Advertisement for orthosearch.org.uk
Results 1 - 20 of 180
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 2 | Pages 305 - 311
1 May 1963
Hargadon EJ Pearson JR

1. A series of 100 intracapsular fractures of the femoral neck treated with the Charnley compression screw is reported. 2. There were six deaths, and in patients reviewed long enough (seventy-five) there were eleven undisplaced fractures, with successful union in 8l·8 per cent, and sixty-four displaced fractures, with a union rate of 59·6 per cent. 3. If we exclude six failures of operative technique, there remain fifty-eight patients in whom the fracture was judged radiologically to have united in 65·5 per cent. 4. The Charnley compression screw is an effective method of internal fixation in such fractures, and non-union with this method is usually due to causes other than mechanical failure


We evaluated the outcome of treatment of nonunion of an intracapsular fracture of the femoral neck in young patients using two cannulated screws and a vascularised bone graft. A total of 32 patients (15 women and 17 men, with a mean age of 36.5 years; 20 to 50) with failed internal fixation of an intracapsular fracture were included in the study. Following removal of the primary fixation, two cannulated compression screws were inserted with a vascularised iliac crest bone graft based on the ascending branch of the lateral femoral circumflex artery. At a mean follow-up of 6.8 years (4 to 10), union was achieved in 27 hips (84%). A total of five patients with a mean age of 40.5 years (35 to 50) had a persistent nonunion and underwent total hip arthroplasty as also did two patients whose fracture united but who developed osteonecrosis of the femoral head two years post-operatively. Statistical analysis showed that younger patients achieved earlier and more reliable union (p < 0.001). The functional outcome, as assessed by the Harris Hip score, was better in patients aged < 45 years compared with those aged > 45 years (p < 0.001). . These findings suggest that further fixation using two cannulated compression screws and a vascularised iliac crest bone graft is an effective salvage treatment in patients aged <  45 years, in whom osteosynthesis of a displaced intracapsular fractures of the femoral neck has failed. Cite this article: Bone Joint J 2015; 97-B:988–91


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 9 - 9
1 Jul 2016
Jawalkar H Aggarwal S Bilal A Oluwasegun A Tavakkolizadeh A Compson J
Full Access

Scaphoid fractures accounts for approximately 15% of all fractures of hand and wrist. Proximal pole fractures represent 10–20% of scaphoid fractures. Non –operative treatment shows high incidence of non-union and avascular necrosis. Surgical intervention with bone graft is associated with better outcome. The aim of this study was to evaluate the radiological and functional outcome of management of proximal pole scaphoid non-union with internal fixation and bone grafting. We included 35 patients with proximal pole scaphoid non-union (2008–2015). All patients underwent antegrade headless compression screw fixation and bone grafting at King's College Hospital, London (except one, who was fixed with Kirschner wire). 33 patients had bone graft from distal radius and two from iliac crest. Postoperatively patients were treated in plaster for 6–8 weeks, followed by splinting for 4–6 weeks and hand physiotherapy. All the patients were analysed at the final follow-up using DASH score and x-rays. Mean age of the patients was 28 years (20–61) in 32 men and 3 women. We lost three patients (9%) to follow up. At a mean follow up of 16 weeks (12–18) twenty three patients (66%) achieved radiological union. All patients but three (91%) achieved good functional outcome at mean follow up of 14 weeks (10–16). A good functional outcome can be achieved with surgical fixation and bone graft in proximal pole scaphoid fractures non-union. Pre-operative fragmentation of proximal pole dictates type of fixation (screw or k wire or no fixation). There was no difference in outcome whether graft was harvested from distal radius or iliac crest


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 703 - 708
1 Jun 2022
Najefi A Zaidi R Chan O Hester T Kavarthapu V

