Advertisement for orthosearch.org.uk
Results 1 - 20 of 48
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1347 - 1354
1 Oct 2016
Palan J Smith MC Gregg P Mellon S Kulkarni A Tucker K Blom AW Murray DW Pandit H

Aims. Periprosthetic fracture (PF) after primary total hip arthroplasty (THA) is an uncommon but potentially devastating complication. This study aims to investigate the influence of cemented stem designs on the risk of needing a revision for a PF. Patients and Methods. We analysed data on 257 202 primary THAs with cemented stems and 390 linked first revisions for PF recorded in the National Joint Registry (NJR) of England, Wales and Northern Ireland to determine if a cemented femoral stem brand was associated with the risk of having revision for a PF after primary THA. All cemented femoral stem brands with more than 10 000 primary operations recorded in the NJR were identified. The four most commonly used cemented femoral stems were the Exeter V40 (n = 146 409), CPT (n = 24 300), C-Stem (n = 15 113) and Charnley (n = 20 182). We compared the revision risk ratios due to PF amongst the stems using a Poisson regression model adjusting for patient factors. Compared with the Exeter V40, the age, gender and ASA grade adjusted revision rate ratio was 3.89 for the cemented CPT stem (95% confidence interval (CI) 3.07 to 4.93), 0.89 for the C-Stem (95% CI 0.57 to 1.41) and 0.41 for the Charnley stem (95% CI 0.24 to 0.70). Conclusions. The limitations of the study include incomplete data capture, analysis of only PF requiring revision and that observation does not imply causality. Nevertheless, this study demonstrates that the choice of a cemented stem may influence the risk of revision for PF. Cite this article: Bone Joint J 2016;98-B:1347–54


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 577 - 582
1 May 2009
Duncan WW Hubble MJW Howell JR Whitehouse SL Timperley AJ Gie GA

The removal of well-fixed bone cement from the femoral canal during revision of a total hip replacement (THR) can be difficult and risks the loss of excessive bone stock and perforation or fracture of the femoral shaft. Retaining the cement mantle is attractive, yet the technique of cement-in-cement revision is not widely practised. We have used this procedure at our hospital since 1989. The stems were removed to gain a better exposure for acetabular revision, to alter version or leg length, or for component incompatibility.

We studied 136 hips in 134 patients and followed them up for a mean of eight years (5 to 15). A further revision was required in 35 hips (25.7%), for acetabular loosening in 26 (19.1%), sepsis in four, instability in three, femoral fracture in one and stem fracture in one. No femoral stem needed to be re-revised for aseptic loosening.

A cement-in-cement revision of the femoral stem is a reliable technique in the medium term. It also reduces the risk of perforation or fracture of the femoral shaft.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 573 - 576
1 Jul 1998
Howie DW Middleton RG Costi K

We have compared prospectively the incidence of loosening of 20 femoral stems with a matt surface with that of 20 polished stems of an otherwise identical tapered, non-modular design of Exeter hip replacement. The stems were inserted using the same technique at operation and radiographs showed no difference in the adequacy of the cement mantle or of fixation. All the patients were reviewed regularly and none was lost to follow-up.

After a minimum follow-up of nine years, four matt but no polished stems had been revised for aseptic loosening. Polished stems subsided slightly within the cement mantle early, but did not loosen.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 299 - 305
1 Mar 2014
Bell KR Clement ND Jenkins PJ Keating JF

We performed a case–control study to compare the rates of further surgery, revision and complications, operating time and survival in patients who were treated with either an uncemented hydroxyapatite-coated Corail bipolar femoral stem or a cemented Exeter stem for a displaced intracapsular fracture of the hip. The mean age of the patients in the uncemented group was 82.5 years (53 to 97) and in the cemented group was 82.7 years (51 to 99) We used propensity score matching, adjusting for age, gender and the presence or absence of dementia and comorbidities, to produce a matched cohort receiving an Exeter stem (n = 69) with which to compare the outcome of patients receiving a Corail stem (n = 69). The Corail had a significantly lower all-cause rate of further surgery (p = 0.016; odds ratio (OR) 0.18, 95% CI 0.04 to 0.84) and number of hips undergoing major further surgery (p = 0.029; OR 0.13, 95% CI 0.01 to 1.09). The mean operating time was significantly less for the Corail group than for the cemented Exeter group (59 min [12 to 136] vs 70 min [40 to 175], p = 0.001). The Corail group also had a lower risk of a peri-prosthetic fracture (p = 0.042; OR 0.19, 95% CI 0.01 to 1.42) . There was no difference in the mortality rate between the groups. There were significantly fewer complications in the uncemented group, suggesting that the use of this stem would result in a decreased rate of morbidity in these frail patients. Whether this relates to an improved functional outcome remains unknown.

