at five years. One patient developed subluxation, which required distal soft tissue realignment. No other patient has developed problems with alignment or wear. Ten knees have developed evidence of disease progression usually in the medial compartment of which six have required revision to a total knee replacement. The results to date suggest that this improved design has all but eliminated the previous problems of malalignment and early wear. The functional results are as good or better than those of a total knee replacement. There is a low complication rate and an excellent range of movement. Disease progression remains a potential problem. This type of prosthesis offers a reasonable alternative to total knee replacement in this small group of patients with isolated, early patellofemoral disease.
Comparison of two cementing techniques: femoral component insertion into early-cure stage cement and insertion into late-cure stage cement in an in vivo model to identify if cement cure stage affects the strength of the bone cement interface. Bilateral arthroplasties – using only the femoral component - were performed in vivo on paired porcine femora. The femora were harvested and cross-sectioned in preparation for strength testing. Performance was measured by peak load required to push the femoral prosthesis and surrounding cement mantle free of the cancellous bone. The mean failure load for prostheses inserted into late cure stage cement was 908 N +/− SD 420, whereas the mean failure load for the conjugate early cure stage cement was 503 N +/− SD 342. A paired t-test indicated significantly higher load failure rates in the late cure stage cement versus the early cure stage samples (t=2.37, p<
0.049). Femoral component insertion into late cure stage cement required statistically significant higher loads for push-out when compared to femoral component insertion into early cure stage cement.
Aims. Debate continues regarding the optimum management of periprosthetic distal femoral fractures (PDFFs). This study aims to determine which operative treatment is associated with the lowest perioperative morbidity and mortality when treating low (Su type II and III) PDFFs comparing lateral locking plate fixation (LLP-ORIF) or distal
Aims. The prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFFs). Our study aimed to assess treatment methodologies, implant survivorship, and IPFF clinical outcomes. Methods. A total of 76 patients treated for an IPFF from February 1985 to April 2018 were reviewed. Prior to fracture, at the hip/knee sites respectively, 46 femora had primary/primary, 21 had revision/primary, three had primary/revision, and six had revision/revision components. Mean age and BMI were 74 years (33 to 99) and 30 kg/m. 2. (21 to 46), respectively. Mean follow-up after fracture treatment was seven years (2 to 24). Results. Overall, 59 fractures were classified as Vancouver C (Unified Classification System (UCS) D), 17 were Vancouver B (UCS B). In total, 57 patients (75%) were treated with open reduction and internal fixation (ORIF); three developed nonunion, three developed periprosthetic joint infection, and two developed aseptic loosening. In all, 18 patients (24%) underwent revision arthroplasty including 13 revision THAs, four distal
Introduction. The management of peri-prosthetic distal femur fractures following TKR (Total Knee Replacement) in the elderly remains a challenge with little or no consensus on the best available treatment. Various methods have been described in the management of these complex fractures. Our study compares the outcome and cost of distal
Aims. To achieve the functional benefits of the direct anterior (DA) approach and the fixation benefits of cemented replacement, this study combined the two techniques posing the following questions: does the limited access of the DA approach adversely affect the cement technique?; and does such a cementing technique reduce the incidence of cementless complications?. Methods. A consecutive series of 341 patients (360 hips) receiving the DA approach between 2016 and 2018 were reviewed. There were 203 cementless stems and 157 cemented stems. Mean age was 75 years (70 to 86) in the cementless group and 76 years (52 to 94) in the cemented group, with 239 (70%) females in the whole series. Femoral complications were compared between the two groups. Mean follow-up was 1.5 years (0.1 to 4.4) for patients in the cementless group and 1.3 years (0.0 to 3.9) for patients in the cemented group. Results. The cementless group had a higher rate of femoral complications (8 vs 0; p = 0.011). There were two loose stems and six fractures, all requiring revision. Fractures occurred a mean 14.5 days (2 to 31) postoperatively and loosening at 189 days and 422 days postoperatively. Femoral cementing can be done using the DA approach safely and reduces the number of complications compared with a contemporary cementless series. Conclusion. A higher rate of early fractures and loosening occurred with cementless stems. This was not observed in our cemented stem cohort and cementing was safely accomplished through the DA approach. The modern femoral cementing process with the DA approach does not add to surgical complexity or time, has fewer early complications, and is a safer option for older patients compared to cementless
