header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 34 - 34
1 Oct 2016
Steinberg J Shah K Gartland A Zeggini E Wilkinson J
Full Access

Systemic concentrations of metal ions (cobalt and chromium) are persistently elevated in patients with metal-on-metal hip resurfacing (MOMHR) compared to conventional total hip arthroplasty (THA). Several studies by us and others have described the detrimental effects of metal exposure on survival and function of various cell types in-vitro, but the mechanisms for these effects remain unclear. Epigenetic modifications following chronic metal exposure is a possible mechanism that could mediate these effects. Here we test the methylation status in genomic DNA from MOMHR (“cases”) and THA (“controls”) patient-groups, and its correlation with circulating metal levels. The cohort consisted of 34 patients with a well-functioning MOMHR at a median follow-up of 9.75 years. These were individually matched for gender, age and time-since-surgery to a non-exposure group consisting of patients with THA. Genomic DNA was isolated from blood samples and cell composition estimated using the ‘estimateCellCounts’ function in ‘minfi R-package’. Methylation was assessed using the Illumina 450k BeadChip array analysing 426,225 probes. Logit model was fitted at each probe with case/control status as independent variable and covariates of gender, age, time-since-surgery, smoking, non-arthroplasty metal exposure, and cell composition. DNA methylation age was assessed using an online calculator (. https://dnamage.genetics.ucla.edu/. ) and comparisons made between cases and controls, and correlated with circulating metal levels. Cell distributions did not differ between the cases and controls (Wilcoxon test p<0.17) with no probe having an association at 5% FDR. Circulating metal levels and LVEDD also had no association with any probe at 5% FDR. There was no preferential age acceleration between cases and controls (Wilcox p<0.7), and it had no correlation with plasma-chromium or blood-cobalt levels (p<0.9). In summary, large methylation changes following MOMHR seem to be absent, compared to THA. Future research with larger samples will be needed to clarify the presence and extent of small methylation changes


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 119 - 119
1 Aug 2012
Kumar KS Jaiswal A Gilbert R Carrothers A Kuiper J Richardson J
Full Access

Background. Hip resurfacing has resurged in the last decade due to a renewed interest in metal on metal bearing. One of the proposed advantages is ease of revision of the femoral component. Short term functional results after femoral revision are similar to those after conventional total hip replacement. Survival and function after revision of the acetabular component only or of both components have not been reported. We aimed to assess hip function and implant survival after revision of the acetabular component for failed Birmingham hip resurfacing (BHR). Methods. The Oswestry Outcome Centre collected data prospectively on 5000 patients who underwent hip resurfacing between 1997 and 2002. Of these, 182 hips were revised: 42% had revision of the femoral component only, 8% revision of the acetabular component only, and 50% revision of both components. This study analyzed patients who had revision of the acetabular component, either in isolation or in combination with the femoral component. Results. In the isolated acetabular revision group the median Harris Hip Score was 74 at a mean of 4.5 years post-revision. In the both components revision group the median Harris hip score was 85 at a mean of 4 years. There was no significant difference in function between the groups. Kaplan-Meier survivor ship analysis after revision showed an average survival of 91% at 10 years. There was a significant difference between survival of isolated acetabular revision (75%) and both component revision (96%). Conclusions. Revision total hip replacement subsequent to failure of hip resurfacing has good outcome and good midterm survival. Isolated acetabular revision and revision of both components had similar function but survival was significantly worse in the isolated acetabular revision group


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 124 - 130
1 Jan 2009
Deuel CR Jamali AA Stover SM Hazelwood SJ

Bone surface strains were measured in cadaver femora during loading prior to and after resurfacing of the hip and total hip replacement using an uncemented, tapered femoral component. In vitro loading simulated the single-leg stance phase during walking. Strains were measured on the medial and the lateral sides of the proximal aspect and the mid-diaphysis of the femur. Bone surface strains following femoral resurfacing were similar to those in the native femur, except for proximal shear strains, which were significantly less than those in the native femur. Proximomedial strains following total hip replacement were significantly less than those in the native and the resurfaced femur.

These results are consistent with previous clinical evidence of bone loss after total hip replacement, and provide support for claims of bone preservation after resurfacing arthroplasty of the hip.