Advertisement for orthosearch.org.uk
Results 1 - 20 of 35
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1022 - 1026
1 Aug 2006
Langlais F Belot N Ropars M Lambotte JC Thomazeau H

We evaluated the long-term fixation of 64 press-fit cemented stems of constrained total knee prostheses in 32 young patients with primary malignant bone tumours. Initial stable fixation, especially in rotation, was achieved by precise fit of the stem into the reamed endosteum, before cementation. Complementary fixation, especially in migration and rotation, was obtained by pressurised antibiotic-loaded cement. The mean age at operation was 33 years (13 to 61). No patient was lost to follow-up; 13 patients died and the 19 survivors were examined at a mean follow-up of 12.5 years (4 to 21). Standard revision press-fit cemented stems were used on the side of the joint which was not involved with tumour (26 tibial and six femoral), on this side there was no loosening or osteolysis and stem survival was 100%. On the reconstruction side, custom-made press-fit stems were used and the survival rate, with any cause for revision as an end point, was 88%, but 97% for loosening or osteolysis. This longevity is similar to that achieved at 20 years with the Charnley-Kerboull primary total hip replacement with press-fit cemented femoral components. We recommend this type of fixation when extensive reconstruction of the knee is required. It may also be suitable for older patients requiring revision of a total knee replacement or in difficult situations such as severe deformity and complex articular fractures


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 458 - 462
1 Apr 2020
Limberg AK Tibbo ME Pagnano MW Perry KI Hanssen AD Abdel MP

Aims. Varus-valgus constrained (VVC) implants are often used during revision total knee arthroplasty (TKA) to gain coronal plane stability. However, the increased mechanical torque applied to the bone-cement interface theoretically increases the risk of aseptic loosening. We assessed mid-term survivorship, complications, and clinical outcomes of a fixed-bearing VVC device in revision TKAs. Methods. A total of 416 consecutive revision TKAs (398 patients) were performed at our institution using a single fixed-bearing VVC TKA from 2007 to 2015. Mean age was 64 years (33 to 88) with 50% male (199). Index revision TKA diagnoses were: instability (n = 122, 29%), aseptic loosening (n = 105, 25%), and prosthetic joint infection (PJI) (n = 97, 23%). All devices were cemented on the epiphyseal surfaces. Femoral stems were used in 97% (n = 402) of cases, tibial stems in 95% (n = 394) of cases; all were cemented. In total, 93% (n = 389) of cases required a stemmed femoral and tibial component. Femoral cones were used in 29%, and tibial cones in 40%. Survivorship was assessed via competing risk analysis; clinical outcomes were determined using Knee Society Scores (KSSs) and range of movement (ROM). Mean follow-up was four years (2 to 10). Results. The five-year cumulative incidence of subsequent revision for aseptic loosening and instability were 2% (95% confidence interval (CI) 0.2 to 3, number at risk = 154) and 4% (95% CI 2 to 6, number at risk = 153), respectively. The five-year cumulative incidence of any subsequent revision was 14% (95% CI 10 to 18, number at risk = 150). Reasons for subsequent revision included PJI (n = 23, of whom 12 had previous PJI), instability (n = 13), and aseptic loosening (n = 11). The use of this implant without stems was found to be a significant risk factor for subsequent revision (hazard ratio (HR) 7.58 (95% CI 3.98 to 16.03); p = 0.007). KSS improved from 46 preoperatively to 81 at latest follow-up (p < 0.001). ROM improved from 96° prerevision to 108° at latest follow-up (p = 0.016). Conclusion. The cumulative incidence of subsequent revision for aseptic loosening and instability was very low at five years with this fixed-bearing VVC implant in revision TKAs. Routine use of cemented and stemmed components with targeted use of metaphyseal cones likely contributed to this low rate of aseptic loosening. Cite this article: Bone Joint J 2020;102-B(4):458–462


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 150 - 157
1 Jun 2021
Anderson LA Christie M Blackburn BE Mahan C Earl C Pelt CE Peters CL Gililland J

