Advertisement for orthosearch.org.uk
Results 1 - 20 of 74
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 28 - 28
1 Jul 2020
Burkhart T Baha P Getgood A Degen R
Full Access

While hip arthroscopy utilization continues to increase, capsular management remains a controversial topic. Therefore the purpose of this research was to investigate the biomechanical effect of capsulotomy and capsular repair techniques on hip joint kinematics in varying combinations of sagittal and coronal joint positions. Eight fresh-frozen hemipelvises (4 left, 6 male) were dissected of all overlying soft tissue, with the exception of the hip joint capsule. The femur was potted and attached to a load cell, while the pelvis was secured to a custom-designed fixture allowing static alteration of the flexion/extension arc. Optotrak markers were rigidly attached to the femur and pelvis to track motion of the femoral head with respect to the acetabulum. Following specimen preparation, seven conditions were tested: i) intact, ii) after portal placement (anterolateral and mid-anterior), iii) interportal capsulotomy (IPC) [35 mm in length], iv) IPC repair, v)T-capsulotomy [15 mm longitudinal incision], vi) partial T-repair (vertical limb), vii) full T-repair. All conditions were tested in 15° of extension (−15˚), 0°, 30°, 60° and 90° of flexion. Additionally, all flexion angles were tested in neutral, as well as maximum abduction and adduction, resulting in 15 testing positions. 3Nm internal and external rotation moments were manually applied to the femur via the load cell at each position. Rotational range of motion and joint kinematics were recorded. IPC and T-capsulotomies increased rotational ROM and mediolateral (ML) joint translation in several different joint configurations, most notably from 0–30˚ in neutral abduction/adduction. Complete capsular repair restored near native joint kinematics, with no significant differences between any complete capsular repair groups and the intact state, regardless of joint position. An unrepaired IPC resulted in increased rotational ROM, but no other adverse translational kinematics. However, an unrepaired or partially repaired T-capsulotomy resulted in increased rotational ROM and ML translation. The results of this study show that complete capsular repair following interportal or T-capsulotomy adequately restores rotational ROM and joint translation to near intact levels. Where feasible, complete capsular closure should be performed, especially following T-capsulotomy. However, further clinical evaluation is required to determine if adverse kinematics of an unrepaired capsule are associated with patient reported outcomes


Full Access

To evaluate the impact of routine capsular repair on patient-reported outcomes, survivorship and achievability of clinically important improvement, minimum 5-years post-surgery. Our prospective institutional registry was reviewed for cases undergoing primary HA for FAI, and stratified into two groups depending on whether the capsule was repaired or not. Routine repair was introduced in late 2013. The No Repair group consisted of patients undergoing HA between Jan 2010-June 2013 while the Repair group consisted of patients undergoing HA between Jan 2015-Sept 2018. Exclusion criteria consisted of >50 years, Tonnis>1, dysplasia(LCEA<25), concomitant hip pathologies. PROMs consisted of mHHS, SF36 and UCLA. Metrics of clinically important improvement was evaluated using MCID and SCB. Rates of repeat HA or THA conversion were recorded. 985 cases were included (359 No Repair; 626 Repair), 86% male, average age 27.4±6.7years. Significant improvement in all PROMs at minimum 5-years was observed for both groups (p<0.001 for all; large effect sizes for mHHS and SF36, medium effect sizes for UCLA). At 5-years post-op there was no significant difference between groups for mHHS(p=0.078) or UCLA(0.794). SF36 was significantly poorer for those cases undergoing routine repair(p<0.001) however effect size was small (0.20). Thresholds of MCID and SCB were calculated as 69% and 86% for mHHS, 64% and 77% for UCLA, 43% and 60% for SF36. Both groups achieved MCID and SCB at similar rates for mHHS and UCLA. A significantly lower proportion of cases in the repair groups achieved MCID for SF36 (53.6% vs 63.5%, p=0.034) and SCB for SF36 (37.3% vs 52.8%, p<0.001). No significant difference between groups for THA conversion (0.6% No Repair vs 0.5% Repair) or repeat HA (9.7% No Repair vs 8.1% Repair). Routinely repairing the capsule following HA for FAI demonstrates no clinical benefit over not repairing the capsule 5 years post-surgery


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 339 - 339
1 Jul 2008
Trehan R Shetty A Naidu V
Full Access