Cite this article: Bone Joint J 2014;96-B:299–305.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 921 - 927
1 Jul 2005
Glyn-Jones S Gill HS Beard DJ McLardy-Smith P Murray DW

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability.

Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2°, sd 0.42°) and internally rotate (mean 1.28°, sd 0.99°). The CPS-Plus showed no significant valgus rotation (mean 0.2°, sd 0.42°) or internal rotation (mean −0.03°, sd 0.75°). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 974 - 978
1 Sep 2004
Thomas SR Shukla D Latham PD

Cemented titanium stems in hip arthroplasty are associated with proximal cement-stem debonding and early failure. This was well publicised with the 3M Capital hip. However, corrosion in this setting has been reported with only one stem design and is less widely accepted.

We present a series of 12 cemented titanium Furlong Straight Stems which required revision at a mean of 78 months for thigh pain. At revision the stems were severely corroded in a pattern which was typical of crevice corrosion. Symptoms were eliminated after revision to an all-stainless steel femoral prosthesis of the same design. We discuss the likely causes for the corrosion. The combination of a titanium stem and cement appears to facilitate crevice corrosion.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 838 - 842
1 Aug 2001
Chambers IR Fender D McCaskie AW Reeves BC Gregg PJ

The radiological features of the cement mantle around total hip replacements (THRs) have been used to assess aseptic loosening. In this case-control study we investigated the risk of failure of THR as predictable by a range of such features using data from patients recruited to the Trent Regional Arthroplasty Study (TRAS).

An independent radiological assessment was undertaken on Charnley THRs with aseptic loosening within five years of surgery and on a control group from the TRAS database. Chi-squared tests were used to test the probability of obtaining the observed data by chance, and odds ratios were calculated to estimate the strength of association for different features.

Several features were associated with a clinically important increase (> twofold) in the risk of loosening, which was statistically significant for four features (p < 0.01). Inadequate cementation (Barrack C and D grades) was the most significant feature, with an estimated odds ratio of 9.5 (95% confidence interval 3.2 to 28.4, p < 0.0001) for failure.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 46 - 52
1 Jul 2021
McGoldrick NP Fischman D Nicol GM Kreviazuk C Grammatopoulos G Beaulé PE

Aims. The aim of this study was to radiologically evaluate the quality of cement mantle and alignment achieved with a polished tapered cemented femoral stem inserted through the anterior approach and compared with the posterior approach. Methods. A comparative retrospective study of 115 consecutive hybrid total hip arthroplasties or cemented hemiarthroplasties in 110 patients, performed through anterior (n = 58) or posterior approach (n = 57) using a collarless polished taper-slip femoral stem, was conducted. Cement mantle quality and thickness were assessed in both planes. Radiological outcomes were compared between groups. Results. No significant differences were identified between groups in Barrack grade on the anteroposterior (AP) (p = 0.640) or lateral views (p = 0.306), or for alignment on the AP (p = 0.603) or lateral views (p = 0.254). An adequate cement mantle (Barrack A or B) was achieved in 77.6% (anterior group, n = 45) and in 86% (posterior group, n = 49), respectively. Multivariate analysis revealed factors associated with unsatisfactory cement mantle (Barrack C or D) included higher BMI, left side, and Dorr Type C morphology. A mean cement mantle thickness of ≥ 2 mm was achieved in all Gruen zones for both approaches. The mean cement mantle was thicker in zone 7 (p < 0.001) and thinner in zone 9 for the anterior approach (p = 0.032). Incidence of cement mantle defects between groups was similar (6.9% (n = 4) vs 8.8% (n = 5), respectively; p = 0.489). Conclusion. An adequate cement mantle and good alignment can be achieved using a collarless polished tapered femoral component inserted through the anterior approach. Cite this article: Bone Joint J 2021;103-B(7 Supple B):46–52


