Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 15 - 15
1 Jun 2012
Cheng K Rumley A Campbell A Lowe G
Full Access

The aim of this study was to examine the effects of cement in total knee arthroplasty on markers of inflammation and endothelial dysfunction, as surrogate markers for enhanced risk of vascular disease or precipitation of acute vascular events post-operatively. A total of 36 patients were recruited, with 18 in each of the cemented and uncemented groups. Both groups were matched for age, sex and body mass index. Venous blood samples were taken pre-operatively, day 1 and day 7 post-operatively. Serum levels of interleukin 6 (IL6), tumour necrosis factor (TNF□?, e-selectin, Von willebrand factor (vWF), tissue plasminogen activator (tPA) and soluble CD40 ligand were analysed. Also, real time analysis of the expression of CD40 and CD14/CD42a aggregates on monocytes was carried out using flow cytometry. Patients were excluded from the study if there were signs of either superficial or deep infection. The only variable to demonstrate a significant difference between the two groups was the CD1442a count. There was a significant difference in the first 24 hours (p=0.00) and from day 1 to day 7 (p=0.02). Our study suggests that the use of bone cement causes a significant rise in CD1442a count which has been linked to atherothrombosis and acute coronary syndromes. These changes may explain the increased incidence of venous thrombosis and thromboembolism post-operatively. However more research required in this field to delineate the exact pathways involved


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 20 - 20
17 Nov 2023
van Duren B France J Berber R Matar H James P Bloch B
Full Access

Abstract. Objective. Up to 20% of patients can remain dissatisfied following TKR. A proportion of TKRs will need early revision with aseptic loosening the most common. The ATTUNE TKR was introduced in 2011 as successor to its predicate design The PFC Sigma (DePuy Synthes, Warsaw, In). However, following reports of early failures of the tibial component there have been ongoing concerns of increased loosening rates with the ATTUNE TKR. In 2017 a redesigned tibial baseplate (S+) was introduced, which included cement pockets and an increased surface roughness to improve cement bonding. Given the concerns of early tibial loosening with the ATTUNE knee system, this study aimed to compare revision rates and those specific to aseptic loosening of the ATTUNE implant in comparison to an established predicate as well as other implant designs used in a high-volume arthroplasty centre. Methods. The Attune TKR was introduced to our unit in December 2011. Prior to this we routinely used a predicate design with an excellent long-term track record (PFC Sigma) which remains in use. In addition, other designs were available and used as per surgeon preference. Using a prospectively maintained database, we identified 10,202 patients who underwent primary cemented TKR at our institution between 01/04/2003–31/03/2022 with a minimum of 1 year follow-up (Mean 8.4years, range 1–20years): 1) 2406 with ATTUNE TKR (of which 557 were S+) 2) 4652 with PFC TKR 3) 3154 with other cemented designs. All implants were cemented using high viscosity cement. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Matched cohorts were selected from the ATTUNE subsets (original and S+) and PFC groups using the nearest neighbor method for radiographic analysis. Radiographs were assessed to compare the presence of radiolucent lines in the Attune S+, standard Attune, and PFC implants. Results. At a mean of 8.4 years follow-up, 308 implants underwent revision equating to 3.58 revisions per 1000 implant-years. The lowest risk of revision was noted in the ATTUNE cohort with 2.98 per 1000-implant-years where the PFC and All Other Implant groups were 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision across all cemented implants with 76% (65/88) of involving loosening of the tibia. Survival analysis comparing the ATTUNE cohort to the PFC and All Other Cemented Implant cohorts showed no significant differences for: all-cause revision, aseptic loosening, or tibial loosening (p=0.15,0.77,0.47). Radiolucent lines were detected in 4.6%, 5.8%, and 5.0% of the ATTUNE S+, standard ATTUNE, and PFC groups respectively. These differences were not significant. Conclusion. This study represents the largest non-registry review of the original and S+ ATTUNE TKR in comparison to its predicate design as well as other cemented implants. There appears to be no significant increased revision rate for all-cause revision or aseptic loosening. Radiographic analysis also showed no significant difference in peri-implant radiolucency. It appears that concerns of early loosening may be unfounded. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 24 - 24
14 Nov 2024
Petersen ET Linde KN Burvil CCH Rytter S Koppens D Dalsgaard J Hansen TB Stilling M
Full Access