Aims. Porous metaphyseal cones can be used for fixation in revision total knee arthroplasty (rTKA) and complex TKAs. This metaphyseal fixation has led to some surgeons using shorter cemented stems instead of diaphyseal engaging cementless stems with a potential benefit of ease of obtaining proper alignment without being beholden to the diaphysis. The purpose of this study was to evaluate short term clinical and radiographic outcomes of a series of TKA cases performed using 3D-printed metaphyseal cones. Methods. A retrospective review of 86 rTKAs and nine complex primary TKAs, with an average age of 63.2 years (SD 8.2) and BMI of 34.0 kg/m. 2. (SD 8.7), in which metaphyseal cones were used for both femoral and tibial fixation were compared for their knee alignment based on the type of stem used. Overall, 22 knees had cementless stems on both sides, 52 had cemented stems on both sides, and 15 had mixed stems. Postoperative long-standing radiographs were evaluated for coronal and sagittal plane alignment. Adjusted logistic regression models were run to assess malalignment hip-knee-ankle (HKA) alignment beyond ± 3° and sagittal alignment of the tibial and femoral components ± 3° by stem type. Results. No patients had a revision of a cone due to aseptic loosening; however, two had revision surgery due to infection. In all, 26 (27%) patients had HKA malalignment; nine (9.5%) patients had sagittal plane malalignment, five (5.6%) of the tibia, and four (10.8%) of the femur. After adjusting for age, sex, and BMI, there was a significantly increased risk for malalignment when a cone was used and both the femur and tibia had cementless compared to cemented stems (odds ratio 3.19, 95% confidence interval 1.01 to 10.05). Conclusion. Porous 3D-printed cones provide excellent metaphyseal fixation. However, these central cones make the use of offset couplers difficult and may generate malalignment with cementless stems. We found 3.19-times higher odds of malalignment in our TKAs performed with metaphyseal cones and both femoral and tibial cementless stems. Cite this article: Bone Joint J 2021;103-B(6 Supple A):150–157


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 116 - 122
1 Jun 2020
Bedard NA Cates RA Lewallen DG Sierra RJ Hanssen AD Berry DJ Abdel MP

Aims. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11). Results. Survival free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at five years. Survival free from any revision of the construct and free from any reoperation were 92% and 73% at five years, respectively. A total of six patients (six TKAs, 17%) required a further revision, four for infection or wound issues, and two for periprosthetic fracture. Radiologically, one unrevised TKA had evidence of loosening which was asymptomatic. In all unrevised TKAs the impacted diaphyseal bone graft appeared to be incorporated radiologically. Conclusion. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this technique combining diaphyseal impaction grafting with a metaphyseal cone provided near universal success in relation to implant fixation. Moreover, radiographs revealed incorporation of the bone graft and biological fixation of the cone. While long-term follow-up will be important, this technique provides an excellent option for the management of complex revision TKAs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):116–122


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 55 - 55
1 Oct 2020
Mahan C Blackburn B Anderson LA Peters CL Pelt CE Gililland JM
Full Access

