Advertisement for orthosearch.org.uk
Results 1 - 14 of 14
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 65 - 65
17 Apr 2023
Tacchella C Lombardero SM Clutton E Chen Y Crichton M
Full Access

In this work, we propose a new quantitative way of evaluating acute compartment syndrome (ACS) by dynamic mechanical assessment of soft tissue changes. First, we have developed an animal model of ACS to replicate the physiological changes during the condition. Secondly, we have developed a mechanical assessment tool for quantitative pre-clinical assessment of ACS. Our hand-held indentation device provides an accurate method for investigations into the local dynamic mechanical properties of soft tissue and for in-situ non-invasive assessment and monitoring of ACS. Our compartment syndrome model was developed on the cranial tibial and the peroneus tertius muscles of a pig's leg (postmortem). The compartment syndrome pressure values were obtained by injecting blood from the bone through the muscle. To enable ACS assessment by a hand-held indentation device we combined three main components: a load cell, a linear actuator and a 3-axis accelerometer. Dynamic tests were performed at a frequency of 0.5 Hz and by applying an amplitude of 0.5 mm. Another method used to observe the differences in the mechanical properties inside the leg was a 3D Digital Image Correlation (3D-DIC). Videos were taken from two different positions of the pig's leg at different pressure values: 0 mmHg, 15 mmHg and 40 mmHg. Two strains along the x axis (Exx) and y axis (Eyy) were measured. Between the two pressure cases (15 mmHg and 40 mmHg) a clear deformation of the model is visible. In fact, the bigger the pressure, the more visible the increase in strain is. In our animal model, local muscle pressures reached values higher than 40 mmHg, which correlate with observed human physiology in ACS. In our presentation we will share our dynamic indentation results on this model to demonstrate the sensitivity of our measurement techniques. Compartment syndrome is recognised as needing improved clinical management tools. Our approach provides both a model that reflects physiological behaviour of ACS, and a method for in-situ non-invasive assessment and monitoring


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 906 - 911
1 Aug 2004
Kearns SR Daly AF Sheehan K Murray P Kelly C Bouchier-Hayes D

Compartment syndrome is a unique form of ischaemia of skeletal muscle which occurs despite patency of the large vessels. Decompression allows the influx of activated leucocytes which cause further injury. Vitamin C is a powerful antioxidant which concentrates preferentially in leucocytes and attenuates reperfusion-induced muscle injury. We have evaluated the use of pretreatment with oral vitamin C in the prevention of injury caused by compartment syndrome in a rat cremasteric muscle model. Acute and delayed effects of pretreatment with vitamin C were assessed at one and 24 hours after decompression of compartment syndrome. Muscle function was assessed electrophysiologically. Vascular, cellular and tissue inflammation was assessed by staining of intercellular adhesion molecule-1 (ICAM-1) and by determination of the activity of myeloperoxidase (MPO) in neutrophils and tissue oedema. Compartment syndrome impaired skeletal muscle function and increased the expression of ICAM-1, activity of MPO and muscle weight increased significantly. Pretreatment with vitamin C preserved muscle function and reduced the expression of ICAM-1, infiltration of the neutrophils and oedema


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 10 - 10
17 Nov 2023
Lim JW Ball D Johnstone A
Full Access

