Aims. Patients receiving cemented hemiarthroplasties after hip fracture have a significant risk of deep surgical site infection (SSI). Standard UK practice to minimize the risk of SSI includes the use of antibiotic-loaded bone cement with no consensus regarding type, dose, or antibiotic content of the cement. This is the protocol for a randomized
To compare the functionality of adults with displaced mid-shaft clavicular fractures treated either operatively or nonoperatively and to compare the relative risk of nonunion and reoperation between the two groups. Based on specific eligibility criteria, 120 adults (median age 37.5 years (interquartile range (18 to 61)) and 84% males (n = 101)) diagnosed with an acute displaced mid-shaft fracture were recruited, and randomized to either the operative (n = 60) or nonoperative (n = 60) treatment group. This randomized controlled, partially blinded trial followed patients for 12 months following initial treatment. Functionality was assessed by the Constant score (CS) (assessor blinded to treatment) and Disability of the Arm, Shoulder and Hand (DASH) score. Clinical and radiological evaluation, and review of patient files for complications and reoperations, were added as secondary outcomes.Aims
Methods
The aim of this study was to explore whether time to surgery affects functional outcome in displaced proximal humeral fractures A total of 250 patients presenting within three weeks of sustaining a displaced proximal humeral fracture involving the surgical neck were recruited at 32 acute NHS hospitals in the United Kingdom between September 2008 and April 2011. Of the 125 participants, 109 received surgery (fracture fixation or humeral head replacement) as per randomization. Data were included for 101 and 67 participants at six-month and five-year follow-up, respectively. Oxford Shoulder Scores (OSS) collected at six, 12, and 24 months and at three, four, and five years following randomization was plotted against time to surgery. Long-term recovery was explored by plotting six-month scores against five-year scores and agreement was illustrated with a Bland-Altman plot.Aims
Methods
Recent studies of nonoperatively treated displaced midshaft clavicular fractures have shown a high incidence of nonunion and unsatisfactory functional outcome. Some studies have shown superior functional results and higher rates of healing following operative treatment. The aim of this study was to compare the outcome in these patients after nonoperative management with those treated with fixation. In a multicentre, parallel randomized controlled trial, 146 adult patients with an acute displaced fracture of the midthird of the clavicle were randomized to either nonoperative treatment with a sling (71, 55 men and 16 women with a mean age of 39 years, 18 to 60) or fixation with a pre-contoured plate and locking screws (75, 64 men and 11 women with a mean age of 40 years, 18 to 60). Outcome was assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) Score, the Constant Score, and radiographical evidence of union. Patients were followed for one year.Aims
Patients and Methods
Pin-site infection remains a significant problem for patients treated by external fixation. A randomized trial was undertaken to compare the weekly use of alcoholic chlorhexidine (CHX) for pin-site care with an emollient skin preparation in patients with a tibial fracture treated with a circular frame. Patients were randomized to use either 0.5% CHX or Dermol (DML) 500 emollient pin-site care. A skin biopsy was taken from the tibia during surgery to measure the dermal and epidermal thickness and capillary, macrophage, and T-cell counts per high-powered field. The pH and hydration of the skin were measured preoperatively, at follow-up, and if pin-site infection occurred. Pin-site infection was defined using a validated clinical system.Aims
Methods
The aim of this study was to compare the incidence of anterior knee pain after antegrade tibial nailing using suprapatellar and infrapatellar surgical approaches A total of 95 patients with a tibial fracture requiring an intramedullary nail were randomized to treatment using a supra- or infrapatellar approach. Anterior knee pain was assessed at four and six months, and one year postoperatively, using the Aberdeen Weightbearing Test – Knee (AWT-K) score and a visual analogue scale (VAS) score for pain. The AWT-K is an objective patient-reported outcome measure that uses weight transmitted through the knee when kneeling as a surrogate for anterior knee pain.Aims
Patients and Methods
The aim of our study was to compare the incidence of post-operative anterior knee discomfort after anterograde tibial nailing by suprapatellar and infrapatellar approaches. 95 subjects presenting with a tibial fracture requiring an intramedullary nail were randomised to treatment using a suprapatellar (SP) or infrapatellar (IP) approach. Anterior knee discomfort was assessed at 4 months, 6 months and 1 year post operatively using the Aberdeen Weightbearing Test-Knee (AWT-K), knee specific patient reported outcome measures and the VAS pain score. The AWT-K is an objective measure which uses weight transmitted through the knee when kneeling as a surrogate for anterior knee discomfort. 53 patients were randomised to an SP approach and 42 to an IP approach. AWT-K results showed a greater mean proportion of weight transmitted through the injured leg compared to the uninjured leg when kneeling in the SP group compared to the IP group at all time points at all follow-up visits. This reached significance at 4 months for all time points except 30 seconds. It also reached significance at 6 months at 0 seconds and 1 year at 60 seconds. We conclude that the SP approach for anterograde tibial nailing reduces anterior knee discomfort post operatively compared to the IP approach.