Aims. Surgical reconstruction of deformed Charcot feet carries a high risk of nonunion, metalwork failure, and deformity recurrence. The primary aim of this study was to identify the factors contributing to these complications following hindfoot Charcot reconstructions. Methods. We retrospectively analyzed patients who underwent hindfoot Charcot reconstruction with an intramedullary nail between January 2007 and December 2019 in our unit. Patient demographic details, comorbidities, weightbearing status, and postoperative complications were noted. Metalwork breakage, nonunion, deformity recurrence, concurrent midfoot reconstruction, and the measurements related to intramedullary nail were also recorded. Results. There were 70 patients with mean follow-up of 54 months (SD 26). Overall, 51 patients (72%) and 52 patients (74%) were fully weightbearing at one year postoperatively and at final follow-up, respectively. The overall hindfoot union rate was 83% (58/70 patients). Age, BMI, glycated haemoglobin, and prior revascularization did not affect union. The ratio of nail diameter and isthmus was greater in the united compared to the nonunited group (0.90 (SD 0.06) and 0.86 (SD 0.09), respectively; p = 0.034). In those with a supplementary hindfoot compression screw, there was a 95% union rate (19/20 patients), compared to 78% in those without screws (39/50 patients; p = 0.038). All patients with a miss-a-nail hindfoot compression screw went on to union. Hindfoot metalwork failure was seen in 13 patients (19%). An intact medial malleolus was found more frequently in those with intact metalwork ((77% (44/57 patients) vs 54% (7/13 patients); p = 0.022) and in those with union ((76% (44/58 patients) vs 50% (6/12 patients); p = 0.018). Broken metalwork occurred more frequently in patients with nonunions (69% (9/13 patients) vs 9% (5/57 patients); p < 0.001) and midfoot deformity recurrence (69% (9/13 patients) vs 9% (5/57 patients); p < 0.001). Conclusion. Rates of hindfoot union and intact metalwork were noted in over 80% of patients. Union after hindfoot reconstruction occurs more frequently with an isthmic fit of the intramedullary nail and supplementary hindfoot screws. An intact medial malleolus is protective against nonunion and hindfoot metalwork failure. Cite this article: Bone Joint J 2022;104-B(6):703–708


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims. Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs). Methods. In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years. Results. Mean follow-up was 4.6 years (4.1 to 5.0) in the CCS group and 5.5 years (5.25 to 5.75) in the VOOF group. The mean Harris Hip Score at two-year follow-up was 83.85 in the CCS group versus 88.00 in the VOOF group (p < 0.001). At the latest follow-up, all-cause failure rate was 29.1% in the CCS group and 11.7% in the VOOF group (p = 0.003). The total cost of the VOOF technique was 7.2% of a THA, and total cost of the CCS technique was 6.3% of a THA. Conclusion. The VOOF technique decreased all-cause failure rate compared to CCS. The total cost of VOOF was 13.5% greater than CCS, but 92.8% less than a THA. Increased cost of VOOF was considered acceptable to all patients in this series. VOOF technique provides a reasonable alternative to THA in patients who cannot afford a THA procedure. Cite this article: Bone Jt Open 2023;4(5):329–337


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 146 - 146
1 May 2011
Klos K Windolf M Boyko G Schwieger K Hofmann G Mückley T
Full Access

Background: Lapidus (first metatarsocuneiform joint) arthrodesis is an established procedure for the management of hallux valgus. This study investigated the utility of fixation with a medial locking plate with adjunct compression screw versus fixation with two crossed screws. Methods: Eight pairs of fresh-frozen human specimens were used in a matched paired test. Bone mineral density (BMD) was measured with peripheral quantitative computed tomography (pQCT). Fixation with two 4-mm-diameter crossed screws was compared versus a medial locking plate (X-Locking Plate 2.4/2.7; Synthes, Solothurn, Switzerland) with adjunct 4-mm-diameter compression screw. The specimens tested in a four-point bending test. Parameters obtained were initial stiffness; plantar joint-line gapping after one cycle, 100 and 1000 cycles; and number of cycles to failure. Failure was defined as ≥ 3 mm plantar gapping displacement. Results: The groups did not differ significantly with regard to BMD (p = 0.866) and initial stiffness (p = 0.889). The plate-and-screw construct showed significantly less movement during testing, and significantly (p = 0.001) more cycles to failure than did the crossed-screw construct. There was a significant correlation (crossed-screw construct: p = 0.014; plate-and-screw construct: p = 0.010) between BMD and the number of cycles to failure. Conclusions: Under cyclic loading conditions, the construct using a medial locking plate with adjunct compression screw was superior to the construct using two crossed screws. Clinical Relevance: The medial locking-plate technique described holds promise for shortening the time off weight-bearing and for reducing the risk of non-union