Abstract. Background. Progressive muscle ischaemia results in reduced aerobic respiration and increased anaerobic respiration, as cells attempt to survive in a hypoxic environment. Acute compartment syndrome (ACS) is a progressive form of muscle ischaemia that is a surgical emergency resulting in the production of Lactic acid by cells through anaerobic respiration. Our previous research has shown that it is possible to measure H+ ions concentration (pH) as a measure of progressive muscle ischaemia (in vivo) and hypoxia (in vitro). Our aim was to correlate intramuscular pH readings and cell viability techniques with the intramuscular concentration of key metabolic biomarkers [adenosine triphosphate (ATP), Phosphocreatine (PCr), lactate and pyruvate], to assess overall cell health in a hypoxic tissue model. Methods. Nine euthanised Wistar rats were used in a non-circulatory model. A pH catheter was used to measure real-time pH levels from one of the exposed gluteus medius muscles, while muscle biopsies were taken from the contralateral gluteus medius at the start of the experiment and subsequently at every 0.1 of a pH unit decline. The metabolic biomarkers were extracted from the snap frozen muscle biopsies and analyzed with standard fluorimetric method. Another set of biopsies were stained with Hoechst 33342, Ethidium homodimer-1 and Calcein am and imaged with a Zeiss LSM880 confocal microscope. Results. Our study shows that the direct pH electrode readings decrease with time and took an average of 69 minutes to drop to a pH of 6.0. The concentrations of ATP, pyruvate and PCr declined over time, and the concentration of lactate increased over time. At pH 6.0, both ATP and PCr concentrations had decreased by 20% and pyruvate has decreased by 50%, whereas lactate had increased 6-fold. The majority of cells were still viable at a pH of 6.0, suggesting that skeletal muscle cells are remarkably robust to hypoxic insult, although this was a hypoxic model where reperfusion was not possible. Conclusions. Our research suggests that histologically, skeletal muscle cells are remarkably robust to hypoxic insult despite the reduction in the total adenine nucleotide pool, but this may not reflect the full extent of cell injury and quite possibly irreversible injury. The timely restoration of blood flow in theory should halt the hypoxic insult, but late reperfusion results in cellular dysfunction and cell death due to localised free radical formation. Further research investigating the effects of reperfusion in vivo are warranted, as this may identify an optimal time for using pharmacological agents to limit reperfusion injury, around the time of fasciotomy to treat acute compartment syndrome. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 365 - 369
1 Mar 1998
Abraham P Leftheriotis G Saumet JL

Chronic compartment syndrome (CCS) is usually considered to be due to ischaemia of muscle. We have attempted to use the direct measurement of muscle blood flow for diagnosis since the assessment of intracompartmental pressure does not provide accurate knowledge of the vascular state. We recorded simultaneously continuous measurements of the laser Doppler flow (LDF) in muscle and the intracompartment pressure (ICP) after exercise in seven patients with CCS, and in seven control subjects. The mean ICP was 74.1 ± 4.4 mmHg in CCS patients and 24.2 ± 3.4 mmHg in control subjects one minute after exercise, decreasing to 34.6 ± 2.3 mmHg and 15.0 ± 1.6 mmHg at 20 min, respectively. The LDF was 0.80 ± 0.11 arbitrary units (AU) in control subjects and 1.09 ± 0.14 AU in CCS patients one minute after exercise, and 0.41 ± 0.11 AU and 0.27 ± 0.04 AU, respectively, at the end of the recovery period. The ICP showed a progressive decrease over time in both groups. The LDF decreased sharply during the first minutes of recovery in control subjects, but in patients with CCS there was a delayed hyperaemic peak with blood flow reaching 0.84 ± 0.10 AU at nine minutes as against 0.33 ± 0 .06 AU for control subjects (p < 0.01). The ICP increased in both control subjects and CCS patients after exercise with no clear cut-off point between the groups. By contrast, changes in muscle blood flow over time were clearly different between control subjects and patients with CCS. For this reason, LDF should be investigated further as a technique for the diagnosis of CCS


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 38 - 38
17 Apr 2023
Saiz A Hideshima K Haffner M Rice M Goupil J VanderVoort W Delman C Hallare J Choi J Shieh A Eastman J Wise B Lee M
Full Access

Determine the prevalence, etiologies, and risk factors of unplanned return to the OR (UROR) in adult orthopaedic trauma patients. Retrospective review of a trauma prospective registry from 2014 – 2019 at a Level 1 academic hospital. An UROR was defined as a patient returning to OR unexpectedly following a planned definitive surgery to either readdress the presenting diagnosis or address a complication arising from the index procedure. Univariate and multivariate logistic regression was performed comparing those patients with an UROR versus those without. A total of 1568 patients were reviewed. The rate of UROR was 9.8% (153 patients). Symptomatic implant was the leading cause of UROR (60%). Other significant UROR causes were infection (15%) and implant failure (9%). The median time between index procedure and UROR was 301 days. For the univariate and multivariate analysis, open fracture (p< 0.05), fracture complexity (p<0.01), and weekend procedure (p< 0.01) were all associated with increased risk of UROR. All other variables were not statistically significant for any associations. Those patients with an UROR for reasons other than symptomatic implants were more likely to have polyorthopaedic injuries (p < 0.05), ISS > 15 (p < 0.05), osteoporosis (p < 0.01), ICU status (p < 0.05), psychiatric history (p < 0.05), compartment syndrome (p < 0.05), neurovascular injury (p < 0.01), open fracture (p < 0.05), and fracture complexity (p < 0.05). The rate of UROR in the orthopaedic trauma patient population is 10%. Most of these cases are due to implant-related issues. UROR for reasons other than symptomatic implants tend to be polytraumatized patients with higher-energy injuries, multiple complex fractures, and associated soft tissue injuries. Future focus on improved implant development and treatments for polytraumatized patients with complex fractures is warranted to decrease a relatively high UROR rate in orthopaedic trauma