Introduction. In the United States, cementless femoral fixation remains the dominant mode of fixation for femoral neck fractures, despite strong worldwide registry data that supports cemented fixation. The reason for this discrepancy remains unknown, controversial and often difficult to compare due to multiple variables. The purpose of this study was to evaluate a matched cohort of patients undergoing arthroplasty for femoral neck fractures and assess outcomes of revisions, periprosthetic fractures and mortality. Methods. This is an exact matched cohort study. Cemented fixation cases were exact matched to cementless fixation cases in a 1:1 fashion based on age, sex and Charlson Comorbidity Index (CCI). Outcome variables included: revision for periprosthetic fracture; all cause revision and mortality at any time point; all cause revision and mortality within 1-year and within 90-days. The primary independent variable was femoral fixation (cemented, cementless) and covariates included race (black, white, other), ethnicity (hispanic, non-hispanic), teaching status (minor, major, nonteaching) and bedsize (1–99, 100–399, >=400). Chi-square tests and multivariable logistic regression models were used for statistical analysis. Results. A total of 64,283 femoral neck fractures were evaluated. 17,138 cementless femoral stems were matched exactly to cemented femoral stems based on age, gender and Charleston comorbidity index (CCI). In the multivariate logistic regression analysis, compared to cementless femoral fixation, cemented fixation was associated with a 20% reduction in overall revision (OR 0.796, 0.675–0.939), a 30% reduction in revision at 1 year (OR: 0.709, 0.589–0.854) and a 86% reduction in revision for periprosthetic fracture (OR: 0.144, 0.07–0.294). However, cemented stem fixation was associated with a 23% (OR: 1.33, 1.134–1.338) and 16% (OR: 1.232, 1.134–1.338) increase in mortality at 90 days and 1 year post op respectively. Conclusions. In this exact matched cohort study, risk of early revision and revision for PPFx was dramatically reduced at all time points with the use of cemented stem fixation for elective THA and FNF. However, the increased risk of 90d and 1 year mortality following cemented stem fixation in the elective population warrants further investigation


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1565 - 1571
1 Dec 2018
Kristensen TB Dybvik E Furnes O Engesæter LB Gjertsen J

Aims. The aim of this large registry-based study was to compare mid-term survival rates of cemented femoral stems of different designs used in hemiarthroplasty for a fracture of the femoral neck. Patients and Methods. From the Norwegian Hip Fracture Register (NHFR), 20 532 primary cemented bipolar hemiarthroplasties, which were undertaken in patients aged > 70 years with a femoral neck fracture between 2005 and 2016, were included. Polished tapered stems (n = 12 065) (Exeter and CPT), straight stems (n = 5545) (Charnley, Charnley Modular, and Spectron EF), and anatomical stems (n = 2922) (Lubinus SP2) were included. The survival of the implant with any reoperation as the endpoint was calculated using the Kaplan–Meier method and hazard ratios (HRs), and the different indications for reoperation were calculated using Cox regression analysis. Results. The one-year survival was 96.0% (95% confidence interval (CI) 95.6 to 96.4) for the Exeter stem, 97.0% (95% CI 96.4 to 97.6) for the Lubinus SP2 stem, 97.6% (95% CI 97.0 to 98.2) for the Charnley stem, 98.1% (95% CI 97.3 to 98.9) for the Spectron EF stem, and 96.4% (95% CI 95.6 to 97.2) for the Charnley Modular stem, respectively. The hazard ratio for reoperation after one year was lower for Lubinus SP2 (HR 0.77, 95% CI 0.60 to 0.97), Charnley (HR 0.64, 95% CI 0.48 to 0.86), and Spectron EF stems (HR 0.44, 95% CI 0.29 to 0.67) compared with the Exeter stem. Reoperation for periprosthetic fracture occurred almost exclusively after the use of polished tapered stems. Conclusion. We were able to confirm that implant survival after cemented hemiarthroplasty for a hip fracture is high. Differences in rates of reoperation seem to favour anatomical and straight stems compared with polished tapered stems, which had a higher risk of periprosthetic fracture


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1611 - 1619
1 Dec 2016
Wilson MJ Hook S Whitehouse SL Timperley AJ Gie GA

Aims. Femoral impaction bone grafting was first developed in 1987 using morselised cancellous bone graft impacted into the femoral canal in combination with a cemented, tapered, polished stem. We describe the evolution of this technique and instrumentation since that time. . Patients and Methods. Between 1987 and 2005, 705 revision total hip arthroplasties (56 bilateral) were performed with femoral impaction grafting using a cemented femoral stem. All surviving patients were prospectively followed for a mean of 14.7 years (9.8 to 28.3) with no loss to follow-up. By the time of the final review, 404 patients had died. Results. There were 76 further revisions (10.8%) involving the stem; seven for aseptic loosening, 23 for periprosthetic fracture, 24 for infection, one for malposition, one for fracture of the stem and 19 cement-in-cement exchanges of the stem during acetabular revision. The 20-year survival rate for the entire series was 98.8% (95% confidence interval (CI) 97.8 to 99.8) with aseptic loosening as the endpoint, and 87.7% (95% CI 82.8 to 92.6) for revision for any reason. Survival improved with the evolution of the technique, although this was not statistically significant due to the overall low rate of further revision. Conclusion. This is the largest series of revision total hip arthroplasties with femoral impaction grafting, and the results support the continued use of this technique. Cite this article: Bone Joint J 2016;98-B:1611–19