There is a high risk of the development of avascular necrosis of the femoral head and nonunion after the treatment of displaced subcapital fractures of the femoral neck in patients aged < 50 years. We retrospectively analysed the results following fixation with two cannulated compression screws and a vascularised iliac bone graft. We treated 18 women and 16 men with a mean age of 38.5 years (20 to 50) whose treatment included the use of an iliac bone graft based on the ascending branch of lateral femoral circumflex artery. There were 20 Garden grade III and 14 grade IV fractures. Clinical and radiological outcomes were evaluated. The mean follow-up was 5.4 years (2 to 10). In 30 hips (88%) union was achieved at a mean of 4.4 months (4 to 6). Nonunion occurred in four hips (12%) and these patients had a mean age of 46.5 years (42 to 50) and underwent revision to a hip replacement six months after operation. The time to union was dependent on age with younger patients achieving earlier union (p < 0.001). According to the Harris hip score which was available for 27 of the 30 hips with satisfactory union, excellent results were obtained in 15 (score ≥ 90 points), fair in ten (score 80 to 90 points), and poor in two hips (≤ 80 points). One patient aged 48 years developed avascular necrosis of femoral head six years after operation and underwent total hip replacement. The management of displaced subcapital fractures of the femoral neck, in patients aged <  50 years, with two cannulated compression screws and an iliac bone graft based on the ascending branch of lateral femoral circumflex artery, gives satisfactory results with a low rate of complication including avascular necrosis and nonunion. Cite this article: Bone Joint J 2014;96-B:1024–8


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 27 - 27
1 May 2012
Oddy M Konan S Meswania J Blunn G Madhav R
Full Access

Medial Displacement Osteotomy (MDO) of the os calcis is used to correct the hind foot valgus in a flat foot deformity. Screw fixation is commonly used although contemporary locking plate systems are now available. This study tested the hypothesis that a 10mm MDO would support a higher load to failure with a locked step plate than with a single cannulated screw. Materials and Methods. Eight pairs of embalmed cadaveric limbs harvested 10cm below the knee joint were axially loaded using a mechanical testing rig. Two pairs served as non-operated controls loaded to 4500N. The remaining limbs in pairs underwent a 10mm MDO of the os calcis and were stabilised with a locked step plate or a 7mm cannulated compression screw. One pair was loaded to 1600N (twice body weight) as a pilot study and the remaining 5 pairs were loaded to failure up to 4500N. The force-displacement curve and maximum force were correlated with observations of the mechanism of failure. Results. In one pair of control limbs, failure occurred with fractures through both os calcis bones, whilst the other pair did not undergo mechanical failure to 4500N. In the pilot osteotomy, the plate did not fail whilst loss of fixation with the screw was observed below 1600N. For the remaining five pairs, the median (with 95% Confidence Intervals) of the maximum force under load to failure were 1778.81N (1099.39 – 2311.66) and 826.13N (287.52 – 1606.67) for the plate and screw respectively (Wilcoxon Signed Rank test p=0.043). In those with screw fixation loaded to 4500N, the tuberosity fragment consistently failed by rotation and angulation into varus. Conclusion. In this model of load to failure with a medial displacement os calcis osteotomy, a locked step plate supported a significantly higher maximum force than a single large cannulated screw


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 262 - 262
1 Sep 2005
Lenehan B Murphy B McHugh P Curtin W
Full Access

Over the past four decades, internal fixation has continued to gain popularity as a method for treating fractures because of significant improvements in both implant design and materials. This biomechanical study compares the compressive forces generated by a conventional 4.5 AO/ASIF cortical screw lag screw with a differential pitch cortical compression screw in a simulated fracture model using whole bone composite femur. The differential pitch screw investigated in this study generates 82% of the compression generated by a conventional 4.5mm AO/ASIF cortical screw. Proving compression in diaphyseal fractures is achievable using a differential pitch screw. Sufficient compression is generated to allow osteosynthesis using a plate to be preformed independent of the lag screw positioning. It is thus advantageous over the traditional compromise that arises when exposure to the fracture site is limited, of either incorporating the lag screw into the plate of choosing a non-optimal plate or screw position. It is proposed as an adjunct to the internal fixation of long bone fractures and not a single fixation device


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 4 | Pages 535 - 538
1 Nov 1981
Shmueli G Herold H


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 390 - 390
1 Sep 2005
Peleg E Mattan Y Liebergall M Mosheiff R
Full Access

Introduction: Decreasing the length of the side plate of the dynamic hip screw (DHS) would theoretically allow a smaller surgical incision, a shorter surgical time, decreased operative blood loss and minimal periosteal stripping. A new design of a very short plate (VSP) dynamic hip screw based on two diagonal screws has been developed. The new design was compared with the four hole side plate regarding its mechanical properties and bio-mechanical outcomes.