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1114 - 1118
1 Aug 2008
Ling ZX Kumar VP

Compartment syndrome of the foot requires urgent surgical treatment. Currently, there is still no agreement on the number and location of the myofascial compartments of the foot. The aim of this cadaver study was to provide an anatomical basis for surgical decompression in the event of compartment syndrome. We found that there were three tough vertical fascial septae that extended from the hindfoot to the midfoot on the plantar aspect of the foot. These septae separated the posterior half of the foot into three compartments. The medial compartment containing the abductor hallucis was surrounded medially by skin and subcutaneous fat and laterally by the medial septum. The intermediate compartment, containing the flexor digitorum brevis and the quadratus plantae more deeply, was surrounded by the medial septum medially, the intermediate septum laterally and the main plantar aponeurosis on its plantar aspect. The lateral compartment containing the abductor digiti minimi was surrounded medially by the intermediate septum, laterally by the lateral septum and on its plantar aspect by the lateral band of the main plantar aponeurosis. No distinct myofascial compartments exist in the forefoot. Based on our findings, in theory, fasciotomy of the hindfoot compartments through a modified medial incision would be sufficient to decompress the foot


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 9 - 9
17 Nov 2023
Lim JW Ball D Johnstone A
Full Access

Abstract. Objectives. Acute compartment syndrome (ACS) is a progressive form of muscle ischaemia that is a surgical emergency and can have detrimental outcomes for patients if not treated optimally. The current problem is that there is no clear diagnostic threshold for ACS or guidance as to when fasciotomies should be performed. A new diagnostic method(s) is necessary to provide real-time information about the extent of muscle ischaemia in ACS. Given that lactic acid is produced by cells through anaerobic respiration, it may be possible to measure H+ ion concentration and to use this as a measure of ischaemia within muscle. Although we are familiar with the key biochemical metabolites involved in ischaemia; and the use of viability dyes in cell culture to distinguish between living or dead cells is well recognised; research has not been undertaken to correlate the biochemical and histological findings of ischaemia in skeletal muscle biopsies. Our primary aim was to investigate the potential for viability dyes to be used on live skeletal muscle biopsies (explants). Our secondary aim was to correlate the intramuscular pH readings with muscle biopsy viability. Methods. Nine euthanised Wistar rats were used. A pH catheter was inserted into one exposed gluteus medius muscles to record real-time pH levels and muscle biopsies were taken from the contralateral gluteus medius at the start of experiment and subsequently at every 0.1 of pH unit drop. Prior to muscle biopsy, the surface of the gluteus medius was painted with a layer of 50µmol/l Brilliant blue FCF solution to facilitate biopsy orientation. A 4mm punch biopsy tool was used to take biopsies. Each muscle biopsy was placed in a base mould filled with 4% ultra-low melting point agarose. The agarose embedded tissue block was sectioned to generate 400 micron thick tissue slices with a vibratome. The tissue slices were then placed in the staining solution with Hoechst 33342, Ethidium homodimer-1 and Calcein am. The tissue slices were imaged with Zeiss LSM880 confocal microscope's Z stack function. A dead muscle control was created by adding TritonX-100 to other tissue slices. For quantitative analyses, the images were analysed in Image J using the selection tool. This permitted individual cells to be identified and the mean grey value of each channel to be defined. Using the dead control, we were able to identify the threshold value for living cells using the Calcein AM channel. Results. Viability dyes, used primarily for cell cultures, can be used with skeletal muscle explants. Our study also showed that despite a significant reduction in tissue pH concentration over time, that almost 100% of muscle cells were still viable at pH 6.0, suggesting that skeletal muscle cells are robust to hypoxic insult in the absence of reperfusion. Conclusions. Viability dyes can be used on skeletal muscle biopsies. Further research investigating the likely associations between direct measured pH using a pH catheter, the concentrations of key cellular metabolic markers, and muscle tissue histology using vitality dyes in response to ischaemia, rather than hypoxia, is warranted. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 111 - 111
1 Dec 2020
Lim JA Thahir A Krkovic M
Full Access

