The aim of this study was to quantify the stability
of fracture-implant complex in fractures after fixation. A total
of 15 patients with an undisplaced fracture of the femoral neck,
treated with either a dynamic hip screw or three cannulated hip
screws, and 16 patients with an AO31-A2 trochanteric fracture treated
with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric
analysis was used at six weeks, four months and 12 months post-operatively
to evaluate shortening and rotation. Migration could be assessed in ten patients with a fracture of
the femoral neck and seven with a trochanteric fracture. By four
months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1)
had occurred in the fracture of the femoral neck group and 5.0 mm
(-0.13 to 12.9) in the trochanteric fracture group. A wide range
of rotation occurred in both types of fracture. Right-sided trochanteric
fractures seem more rotationally stable than left-sided fractures. This prospective study shows that migration at the fracture site
occurs continuously during the first four post-operative months,
after which stabilisation occurs. This information may allow the
early recognition of patients at risk of failure of fixation. Cite this article:
Aims. In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures. Methods. This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had
Purpose of Study. Bicondylar tibial plateau fractures are serious injuries to a major weight bearing joint. These injuries are often associated with severe soft tissue injuries that complicate the surgical management. This retrospective study evaluates the management of these high-energy injuries with the use of limited open reduction and fine wire circular external fixation. Methods. Between July 2008 and June 2012, 54 consecutive patients (19 females and 35 males) with high-energy tibial plateau fractures were treated at our tertiary level government hospital. All patients were treated with limited open reduction, and
Objective: To evaluate the results of
The majority of pediatric proximal humerus fractures are successfully treated non-operatively. Significantly displaced fractures have traditionally been treated surgically with percutaneous pinning. This review of twenty-three surgically treated patients demonstrates a high rate of infection associated with percutaneous pinning. The technique of
Intracapsular neck of femur fractures may be treated with fixation or arthroplasty, depending on fracture characteristics and patient factors. Two common methods of fixation are the sliding hip screw, with or without a de-rotation screw, and cannulated screws. Each has its merits, and to date there is controversy around which method is superior, with either method thought to risk avascular necrosis of the femoral head (AVN) rates in the region of 10–20%.
Introduction. Management of the sequelae of arthritis of the hip joint has changed over time. Total joint replacement has gained popularity due to retained mobility and stability. In the high demand paediatric and adolescent population problems are encountered with longevity of the procedure. Hip arthrodesis is a useful alternative procedure that sacrifices mobility of the joint to achieve pain relief and restores function. Several surgical techniques have been described to achieve hip fusion. We describe a technique that achieves concentric bone surfaces with hip resurfacing reamers. Maximum bone is preserved to maintain leg length. Trans-articular compression is achieved with
Stickler’s syndrome, also called Hereditary Progressive Arthro-Ophthalmopathy, is an autosomal dominant connective tissue disorder with strong expressivity, characterised by ocular, orofacial, skeletal, cardiac, and auditory features. We describe a case of valgus slipped capital femoral epiphysis in a 13 year-old boy with Stickler’s syndrome. He presented at routine rheumatology clinic follow-up with a 1-month history of progressively worsening right hip pain, which radiated to the knee. He underwent insitu
Our objective is to show the results of the unstable slipped capital femoral epiphysis treatment with reduction and threaded screw fixation. A retrospective analysis of 21 patients (13 boys and 8 girls) with unstable slipped capital femoral epiphysis was performed between 1993 and 1998. The right hip was involved in 13 patients and the left hip in 8. The patients presented acute pain and functional difficulties. The diagnoses were based on the clinical presentation, neutral and Lowestein hip x-rays. The treatment consisted on gentle manipulative reduction of the unstable slip (flexion and internal rotation), threaded
Background. Despite studies into patient consent and their understanding of the potential risks of trauma surgery, no study has looked at the patient's understanding of the procedure involved with neck of femur fracture surgery. Method. Prospective analysis of 150 patients who had operative fixation of neck of femur fractures in a district general hospital. Patients were asked on the third post-operative day to select which procedure they had undergone from a diagram of four different neck of femur surgeries (cannulated screws, cephalomedullary nail, dynamic hip screw and hemiarthroplasty). Exclusion criteria for patient selection - mini mental score of < 20 and confusion secondary to delirium. Results. All patients had signed consent form 1 which was matched to the procedure. All patients were consented by an FP2, CT1 or other SHO. The mean age of patients was 83years. 5% had
This purpose of this study was to investigate whether prophylactic pinning of the contralateral hip in unilateral slipped upper femoral epiphysis affects subsequent femoral morphology. To determine the effect of prophylactic pinning on growth we compared contralateral hip radiographs of 24 proximal femora prophylactically pinned with 26 cases observed, in a cohort of patients with unilateral SUFE. Validated measurements were used to determine hip morphology; the articulo-trochanteric distance (ATD) and the ratio of the trochanteric-trochanteric distance (TTD) to articulo-trochanteric distance (TTD:ATD) in addition to direct measurement of the femoral neck length. Post-operative radiographs were compared to radiographs taken at a 12–84 months follow-up. Comparing pinned and unpinned hips the neck length was shorter (mean 5.1 mm vs 11.1 mm) and the ATD was lower (p=0.048). The difference between initial and final radiograph TTD:ATD ratio for each case was calculated. The average was 0.63 in the prophylactically pinned group and 0.25 in the unpinned group (p=0.07). When hips of the same patient were compared on final radiographs, there was a smaller difference in TTD:ATD between the two sides when the patient had been prophylactically pinned (0.7) as opposed to observed (1.47). This was not statistically significant (p=0.14). Universal prophylactic pinning of the contralateral hip in slipped upper femoral epiphysis is controversial and alteration of the proximal femoral morphology is one reason for this. Our results show that prophylactic pinning does not stop growth but does alter subsequent proximal femoral morphology by causing a degree of coxa vara and breva. Some loss of growth in the prophylactically pinned hip contributes to reduction in leg length inequality at skeletal maturity which is advantageous. No iatrogenic complications were observed with single
Proximal femoral fractures remain the most common reason for admission to hospital following orthopaedic injury, with an annual cost of £1.7 billion to the National Health Service and social care services. Fragility fractures of the hip in the elderly are a substantial cause of mortality and morbidity. Revision surgery for any cause carries a higher morbidity, mortality, healthcare- and social economic burden. Which patients suffer failed surgery and the reasons for failure have not been established. The aim of this study was to determine which patients are at risk of failed proximal femoral fracture surgery, the mechanism and cause fo failed surgery and modifiable patient factors associated with failure of hip fracture surgery. From prospectively collected data of 795 consecutive proximal femoral fractures admitted between July 2007 and July 2008, all peri-operative and post-operative complications were identified. 55 (6.9%) patients were found to have developed a surgical complication requiring further intervention. Risk factors included younger age (p=0.01), smoking (p=0.01) and
Purpose: To determine if femoral neck shortening after
INTRODUCTION – Tuberosity fractures of the calcaneum are rare injuries. The traditional operative treatment involves open reduction and internal fixation with a tension band wire construct. We have developed a new technique of fixing these fractures with internal
The consequences of the complications associated with the management of slipped upper femoral epiphysis are a major source of disability in young adults. Whilst the management of chondrolysis, avascular necrosis or malunion of the femoral neck is usually undertaken by paediatric orthopaedic surgeons the initial management of SUFE in many regions is as part of an adult trauma service. This retrospective audit assessed the outcome of the management of SUFE in one such health region in which treatment occurred at three sites by a number of surgeons of varying experience, during the period July 1994 to June 2004. The aim was to compare our outcomes with those published and to identify whether our service should be altered as a consequence. The case notes and x-rays as recorded in theatre records were retrieved. Of the 64 cases that were treated during this period adequate records for 60 patients were available. Of these 60 patients there were 7 bilateral cases. Fixation in all 67 cases was by a single cannulated screw. In the 53 unilateral cases 17 underwent prophylactic pinning, the remaining 36 remained under observation. Of these nine patients presented with subsequent slips, eight of which were unstable and two had slip angles greater than 60° in which one developed avascular necrosis. Four other cases of avascular necrosis were observed (incidence 6%). Chondrolysis occurred in one patient with persistent pin penetration. In the remaining 73 cannulated screws used for stabilisation and 17 for prophylactic fixation no complications were observed. The complication rates observed in this series are within those accepted in the literature. The high incidence of subsequent slips and the attendant severity of these when compared with the relative safety of contemporary
Background: Fracture of the scaphoid bone is the most common fracture of the carpus and frequently diagnosis is delayed. The unique anatomy &
blood supply of the scaphoid itself predisposes to delayed union or non-union. The Synthes scaphoid screw is a cannulated headed screw, which provides superior compression compared with some other devices used to internally fix scaphoid non-unions. Aim: To conduct a retrospective study looking at union rate, time to union and complications and correlating the outcome of treatment against the delay between injury and surgery and location of the fracture within the bone. Methods: 36 patients with scaphoid non-union (30 waist &
6 proximal pole) treated by a single surgeon with the cannulated Synthes screw &
corticocancellous bone graft were reviewed retrospectively. Results: We achieved 78% overall union rate. Those patients operated within 6 months of injury achieved 100% union rate. Of the patients with persistent non-union after surgery, half reported no pain and increased movement in the wrist. The failure rate was high in patients whose injury was more than 5 years old, and in proximal pole non-unions. Conclusion: Our study demonstrates that
Background: To highlight the higher incidence of sub-trochanteric fracture following
Purpose: Open reduction and internal fixation (ORIF) is considered the treatment of choice in dislocated acetabular fractures. However ORIF has several drawbacks, such as intra operative blood loss, operative trauma and septic complications. To overcome these problems we applied percutaneous
Aims and Methods: Hungary, 60% (3500 cases annually) of all fresh intracapsular femoral neck fractures are traditionally treated by osteosynthesis. Since 1990 nailing has been replaced: from 01.11.1990 to 31.08.2002 the authors performed 3092 procedures using percutaneous double
Introduction: The consequences of the complications associated with the management of slipped upper femoral epiphysis are a major source of disability in young adults. Whilst the management of chondrolysis, avascular necrosis or malunion of the femoral neck is usually undertaken by paediatric orthopaedic surgeons the initial management of SUFE in many regions is as part of an adult trauma service. This retrospective audit assessed the outcome of the management of SUFE in one such health region in which treatment occurred at three sites by a number of surgeons of varying experience. The aim was to compare our outcomes with those published and to identify any local issues. Method: Review of case notes and xrays of all patients treated over a ten year period as recorded in theatre records. Fixation in all cases was by a single cannulated screw. Results: Of the 64 cases that presented during this period adequate records for 60 patients were retrieved. 75 slips were recorded, 15 of which were bilateral. In 17 patients prophylactic pinning was performed in the remaining 43 patients nine presented with subsequent slips. Of these, eight were unstable of which two had slip angles greater than 60°, in one of these avascular necrosis developed. Three other cases of avascular necrosis occurred (incidence 5%) all in unstable slips. Chondrolysis occurred in one patient with persistent pin penetration. In the remaining 91 cannulated screws that were inserted no complications were observed. Discussion: The complication rates observed in this series are within those accepted in the literature. The high incidence of subsequent slips and the attendant severity of these when compared with the relative safety of contemporary