Methods: Four pairs of fresh frozen cadaveric femora were extracted from male corpses aged 25–43 (mean 34.8), mechanical loading was applied to four pairs of cadaveric femora which were fixated using the new system on one side and the conventional design on the other. The decline during the periodical loading and the breakage load of the fixated bones were measured. In addition, mechanical performance and probability for failure was assessed by conducting a mathematical analysis using the finite element method.

Results: The average deflection under excessive cyclic loading was 33% higher in bones with the VSP-DHS device than those with regular DHS. The average load failure during the collapse loading test was 312 kg for the VSP-DHS compared to 416 kg for the regular device. The mathematical analysis performed indicated that the maximal stress in the VSP-DHS reached values 3–4 fold higher than in the regular DHS.

Conclusions: Bio-mechanical evaluation was performed both by mechanical testing and theoretically. Although the new design offers a minimally invasive approach to subtrochanteric femur fracture fixation, it was found to have insufficient biomechanical performance resulting in high probability for mechanical failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 78 - 82
1 Jan 1986
Skinner P Powles D

We report a prospective study of 198 cases of subcapital fracture of the femur treated by closed reduction and fixation with a sliding compression screw-plate. This was done without regard to the patient's age or the Garden stage of the fracture. Early weight-bearing was encouraged. Of the displaced fractures 23% failed in the first year because of non-union or infection. Of the fractures which united 27% had developed avascular necrosis after three years. Despite this we believe that the sliding compression screw-plate, of proven value in the treatment of intertrochanteric fractures, is also useful for the fixation of subcapital fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 199 - 201
1 Mar 1988
Christie J Howie C Armour P

One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 117 - 117
1 Sep 2012
Gupta A Cooke C Wilkinson M Grazette A
Full Access

Prospective Randomised Control trial of 300 patients over a period of 3 years, 1 year post op follow up. Local ethic approval was attained for the study. Inclusion criteria: Age > 60, Consented to Participate in the study, Unstable Inter trochanteric fracture a) Sub trochanteric b) Medial Comminution c) Reverse Obliquity D)Severe Osteoporosis. Patients selected were randomized to Intra medullary Nail vs Hips screw. Variety of markers have been assessed: Pre OP: - Mechanism of injury, Mobility status, Pre OP ASA, Pre Op haemoglobin, living Conditions. Intra OP:- I.I Time, Time taken, Surgeon experience, Intra OP complications. Post OP:- Haemoglobin, mobility, radiographic analysis-Fracture stability and Tip Apex Distance, Thrombo embolic Complications. Follow up: - 6 weeks, 3,6,12 month follow up. There is considerable debate in literature regarding superiority of Compression Hip screw over Intra medullary nail for fixation of stable per trochanteric fractures of the femur. Biomechanical studies have shown superiority of Intra medullary device over a Compression Hip screw. Tenser et all showed an advantage over combined bending and compression failure. Mohammad et al found unstable subtrochanteric fractures with a gamma nail were stiffer. Kerush-Brinker showed that gamma nail had significantly greater fatigue strength and fatigue life. In unstable fractures Baumgartner et al found less intra op complications and less fluoroscopic time for a compression hip screw compared to a short intra medullary nail. There have been significant reports of fracture at the Tip of a short intra medullary nail. We think this complication can be avoided by using a long intra medullary device. Both in Australia and abroad the choice of which device to use depends largely on the preference of the surgeon


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1210 - 1217
1 Sep 2007
Peyser A Weil YA Brocke L Sela Y Mosheiff R Mattan Y Manor O Liebergall M

Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices. We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively. The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s t-test, p < 0.0001). The pain score and ability to bear weight were significantly better in the PCCP group at six weeks post-operatively. Analysis of the radiographs in a proportion of the patients revealed a reduced amount of medial displacement in the PCCP group (two patients, 4%) compared with the CHS group (10 patients, 18.9%); Fisher’s exact test, p < 0.02. The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 313 - 314
1 Jul 2011
Ahmad M Bajwa A Patil S Bhattacharya R Nanda R Danjoux G Hui A
Full Access

Introduction: To quantify the magnitude and incidence of haemodynamic changes that occurs during the fixation of extracapsular proximal femoral fractures when using either intra-medullary or extra-medullary fixation device. Methods: A prospective group of 31 patients with extra-capsular proximal femoral fractures were randomised to either fixation using an extra-medullary compression hip screw or an intra-medullary hip screw. All patients received a general anaesthetic adhering to a standardised anaesthetic protocol including invasive blood pressure monitoring and arterial blood gas sampling. Trans-oesophageal Doppler probe and monitor was used to record pre-operative hypovolaemia and peri-operative changes in cardiac output, stroke volume and corrected flow time (FTc – a reflection of left ventricular end diastolic pressure) during placement of implants. Results: 77% of patients were hypovolaemic preoperatively, which was corrected with an average of 439 mls of colloid replacement fluid. Application of the extra-medullary CHS produced no change in haemodynamic function. However on insertion of the IMHS we found a statistically significant reduction in stroke volume, cardiac output and FTc without changes in pulse rate or mean arterial pressure. The changes were transient with normal cardiac function returning by 5 mins post operatively. Conclusion: The transient fall in cardiac function during insertion of the intramedullary hip screw may be caused by fat embolism entering the venous circulation. As these changes are not detected with standard non-invasive monitoring we would recommend that intramedullary devices be used with caution in elderly patients who tend to have poor physiological reserve


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 85 - 85
1 Jan 2016
Suh Y Nho J Park J Lee Y Ha Y Koo K
Full Access

Introduction

In comminuted intertrochanteric fractures, various operative options have been introduced. The purpose of this study was to determine whether there were differences in clinical and radiologic outcomes among bipolar hemiarthroplasty(BH), compression hip screw(CHS) and proximal femur nail antirotatory(PFNA) in treating comminuted intertrochanteric fractures(AO type, A2(21, 22, 23))

Materials and Methods

We retrospectively evaluated total 150 patients(BH:50, CHS:50, PFNA: 50) who were operated due to intertrochanteric fractures from March 2010 to Dec 2012 and were older than 65 years at the time of surgery. We compared these three groups for radiologic and clinical outcomes at 12 months postoperatively, including Harris hip score, ability of ambulation(Koval stage), visual analogue scale and radiologic limb length discrepancy(shortening). Landmark and radiologic length was checked.

–A: postoperative length

–A’: POD 1year

–B: immediate posteopative contralateral length(from hip center to distal tip of lesser trochanter)

–B’: POD 1year contralateral length(from hip center to distal tip of lesser trochanter)

Limb length(shortening) was adjusted considering difference of magnification

= {A × (B’/B)}− A’


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 551 - 552
1 Oct 2010
Khunda A Hui A Rookmoneea M
Full Access

Aim: To compare the acute haemoglobin level drop following hip fracture fixation with IMHS and CHS at James Cook University Hospital and assess whether the surgeon’s seniority has any effect on the amount of blood loss in these two procedures.

Methods: Trauma data base was searched for all IMHS procedures performed from January 2002 till March 2007 both included and CHS procedures performed from January 2007 till March 2008 both included.

There were 159 CHS procedures and 146 IMHS procedures. 137 CHS and 123 IMHS procedures fulfilled the blood testing and transfusion criteria.

Haemoglobin levels were used as an indication for blood loss attributable to surgery. The difference between the last level of haemoglobin checked preoperatively and the first post operative level performed between 12–48 hours postoperatively is calculated. Cases where blood transfusion was carried out preoperatively without further preoperative haemoglobin check were excluded, so were cases receiving intra or post operative blood transfusion prior to the defined postoperative haemoglobin check was carried out.

Results: SPSS 13.0 statistical package was used to analyse the results. Levene’s test proved equality of variances of blood loss within the two groups of patients undergoing one of the two procedures, P=0.5. Hence, Independent Samples T test was applicable and showed that patients undergoing an IMHS procedure dropped their haemoglobin levels by 2.96 g/dl. While, those undergoing a CHS procedure dropped their haemoglobin levels by 2.32 g/dl. The 0.64 g/dl difference in haemoglobin drop was statistically significant at 5% significance level with 95% CI (0.27 to 1.01), P=0.001.

The surgeons’ grades were classified into three groups as: Consultants, Registrars and Senior House Officers. Levene’s test again proved the variances of haemoglobin drop within each group to be homogeneous. Hence a One-Way ANOVA test was carried out showing that the differences in haemoglobin drop were not statistically significant when comparing the three groups of surgeons to each other. This was true for both IMHS and CHS procedures.

Conclusion: Patients undergoing a CHS procedure drop their haemoglobin levels by 0.64 g/dl less than those undergoing an IMHS procedure. The surgeon’s seniority does not make difference to the amount of haemoglobin level drop following either of the two procedures.

We recommend the use of CHS for stable fractures and reserve the IMHS for the unstable ones due to the increased blood loss with IMHS procedures.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 41 - 41
1 Feb 2020
Studders C Saliken D Shirzadi H Athwal G Giles J
Full Access

INTRODUCTION. Reverse shoulder arthroplasty (RSA) provides an effective alternative to anatomic shoulder replacements for individuals with cuff tear arthropathy, but certain osteoarthritic glenoid deformities make it challenging to achieve sufficient long term fixation. To compensate for bone loss, increase available bone stock, and lateralize the glenohumeral joint center of rotation, bony increased offset RSA (BIO-RSA) uses a cancellous autograft for baseplate augmentation that is harvested prior to humeral head resection. The motivations for this computational study are twofold: finite element (FE) studies of BIO-RSA are absent from the literature, and guidance in the literature on screw orientations that achieve optimal fixation varies. This study computationally evaluates how screw configuration affects BIO-RSA graft micromotion relative to the implant baseplate and glenoid. METHODS. A senior shoulder specialist (GSA) selected a scapula with a Walch Type B2 deformity from patient CT scans. DICOM images were converted to a 3D model, which underwent simulated BIO-RSA with three screw configurations: 2 divergent superior & inferior locking screws with 2 convergent anterior & posterior compression screws (SILS); 2 convergent anterior & posterior locking screws and 2 superior & inferior compression screws parallel to the baseplate central peg (APLS); and 2 divergent superior & inferior locking screws and 2 divergent anterior & posterior compression screws (AD). The scapula was assigned heterogeneous bone material properties based on the DICOM images’ Hounsfield unit (HU) values, and other components were assigned homogenous properties. Models were then imported into an FE program for analysis. Anterior-posterior and superior-inferior point loads and a lateral-medial distributed load simulated physiologic loading. Micromotion data between the RSA baseplate and bone graft as well as between the bone graft and glenoid were sub-divided into four quadrants. RESULTS. In all but 1 quadrant, APLS performed the worst with the graft having an average micromotion of 347.1µm & 355.9 µm relative to the glenoid and baseplate, respectively. The SILS configuration ranked second, having 211.2 µm & 274.4 µm relative to the glenoid and baseplate. AD performed best, allowing 247.4 µm & 225.4 µm of graft micromotion relative to the glenoid and baseplate. DISCUSSION. Both APLS and SILS techniques are described in the literature for BIO-RSA fixation; however, the data indicate that AD is superior in its ability to reduce graft micromotion, and thus some revision to common practices may be necessary. While these micromotion data are larger than data in the extant RSA literature, there are several factors that account for this. First, to properly model the difference between locking and compression screws, we simulated friction between the compression screw heads and baseplate rather than a tied constraint as done in other studies, resulting in larger micromotion. Second, the trabecular bone graft is at greater risk of deforming than metallic spacers used when studying micromotion with glenosphere lateralization, increasing graft deflection magnitude. Future work will investigate the effects of various BIO-RSA variables. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 11 - 11
23 Jul 2024
Sarhan M Moreau J Francis S Page P
Full Access

Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population. The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with Cephalomedullary nails to review and compare Gamma (2013–2017) and TFNA (2017–2023) failure rates and the timing of the failures. Infected and Elective revision to Arthroplasty cases were excluded. The results are 1034 cases had been included, 784 fixed with TFNA and 250 cases fixed Gamma nails. Out of the 784 patients fixed with TFNA, 19 fixation failed (2.45%). Out of the 250 cases fixed with Gamma nails, 15 fixation failed (6%). Mean days for fixation failure were 323 and 244 days in TFNA and Gamma nails respectively. We conclude that TFNA showed remarkable less failure rates if compared to Gamma nails. At point of launch, testing was limited and no proof of superiority of TFNA over Gamma nail. Several failures identified with proximal locking aperture in TFNA which can be related to the new design which had Substantial reduction in lateral thickness at compression screw aperture