We wish to report the use of a modified ‘Y-V’ medial capsular repair in association with Chevron osteotomy fixed rigidly with Barouk screw for Hallux valgus in 45 patients (52 feet) aged 16 to 70 years (mean 47 years) between July 2004 and September 2005. All patients were retrospectively reviewed by questionnaire, physical examination (American Orthopaedic Foot and Ankle Society score) and comparison of preoperative and post operative x rays. Using this technique none of the patients required additional immobilization apart from wool and crepe bandage following surgery. All osteotomies healed without any problem. There was no deep infection reported in this series. There were two superficial infection treated with oral antibiotics. There is no recurrence of deformity so far. At an average of six months follow up American Orthopaedic Foot and Ankle Society score improved significantly. Intermetatarsal (IM) angle and the hallux valgus (HV) angles were also improved considerably. Stabilization of Chevron osteotomy with k wires, plaster of Paris is well known but these techniques have problems of infection and stiffness. Osteotomies carried out without any stabilization has high recurrence rate. Fixation of osteotomy with Barouk screw is a very simple procedure, which not only gives stability and compression to osteotomy but also reduces need for any plaster immobilization thus speed up rehabilitation. This also gives extra confidence to surgeon to allow patient for early weight bearing and mobilization. We also recommend the use of modified ‘Y-V’ medial capsular repair to correct the hallux valgus angle and reduce the meta tarso-phalangeal joint leading to reduction in possibility of recurrence


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 500 - 501
1 Aug 2008
Naidu V Trehan R Shetty A Lakkireddi P Kumar G
Full Access

Hallux valgus is a common condition and surgical correction has remained a challenge. Scarf osteotomy with Akin procedure is well accepted method. Akin procedure gives spurious correction of the distal alignment of big toe. This study was performed to see alternative way to get best correction without additional phalangeal procedure. Senior author used innovative Y-V medial capsulorraphy with standard Scarf osteotomy. This technique allows reduction of MP joint along with correction of pronation deformity and reduction of sesamoids. We report the use of a modified Y-V medial capsular repair in association with Scarf osteotomy for Hallux valgux in 45 patients (55 feet) aged 18 to 76 years (mean 43 years) between October 2004 and December 2005. Clinical follow up was both subjective and objective. Patients were asked about rating of their satisfaction and objective assessment was done in form of AOFAS score. Using this technique none of the patients required an additional proximal phalangeal osteotomy with metatarsal osteotomy. At six months follow up American Orthopaedic Foot and Ankle Society score improved from 46 to 87. Intermetatarsal (IM) angle and the hallux valgus (HV) angle improved from 16° to 9° and from 31° to 16° respectively (p< 0.05). At final follow up 8 patients were very satisfied, 12 were satisfied while 5 were not satisfied. Of the 55 procedures 51 did not develop any complications. Two had superficial infections, treated successfully with oral antibiotics only. Two patients had recurrence, one was treated with Akin and second patient declined surgery as she was not bothered with it. We recommend the use of this modified ‘Y-V’ medial capsular repair to reduce the need for an additional procedure to augment the correction achieved during Scarf osteotomy for hallux valgus. This reduces hallux valgus angle and maintains it


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 590 - 590
1 Dec 2013
Woodard E Mihalko W Crockarell J Williams J
Full Access

Introduction:. Repair of the arthrotomy is a performed at the end of every total knee arthroplasty (TKA). After the arthrotomy is performed, most surgeons attempt to close the arthrotomy with the medial and lateral edges anatomically approximated. If no landmarks are made prior to performing the arthrotomy however, there is a risk that anatomic approximation may not be obtained. This study looked into the biomechanical changes in stiffness of the knee before and after a medial parapatellar approach repaired with an anatomic, and shifted capsular repair with the medial side of the arthrotomy shifted up or down when repaired to determine if capsular closure may have an effect on the stiffness of the joint. Methods:. Fourteen cadaveric TKA specimens were retrieved through the Medical Education and Research Institute (Memphis TN). For each specimen tested, the skin and muscle tissue was removed, and the femur and tibia were cut transversely 180 mm from the joint center. Specimens were fixed in extension in a custom knee testing platform (Little Rock AR) and subjected to a 10 Nm varus and valgus torque and a 1.5 Nm internal and external rotational torque. The angle at which these moments occurred was recorded, and each test was repeated for 0, 30, 60, and 90 degrees of flexion. After tests were performed on retrieved TKA specimens, a fellowship trained orthopedic surgeon vented the knee capsule by making an incision with a number 10 scalpel blade in a horizontal nature to provide a landmark for anatomic reapproximation. Tests were repeated as before, after which the surgeon performed a standard arthrotomy and repaired it using #0 suture and a neutral alignment. Sutures were cut and the repair was repeated using upward 5 mm shift and downward 5 mm shift of the medial side of the arthrotomy during the repair. All tests were repeated after each repair technique. Any increase or decrease in laxity after capsule repair was referenced to the TKA laxity tested prior to an arthrotomy being performed. Results:. Simply venting the capsule did increase laxity of the TKA in midflexion to varus torque by 3 degrees under the same torque. Otherwise, when the medial limb of the arthrotomy was shifted up during closure by 5 mm, the knee joint tended to be stiffer in flexion compared to the neutral repair measurements under varus torque, while it was closer to the measurements of the neutral or anatomic closure when the medial limb was shifted down during closure. These changes seemed to be seen in flexion more than full extension. Discussion and Conclusion:. Small changes were measured in the stiffness of the joint after venting the capsule and under different degrees of non-anatomic closure. The results stress the fact that the capsule can be measurably tightened during arthrotomy repair and may impact post-operative rehabilitation or range of motion


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 321 - 328
1 Feb 2021
Vandeputte F Vanbiervliet J Sarac C Driesen R Corten K

Aims

Optimal exposure through the direct anterior approach (DAA) for total hip arthroplasty (THA) conducted on a regular operating theatre table is achieved with a standardized capsular releasing sequence in which the anterior capsule can be preserved or resected. We hypothesized that clinical outcomes and implant positioning would not be different in case a capsular sparing (CS) technique would be compared to capsular resection (CR).

Methods

In this prospective trial, 219 hips in 190 patients were randomized to either the CS (n = 104) or CR (n = 115) cohort. In the CS cohort, a medial based anterior flap was created and sutured back in place at the end of the procedure. The anterior capsule was resected in the CR cohort. Primary outcome was defined as the difference in patient-reported outcome measures (PROMs) after one year. PROMs (Harris Hip Score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), and Short Form 36 Item Health Survey (SF-36)) were collected preoperatively and one year postoperatively. Radiological parameters were analyzed to assess implant positioning and implant ingrowth. Adverse events were monitored.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 28 - 28
1 Jul 2020
Corten K Vanbiervliet J Vandeputte F
Full Access

INTRODUCTION

The capsular releasing sequence is crucial to safely conduct the Direct Anterior Approach for THA on a regular OR table. The release of the anterior capsule is the first step of the releasing sequence and allows for optimal exposure. This can be done by either resecting a part of the anterior capsule or by preserving it. Our zero hypothesis was that clinical outcomes would not be different between both techniques.

MATERIALS & METHODS

190 Patients operated between November 2017 and May 2018, met the inclusion criteria and were randomly allocated in a double blinded study to either the capsular resection (CR)(N=99) or capsular preservation (CP)(N=91) cohort. The same cementless implant was used in all cases. Patient-reported outcome measures (PROMS) were collected pre- and post-operatively at 6 weeks, 3 months and 1 year. Adverse events were recorded. Outcomes were compared with the Mann-Withney U test and a significance level of p<0,05.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 110 - 111
1 Mar 2008
Chivas D Smith K Tanzer M
Full Access

This is the first study to determine if closure of the posterior capsule during revision total hip arthroplasty (THA) results in a reduction in the historically high dislocation rate. Seventy-nine consecutive patients undergoing revision THA with a posterolateral approach and closure of the posterior hip capsule were retrospectively reviewed. At a mean follow-up of fifty-seven months (range twenty-four to one hundred and twenty months), there were only two dislocations (2.5%). The historically high dislocation rates with the posterolateral approach in revision THA, can be significantly decreased with posterior capsular closure from approximately 15% to 2.5%.

To determine if closure of the posterior capsule during revision total hip arthroplasty results in a reduction in the historically high dislocation rate.

The dislocation rate after revision THA with a posterior approach can be minimized by repairing the posterior capsule and rotators.

The historically high dislocation rates with the pos-terolateral approach in revision THA, can be significantly decreased with posterior capsular closure from approximately 15% to 2.5%.

A retrospective study was carried out to review seventy-nine consecutive revision THAs. In all cases, the surgery was done by a single surgeon using the posterolateral approach. In every case, the posterior capsule was meticulously repaired at the end of the procedure. All patients had a minimum two- year follow-up and no patients were lost to follow up.

At a mean follow-up of fifty-seven months (range twenty-four to one hundred and twenty months), there were only two dislocations (2.5%). Both dislocations occurred early postoperatively were anterior. One occurred in a high risk case- a proximal femoral replacement with a trochanteric osteotomy, high hip center and skirted head. The other was due to a technical error, with the cup being excessively anteverted. There were no late dislocations or subluxations.

The dislocation rate after revision THA with a posterior approach can be minimized by balancing soft tissues, correct implant alignment and repairing the posterior capsule and rotators.


Bone & Joint 360
Vol. 11, Issue 1 | Pages 32 - 35
1 Feb 2022


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 577 - 577
1 Oct 2010
Volpin G Daniel M Kaushanski A Lichtenstein L Shachar R Shtarker H
Full Access

Introduction: Various surgical methods have been described to manage the problem of recurrent anterior dislocation of the shoulder. Older procedures Putti-Platt’s, Magnuson-Stack’s or Bristow;’s and Boytchev’s repair are not used today due to a high percentage of failure of 7%–17% incidence of recurrence associated with limited ROM. However, in the last decade the goal of treatment has changed. It is directed now towards restoration of normal function with full ROM of the affected shoulder, based mainly on arthroscopic stabilization or on “open” Neer’s capsular shift procedures combined with Bankart’s repair. However, during the last few years there are more and more papers dealing with a surprising unexpected high number of patients with shoulder instability following arthroscopic repair. The purpose of this study is to review the long term results of “open” Neer’s capsular shift procedure

Materials & Methods: This is a presentation of 87 (78M; 9F) consecutive patients, 19 to 47 year old (mean 23 Y) with a length of follow-up of 4Y–15Y (mean 6Y). 45 of them with traumatic recurrent anterior dislocation of the shoulder had a capsular shift procedure according to Rockwood’s modification. In 42 other patients that had a multidirectional instability with proved dislocations of the affected shoulder a Protzman’s modified capsular shift procedure was used.

Results: 82/87 patients had a stable shoulder without recurrent dislocation. 3 patients had an episode of traumatic shoulder dislocation within 2 months following operation. Two other patients of 42 with multidirectional instability had a recurrence of traumatic dislocation. One patient developed partial brachial plexus injury, most probably due to traction of the affected limb following operation. 78/87 had at follow-up normal shoulder function with full ROM, and the remaining 9 patients had only a slight limitation in shoulder abduction and in external rotation.

Conclusions: Based on this study, it is suggested that capsular shift procedure is an excellent method for repair of recurrent anterior shoulder dislocation, preferable to the “older” procedures, and allows restoration of shoulder stability with better functional results. This is suitable mainly for patients with structural hyperlaxity and multidirectional instability, whereas arthroscopic stabilization might be used in patients with true traumatic instability.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 26 - 26
1 Jan 2017
Kuenzler M Ihn H Akeda M McGarry M Zumstein M Lee T
Full Access

Insufficiency of the lateral collateral ligamentous complex causes posterolateral rotatory instability (PLRI). During reconstruction surgery the joint capsule is repaired, but its biomechanical influence on elbow stability has not been described. We hypothesized that capsular repair reduces ROM and varus angle after reconstruction of the lateral collateral complex. Six fresh frozen cadaveric elbow specimens were used. Varus laxity in supination, pronation and neutral forearm rotation with 1 Nm load and forearm rotaitonal range of motion (ROM) with 0.3 Nm torque were measured using a Microscribe 3DLX digitizing system (Revware Inc, Raleigh, NC). Each specimen was tested under four different conditions: Intact, Complete Tear with LUCL, RCL and capsule tear, LUCL/RCL reconstruction + capsule repair and LUCL/RCL reconstruction only. Reconstruction was performed according to the docking technique (Jones, JSES, 2013) and the capsule was repaired with mattress sutures. Each condition was tested in 30°, 60° and 90° elbow flexion. A two-way ANOVA with Tukey's post-hoc test was used to detect statistical differences between the conditions. Total ROM of the forearm significantly increased in all flexion angles from intact to Complete tear (p<0.001). ROM was restored to normal in 30° and 60° elbow flexion in both reconstruction conditions (p>0.05). LUCL/RCL Reconstruction + capsule repair in 90° elbow flexion was associated with a significantly lower ROM compared to intact (p=0.0003) and reconstruction without capsule repair (p=0.015). Varus angle increased significantly from intact to complete tear (p<0.0001) and restored to normal in both reconstruction conditions (p>0.05) in 30° and 60° elbow flexion. In contrast varus angle was significantly lower in 90° elbow flexion in both reconstruction conditions compared to intact (both p<0.0001). Reconstruction of the lateral collateral complex restores elbow stability, ROM and varus laxity independent of capsular repair. Over tightening of the elbow joint occurred in 90° elbow flexion, which was aggravated by capsular repair. Over all capsular repair can be performed without negatively affecting elbow joint mobility


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 25 - 25
7 Nov 2023
du Plessis R Roche S du Plessis J Dey R de Kock W de Wet J
Full Access

The Latarjet procedure is a well described method to stabilize anterior shoulder instability. There are concerns of high complication rates, one of these being a painful shoulder without instability due to screw irritation. The arthroscopic changes in the shoulder at time of screw removal compared to those pre-Latarjet have not been described in the literature. We conducted a retrospective review of arthroscopic videos between 2015 and 2022 of 17 patients at the time of their Latarjet screw removal and where available (n=13) compared them to arthroscopic findings at time of index Latarjet. Instability was an exclusion criterion. X-rays prior to screw removal were assessed independently by two observers blinded to patient details for lysis of the graft. Arthroscopic assessment of the anatomy and pathological changes were made by two shoulder surgeons via mutual consensus. An intraclass correlation coefficient (ICC) was analyzed as a measure for the inter-observer reliability for the radiographs. Our cohort had an average age of 21.5±7.7 years and an average period of 16.2±13.1 months between pre- and post-arthroscopy. At screw removal all patients had an inflamed subscapularis muscle with 88% associated musculotendinous tears and 59% had a pathological posterior labrum. Worsening in the condition of subscapularis muscle (93%), humeral (31%) and glenoid (31%) cartilage was found when compared to pre-Latarjet arthroscopes. Three failures of capsular repair were seen, two of these when only one anchor was used. X-ray review demonstrated 79% of patients had graft lysis. Excellent inter-rater reliability was observed with an ICC value of 0.82. Our results show a high rate of pathological change in the subscapularis muscle, glenoid labrum and articular cartilage in the stable but painful Latarjet. 79% of patients had graft lysis with prominent screws on X-ray


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 531 - 537
1 Apr 2017
Henderson ER Keeney BJ Pala E Funovics PT Eward WC Groundland JS Ehrlichman LK Puchner SSE Brigman BE Ready JE Temple HT Ruggieri P Windhager R Letson GD Hornicek FJ

Aims. Instability of the hip is the most common mode of failure after reconstruction with a proximal femoral arthroplasty (PFA) using an endoprosthesis after excision of a tumour. Small studies report improved stability with capsular repair of the hip and other techniques, but these have not been investigated in a large series of patients. The aim of this study was to evaluate variables associated with the patient and the operation that affect post-operative stability. We hypothesised an association between capsular repair and stability. Patients and Methods. In a retrospective cohort study, we identified 527 adult patients who were treated with a PFA for tumours. Our data included demographics, the pathological diagnosis, the amount of resection of the abductor muscles, the techniques of reconstruction and the characteristics of the implant. We used regression analysis to compare patients with and without post-operative instability. Results. A total of 20 patients out of 527 (4%) had instability which presented at a mean of 35 days (3 to 131) post-operatively. Capsular repair was not associated with a reduced rate of instability. Bivariate analysis showed that a posterolateral surgical approach (odds ratio (OR) 0.11, 95% confidence interval (CI) 0.02 to 0.86) and the type of implant (p = 0.046) had a significant association with reduced instability; age > 60 years predicted instability (OR 3.17, 95% CI 1.00 to 9.98). Multivariate analysis showed age > 60 years (OR 5.09, 95% CI 1.23 to 21.07), female gender (OR 1.73, 95% CI 1.04 to 2.89), a malignant primary bone tumour (OR 2.04, 95% CI 1.06 to 3.95), and benign condition (OR 5.56, 95% CI 1.35 to 22.90), but not metastatic disease or soft-tissue tumours, predicted instability, while a posterolateral approach (OR 0.09, 95% CI 0.01 to 0.53) was protective against instability. No instability occurred when a synthetic graft was used in 70 patients. Conclusion. Stability of the hip after PFA is influenced by variables associated with the patient, the pathology, the surgical technique and the implant. We did not find an association between capsular repair and improved stability. Extension of the tumour often dictates surgical technique; however, our results indicate that PFA using a posterolateral approach with a hemiarthroplasty and synthetic augment for soft-tissue repair confers the lowest risk of instability. Patients who are elderly, female, or with a primary benign or malignant bone tumour should be counselled about an increased risk of instability. Cite this article: Bone Joint J 2017;99-B:531–7


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 426 - 434
1 Apr 2019
Logishetty K van Arkel RJ Ng KCG Muirhead-Allwood SK Cobb JP Jeffers JRT

Aims. The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function. Materials and Methods. Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips). Results. Hip resurfacing provided a near-native ROM with between 5° to 17° increase in IR/ER ROM compared with the native hip for the different positions tested, which was a 9% to 33% increase. DM-THA generated a 9° to 61° (18% to 121%) increase in ROM. Conventional THA generated a 52° to 100° (94% to 199%) increase in ROM. Thus, for conventional THA, the capsule function that exerts a limit on ROM is lost. It is restored to some extent by DM-THA, and almost fully restored by hip resurfacing. In positions of low flexion/extension, the posterior capsulotomy provided more normal function than the anterior, possibly because the capsule was shortened during posterior repair. However, in deep flexion positions, the anterior capsulotomy functioned better. Conclusion. Native head-size and capsular repair preserves capsular function after arthroplasty. The anterior and posterior approach differentially affect postoperative biomechanical function of the capsular ligaments. Cite this article: Bone Joint J 2019;101-B:426–434


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 48 - 48
1 Jul 2020
Ng G Daou HE Bankes M y Baena FR Jeffers J
Full Access

Surgical management of cam-type femoroacetabular impingement (FAI) aims to preserve the native hip, restore joint function, and delay the onset of osteoarthritis. However, it is unclear how surgery affects joint mechanics and hip joint stability. The aim was to examine the contributions of each surgical stage (i.e., intact cam hip, capsulotomy, cam resection, capsular repair) towards hip joint centre of rotation and microinstability. Twelve fresh, frozen cadaveric hips (n = 12 males, age = 44 ± 9 years, BMI = 23 ± 3 kg/m2) were skeletonized to the capsule and included in this study. All hips indicated cam morphology on CT data (axial α = 63 ± 6°, radial α = 74 ± 4°) and were mounted onto a six-DOF industrial robot (TX90, Stäubli). The robot positioned each hip in four sagittal angles: 1) Extension, 2) Neutral 0°, 3) Flexion 30°, and 4) Flexion 90°, and performed internal and external hip rotations until a 5-Nm torque was reached in each direction, while recording the hip joint centre's neutral path of translation. After the (i) intact hip was tested, each hip underwent a series of surgical stages and was retested after each stage: (ii) T-capsulotomy (incised lateral iliofemoral capsular ligament), (iii) cam resection (removed morphology), and (iv) capsular repair (sutured portal incisions). Eccentricity of the hip joint centre was quantified by the microinstability index (MI = difference in rotational foci / femoral head radius). Repeated measures ANOVA and post-hoc paired t-tests compared the within-subject differences in hip joint centre and microinstability index, between the testing stages (CI = 95%, SPSS v.24, IBM). At the Extension and Neutral positions, the hip joint centre rotated concentrically after each surgical stage. At Flexion 30°, the hip joint centre shifted inferolaterally during external rotation after capsulotomy (p = 0.009), while at Flexion 90°, the hip joint centre further shifted inferolaterally during external rotation (p = 0.005) and slightly medially during internal rotation after cam resection, compared to the intact stages. Consequently, microinstability increased after the capsulotomy at Flexion 30° (MI = +0.05, p = 0.003) and substantially after cam resection at Flexion 90° (MI = +0.07, p = 0.007). Capsular repair was able to slightly restrain the rotational centre and decrease microinstability at the Flexion 30° and 90° positions (MI = −0.03 and −0.04, respectively). Hip microinstability occurred at higher amplitudes of flexion, with the cam resection providing more intracapsular volume and further lateralizing the hip joint during external rotation. Removing the cam deformity and impingement with the chondrolabral junction also medialized the hip during internal rotation, which can restore more favourable joint loading mechanics and stability. These findings support the pathomechanics of cam FAI and suggest that iatrogenic microinstability may be due to excessive motions, prior to post-operative restoration of static (capsular) and dynamic (muscle) stability. In efforts to limit microinstability, proper nonsurgical management and rehabilitation are essential, while activities that involve larger amplitudes of hip flexion and external rotation should be avoided immediately after surgery


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 365 - 366
1 Sep 2005
Khan R Fick D Nivbrant B Khoo P Wood D
Full Access

Introduction and Aims: A number of ‘minimally invasive’ approaches have been described which are essentially a standard approach through a smaller incision: the term ‘mini-incision’ is more appropriate. We describe a new technique that is truly soft-tissue sparing and report our early results. Method: Following Malchau’s principles we performed cadaver studies to familiarise ourselves with the approach before conducting a pilot study. The approach involves a 6–8cm oblique incision over the posterior aspect of the greater trochanter. Care is taken to preserve piriformis and gluteus maximus. Meticulous capsular repair is performed through drill holes into bone at the end of the procedure to reconstruct the posterior envelope. There are no restrictions to mobility post-op. Patients were scored pre-operatively and followed up prospectively. The only special instruments required are two large curved Hohmann retractors and an angled cup introducer. Results: One hundred and one consecutive routine primary total hip replacements were performed via the ‘piriformis-sparing minimally invasive approach’ by a single surgeon. Marked on-table stability was noted in all hips prior to capsular repair. Forty-two percent of patients were male. Mean age was 68.9 years (42–90) and BMI 26 (14–39). Average operation time was 64.1 minutes and anaesthetic time 92.5 minutes. Mean fall in haemoglobin in the first 24 hours was 2.3g/dl. Mean incision length was 7.4cm. Follow-up was a minimum of one year (range 12–29 months). There was a highly statistically significant improvement in WOMAC and SF-36 scores at three and 12 months post-operatively (p< 0.0001). Early medical complications occurred in 12 patients, including two superficial infections, all of which resolved. There were no peri-prosthetic fractures and importantly, no dislocations. There were two re-operations: one revision for cup displacement and one washout for deep infection. Conclusion: We believe that the marked stability that we achieve on-table is only possible by sparing piriformis and careful capsular repair. As with all new procedures however, there is a learning curve for both surgeon and assistant. Preliminary results from our pilot study may be interpreted with guarded optimism


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 141 - 144
1 Jan 2015
Hughes AW Clark D Carlino W Gosling O Spencer RF

Reported rates of dislocation in hip hemiarthroplasty (HA) for the treatment of intra-capsular fractures of the hip, range between 1% and 10%. HA is frequently performed through a direct lateral surgical approach. The aim of this study is to determine the contribution of the anterior capsule to the stability of a cemented HA through a direct lateral approach. . A total of five whole-body cadavers were thawed at room temperature, providing ten hip joints for investigation. A Thompson HA was cemented in place via a direct lateral approach. The cadavers were then positioned supine, both knee joints were disarticulated and a digital torque wrench was attached to the femur using a circular frame with three half pins. The wrench applied an external rotation force with the hip in extension to allow the hip to dislocate anteriorly. Each hip was dislocated twice; once with a capsular repair and once without repairing the capsule. Stratified sampling ensured the order in which this was performed was alternated for the paired hips on each cadaver. . Comparing peak torque force in hips with the capsule repaired and peak torque force in hips without repair of the capsule, revealed a significant difference between the ‘capsule repaired’ (mean 22.96 Nm, standard deviation (. sd. ) 4.61) and the ‘capsule not repaired’ group (mean 5.6 Nm, . sd. 2.81) (p < 0.001). Capsular repair may help reduce the risk of hip dislocation following HA. Cite this article: Bone Joint J 2015;97-B:141–4


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1202 - 1206
1 Sep 2014
Kumar V Sharma S James J Hodgkinson JP Hemmady MV

Despite a lack of long-term follow-up, there is an increasing trend towards using femoral heads of large diameter in total hip replacement (THR), partly because of the perceived advantage of lower rates of dislocation. However, increasing the size of the femoral head is not the only way to reduce the rate of dislocation; optimal alignment of the components and repair of the posterior capsule could achieve a similar effect. . In this prospective study of 512 cemented unilateral THRs (Male:Female 230:282) performed between 2004 and 2011, we aimed to determine the rate of dislocation in patients who received a 22 mm head on a 9/10 Morse taper through a posterior approach with capsular repair and using the transverse acetabular ligament (TAL) as a guide for the alignment of the acetabular component. The mean age of the patients at operation was 67 years (35 to 89). The mean follow-up was 2.8 years (0.5 to 6.6). Pre- and post-operative assessment included Oxford hip, Short Form-12 and modified University of California Los Angeles and Merle D’Aubigne scores. The angles of inclination and anteversion of the acetabular components were measured using radiological software. There were four dislocations (0.78%), all of which were anterior. In conclusion, THR with a 22 mm diameter head performed through a posterior approach with capsular repair and using the TAL as a guide for the alignment of the acetabular component was associated with a low rate of dislocation. Cite this article: Bone Joint J 2014;96-B:1202–6


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 387 - 387
1 Jul 2008
Trehan R Kumar G Shetty A Naidu V
Full Access

The authors report the use of a modified ‘Y-V’ medial capsular repair in association with Scarf osteotomy for Hallux valgus in 55 patients (62 feet) aged 18 to 61 years (mean 43 years) between July 2004 and July 2005. All patients were followed up for minimum 6 months by questionnaire, physical examination (American Orthopaedic Foot and Ankle Society score) and comparison of preoperative and post operative x rays. Using this technique none of the patients required an additional proximal phalangeal osteotomy (Akin Oste-otomy). At six months follow up American Orthopaedic Foot and Ankle Society score improved from 46 to 87. Intermetatarsal (IM) angle and the hallux valgus (HV) angle improved from 16 degree to 9 degree and from 31 degree to 16 degrees respectively (p less than 0.05). Of the sixty two procedures 59 did not develop any complications. Two had superficial infections which required oral antibiotics only. One partial loss of correction of hallux valgus occurred for which the patient refused a second operation. Seven cases had some residual pronation deformity of the big toe identified by the patients who felt the deformity was ‘about 50%’ compared to before the operation. Akins osteotomy achieves an apparent correction of hallux valgus without addressing subluxation of meta-tarso-phalangeal joint. Our technique reduces the meta-tarso-phalangeal joint and corrects the hallux valgus angle anatomically. We recommend the use of this modified ‘Y-V’ medial capsular repair to correct the hallux valgus angle and reduce the need for an additional procedure to augment the correction achieved during Scarf osteotomy for hallux valgus


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1208 - 1214
1 Sep 2016
Cowling PD Akhtar MA Liow RYL

Objectives. A variety of operative techniques have been described as under the term ‘Bristow-Latarjet’ procedure. This review aims to define the original procedure, and compare the variation in techniques described in the literature, assessing any effect on clinical outcomes. Materials and Methods. A systematic review of 24 studies was performed to compare specific steps of the technique (coracoid osteotomy site, subscapularis approach, orientation and position of coracoid graft fixation and fixation method, additional labral and capsular repair) and detect any effect this variability had on outcomes. Results. Overall recurrence rate was 5.36% (2.94% to 43%). Half of the studies performed the procedure for recurrent shoulder instability, with only five studies documenting glenoid bone loss as an indication: 12 studies used the procedure as the primary surgical intervention for recurrent instability. No change in outcome was noted when examining variation in the coracoid osteotomy site, the fixation site on the scapular neck, the fixation method or whether a capsular repair was also performed. Performing a horizontal split in subscapularis may preserve external rotation compared with performing a tenotomy. Conclusions. This is the first review to examine various operative techniques of the Bristow-Latarjet procedure, and their effect on outcome. We found that other than the approach through subscapularis, outcome was independent of the surgical technique, and depended more on patient selection. We would commend future publications on this procedure to provide a detailed description of the surgical technique, and as a minimum present rates of recurrence as an outcome measure. Cite this article: Bone Joint J 2016;98-B:1208–14