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 315 - 320
1 Mar 2006
Field RE Singh PJ Latif AMH Cronin MD Matthews DJ

We describe the results at five years of a prospective study of a new tri-tapered polished, cannulated, cemented femoral stem implanted in 51 patients (54 hips) with osteoarthritis. The mean age and body mass index of the patients was 74 years and 27.9, respectively. Using the anterolateral approach, half of the stems were implanted by a consultant orthopaedic surgeon and half by six different registrars. There were three withdrawals from the study because of psychiatric illness, a deep infection and a recurrent dislocation. Five deaths occurred prior to five-year follow-up and one patient withdrew from clinical review. In the remaining 51 hips the mean pre-operative Oxford hip score was 47 points which decreased to 19 points at five years (45 hips). Of the stems 49 (98%) were implanted within 1° of neutral in the femoral canal. The mean migration of the stem at five years was 1.9 mm and the survivorship for aseptic loosening was 100%. There was no significant difference in outcome between the consultant and registrar groups. At five years, the results were comparable with those of other polished, tapered, cemented stems. Long-term surveillance continues


Bone & Joint Open
Vol. 4, Issue 3 | Pages 198 - 204
16 Mar 2023
Ramsay N Close JCT Harris IA Harvey LA

Aims

Cementing in arthroplasty for hip fracture is associated with improved postoperative function, but may have an increased risk of early mortality compared to uncemented fixation. Quantifying this mortality risk is important in providing safe patient care. This study investigated the association between cement use in arthroplasty and mortality at 30 days and one year in patients aged 50 years and over with hip fracture.

Methods

This retrospective cohort study used linked data from the Australian Hip Fracture Registry and the National Death Index. Descriptive analysis and Kaplan-Meier survival curves tested the unadjusted association of mortality between cemented and uncemented procedures. Multilevel logistic regression, adjusted for covariates, tested the association between cement use and 30-day mortality following arthroplasty. Given the known institutional variation in preference for cemented fixation, an instrumental variable analysis was also performed to minimize the effect of unknown confounders. Adjusted Cox modelling analyzed the association between cement use and mortality at 30 days and one year following surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 435 - 441
1 May 2024
Angelomenos V Mohaddes M Kärrholm J Malchau H Shareghi B Itayem R

Aims

Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures.

Methods

Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 540 - 547
1 Jun 2024
Nandra RS Elnahal WA Mayne A Brash L McBryde CW Treacy RBC

Aims

The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon’s consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years.

Methods

The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 680 - 685
1 Jul 2001
Bowditch M Villar R

Early failures have seen titanium fall from favour as a material for cemented femoral stems. Between 1989 and 1994, we performed a prospective review of a consecutive series of 122 cemented total hip replacements using the Ultima straight textured titanium stem, and report the five- to ten-year clinical and radiological outcomes. There were no revisions for loosening of the femoral stem. Revision surgery was undertaken for other reasons such as dislocation, infection and loosening of the cup in 7.3%. Of those patients without revision all but two were satisfied with their hip, with 74% graded good or excellent using a modified Harris hip score. Radiological assessment revealed probable loosening in two. Although slight vertical subsidence was found in one-third of patients it had not progressed to loosening. It is not clear whether this represents debonding. Non-progressive radiolucent lines (1 to 2 mm) were present in zone 1 at the cement-prosthesis interface in 14.7%. Calcar resorption and hypertrophy around the distal stem were not often seen. With 97% survival at a mean of 7.5 years, the medium-term results of this specific cemented titanium stem are reassuring so far, but we are concerned about debonding and future failure


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 212 - 220
1 Feb 2022
Fishley WG Selvaratnam V Whitehouse SL Kassam AM Petheram TG

Aims

Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique.