Introduction. Reverse shoulder replacement is a surgical option for cuff tear arthropathy. However scapular notching is a concern. Newer designs of glenospheres are available to reduce scapular notching. Eccentric glenosphere with a lowered centre of rotation have been shown to improve range of adduction in vitro. We hypothesize that the eccentric glenosphere improve clinical outcomes and reduce scapular notching. Method. This is an ongoing randomized controlled double blind prospective
Proper cup positioning is a critical component in the success of total hip arthroplasty surgery. A multicenter study has been initiated to study a new type of highly cross-linked polyethylene. This study provides a unique opportunity to a review the acetabular cup placement of over 500 patients implanted in the past 2 years from 13 medical centers from the U.S., Mexico, and Europe. 482 patients have received primary total hip arthroplasty using components from a single manufacturer in 5 centers in the US and Mexico and 7 centers in Europe. The acetabular anteversion and inclination were measured in post-operative radiographs. An acceptable window of cup position is defined at 5–25° of anteversion and 30–45° of inclination.Introduction
Methods
Osteochondral ankle defects (OCDs) mainly occur in a young, active population. In 63% of cases the defect is located on the medial talar dome. Arthroscopic debridement and microfracture is considered the primary treatment for defects up to 15 mm. To treat patients with a secondary OCD of the medial talar dome, a 15-mm diameter metal implant (HemiCAP ®) was developed. The set of 15 offset sizes was designed to correspond with the anatomy of various talar dome curvatures. Recently, two independent biomechanical cadaver studies were published, providing rationale for clinical use. The present study was undertaken to evaluate the clinical effectiveness and safety of the metal implantation technique for osteochondral lesions of the medial talar dome in a prospective study. Since October 2007, twenty patients have been treated with the implant. Four patients who did not meet the inclusion criteria and four patients who had less than one-year follow-up at the time of writing were left out of this analysis. Twelve patients are reported with one year (n=8) or two years (n=4) follow-up. All patients had had one or two earlier operations without success. On preoperative CT-scanning, the mean lesion size was 16 × 11 (range, 9–26 × 8–14) mm. Outcome measures were: Numeric Rating Scale pain (NRS) at rest and when walking, Foot Ankle Outcome Score (FAOS), American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score, and clinical and radiographic complications. Data are presented as median and range. The Wilcoxon signed ranks test was used to calculate p-values.Objectives
Material and methods
Distal radius fractures are typical and frequent fracture of elderly woman with reduced bone density. Thus implant fixation is more difficult. Dorsal and radial comminution are frequent in these patients and so reduction and angle stable osteosynthesis needed. The angle stable plate, often also multidirectional is today the most common stabilisation device. Because of the introduction of bulky and bended implants as the Micronail or Targon DR wich require difficult opening of the bone with awles we decided to test the XS radius nail witch is a 4,5mm or 3,5mm straight nail and witch is introduced after guide wire placement and over drilling with a canulated drill of the same diameter. It is locked parallel to the joint in 3 different directions with angular stability with threaded wires. Methods 16 radius sawbones were osteotomised corresponding to a A3 Fracture and stabilised with a angle stable plate (8) and XS nail (8). 1000 alternating load cycles from 20–200N were performed and the deformation was registered. Also a FE analysis with the MSC Patran/Marc softwere were performed. Also the calculated deformation in the FE study was 20% lower. Also deformation amplitude was lower with 0.31mm compared to 0.42mm in the plate group. The differences however were not significant. Both devices show good biomechanical results. The XS nail has the advantage of mainly intraosseus position, simple operation technique with introduction over a guide wire from the proc. Styloideus radii and over drilling with a canulated drill of the same size. The exposure of the N rad. superf. must be performed. First clinical evaluation is presented. Due to the results we developed a anatomically adapted XS radius nail. The results of the first 100 patients are presented. Both angular stable plate and XSR nail can be used in unstable distal radius fracture fixation. The mainly intraosseus position of the nail and saving of the pronator quadratus as well as lower deformation are in favour of the XSR nail. However frontal plane fractures and very comminuted fractures are better treated with a multidirectional locking plate due to technical reasones so that we use the XSR nail mainly in A3 and C1 fractures.Conclusions
Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures. Methods. A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled,
Aims. The aim of this study was to describe the demographic details of patients who sustain a femoral periprosthetic fracture (PPF), the epidemiology of PPFs, PPF characteristics, and the predictors of PPF types in the UK population. Methods. This is a multicentre retrospective cohort study including adult patients presenting to hospital with a new PPF between 1 January 2018 and 31 December 2018. Data collected included: patient characteristics, comorbidities, anticoagulant use, social circumstances, level of mobility, fracture characteristics, Unified Classification System (UCS) type, and details of the original implant. Descriptive analysis by fracture location was performed, and predictors of PPF type were assessed using mixed-effects logistic regression models. Results. In total, 720 femoral PPFs from 27 NHS sites were included. PPF patients were typically elderly (mean 79.9 years (SD 10.6)), female (n = 455; 63.2%), had at least one comorbidity (n = 670; 93.1%), and were reliant on walking aids or bed-/chair-bound prior to admission (n = 419; 61.7%). The study population included 539 (74.9%) hip PPFs, 151 (21.0%) knee PPFs, and 30 (4.2%) dividing type PPFs. For hip (n = 407; 75.5%) and knee (n = 88; 58.3%) arthroplasty UCS B type fractures were most common. Overall, 556 (86.2%) were treated in the presenting hospital and 89 (13.8%) required transfer for treatment. Female sex was the only significant predictor of fracture type (A/B1/C type versus B2/B3) for femoral hip PPFs (odds ratio 0.61 (95% confidence interval 0.41 to 0.91); p = 0.014). Sex, residence type, primary versus revision implant PPF, implant fixation, and time between arthroplasty and PPF were not found to predict fracture type for hip PPFs. Conclusion. This multicentre analysis describes patient and injury factors for patients presenting with femoral PPFs to centres across the UK. These patients are generally elderly and frail, comparable to those sustaining a hip fracture. These data can be useful in planning future services and
Sub-acromial decompression surgery (SAD) has been widely used to treat shoulder impingement. Its validity has been questioned in multi-centric
Aims. The aim of this study was to investigate the relationship between the Orthopaedic Trauma Society (OTS) classification of open fractures and economic costs. Methods. Resource use was measured during the six months that followed open fractures of the lower limb in 748 adults recruited as part of two large
Aims. The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking. Methods. Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing. Results. A total of 37 micromotion patients and 46 control patients were evaluated. There were no significant differences between groups in terms of age, sex, the proportion of open fractures, or NURD score. There were no nonunions (0%) in the micromotion group versus five (11%) in the control group. The proportion of fractures united was significantly higher in the micromotion group compared to control at 12 weeks (54% vs 30% united; p = 0.043), 18 weeks (81% vs 59%; p = 0.034), and 24 weeks (97% vs 74%; p = 0.005). Structural bone healing scores as assessed by CT scans tended to be higher with micromotion compared to control and this difference reached significance in patients who had biological comorbidities such as smoking. Conclusion. In this pilot study, micromotion fixation was associated with improved healing compared to standard tibial nailing. Further prospective
Aims. To compare the cost-utility of standard dressing with incisional negative-pressure wound therapy (iNPWT) in adults with closed surgical wounds associated with major trauma to the lower limbs. Methods. A within-trial economic evaluation was conducted from the UK NHS and personal social services (PSS) perspective based on data collected from the Wound Healing in Surgery for Trauma (WHiST) multicentre randomized
Aims. To describe a new objective classification for open fractures of the lower limb and to correlate the classification with patient-centred outcomes. Methods. The proposed classification was investigated within a cohort of adults with open fractures of the lower limb who were recruited as part of two large
Aims. A lack of supporting
Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.Aims
Methods