Aims. Limb salvage in bone tumour patients replaces the bone with massive segmental prostheses where achieving bone integration at the shoulder of the implant through extracortical bone growth has been shown to prevent loosening. This study investigates the effect of multidrug chemotherapy on extracortical bone growth and early radiological signs of aseptic loosening in patients with massive distal femoral prostheses. Methods. A retrospective radiological analysis was performed on adult patients with distal
Aims. We have evaluated the survivorship, outcomes, and failures of an interlocking, reconstruction-mode stem-sideplate implant used to preserve the native hip joint and achieve proximal fixation when there is little residual femur during large endoprosthetic reconstruction of the distal femur. Methods. A total of 14 patients underwent primary or revision reconstruction of a large femoral defect with a short remaining proximal femur using an interlocking, reconstruction-mode stem-sideplate for fixation after oncological distal femoral and diaphyseal resections. The implant was attached to a standard endoprosthetic reconstruction system. The implant was attached to a standard endoprosthetic reconstruction system. None of the femoral revisions were amenable to standard cemented or uncemented stem fixation. Patient and disease characteristics, surgical history, final ambulatory status. ,. and Musculoskeletal Tumor Society (MSTS) score were recorded. The percentage of proximal femur remaining was calculated from follow-up radiographs. Results. All 14 at-risk native hip joints were preserved at a mean final follow-up of 6.0 years (SD 3.7), despite a short residual femur, often after proximal osteotomies through the lesser trochanter. Overall, 13 of 14 stems had long-term successful fixation. Eight patients required no reoperation. Three patients required reoperation due to implant-related issues, and three patients required reoperation for wound healing problems or infection. There were no dislocations or fractures. At final follow-up the mean MSTS score was 24.9 (SD 4.1). Nine patients required no ambulation aids, and only one had a Trendelenburg gait. Conclusion. This interlocking, reconstruction-mode stem-sideplate reliably preserves native hip joint anatomy and function after large femoral resection with a short remaining proximal femur, both in the primary and revision setting. This is particularly important for preventing or delaying total
Over the past 30 years there have been many improvements
in implant fixation, correction of deformity, improved polyethylene
wear, and survival after knee replacement. The work over the last
decade has focused on less invasive surgical techniques, multimodal
pain management protocols, more rapid functional recovery and reduced
length of stay, aiming to minimise the side effects of treatment
while maintaining function and implant durability. When combined
and standardised these pre-, intra- and post-operative factors have
now facilitated outpatient knee replacement procedures for unicompartmental
replacement, patella
Purpose:. Biomechanical knowledge of the medial collateral ligament (MCL) is important for MCL release during knee arthroplasty. The purpose of this study was to define the influences of the deep medial collateral ligament (dMCL) and the posterior oblique ligament (POL) on valgus and rotatory stability in knee arthroplasty. Methods:. Six cadaveric knees were divided into 2 groups with unique sequential sectioning sequences of the dMCL and the POL. Group A (n = 2) first received
The aim of this study was to report our experience of patellofemoral arthroplasty in isolated osteoarthrosis. Material and Methods: The Lubinus Patellofemoral Arthroplasty was performed between 1989 and 1995 in 76 knees. The Avon Patella
Periprosthetic femoral fractures are increasing in incidence, and typically occur in frail elderly patients. They are similar to pathological fractures in many ways. The aims of treatment are the same, including 'getting it right first time' with a single operation, which allows immediate unrestricted weightbearing, with a low risk of complications, and one that avoids the creation of stress risers locally that may predispose to further peri-implant fracture. The surgical approach to these fractures, the associated soft-tissue handling, and exposure of the fracture are key elements in minimizing the high rate of complications. This annotation describes the approaches to the femur that can be used to facilitate the surgical management of peri- and interprosthetic fractures of the femur at all levels using either modern methods of fixation or revision arthroplasty. Cite this article: