Introduction. THR is one of the most frequently performed operations nationally. A large number of prostheses are available, and the procedure is therefore associated with variation in practice and outcomes. NICE guidelines aim to standardise best practice, and are informed by separate, independent bodies, such as the NJR and ODEP, which monitor data about the implants used and their performance. This study aims to determine whether clinical practice and component use has changed since the publication of NJR data. Methods. NJR reports from 2006–2014 were analysed, with record made of the different prostheses used in THR, noting ODEP ratings of components used. Analysis was also performed by component type (i.e. cemented and cementless stems and cups), and combinations of components, according to their frequency of use in a given year. The Kruksal-Wallis test was used for statistical analysis. Results. Analysis revealed that the number of components used with an A ODEP rating has increased from 2006–2014. However, there was no significant change (p=0.37) in the use of these components when expressed as a percentage of total procedures performed. Use of ODEP B, C and unclassified prostheses does not appear to have declined. During the period of study there has been a 9% rise in the number of implant combinations used, and a 37.9% rise in the number of implant combinations used fewer than 10 times annually, though these procedures now account for a lower percentage of the total performed annually. Discussion. Our analysis demonstrates that there has been limited
Considerable debate exists regarding which agent(s) should be preferred for venous thromboembolism (VTE) chemical prophylaxis following joint replacement. We assessed the practice of surgeons regarding VTE chemical prophylaxis for primary THR and TKR, pre and post issuing of updated NICE guidance in 2018. A survey, circulated through the British Hip Society and regional trainee networks/collaboratives, was completed by 306 UK surgeons at 187 units. VTE chemical prophylaxis prescribing patterns for surgeons carrying out primary THR (n=258) and TKR (n=253) in low-risk patients were assessed post publication of 2018 NICE recommendations. Prescribing patterns before and after the NICE publication were subsequently explored. Questions were also asked about surgeon equipoise for participation in future RCTs. Following the new guidance, 34% (n=87) used low-molecular weight heparin (LMWH) alone, 33% (n=85) aspirin (commonly preceded by LMWH), and 31% (n=81) direct oral anticoagulants (DOACs: with/without preceding LMWH) for THR. For TKR, 42% (n=105) used aspirin (usually monotherapy), 31% (n=78) LMWH alone, and 27% (n=68) DOAC (with/without preceding LMWH). NICE guidance
Studies have shown that 10–30% patients do not achieve optimal function outcomes after total hip replacement (THR). High quality randomised controlled trials (RCTs) evaluating the clinical and cost-effectiveness of techniques to improve functional outcomes after THR are lacking. We performed this study to evaluate the feasibility of a RCT comparing patient-reported functional outcomes after hybrid or fully cemented THR (ISRCTN11097021). Patients were recruited from two centres and randomised to receive either a fully cemented or hybrid THR. Data collection included Patient Reported Outcome Measures (PROMs), non-serious adverse events of special interest (AESI), serious adverse device effects (SADE) and NHS resource use. Qualitative interviews were undertaken to understand a) patient experiences of study processes and their reasons for taking part or not, and b) to understand surgeons’ perceptions of the study, factors affecting willingness to participate, and barriers to implementation of the future RCT findings. The target of 40 patients were successfully recruited for the feasibility RCT; the ratio of successful recruitment to eligible patients was 0.61 across both sites. Treatment crossovers occurred in four patients, all related to bone quality. Four patients were withdrawn due to not undergoing surgery within the study window because of the pandemic. Follow-up was 100% and PROMs were completed by all patients at all time points. The feasibility of conducting a within-trial cost-utility analysis was demonstrated. Interviews were conducted with 27 patients and 16 surgeons. Patients and surgeons generally found the study procedures acceptable and workable. Some declined participation because they did not want treatment allocated at random, or because blinding was off-putting. Surgeons’ perceptions of equipoise varied, and implementation of findings from the future RCT would need to recognise the ‘craft’ nature of surgery and the issue of training. We conclude that a full RCT with economic analysis will be both feasible and practicable, although mechanisms to safely implement potential
Aims. Studying the indications for revision total hip arthroplasty (THA) may enable surgeons to