Introduction. Knee osteoarthritis often causes malalignment and altering bone load. This malalignment is corrected during total knee arthroplasty surgery, balancing the ligaments. Nonetheless, preoperative gait patterns may influence postoperative prosthesis load and bone support. Thus, the purpose is to investigate the impact of preoperative gait patterns on postoperative femoral and tibial component migration in total knee arthroplasty. Method. In a prospective cohort study, 66 patients with primary knee osteoarthritis undergoing cemented Persona total knee arthroplasty were assessed. Preoperative knee kinematics was analyzed through dynamic radiostereometry and motion capture, categorizing patients into four homogeneous gait patterns. The four subgroups were labeled as the flexion group (n=20), the abduction (valgus) group (n=17), the anterior drawer group (n=10), and the tibial external rotation group (n=19). The femoral and tibial component migration was measured using static radiostereometry taken supine on the postoperative day (baseline) and 3-, 12-, and 24- months after surgery. Migration was evaluated as maximum total point motion. Result. Of the preoperatively defined four subgroups, the abduction group with a valgus-characterized gait pattern exhibited the highest migration for both the femoral (1.64 mm (CI95% 1.25; 2.03)) and tibial (1.21 mm (CI95% 0.89; 1.53)) components at 24-month follow-up. For the femoral components, the abduction group migrated 0.6 mm (CI95% 0.08; 1.12) more than the external rotation group at 24 months. For the tibial components, the abduction group migrated 0.43 mm (CI95% 0.16; 0.70) more than the external rotation group at 3 months. Furthermore, at 12- and 24-months follow-up the abduction group migrated 0.39 mm (95%CI 0.04; 0.73) and 0.45 mm (95%CI 0.01; 0.89) more than the flexion group, respectively. Conclusion. A preoperative valgus-characterized gait pattern seems to increase femoral and tibial component migration until 2 years of follow-up. This suggests that the implant fixation depends on load distributions originating from specific preoperative gait patterns


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 55 - 55
1 Apr 2018
Yabuno K Sawada N Hirohaku D
Full Access

Introduction. With the development of 3D printing technology, there are many different types of PSI in the world. The accuracy of patient specific instrumentation (PSI) in primary total knee arthroplasty (TKA) is dependent on appropriate placement of the cutting blocks. However, previous reports on one type of PSI measured the difference between postoperative prosthetic alignment and postoperative mechanical axis and thus these reports did not evaluate intraoperative comparison of PSIs between two different designs. The purpose of this study was to evaluate the intraoperative accuracy of two different designed PSIs (My knee, Medacta International, Castel San Pietro, Switzerland) with two examiners using CT free navigation system (Stryker, Mahwar, NJ, USA) in regards to sagittal and coronal alignment. Methods. We enrolled 78knees (66 patients) with a primary cemented TKA using two different designed CT-based PSIs (My knee, Medacta International, Castel San Pietro, Switzerland). All operations were performed by two senior surgeons who have experience with greater than 500 TKAs and greater than 200 navigated TKAs. Two examiners were same two surgeons. The study period was between June 2015 and November 2016. The local ethics' committee approved the study prior to its initiation, and informed consent was obtained from all patients. After placement of the PSI on the femur and tibia, the position of the PSI was evaluated by s intraoperative navigation. Two examiners placed two different types (STD(standard) and MIS(minimum invasive surgery)) of PSI on same joint. As required by the PSI, only soft- tissue was removed and osteophytes were left in place. Femoral MIS PSI was required partial remove of lateral cartilage. For the femur, the coronal position in relation to the mechanical axis were documented. For the tibia, the coronal alignment and the tibial slope were documented. Of note, intraoperative modifications to the PSI were not made based upon the results of the navigation. Rather, the findings of the intraoperative navigation were simply documented. Results. The mean age of the cohort was 72.9±7.5years (range, 55–85years). The study included 11men and 55women, with a mean height of 151±8.2cm (range, 135–175cm), mean weight of 59.4±4.3kg (range, 42–82kg), and a mean of Body Mass Index of 25.9±3.6 (range, 17.2–36.4). HKA angle (supine position) measured by CT was 170.8 ±4.4 degree(range, 162.5–182degree). Diagnosis was osteoarthritis in all patient. There was no statistically significant difference in PSI position alignment for femoral flexion, tibial coronal angle, tibial slope between the two groups with two examiners. However, the intraoperative coronal position using the femoral STD PSI significantly deviated from using femoral MIS PSI from both examiners. (PSI vs. MIS, examiner1 p = 0.02, examiner2 p=0.04)


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 436 - 444
1 Apr 2000
van Loon CJM de Waal Malefijt MC Buma P Stolk PWT Verdonschot N Tromp AM Huiskes R Barneveld A

The properties of impacted morsellised bone graft (MBG) in revision total knee arthroplasty (TKA) were studied in 12 horses. The left hind metatarsophalangeal joint was replaced by a human TKA. The horses were then randomly divided into graft and control groups. In the graft group, a unicondylar, lateral uncontained defect was created in the third metatarsal bone and reconstructed using autologous MBG before cementing the TKA. In the control group, a cemented TKA was implanted without the bone resection and grafting procedure. After four to eight months, the animals were killed and a biomechanical loading test was performed with a cyclic load equivalent to the horse’s body-weight to study mechanical stability. After removal of the prosthesis, the distal third metatarsal bone was studied radiologically, histologically and by quantitative and micro CT. Biomechanical testing showed that the differences in deformation between the graft and the control condyles were not significant for either elastic or time-dependent deformations. The differences in bone mineral density (BMD) between the graft and the control condyles were not significant. The BMD of the MBG was significantly lower than that in the other regions in the same limb. Micro CT showed a significant difference in the degree of anisotropy between the graft and host bone, even although the structure of the area of the MBG had trabecular orientation in the direction of the axial load. Histological analysis revealed that all the grafts were revascularised and completely incorporated into a new trabecular structure with few or no remnants of graft. Our study provides a basis for the clinical application of this technique with MBG in revision TKA