Introduction. Porous metaphyseal cones are increasingly used for fixation in revision total knee arthroplasty (RTKA). Both cemented shorter length stems and longer diaphyseal engaging stems are currently utilized with metaphyseal cones with no clear evidence of superiority. The purpose of this study was to evaluate our experience with 3D printed titanium metaphyseal cones with both short cemented and longer cementless stems from a clinical and radiographic perspective. Methods. In total 136 3D printed titanium metaphyseal cones were implanted. The mean patient age was 63 and 48% were female. The mean BMI was 33 and the mean ASA class was 2.5. There were 42 femoral cones in which 28 cemented and 14 cementless stems were utilized. There were 94 tibial cones in which 67 cemented and 27 cementless stems were utilized. The choice for stem fixation was surgeon dependent and in general cones were utilized for AORI type 2 and 3 bone defects on the femur and tibia. The most common fixation scenario was short cemented stems on both the femur and tibia followed by cemented stem fixation on the tibia and cementless fixation on the femur. Clinical data such as revision, complication, and PRO was collected at last follow-up (minimum follow-up 1 year). Radiographic analysis included cone bony ingrowth and coronal and sagittal alignment on long-standing radiographs. Descriptive statistics were used to compare demographics between patients who had malalignment (HKA beyond +/− 3 degrees and flexion/extension beyond +/− 3 degrees). Adjusted logistic regression models were run to assess malalignment risk by stem type. Results. Patient reported outcomes demonstrated modest improvements with Pre-op KOOS improving from 44 pre-op to 59 post -op and PF-CAT improving from 33 to 37 post-op. PROMIS pain scores decreased significantly from 54 to 44 post-op. 36% of patients had malalignment in either the coronal or sagittal plane. Patients with malalignment were more likely to be female (66.7% vs 40.4%, p-value=0.02). After adjusting for age, sex and BMI, there was a significantly increased risk for coronal plane malalignment when both the femur and tibia had cementless compared to cemented stems (odds ratio=5.54, 95%CI=1.15, 26.80). There was no significantly increased risk when comparing patients with mixed stems to patients with cemented stems. Sagittal plane malalignment was more common with short cemented stems although both coronal plane and sagittal plane malalignment with either stem type was not associated with inferior clinical outcome. Overall cone survivorship was excellent with only two cones removed for infection. Conclusion. Metaphyseal titanium cones provide reliable fixation in revision TKA. However, PROs in this complex patient population show only modest improvement consistent with other variables such as co-morbidities and poor baseline physical function. Small cone inner diameter may adversely influence cementless stem position leading to coronal plane malalignment. Short cemented stems are subject to greater sagittal plane malalignment with no apparent influence on clinical outcome


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 165 - 170
1 Jun 2021
Larson DJ Rosenberg JH Lawlor MA Garvin KL Hartman CW Lyden E Konigsberg BS

Aims. Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components. Methods. This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss. Results. No statistically significant differences in stem length, operative side, or indications for revision were found between the two cohorts. Tibial pain at the end of the stem was present in 25.3% (16/63) of cemented stems and 25.5% (12/47) of uncemented stems (p = 1.000); 74.6% (47/63) of cemented patients and 78.7% (37/47) of uncemented patients were satisfied following revision TKA (p = 0.657). Conclusion. There were no differences in patient satisfaction, overall pain, and diaphyseal tibial pain in cemented and uncemented stemmed tibial components in revision TKA. Patient factors, rather than implant selection and surgical technique, likely play a large role in the presence of postoperative pain. Stemmed tibial components have been shown to be a possible source of pain in revision TKA. There is no difference in patient satisfaction or postoperative pain with cemented or uncemented stemmed tibial components in revision TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):165–170


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 30 - 30
1 Oct 2019
Bedard NA Cates RA Lewallen DG Hanssen AD Berry DJ Abdel MP
Full Access

Introduction. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasties (TKAs). However, if the diaphysis has been previously violated (as in revision of a failed stemmed implant), the resultant sclerotic canal can impair cemented stem fixation, which is vital for cone ingrowth and long-term fixation. We report the outcomes of our novel solution to this problem, in which impaction grafting and a cemented stem in the diaphysis was combined with an uncemented metaphyseal cone for revision TKAs with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems in a novel fashion for 35 revision TKAs. Mean age at revision TKA was 70 years, with 63% being male. Patients had a mean of 4 prior knee arthroplasty procedures. Indications for the revision with this construct were aseptic loosening (80%) and two-stage re-implantation for periprosthetic infection (PJI; 20%). Mean follow-up was 3 years. Results. Survivorship free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at 5 years. Survivorships free from any revision of the cone/impaction grafting construct and free from any reoperation were 92% and 73% at 5 years, respectively. Six knees (17%) required a reoperation (4 for infection/wound issues and 2 for periprosthetic fractures). Radiographically, 97% of cones were ingrown (1 loose cone in setting of PJI). In all but one case, impacted diaphyseal bone graft appeared to have incorporated radiographically. Conclusions. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this innovative technique combining diaphyseal impaction grafting with a metaphyseal cone provided near universal success in regards to implant fixation. Moreover, radiographs revealed incorporation of the bone graft, and ingrowth of the cones. While long-term follow-up is required, this novel technique provides an excellent option in the most difficult of revision TKAs. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 3 - 3
1 Oct 2020
Kildow BJ Patel SP Otero JE Fehring KA Curtin BM Springer BD Fehring TK
Full Access