Aims. Despite few good-quality studies on the subject, total hip arthroplasty (THA) is increasingly being performed for displaced intracapsular fractures of the neck of femur. We compared outcomes of all patients with displacement of these fractures treated surgically over a ten-year period in one institution. Methods. A total of 2,721 patients with intracapsular fractures of the femoral neck treated with either a cemented hemiarthroplasty or a THA at a single centre were retrospectively reviewed. The primary outcomes analyzed were readmission for any reason and revision surgery. We secondarily looked at mortality rates. Results. We found no difference in the overall revision rate or rate of infection. However, the rates of readmission due to dislocation, pain, and trochanteric bursitis were significantly higher in the THA group (p = 0.001, p < 0.001, p < 0.001, and p = 0.001, respectively). Conclusion. Our study, comparing the outcomes of neck of femur fractures treated with a cemented hemiarthroplasty and THA, revealed the perceived superiority of THA was not borne out by our results. This should be carefully considered before any radical
We report the impact of implementing a new short-stay hip and knee arthroplasty pathway in a National Health Service (NHS) hospital. This was enacted due to existing concerns with a long length of stay (LOS) and reduced elective operating capacity each winter due to emergency bed pressures. The overnight introduction of this pathway was aimed to reduce LOS, alleviate bed pressures, minimise readmission rates and generate financial savings, all combining to facilitate full elective activity during the winter. We conducted a prospective study at a regional tertiary arthroplasty centre. The new pathway was introduced across the service overnight. It includes rigorous preoperative optimisation, specific anaesthetic protocols and uniform
Despite increasing scientific investigation, the best method for preventing post-operative deep-vein thrombosis remains unclear. In the wake of the publication of the Pulmonary Embolism Prevention trial and the Scottish Intercollegiate Guidelines Network (SIGN) on the prevention of thromboembolism, we felt that it was timely to survey current thromboprophylactic practices. Questionnaires were sent to all consultants on the register of the British Orthopaedic Association. The rate of response was 62%. The survey showed a dramatic
Background. Much effort has been aimed at strategies for patient optimization, perioperative standards of care, and postoperative risk stratification to reduce the incidence of SSI. Examples include, newer dressing modalities, antibiotic-impregnated bone cement, intra-wound powdered antibiotics, as well as novel suture types and techniques, all of which have shown great potential. However, the question remains as to whether these
This study aimed to examine the changing trends in the causes for early revision of total hip replacements (THR) in one country over fifteen years to assess whether
This study reports mid-term outcomes after periacetabular osteotomy (PAO) exclusively in a borderline hip dysplasia (BHD) population to provide a contrast to published outcomes for arthroscopic surgery of the hip in BHD. We identified 42 hips in 40 patients treated between January 2009 and January 2016 with BHD defined as a lateral centre-edge angle (LCEA) of ≥ 18° but < 25°. A minimum five-year follow-up was available. Patient-reported outcomes (PROMs) including Tegner score, subjective hip value (SHV), modified Harris Hip Score (mHHS), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were assessed. The following morphological parameters were evaluated: LCEA, acetabular index (AI), α angle, Tönnis staging, acetabular retroversion, femoral version, femoroepiphyseal acetabular roof index (FEAR), iliocapsularis to rectus femoris ratio (IC/RF), and labral and ligamentum teres (LT) pathology.Aims
Methods
The primary aim of this study was to compare surgical methods (sliding hip screw (SHS) vs intramedullary nailing (IMN)) for trochanteric hip fracture in relation to death within 120 days after surgery and return to independent living. The secondary aim was to assess whether the associations between surgical method and death or ability to return to independent living varied depending on fracture subtype or other patient characteristics. A total of 27,530 individuals from the Swedish Hip Fracture Register RIKSHÖFT (SHR) aged ≥ 70 years, admitted to hospital between 1 January 2014 and 31 December 2019 with trochanteric hip fracture, were included. Within this cohort, 12,041 individuals lived independently at baseline, had follow-up information in the SHR, and were thus investigated for return to independent living. Death within 120 days after surgery was analyzed using Cox regression with SHS as reference and adjusted for age and fracture type. Return to independent living was analyzed using logistic regression adjusted for age and fracture type. Analyses were repeated after stratification by fracture type, age, and sex.Aims
Methods
Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model.Aims
Methods
With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases. A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS).Aims
Methods
Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions. We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model.Aims
Methods