Introduction. The BOAST (British Orthopaedic Association Standards for Trauma) guidelines do advise that open pilon fractures amongst other open lower limb fractures need to be treated at a specialist centre with Orthoplastic care. The purpose of this study was to determine clinical outcomes in patients with open pilon fractures treated as per BOAST guidelines including relatively aggressive bone debridement. Methods. A retrospective analysis of a single surgeon series of open pilon fractures treated between 2014 and 2019 was conducted. Injuries were graded according to the Gustillo-Anderson classification and all patients were included for the assessment of the rate of infection and fracture healing. Functional outcome assessment was performed in all patients according to the American Orthopedic Foot and Ankle Score (AOFAS) at 6 months after definitive surgery. Initial wound with bone debridement and application of a spanning external fixator was performed within an average of 13.5 (Range: 3–24) hours. Fixation with FWF (Fine Wire Frame) was performed when the wound was healed, with the mean time from primary surgery to application of FWF being 24.5 (Range: 7–60) days. Results. There was a total of 20 patients including 16 males and 4 females. The mean age was 50.45 (Range: 16–88) years. Follow-up was for an average of 23.2 (Range: 5–51) months. There were 3 patients with Gustilo Type I injuries, 6 with Type II, 4 Type with type IIIa and 7 with Type IIIb injuries. Average time to bone union was 9.3 (Range: 2–18) months. The mean AOFAS score was 66 (Range: 15–97) points. TSF was used on 18 patients, while 2 patients had an Ilizarov frame. A corticotomy was performed on 4 patients with critical bone defect post debridement, while 2 patients had Stimulan beads with antibiotics. There was 1 case (5%) of deep infection and 9 cases (45%) of superficial infection. There were also 2 cases (10%) of non-union which required bone grafting from their femur using a RIA (Reamer Irrigation Aspirator). Other complications included 1 case of acute compartment syndrome, 1 case of pulmonary embolism, 1 case of necrotic skin and 1 case of amputation. Conclusion. Results of our study suggests that the use of staged wound debridement including relatively aggressive bone debridement in conjunction with antibiotics, external fixators and patient tailored conversion from spanning external fixator to fine wire frame achieves low rates of wound infection and complications for patients with open pilon fractures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 9 - 9
1 Nov 2018
Houlden R Peat F Barrett M Melton J
Full Access

Acute multiligament knee injuries (MLKI) are rare, high energy traumatic injuries associated with an increased risk of lower limb complications. The objectives of this study were to investigate the adequacy of clinical assessment for neurovascular status, compartment syndrome, and deep vein thrombosis in the emergency department (ED) following acute MLKI. The authors conducted a retrospective case note review of 19 patients with MLKI presenting at the ED of a Major Trauma Centre during a 7.5-year period between June 2009 and December 2016. MLKIs were diagnosed by MRI or examination under anaesthesia and confirmed intraoperatively. Arterial assessment consisted of documented capillary refill time, dorsalis pedis and posterior tibial pulse assessment (through palpation or Doppler ultrasound), and ankle-brachial pressure index (ABPI) calculation. Neural assessment was adequate if there was documented assessment of both sensory and motor function of the superficial peroneal, deep peroneal and tibial nerves individually. Data was collected for 19 patients (17 male, 2 female). The mean age was 34 (range: 14–61). The most common injury mechanism was road traffic accident. Neurovascular assessment was suboptimal in all categories: only one patient received a satisfactory lower limb neurological assessment and no patients received complete vascular assessments. Neurovascular assessment of multiligament knee injuries was suboptimal. Reasons for this included poor documentation and lack of certain specific clinical assessments, such as ABPI calculation. We propose the introduction of an acute knee injury pro forma highlighting the components of a full lower limb neurovascular examination to rectify this problem