Introduction. Debridement, Antibiotics and Implant Retention (DAIR) remains the norm for the treatment of acute periprosthetic joint infection (PJI) despite less than optimal success rates. Intraosseous (IO) administration of vancomycin has been shown to have significantly increased local bone and tissue concentrations compared to systemic antibiotics, with lower systemic antibiotic levels compared to intravenous. The purpose of this study was to evaluate if the addition of IO regional antibiotics to our protocol at the time of DAIR would improve outcomes. Methods. A retrospective review of 35 PJI TKA patients who underwent DAIR combined with IO vancomycin (500mg) was performed with minimum 12-month follow-up. 26 patients were treated for acute perioperative or acute hematogenous infections following primary TKA. Nine were treated for chronic infections with components that were considered unresectable (ie) constructs with ingrown cones, sleeves, or long cemented stems in elderly comorbid patients. Primary outcome was defined by no reoperations for infection nor clinical signs or symptoms of PJI. Results. The average follow up for acute infection was 16.5 months (range 12.1–24.2) and 15.8 months (range 12–24.8) for chronic infections with unresectable components. Overall eradication rates for acute infection was 93.1% while only 44.4% for chronic infections with unresectable components. MSIS host grade was a significant indicator of failure (p<0.001). Conclusion. The use of IO vancomycin at the time of DAIR yielded improved results compared to standard irrigation and debridement in acute periprosthetic infections. Its use in chronic infections should remain cautious. While these results are encouraging, this technique requires longer follow-up before widespread adoption


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 41 - 41
1 Oct 2018
Robertsson O Sundberg M W-Dahl A Lidgren L
Full Access

Background. The modern modular implants allow surgeons to combine different combinations of components within the same brand of which some may have completely different design. During 1999–2012 the same cemented femur component was used together with a cemented stemmed tibia baseplate and also against a cemented pegged tibia baseplate. We decided to compare the revision rate of total knee arthroplasties (TKAs) using these two tibia baseplates. Methods. This is a register study. During 1999–2012, 32,429 cemented, CR TKA's of a specific brand were reported to the Swedish Knee Arthroplasty Register (SKAR). The part numbers for the femur, tibia and insert (in modular implants) were available in 99.2% of cases. The most common combination used the cemented CR femur against a cemented stemmed baseplate in 50.3% of cases while the same CR femur was used against a cemented pegged baseplate in 8.3% of cases, mainly at two hospitals. In order to make the material more comparable, only patients having osteoarthritis (OA) were included and only TKAs using two types of regular constraint inserts and in which the patella had been left un-resurfaced. Chi-Square test was used to investigate gender distribution in the groups and t-test for the mean age at surgery. Kaplan Meier analysis and the log-rank test were used to evaluate the risk of revision until the end of 2016. A p-value <0.05 was considered statistically significant. Results. After exclusions, there were 15,287 knees with the stemmed and 2,479 with the pegged tibia baseplate. The mean follow-up time was 8.1 years (range 0–18). The proportion of women in the stemmed group was 59% and 60% in the pegged group (p=0.32) and the mean age at surgery for the groups was 69.9 years and 70.0 years, respectively (p=0.41). The cumulative revision rate (CRR) at 15 years for TKAs using the stemmed baseplate was 3.0% (95% CI: 2.6–3.5) as compared to 5.8% (95% CI: 4.0–8.3) for the pegged baseplate (p=0.003). When only revisions for loosening were considered, the CRR was respectively 0.6% (95% CI: 0.4–0. 9) and 3. 8% (95% CI: 2.3–6.3) (p<0.001). Conclusion. We found that TKAs using the pegged base plate had significantly higher risk for revision, both for all reasons as well as for only loosening. As the pegged baseplate surgeries were performed mostly at only two hospitals it is possible that local factors are to blame. However, considering that after stopping using the pegged baseplate, the two hospitals performed least as well as other hospitals using the same brand we think it is likely that the pegged plate has a higher risk of loosening and that our observation warrants that the performance of pegged plates is investigated in other registers