Methods

We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 1 - 1
1 Oct 2020
Clohisy J Haddad FS
Full Access

The unparalleled events of the year 2020 continue to evolve and challenge the worldwide community on a daily basis. The COVID-19 pandemic has had a major impact on all aspects of our lives, and has caused major morbidity and mortality around the globe. The impact of COVID-19 on the practice of orthopedic surgery has been substantial with practice shutdowns, elective surgery restrictions, heightened utilization of telemedicine platforms and implementation of precautionary measures for in-person clinic visits. During this transition period the scholarly and educational pursuits of academic surgeons have been de-emphasized as the more immediate demands of clinical practice survivorship have been the priority. This unavoidable focus on clinical practice has heightened the importance of orthopedic subspecialty societies in maintaining an appropriate level of attention on research and educational activities. Under the outstanding presidential leadership of Robert Barrack, MD, The Hip Society adapted to the profound challenges of 2020, and maintained strong leadership in the realms of education and research. The recent 2020 summer meeting of the Hip Society was a testimonial to the resilience and dedication of the Society members to ongoing innovation in research and education. Due to travel and social distancing restrictions the 2020 summer meeting was transitioned from an in-person to a virtual meeting format. Dr Barrack and Program Chair Dr John Clohisy assisted with oversight of the meeting, while Olga Foley and Cynthia Garcia ensured the success of the meeting with remarkable planning and organization. These collaborative efforts resulted in an organized, well-attended, high level scientific meeting with engaging discussion and a remarkable virtual conference environment. The Bone & Joint Journal is very pleased to partner with The Hip Society to publish the proceedings of this very unique virtual meeting. The Hip Society is based in the United States and membership is granted to select individuals for leadership accomplishments in education and research related to hip disease. The Society is focused on the mission of advancing the knowledge and treatment of hip disorders to improve the lives of patients. The vision of the Hip Society is to lead in the discovery and dissemination of knowledge related to disorders of the hip. The annual closed meeting is one of the most important events of the society as this gathering highlights timely, controversial and novel research contributions from the membership. The top research papers from The Hip Society meeting will be published and made available to the wider orthopedic community in The Bone & Joint Journal. This partnership with The Bone & Joint Journal enhances the mission and vision of The Hip Society by international dissemination of the meeting proceedings. Given the far-reaching circulation of The Bone & Joint Journal the highest quality work is available to an expanding body of surgeons, associated healthcare providers and patients. Ultimately, this facilitates the overarching Hip Society goal of improving the lives of our patients. The 2020 virtual Hip Society meeting was characterized by outstanding member attendance, high quality paper presentations and robust discussion sessions. The meeting was held over two days and encompassed 58 open paper presentations divided into ten sessions with moderated discussions after each session. All papers will be presented in this issue in abstract form, while selected full papers passing our rigorous peer review process will be available online and in The Bone & Joint Journal in a dedicated supplement in 2021. The first session of the meeting focused on issues related to complex primary THA and osteonecrosis of the femoral head. Dr Gross presented on the conversion of hip fusion to THA in 28 patents at a mean 7 years. He reported a high clinical success rate, yet complications of heterotopic ossification and neurologic injury were relatively common. Consideration of heterotopic ossification prophylaxis and the selective use of a constrained liner were recommended. Dr Pagnano summarized the use of various contemporary porous acetabular components in 38 hips in the setting of prior pelvic radiation. The mean follow-up was 5 years and 10 year survivorship was 100% with all implants radiographically fixed. Dr Bolognesi's study demonstrated that THA in solid organ transplant patients is associated with higher risk for facility placement, transfusions and readmissions. This patient population also has increased mortality risk (4.3% risk at 1 year) especially lung transplant patients. The second group of papers focused on femoral head osteonecrosis. Dr Iorio presented single center data demonstrating that CT scan was a useful adjunct for diagnosis in the staging work-up for cancer, yet was not useful for ARCO staging and treatment decision-making. On the basic science side, Dr Goodman utilized a rabbit model of steroid-induced femoral head osteonecrosis to determine that immunomodulation with IL-4 has the potential to improve bone healing after core decompression. The session was concluded by Dr Nelson's study of ceramic-on-ceramic THA in 108 osteonecrosis patients. The median 12 year results were outstanding with marked increases in PROs, maintenance of high activity levels, and a 3.7% revision rate. In the second session attention was directed to THA instability and spinopelvic mobility. Dr Sierra presented a machine learning algorithm for THA dislocation risk. Two modifiable variables (anterior/lateral approach, elevated liner) were most influential in minimizing dislocation risk. Dr Taunton's study demonstrated a deep learning artificial intelligence model derived from postoperative radiographs to predict THA dislocation risk. High sensitivity and negative predictive value suggest that this model may be helpful in assessing postoperative dislocation risk. In reviewing a large single-center, multiple surgeon cohort of 2,831 DAA procedures, Dr Moskal noted a very low dislocation rate (0.45%) at minimum 2 years. Importantly, spinopelvic pathology or prior spinal instrumentation was not associated with an increased dislocation risk (0.30%). Dr Huo and colleagues analyzed pelvic tilt during functional gait in patients with acetabular dysplasia. They detected variable pelvic tilt on different surfaces with the data suggesting that patients with more anterior pelvic tilt while standing tend to have greater compensatory posterior pelvic tilt during gait. Dr Lamontagne reported on the sagittal and axial spinomobility in patients with hip OA, and highlighted reductions in pelvic tilt, pelvic-femoral-angle, lumbar lordosis and seated maximal trunk rotation when compared to controls. Dr Dennis showed that differences in spinopelvic mobility may explain the variable accuracy of acetabular version measurements on the cross-table lateral radiographs. Dr Gwo-Chin presented on a comprehensive functional analysis of 1,592 patients undergoing THA and observed that spinopelvic abnormalities are not infrequent (14%) in THA patients. Consistent with these findings Dr Murphy and collaborators identified a low prevalence of previous spinal instrumentation (1.5%), yet a high prevalence of spine stiffness (27.6%) in 149 patients undergoing THA. Session three highlighted various aspects of treating hip disease in young patients. Dr Peters investigated the need for subsequent hip arthroscopy in 272 patients treated with an isolated PAO. Only 4.8% of these patients required subsequent arthroscopy calling into question the routine use of combined arthroscopy and PAO. Three papers addressed questions related to THA in young patients. Dr Berend's study of 2532 hips demonstrated that high activity level was not associated with an increased risk of midterm aseptic or all cause failure. Dr Nunley presented on 43 young patients with an average age of 52 years treated with a cementless stem and modular dual mobility articulation. Stress shielding was minimal and no concerning metal ion release detected. Dr Garvin summarized minimum 15 year data of THA with highly cross-linked polyethylene in patient less than 50 years. These hips performed exceptionally well with no mechanical loosening or radiographic osteolysis. Dr Engh examined 10 year results of the Birmingham Hip Resurfacing implant and reported a 92.9 % overall survivorship, with males less than 55 years achieving a 98.3% survivorship. The session was concluded by long-term data on the Conserve Plus hip resurfacing arthroplasty. Dr Amstutz presented an impressive dataset depicting an 83.1% 20 year survivorship for this early resurfacing cohort. Direct anterior approach total hip arthroplasty was the focus of session four. Dr Meneghini reported on the anesthesia and surgical times of direct anterior and posterior approaches from a large healthcare system database. These data suggested longer OR and surgical times for the DAA both in the inpatient and ASC environments. Dr Clohisy introduced the technique and early outcomes of lateral decubitus position DAA. In a learning curve experience of 257 hips. 96% of acetabular components were in the Lewinneck safe zone, the aseptic revision rate was 0.9% and there were no dislocations. Dr Beaule analyzed femoral stem cement mantle with the DAA and posterior approaches by comparing two matched cohorts. Stem alignment and cement mantle quality were equivalent with both approaches. Similarly, Dr Emerson demonstrated technical feasibility and fewer cemented femoral stem failures when compared to cementless stems in a series of 360 DAAs THAs. The final paper of the session presented by Dr Hamilton examined the impact of surgical approach on dislocation after isolated head and liner exchange. Neither the posterior nor the anterior approach was superior in reducing the dislocation rate for these high dislocation risk procedures. The fifth session explored contemporary topics related to anesthesia and pain management. Dr Byrd opened the session with a comparative study evaluating general versus spinal anesthesia for hip arthroscopy. This preliminary study was provoked by the desire to minimize aerosolized exposure early in the COVID-19 pandemic by transitioning to spinal anesthesia. Both anesthetic methods were effective. Dr Austin presented a randomized, double-blind controlled trial comparing spinal anesthetic with mepivacaine, hyperbaric bupivacaine and isobaric bupivacaine. Mepivacaine patients ambulated earlier and were more likely to be discharged the same day. Dr Mont provided a very timely study on the effects of “cannabis use disorder” and THA outcomes. This administrative database study of 44,154 patients revealed this disorder to be associated with longer hospital stays, increased complications rates and higher costs. Dr Bedair investigated whether a highly porous acetabular component submerged in an analgesic solution could enhance perioperative pain management. Interestingly, this novel strategy was associated with a reduction of postoperative pain scores and opioid consumption in 100 experimental patients compared to 100 controls. The concluding paper of the session by Dr Della Valle examined whether decreased discharge opioids led to increased postoperative opioid refills. A large single-center study of 19,428 patients detected a slight increase (5%) in opioid refills but a reduction in total refill morphine milligram equivalents. The final, sixth session of day one considered various challenging aspects of revision hip arthroplasty. Dr Nam started the session with review of preliminary results from a randomized control trial comparing closed incision negative-pressure therapy with a silver-impregnated dressing for wound management in 113 hips undergoing revision arthroplasty. Unlike previous reports, the negative pressure therapy was associated with a higher reoperation rate for wound-related complications. Dr Bostrom highlighted the potential clinical impact of basic biological interventions by establishing the presence of Neutrophil Extracellular Traps (NETS) in fibrotic tissue from human aseptic loosening specimens and in a murine model of unstable tibial implantation. NET inhibition in the murine model prevented the expected tibial implant osseointegration failure. Dr Lombardi presented early 3.3 year clinical results of a highly porous Ti6al4v acetabular component in complex primary and revision arthroplasty. Survivorship for aseptic loosening was 96.6 % and 95.3% for the primary and revision cases, respectively. Dr Schwarzkopf and colleagues explored the impact of time to revision arthroplasty on clinical outcomes. Analysis of 188 revision cases revealed early revisions (less than 2 years from primary) were associated with worse outcomes, longer hospitalizations and higher reoperation rates. Mid-term results for modular dual mobility implants in revision arthroplasty were reviewed by Dr Lachiewicz who reported on 126 hips at a mean 5.5 years. 11% of hips dislocated and the 6 year survival was 91%. An outer head diameter of 48mm or greater was associated with a lower risk of dislocation. Dr Berry concluded the session by discussing the outcomes of treating the challenging problem of interprosthetic femur fractures. A single-center study of 77 cases treated over 32 years demonstrated a 79% success rate free of reoperation at 2 years with 95% of patients being ambulatory. The second day commenced with the seventh session evaluating recent strategies to improve short-term THA outcomes. Dr Bozic and colleagues investigated the association of quality measure public reporting with hip/knee replacement outcomes. Annual trend data from 2010–2011 and 2016–2017 indicate that hospital-level complication and readmission rates decease after the start of public reporting, yet it is difficult to prove a direct effect. Dr Slover reviewed his institutions experience with the Comprehensive Care for Joint Replacement (CJR) model and emphasized that lower CJR target prices make it increasingly difficult for programs to meet target price thresholds. Cost saving strategies including same day discharge and reduction of home health services may result in smaller losses of positive margins. Dr Barsoum reported on the influence of patient and procedure-related risk factors of length of stay after THA. Patient-related risk factors provided substantial predictive value yet procedure-related risk factors (hospital site and surgical approach) remain the main drivers of predicting length of stay. Dr Hozack reviewed an impressive, single surgeon cohort of 3,977 DAA THAs and analyzed adverse events and 90 day perioperative outcomes. Simultaneous bilateral DAA THA was comparable with unilateral or staged bilateral procedures in regards to complications, readmission rate and home discharge rate but with an increased risk of transfusion. To examine the risk of complications with outpatient joint arthroplasty, Dr Della Valle performed a single-surgeon matched cohort analysis comparing outpatient and inpatient hip and knee arthroplasties. Outpatient procedures were not associated with an increased risk of any postoperative complications and actually experienced fewer emergency department visits. The eighth session covered various contemporary challenges in hip arthroplasty care. Dr Griffin began the session with an analysis of the timing of complications associated with two-stage exchange procedures for periprosthetic joint infection (PJI). Of the 189 hips included, 41.6% had a complication and the mortality was 14.1% at 2.5 years, highlighting the morbidity of this treatment method. Dr Fehring provided data assessing the fate of two-stage reimplantation after failed debridement, antibiotics and implant retention (DAIR) for a prosthetic hip infection. This analysis of 114 hips yielded concerning results demonstrating a 42.9% treatment failure of patients treated with a previous DAIR compared to a 12.3% failure rate in patients treated with an initial 2-stage procedure. Dr Jacobs reviewed the analysis of 106 femoral heads with severe corrosion and identified a chemically dominated etching process termed “column damage” to be a detrimental damage mode within CoCr femoral heads that is directly linked to banding within its microstructure. These data indicate that implant alloy microstructure must be optimized to minimize the release of fretting-corrosion products. Simon Mears presented retrospective data from 184 THAs with a dual modular femoral stem. A subgroup of hips with a modular, cobalt chromium femoral neck had a pseudotumor visualized in 15% with only 55% of these having elevated CoCr levels. These findings may support the use of routine follow-up MARS MRI for modular CoCr femoral neck prostheses. The final two studies explored timely issues related to viral illness and hip surgery. Dr Browne analyzed three large administrative databases to elucidate whether patients are at increased risk for viral illnesses following total joint replacement. The incidence of postoperative influenza after total joint replacement was not increased compared to patients not undergoing total joint replacement surgery suggesting that arthroplasty procedures may not heighten the risk of viral illness. In the final paper of the session Dr Haddad presented important data regarding perioperative complications in coronavirus positive patients undergoing surgical treatment of femoral neck fractures. In this multicenter cohort study from the United Kingdom 82 coronavirus positive patients were shown to have longer hospital stays, more critical care unit admissions, higher risk of perioperative complications and an increased mortality compared to 340 coronavirus negative patients. The eighth session had two papers on alternative femoral stem designs and three presentations more focused on femoral fracture treatments. Dr Mihalko focused on the European and US experiences with the Metha femoral neck retaining stem. The US experience mirrored the encouraging results from Europe with a 94% all cause femoral survivorship and a 99.1% femoral aseptic loosening survivorship at 5 years. Dr Kraay summarized dual energy x-ray absorptiometry (DEXA) evaluation of 16 low modulus composite femoral components at long-term follow-up of a mean 22 years. The bone mineral density associated with the implant increased in Gruen zones 2–6 and showed limited decreases in zones 1 and 7. These data support the concept that a low modulus femoral stem may more effectively load the proximal femur. Dr Springer provided data from the American Joint Replacement Registry (AJRR) and by evaluating outcomes of exact matched cohorts of 17,138 patients treated with cementless or cemented femoral implants for femoral neck fractures. Cemented implants were associated with marked reduction in early revision and periprosthetic fractures. However, cemented fixation was associated with an increased mortality at 90 days and 1 year. Additional data from the AJRR was presented by Dr Huddleston who investigated the risk factors for revision surgery after arthroplasty in a cohort of 75,333 femoral neck fractures. THA when compared to hemiarthroplasty was associated with higher early and overall revision rates. Cementless femoral fixation and increased age were also associated with higher rates of any revision. Both of these studies from the AJRR suggest that further consideration should be given to femoral fixation preferences in the femoral neck fracture population. Dr Vail summarized his institution's experience with an interdisciplinary hip fracture protocol for patients undergoing arthroplasty for acute femoral neck fractures. His study compared 157 cases prior to protocol implementation with 114 patients treated after the protocol was established. The impact of the interdisciplinary protocol was impressive as evidenced by a reduced time to operative treatment, length of stay, complication rate and one-year mortality. All being achieved without an increase in readmissions or facility discharges. The final session of the meeting addressed innovations in perioperative care of THA patients. Dr Barrack started the session with an interesting study examining the feasibility and patient preferences regarding telemedicine. A cross-sectional telephone survey of 163 arthroplasty patients indicated that 88% of patients use the internet and 94% own a device capable of videoconferencing. Nevertheless, only 18% of patients preferred a video visit over an in-person clinic visit due to concerns of inferior care. Dr Barnes quantified preoperative optimization work in 100 arthroplasty patients by using EMR activity logs and determined the surgical team spends an average 75 minutes per case on preoperative work activities. Dr Duwelius reported the early outcomes of primary THA with a smartphone-based exercise and educational platform compared to standard of care controls. A randomized control trial design with 365 patients demonstrated similar outcomes and non-inferiority of the smartphone platform relative to complications, readmissions, emergency room/urgent care visits. The association of controlled substance use with THA outcomes was assessed by Dr Higuera Rueda. A quantitative assessment using the NarxCare score identified 300 and above as a score associated with adverse outcomes after THA. Dr Macaulay reviewed data from a large retrospective study of 1,825 THAs indicating that discontinuation of intermittent pneumatic compression devices does not increase the risk of venous thromboembolism in standard risk patients being treated with 81mg ASA BID as prophylaxis. Dr Antoniou presented the final paper of the meeting investigating potential changes in patient health status as an indication for surgery over time. Data from this large systematic review of the literature found patients undergoing THA at similar health status to the past with no influence form patient age, gender, year of enrollment or geographic region. As summarized above, the 2020 virtual Hip Society Summer Meeting was rich in scientific content, productive discussion and a collaborative spirit. This collective body of work will result in impactful scientific contributions and will serve as a foundation for future innovation and advancements in the treatment of hip disease


Bone & Joint Open
Vol. 2, Issue 7 | Pages 466 - 475
8 Jul 2021
Jain S Lamb J Townsend O Scott CEH Kendrick B Middleton R Jones SA Board T West R Pandit H

Aims

This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty.

Methods

Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type.


Bone & Joint Open
Vol. 2, Issue 6 | Pages 443 - 456
28 Jun 2021
Thompson JW Corbett J Bye D Jones A Tissingh EK Nolan J

Aims

The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems.

Methods

A systematic literature search was performed adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. In parallel, we performed a retrospective single centre study of Exeter V40 femoral stem prosthetic fractures between April 2003 and June 2020.