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 61 - 61
1 Jul 2014
Alqahtani S Harvey E Henderson J Chodavarapu V Wang Y Allan C
Full Access

Significance. Acute compartment syndrome (ACS) occurs after muscle injury and is characterised by increased pressure in the muscle compartment that can result in devastating complications if not diagnosed and treated appropriately. ACS is currently confirmed by repeated needle sticks to measure the compartment pressure using a hand-held compartment pressure monitor. This approach is often not reproducible and is not appropriate for continuous monitoring. To address the shortcomings of currently available technology we are developing an implantable micro-device that will measure compartment pressure directly and continuously over the 24 hours critical period following injury using a radio frequency identification (RFID) platform integrated with a MEMS capacitive pressure sensor. Methods. The prototype implantable device measuring 3mmx3mm consists of a capacitive pressure sensor, a sensor readout circuitry, an antenna and a radio frequency reader. A prototype sensor was packaged in Silicone gel (MED-6640, Nusil Technology LLC) for ex vivo and in vivo testing in three compartment models. First, it was tested ex vivo in an airtight vessel using a blood pressure monitor to pump air and increase the pressure inside the vessel. Second, it was implanted in a muscle compartment of a fresh porcine hind limb and an infusion pump with normal saline was used to raise the tissue pressure. Third, it was implanted in the posterior thigh muscle of a rat where the pressure was increased by applying a tourniquet around the thigh. The readings were compared with those from a hand-held Stryker Intra-compartmental Pressure Monitor System used in the trauma room. Results. The sensor reading from the radio frequency reader software interface in all three models showed good linearity against the pressure applied to the compartment. Conclusion. The successful completion of this project will lead to the development of an implantable miniaturised wireless pressure sensor microsystem capable of measuring tissue compartment pressures in the critical period after traumatic injury and reduce the incidence of serious complications such as severe pain, paralysis, sensory deficits, muscle necrosis and permanent disability


Bone & Joint 360
Vol. 3, Issue 1 | Pages 37 - 38
1 Feb 2014
Hak DJ


Bone & Joint Research
Vol. 5, Issue 7 | Pages 287 - 293
1 Jul 2016
Ismail H Phedy P Kholinne E Djaja YP Kusnadi Y Merlina M Yulisa ND

Objectives

To explore the therapeutic potential of combining bone marrow-derived mesenchymal stem cells (BM-MSCs) and hydroxyapatite (HA) granules to treat nonunion of the long bone.

Methods

Ten patients with an atrophic nonunion of a long bone fracture were selectively divided into two groups. Five subjects in the treatment group were treated with the combination of 15 million autologous BM-MSCs, 5g/cm3 (HA) granules and internal fixation. Control subjects were treated with iliac crest autograft, 5g/cm3 HA granules and internal fixation. The outcomes measured were post-operative pain (visual analogue scale), level of functionality (LEFS and DASH), and radiograph assessment.


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 393 - 399
1 Mar 2008
Morley JR Smith RM Pape HC MacDonald DA Trejdosiewitz LK Giannoudis PV

We have undertaken a prospective study in patients with a fracture of the femoral shaft requiring intramedullary nailing to test the hypothesis that the femoral canal could be a potential source of the second hit phenomenon. We determined the local femoral intramedullary and peripheral release of interleukin-6 (IL-6) after fracture and subsequent intramedullary reaming.

In all patients, the fracture caused a significant increase in the local femoral concentrations of IL-6 compared to a femoral control group. The concentration of IL-6 in the local femoral environment was significantly higher than in the patients own matched blood samples from their peripheral circulation. The magnitude of the local femoral release of IL-6 after femoral fracture was independent of the injury severity score and whether the fracture was closed or open.

In patients who underwent intramedullary reaming of the femoral canal a further significant local release of IL-6 was demonstrated, providing evidence that intramedullary reaming can cause a significant local inflammatory reaction.