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 53 - 53
1 Oct 2020
Larson D Rosenberg J Lawlor M Garvin KL Hartman C Lyden E Konigsberg B
Full Access

Introduction. Revision total knee arthroplasty (TKA) is becoming increasingly common in the United States as the population ages and larger numbers of primary TKA are performed in younger individuals. Cemented or uncemented tibial stems are frequently used in revision cases. Decreased clinical outcomes and patient satisfaction have been described for revision TKA. This study aims to determine if the presence of overall pain and tibial pain at the end of the stem differs between cemented and uncemented tibial stems in revision TKA. Methods. This was a retrospective cohort study comparing patients who underwent revision TKA utilizing cemented or uncemented tibial stems in a 15-year period at a single institution with at least two-year follow-up. Exclusion criteria included age under 18, isolated revisions of the femoral component or polyethylene exchanges, lack of preoperative or postoperative imaging, insufficient operative or implant records available for electronic chart review, revision procedures performed at outside facilities, patients who were deceased at the time of survey administration, refusal to participate in the study, and failure to return the mailed survey or respond to a telephone follow-up questionnaire. Radiographic analysis included calculation of the percentage of the tibial canal filled with the implant, as well as measurement of the diameter of the tibial stem. Radiographs were also reviewed for evidence of cavitary defects, pedestal formation, radiolucent lines, and periprosthetic fractures. Mailed surveys addressing overall pain, tibial pain, and satisfaction were analyzed using Fisher's exact test and the independent sample t-test. Logistic regression was used to adjust for age, gender, and preoperative bone loss. Results. A total of 110 patients were included (63 cemented and 47 uncemented stems). No statistically significant differences in stem length, operative side, or indications for revision were found. The uncemented group had a significantly higher percent canal fill (p < 0.0001). Tibial pain at the end of the stem was present in 25.3% of cemented stems and 25.5% of uncemented stems (p = 1.00). There was a trend towards more overall pain in the uncemented cohort, but this did not reach statistical significance. Only 74.6% of cemented patients and 78.7% of uncemented patients were satisfied following revision TKA (p = 0.66). Conclusion. The data supports our hypothesis that there are no differences in end-of-stem pain or overall pain between cemented and uncemented tibial stems in revision TKA. High rates of dissatisfaction were noted in both cohorts postoperatively, consistent with previous literature. Patient factors likely play a large role in the presence of postoperative pain. These factors should be further evaluated in future studies in an effort to reduce pain and improve patient satisfaction


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims

Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis).

Methods

Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims

The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes.

Methods

A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims

Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.

Methods

This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 73 - 73
1 Oct 2019
Fehring KA Wyles CC Trousdale RT
Full Access

Introduction. In the setting of periprosthetic joint infection, the complete removal of implants and cement can be challenging with well-fixed, cemented implants about the knee. This can get especially complex in the setting of long cemented femoral stems. Osteotomies are well described in the proximal femur and tibia for removal of implants and cement. There is little information available on distal femoral osteotomies to facilitate knee implant and retained cement removal. Methods. We describe a novel anterolateral oblique distal femoral osteotomy for the removal of well-fixed, cemented components during resection knee arthroplasty that preserves vascularity to the osteotomized segment. Cadaveric anatomic vascular injection studies were performed to document vascularity of the osteotomized segment. Clinical examples, and results will be presented. Results. Anatomic vascular studies documented preserved vascularity to the osteotomized segment. In two patients intramedullary infected implant and cement was completely removed. At reimplantation and final followup the osteotomy was radiographically healed, implants well fixed, and no recurrent infections were noted. Conclusions. This osteotomy appears to be useful when removing well fixed, cemented femoral components during periprosthetic infection. Vascularity and union was preserved and obtained in all patients. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims

This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant.

Methods

A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 93 - 95
1 Nov 2014
Gehrke T Kendoff D Haasper C

The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (> 20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):93–5


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 185 - 190
1 Jun 2021
Kildow BJ Patel SP Otero JE Fehring KA Curtin BM Springer BD Fehring TK

Aims

Debridement, antibiotics, and implant retention (DAIR) remains one option for the treatment of acute periprosthetic joint infection (PJI) despite imperfect success rates. Intraosseous (IO) administration of vancomycin results in significantly increased local bone and tissue concentrations compared to systemic antibiotics alone. The purpose of this study was to evaluate if the addition of a single dose of IO regional antibiotics to our protocol at the time of DAIR would improve outcomes.

Methods

A retrospective case series of 35 PJI TKA patients, with a median age of 67 years (interquartile range (IQR) 61 to 75), who underwent DAIR combined with IO vancomycin (500 mg), was performed with minimum 12 months' follow-up. A total of 26 patients with primary implants were treated for acute perioperative or acute haematogenous infections. Additionally, nine patients were treated for chronic infections with components that were considered unresectable. Primary outcome was defined by no reoperations for infection, nor clinical signs or symptoms of PJI.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 281 - 288
1 Nov 2012
Conlisk N Gray H Pankaj P Howie CR

Objectives. Orthopaedic surgeons use stems in revision knee surgery to obtain stability when metaphyseal bone is missing. No consensus exists regarding stem size or method of fixation. This in vitro study investigated the influence of stem length and method of fixation on the pattern and level of relative motion at the bone–implant interface at a range of functional flexion angles. Methods. A custom test rig using differential variable reluctance transducers (DVRTs) was developed to record all translational and rotational motions at the bone–implant interface. Composite femurs were used. These were secured to permit variation in flexion angle from 0° to 90°. Cyclic loads were applied through a tibial component based on three peaks corresponding to 0°, 10° and 20° flexion from a normal walking cycle. Three different femoral components were investigated in this study for cementless and cemented interface conditions. Results. Relative motions were found to increase with flexion angle. Stemmed implants reduced relative motions in comparison to stemless implants for uncemented constructs. Relative motions for cemented implants were reduced to one-third of their equivalent uncemented constructs. Conclusions. Stems are not necessary for cemented implants when the metaphyseal bone is intact. Short cemented femoral stems confer as much stability as long uncemented stems


Bone & Joint Research
Vol. 10, Issue 8 | Pages 467 - 473
2 Aug 2021
Rodríguez-Collell JR Mifsut D Ruiz-Sauri A Rodríguez-Pino L González-Soler EM Valverde-Navarro AA

Aims

The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray.

Methods

In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and measured cement layer thickness at both levels of the resected surface of the epiphysis and the endomedular metaphyseal level.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 123 - 128
1 Jun 2020
Martin JR Geary MB Ransone M Macknet D Fehring K Fehring T

Aims

Aseptic loosening of the tibial component is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include an isolated tibial revision or full component revision. A full component revision is frequently selected by surgeons unfamiliar with the existing implant or who simply wish to “start again”. This option adds morbidity compared with an isolated tibial revision. While isolated tibial revision has a lower morbidity, it is technically more challenging due to difficulties with exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options.

Methods

Patients undergoing revision TKA for isolated aseptic tibial loosening between 2012 and 2017 were identified. Those with revision implants or revised for infection, instability, osteolysis, or femoral component loosening were excluded. A total of 164 patients were included; 88 had an isolated tibial revision and 76 had revision of both components despite only having a loose tibial component. The demographics and clinical and radiological outcomes were recorded.