A typical pattern of blood loss associated with total hip arthroplasty (THA) is 200 ml intraoperatively and 1.3 l in the first 48 postoperative hours. Tranexamic acid (TXA) is most commonly given as a single preoperative dose only and is often withheld from patients with a history of thromboembolic disease as they are perceived to be “high-risk” with respect to postoperative venous thromboembolism (VTE). The TRanexamic ACid for 24 hours trial (TRAC-24) aimed to identify if an additional 24-hour postoperative TXA regime could further reduce blood loss beyond a once-only dose at the time of surgery, without excluding these high-risk patients. TRAC-24 was a prospective, phase IV, single centre, open label, parallel group, randomized controlled trial (RCT) involving patients undergoing primary unilateral elective THA. The primary outcome measure was the indirect calculated blood loss (IBL) at 48 hours. The patients were randomized into three groups. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional oral regime for 24 hours postoperatively, group 2 only received the intraoperative dose, and group 3 did not receive any TXA.Aims
Methods
Advances in surgical technique and implant design may influence the incidence and mechanism of failure resulting in revision total hip arthroplasty (rTHA). The purpose of the current study was to characterize aetiologies requiring rTHA, and to determine whether temporal changes existed in these aetiologies over a ten-year period. All rTHAs performed at a single institution from 2009 to 2019 were identified. Demographic information and mode of implant failure was obtained for all patients. Data for rTHA were stratified into two time periods to assess for temporal changes: 2009 to 2013, and 2014 to 2019. Operative reports, radiological imaging, and current procedural terminology (CPT) codes were cross-checked to ensure the accurate classification of revision aetiology for each patient.Aims
Methods
Dislocation remains a significant complication after total hip arthroplasty (THA), being the third leading indication for revision. We present a series of acetabular revision using a dual mobility cup (DMC) and compare this with our previous series using the posterior lip augmentation device (PLAD). A retrospective review of patients treated with either a DMC or PLAD for dislocation in patients with a Charnley THA was performed. They were identified using electronic patient records (EPR). EPR data and radiographs were evaluated to determine operating time, length of stay, and the incidence of complications and recurrent dislocation postoperatively.Aims
Methods
Our rural orthopaedic service has undergone service restructure during the COVID-19 pandemic in order to sustain hip fracture care. All adult trauma care has been centralised to the Royal Shrewsbury Hospital for assessment and medical input, before transferring those requiring operative intervention to the Robert Jones and Agnes Hunt Orthopaedic Hospital. We aim to review the impact of COVID-19 on hip fracture workload and service changes upon management of hip fractures. We reviewed our prospectively maintained trust database and National Hip Fracture Database records for the months of March and April between the years 2016 and 2020. Our assessment included fracture pattern (intrascapular vs extracapsular hip fracture), treatment intervention, length of stay and mortality.Aims
Methods
Leucocyte esterase (LE) has been shown to be an accurate marker of prosthetic joint infection (PJI), and has been proposed as an alternative to frozen section (FS) histology for intraoperative diagnosis. In this study, the intraoperative assessment of LE was compared with FS histology for the diagnosis of prosthetic hip infection. A total of 119 patients undergoing revision total hip arthroplasty (THA) between June 2015 and December 2017 were included in the study. There were 56 men and 63 women with a mean age of 66.2 years (27 to 88). Synovial fluid was collected before arthrotomy for the assessment of LE using enzymatic colourimetric strips. Between five and six samples were stained with haematoxylin and eosin for FS histology, and considered suggestive of infection when at least five polymorphonuclear leucocytes were found in five high-power fields.Aims
Patients and Methods
We investigated the reliability of the cobalt-chromium (CoCr) synovial joint fluid ratio (JFR) in identifying the presence of a severe aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) response and/or suboptimal taper performance (SOTP) following metal-on-metal (MoM) hip arthroplasty. We then examined the possibility that the CoCr JFR may influence the serum partitioning of Co and Cr. For part A, we included all revision surgeries carried out at our unit with the relevant data, including volumetric wear analysis, joint fluid (JF) Co and Cr concentrations, and ALVAL grade (n = 315). Receiver operating characteristic curves were constructed to assess the reliability of the CoCr JFR in identifying severe ALVAL and/or SOTP. For part B, we included only patients with unilateral prostheses who had given matched serum and whole blood samples for Co and Cr analysis (n = 155). Multiple regression was used to examine the influence of JF concentrations on the serum partitioning of Co and Cr in the blood.Objectives
Methods